NORD-LOCK WASHERS The original wedge-locking solution ENGLISH
- METRIC
2 Nord-Lock washers secure bolted joints with tension instead of friction. The system is comprised of a pair of washers with cams on one side and radial teeth on the opposite side.
Since the cam angle is greater than the thread pitch a wedge effect is created by the cams, preventing the bolt from rotating loose.
The proven original Nord-Lock wedge-locking products are the ideal choice for critical bolted joints.
Nord-Lock wedge-locking technology Since the Nord-Lock Group began operations in 1982 we have focused on providing the worlds most effective bolt securing system. Our products are based on leading wedge-locking technology and are recognized for their ability to safely secure bolted joints exposed to severe vibration and dynamic loads.
When you choose Nord-Lock you do not only choose a supplier or a manufacturer, you also benefit from a partnership with an expert in bolted joint technology. Our global team of sales engineers work with our clients to solve bolt securing problems in the most demanding applications.
3 Nord-Lock washers are proven as a safe bolt securing system according to DIN 65151 tests performed by the independent research organizations IMA and CETIM. In addition, Nord-Lock personnel performs over 10,000 live Junker vibration tests around the globe every year. Would you like to see a live demonstration? Find your nearest representative through www.nord-lock.com/contact Fig 2: Drawing of the test rig. The assembled parts are vibrated vertically and the joints are subjected to two impacts per cycle.
The impacts are parallel to the bolt. The arrow displays the direction of vibration during the test. After testing, the fasteners are inspected for rotation.
Load cycles Untightening Clamp load [kN]
Regular nut M8 on bolt with Nord-Lock at 70% of yield point Regular nut M8 on bolt with extension socket, clamp length 50 mm Nylon-inserted nut Split ring Regular nut M8 on bolt Proven in Junker vibration test The Junker test, according to DIN 65151, is considered the most severe vibration test for bolted connections. During the test, the joint is exposed to transverse movements underneath the bolt head / nut, while the clamping force is continuously measured.
Proven according to NASM impact & vibration test The National Aerospace test, according to NASM 1312-7, is a test method originally developed by the U.S. military to test bolted connections resilience against impact and vibration.
Fig 1: The Junker test shows that Nord-Lock washers safely secured the bolted connection; only a limited amount of tension is initially lost due to normal settlements. The wedge-locking function is verified through the clear increase in tension during untightening. All other bolt locking methods in the test failed to prevent loosening of the joint.
Nord-Lock washers are proven as a safe bolt securing system according to NASM 1312-7 tests performed by the independent organization Det Norske Veritas (DNV). If you wish to perform your own real-life testing and evaluation of Nord-Lock washers for your application, you can order samples through www.nord-lock.com/contact Vibration test Bolt M8 (8.8) with clamp length 25 mm Over the years, Nord-Lock washers have been rigorously tested and approved by independent institutes as well as certification authorities.
Proven and certified by TÜV Nord-Lock washers have been certified for safety and quality by TÜV, a leading international institute in quality and safety certification. In a two-step process, TÜV monitored and successfully approved both Nord-Lock washers and Nord-Locks production facilities.
4 Nord-Lock washers are high end products with documented success in many industries. Our washers are approved by several industry standards and specified by numerous international companies.
Industries where Nord-Lock washers are used Nord-Lock washers are used in industries such as: energy, transportation, offshore, mining and quarrying, construction and bridge building, manufacturing and processing, ship building, forestry and agriculture, heavy vehicles, and military. The number of industries that use Nord-Lock washers is continuously growing. Often joints do not start to loosen until an application is in regular use, therefore Nord-Lock washers are commonly retrofitted during maintenance, repair and overhaul procedures.
Certificates & approvals The most prominent certificates are from:
- DIBt (Deutsches Institut für Bautechnik)
- DNV (Det Norske Veritas)
- EBA (Eisenbahn-Bundesamt)
- TÜV (Technischer Überwachungs-Verein)
Quality & environmental assurance
- ISO 9001
- ISO 14001
- Licensed by Drken to perform Delta Protekt surface coating in-house
- RoHs, ELV and Reach compliant
- Full traceability For more information or a complete list of certificates and approvals, please visit our website or contact your nearest Nord-Lock representative.
Widely used &
globally approved Washer type Code Steel, Delta Protekt coating flZn Stainless steel SS 254 SMO 254 INCONEL / HASTELLOY C-276 276 INCONEL 718 718 Nord-Lock laser marks various sizes of our products with the Nord-Lock brand name, control number and a type code. This is to ensure that all of our customers receive genuine Nord-Lock washers and enables full traceability down to the first assembly.
Traceability Nord-Lock washers are rigorously tested in all steps of production to verify that the quality requirements are met.
Each batch is assigned a control number which ensures full traceability and confirms that the washer is a genuine Nord-Lock article. The control number is printed on the package and products are laser marked, enabling full traceability down to first assembly - even when using bin systems for fastener supply.
Laser marking, type code table
5 Nord-Lock washers provide more than just a safe locking function, using our washers also improves the general performance of a bolted joint.
Product benefits
- Maintains high clamp load and thereby ensures the function of the joint
- Quick and easy to install and remove with standard tools
- Locking function not affected by lubrication
- Defined and uniform friction conditions which result in a more accurate preload
- Same temperature characteristics as standard bolt / nut
- Reusable - in addition, Nord-Lock washers do not affect the reusability of fasteners
- The washers are hardened and can support and distribute great loads
- Washers with enlarged outer diameter available for flanged bolts / nuts
- High corrosion resistance
- Can be used with fasteners up to grade 12.9 (ASTM A574)
- Reliable locking, even for joints with short clamp length
- Secures fasteners at both high and low preloads
- No retightening needed
- Verifiable locking function
- Elegant solution and problem solving - modern engineering More than a physical product Nord-Lock offers more than just secure bolted joints. When designing an application, it is important to consider the result it will generate throughout the entire lifespan. When using Nord-Lock products you also benefit from our experience and knowledge. We guide you towards the most beneficial and effective bolt design.
The key to efficient
& secure operations Technical Center Our skilled and innovative staff is available to help, review and discuss your applications in order to optimize the design of your bolted connections. Many companies take advantage of the extended services we offer in our in-house laboratories located in Europe, North America and Asia. These services comprise customized tests, failure analysis and joint calculations. In addition, we offer on-site and remote product training and installation services.
Nord-Lock products can help you increase your profitability by considering the complete life cycle cost for bolt securing.
Life Cycle Profitability Over the operational life cycle, Nord-Lock products give increased operational reliability and lower maintenance costs while significantly reducing the risks of production stops, accidents and warranty claims. We help you examine all cost factors related to bolted joints.
Failure costs Maintenance and re-tightening costs First installation Product costs Design costs
6 Nord-Lock washers are easy and effective to use while ensuring structural security for applications exposed to vibration and dynamic loads.
Installing the washers The pre-assembled washers are installed in pairs, cam face to cam face. Nord-Lock recommends lubrication when possible.
Tightening Tighten Nord-Lock washers with standard tools according to the guidelines (on page 9-11). Tightening guidelines for other bolt grades are available through your Nord-Lock representative.
Untightening Untightening Nord-Lock washers is as simple as tightening.
Note that since the locking function is not based on increased friction, the untightening torque is generally lower than the tightening torque. Therefore it is not possible to measure off-torque as verification of locking function.
Reusing Nord-Lock Nord-Lock washers can normally be reused. As with all fasteners, they should be inspected for wear before reassembly. Make sure that the washers are reinstalled correctly cam face to cam face. Nord-Lock recommends lubrication of fasteners before reuse in order to minimize changes in friction conditions.
Using Nord-Lock washers When the two criteria above are met, you have verified the locking function of the Nord-Lock washers.
Utilize the advantages of lubrication Nord-Lock recommends the use of a high quality, anti-seize lubricant as it improves the tightening results. It is especially beneficial for large sized bolts and stainless steel applications.
The Nord-Lock wedge-locking function provides safe locking in both dry and lubricated conditions. Benefits of lubricated fasteners include:
- Improved reusability
- Reduced friction and deviation
- Facilitated assembly and disassembly
- Reduced torsion stress due to minimized thread friction
- Avoided galling and thread seizure
- Additional protection against corrosion When untightening a bolt secured by Nord-Lock washers, check that sliding occurs between the cam faces.
After disassembly, impression marks must be visible on both the fastener and the contact surface.
Possible to verify the locking function
7 Nord-Lock washer material / type guide Steel type (EN) 1.7182 or equivalent 1.4404 or equivalent 1.4547 or equivalent 2.4819 or equivalent 2.4667 or equivalent Examples of applications General steel applications General stainless steel applications.
Non chlorine / acid environments General salt water applications, pumps, chloride applications, heat exchangers, nuclear, desalination, food processing & medical equipment General acidic environments, process and chemical industry, evaporators, offshore downhole tooling Applications with high temperatures, gas turbines, turbo charges, incinerators Available for bolt sizes M3-M130 (see page 8 for dimensions)
M3-M80 (see page 10 for dimensions)
M3-M39 (see page 11 for dimensions)
M3-M39 available upon request M3-M39 available upon request Washer types Regular outer diameter (NL3-NL130)
Enlarged outer diameter (NL3,5sp-NL36sp)
Regular outer diameter (NL3ss-NL80ss)
Enlarged outer diameter (NL3,5spss-NL30spss)
Regular outer diameter (NL3ss-254-NL39ss-254)
Enlarged outer diameter (NL3,5spss-254-NL27spss-254)
Regular outer diameter (NL3ss-276-NL39ss-276)
Enlarged outer diameter (NL3,5spss-276-NL27spss-276)
Regular outer diameter (NL3ss-718-NL39ss-718)
Enlarged outer diameter (NL3,5spss-718-NL27spss-718)
Treatment Surface coating Through hardened Delta Protekt base coat (KL100) and top coat (VH302GZ)
Surface hardened Surface hardened Surface hardened Surface hardened Washer hardness*
465 HV1 520HV0,05 600HV0,05 520HV0,05 620HV0,05 Corrosion resistance Minimum 600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> in salt spray test (according to IS09227)
PREN 27**
PREN 45**
PREN 68**
PREN 29**
Bolt grades Up to 12.9 Up to A4-80 Up to A4-80 Up to A4-80 Up to A4-80 Temperature range***
-50°C to 200°C
-160°C to 500°C
-160°C to 500°C
-160°C to 500°C
-160°C to 700°C Application parameter Steel washers Stainless steel (ss) washers 254 SMO washers INCONEL/
HASTELLOY C-276 washers INCONEL 718 washers In order to assure the unique mechanical locking function of the Nord-Lock washers, the hardness of the mating surfaces must be lower than the hardness of the Nord-Lock washers (see table above).
- PREN (Pitting Resistance Equivalent Number) = %Cr + 3,3x%Mo + 16x%N. Figures in table valid for base material. A higher PRE number
indicates better corrosion resistance.
- Temperature recommendations based on information from the raw material supplier and from tests. Locking function not affected within the specification.
8
Øo
Øi T
Nord-Lock steel washers EN 1.7182 or equivalent, zinc flake coating (Delta Protekt), through hardened Washer size Bolt size
øi
[mm]
øo
[mm]
Thickness T
[mm]
Min. package
[pairs]
Approx. weight kg / 100 pairs Metric UNC
- Please consult our website for current dimensions and 2D / 3D CAD models:
www.nord-lock.com/cad Nord-Lock steel washers of sizes 3-42 and with zinc flake coating are standard stock items, yet subject to prior sale.
Note that washers with thickness 6,6 mm have a thickness tolerance +0,0 / -0,5 mm Dimension chart NL3 M3
- 5 3,4 7,0 1,8 200 0,03 NL3,5 M3,5
- 6 3,9 7,6 1,8 200 0,04 NL3,5sp M3,5
- 6 3,9 9,0 1,8 200 0,06 NL4 M4
- 8 4,4 7,6 1,8 200 0,04 NL4sp M4
- 8 4,4 9,0 1,8 200 0,06 NL5 M5
- 10 5,4 9,0 1,8 200 0,05 NL5sp M5
- 10 5,4 10,8 1,8 200 0,11 NL6 M6 6,5 10,8 1,8 200 0,07 NL6sp M6 6,5 13,5 2,5 200 0,20 NL1/4 1/4 7,2 11,5 2,5 200 0,08 NL1/4sp 1/4 7,2 13,5 2,5 200 0,18 NL8 M8 5/16 8,7 13,5 2,5 200 0,15 NL8sp M8 5/16 8,7 16,6 2,5 200 0,28 NL3/8 3/8 10,3 16,6 2,5 200 0,23 NL3/8sp 3/8 10,3 21,0 2,5 200 0,48 NL10 M10 10,7 16,6 2,5 200 0,22 NL10sp M10 10,7 21,0 2,5 200 0,47 NL11 M11 7/16 11,4 18,5 2,5 200 0,29 NL12 M12 13,0 19,5 2,5 200 0,29 NL12sp M12 13,0 25,4 3,4 100 0,93 NL1/2 1/2 13,5 19,5 2,5 200 0,27 NL1/2sp 1/2 13,5 25,4 3,4 100 0,90 NL14 M14 9/16 15,2 23,0 3,4 100 0,56 NL14sp M14 9/16 15,2 30,7 3,4 100 1,41 NL16 M16 5/8 17,0 25,4 3,4 100 0,67 NL16sp M16 5/8 17,0 30,7 3,4 100 1,28 NL18 M18 19,5 29,0 3,4 100 0,89 NL18sp M18 19,5 34,5 3,4 100 1,58 NL3/4 3/4 20,0 30,7 3,4 100 1,05 NL3/4sp 3/4 20,0 39,0 3,4 100 2,21 NL20 M20 21,4 30,7 3,4 100 0,93 NL20sp M20 21,4 39,0 3,4 100 2,09 NL22 M22 7/8 23,4 34,5 3,4 100 1,25 NL22sp M22 7/8 23,4 42,0 4,6 50 3,19 NL24 M24 25,3 39,0 3,4 100 1,74 NL24sp M24 25,3 48,5 4,6 50 4,51 NL1 1
27,9 39,0 3,4 100 1,53 NL1sp 1
27,9 48,5 4,6 50 4,20 NL27 M27 28,4 42,0 5,8 50 3,14 NL27sp M27 28,4 48,5 5,8 25 5,27 NL30 M30 1 1/8 31,4 47,0 5,8 50 4,10 NL30sp M30 1 1/8 31,4 58,5 6,6 25 8,58 NL33 M33 1 1/4 34,4 48,5 5,8 25 3,89 NL33sp M33 1 1/4 34,4 58,5 6,6 25 8,00 NL36 M36 1 3/8 37,4 55,0 5,8 25 5,49 NL36sp M36 1 3/8 37,4 63,0 6,6 25 9,15 NL39 M39 1 1/2 40,4 58,5 5,8 25 5,89 NL42 M42 43,2 63,0 5,8 25 7,97 NL45 M45 1 3/4 46,2 70,0 7,0 25 10,20 NL48 M48 49,6 75,0 7,0 25 12,00 NL52 M52 2
53,6 80,0 7,0 25 13,00 NL56 M56 2 1/4 59,1 85,0 7,0 10 13,50 NL60 M60 63,1 90,0 7,0 10 15,20 NL64 M64 2 1/2 67,1 95,0 7,0 10 16,70 NL68 M68 71,1 100,0 9,5 1
28,20 NL72 M72 75,1 105,0 9,5 1
30,70 NL76 M76 3
79,1 110,0 9,5 1
33,30 NL80 M80 3 1/8 83,1 115,0 9,5 1
36,00 NL85 M85 88,1 120,0 9,5 1
37,80 NL90 M90 92,4 130,0 9,5 1
47,70 NL95 M95 97,4 135,0 9,5 1
49,80 NL100 M100 4
103,4 145,0 9,5 1
58,90 NL105 M105 108,4 150,0 9,5 1
61,30 NL110 M110 113,4 155,0 9,5 1
63,50 NL115 M115 118,4 165,0 9,5 1
75,30 NL120 M120 123,4 170,0 9,5 1
77,90 NL125 M125 128,4 173,0 9,5 1
76,60 NL130 M130 5
133,4 178,0 9,5 1
79,20 NL3-NL8
Øi+/-0,1 mm NL10-NL42
Øi+/-0,2 mm NL45-NL130
Øi+0,5 / -0,0 mm NL3-NL24
Øo+/-0,2 mm NL27-NL42
Øo+/-0,3 mm NL45-NL130
Øo+0,0 / -2,0 mm NL3-NL42 T+/-0,25 mm NL45-NL130 T+/-0,75 mm
9 Torque guidelines Nord-Lock steel washers with zinc flake coating (Delta Protekt)
Nord-Lock steel washers with electro zinc plated bolt grade 8.8 Cu/C paste = copper/graphite paste (Molykote 1000)
Oil = WD40 has been used.
GF = Ratio of yield point. When tightening according to guidelines and with no deviation, this is the pre-stress achieved expressed as % of yield point.
µth= thread friction coefficient
µh = under head friction coefficient Thread friction coefficients have theoretical values but are verified through testing. Under head friction coefficients have been established by tests.
Torque guidelines for other bolt grades are available through your local Nord-Lock representative.
Nord-Lock steel washers with non-plated bolt grade 12.9 Nord-Lock steel washers with non-plated bolt grade 10.9 1 N = 0,225 lb 1 Nm = 0,738 ft-lb Oil, GF=75%
µth=0,15, µh=0,19 Cu/C paste, GF=75%
µth=0,13, µh =0,18 Dry, GF=62%
µth=0,18, µh=0,2 Washer size Bolt size Pitch
[mm]
[Nm]
Clamp load [kN]
[Nm]
Clamp load [kN]
[Nm]
Clamp load [kN]
Washer size Bolt size Pitch
[mm]
Oil, GF=71%
µth=0,15, µh =0,15 Cu/C paste, GF=75%
µth=0,13, µh=0,15 Torque
[Nm]
Clamp load
[kN]
[Nm]
Clamp load
[kN]
Washer size Bolt size Pitch
[mm]
Oil, GF=71%
µth=0,15, µh=0,13 Cu/C paste, GF=75%
µth=0,13, µh =0,14 Torque
[Nm]
Clamp load
[kN]
[Nm]
Clamp load
[kN]
NL3 M3 0,5 1,7 2,4 1,5 2,4 1,5 2,0 NL4 M4 0,7 3,8 4,2 3,6 4,2 3,5 3,5 NL5 M5 0,8 7,5 6,8 6,9 6,8 6,8 5,6 NL6 M6 1,0 13 9,7 12,1 9,7 12 8,0 NL8 M8 1,25 32 18 29 18 29 15 NL10 M10 1,5 62 28 57 28 56 23 NL12 M12 1,75 107 40 99 40 97 33 NL14 M14 2,0 170 55 157 55 155 46 NL16 M16 2,0 260 75 240 75 237 62 NL18 M18 2,5 364 92 336 92 331 76 NL20 M20 2,5 510 118 470 118 464 97 NL22 M22 2,5 696 146 642 146 634 120 NL24 M24 3,0 878 169 809 169 800 140 NL27 M27 3,0 1284 221 1183 221 1172 182 NL30 M30 3,5 1750 269 1613 269 1596 222 NL33 M33 3,5 2360 333 2173 333 2155 275 NL36 M36 4,0 3043 392 2803 392 2776 324 NL39 M39 4,0 3931 468 3619 468 3589 387 NL42 M42 4,5 4860 538 4476 538 4436 445 NL3 M3 0,5 2,2 3,9 2,3 4,1 NL4 M4 0,7 5,1 6,7 5,3 7,1 NL5 M5 0,8 10,0 10,9 10,3 11,5 NL6 M6 1,0 17,4 15,4 18 16,3 NL8 M8 1,25 42 28 43 30 NL10 M10 1,5 82 44 85 47 NL12 M12 1,75 142 65 146 68 NL14 M14 2,0 226 89 233 94 NL16 M16 2,0 345 120 355 127 NL18 M18 2,5 483 148 498 156 NL20 M20 2,5 676 188 696 198 NL22 M22 2,5 921 233 948 246 NL24 M24 3,0 1165 270 1199 286 NL27 M27 3,0 1700 352 1749 372 NL30 M30 3,5 2316 430 2386 454 NL33 M33 3,5 3124 532 3213 562 NL36 M36 4,0 4029 626 4145 662 NL39 M39 4,0 5199 748 5346 790 NL42 M42 4,5 6434 860 6617 908 NL3 M3 0,5 2,0 3,2 2,0 3,4 NL4 M4 0,7 4,5 5,6 4,5 5,9 NL5 M5 0,8 8,9 9,1 8,9 9,6 NL6 M6 1,0 15,5 12,9 15,5 13,6 NL8 M8 1,25 37 23 37 25 NL10 M10 1,5 73 37 73 39 NL12 M12 1,75 126 54 126 57 NL14 M14 2,0 201 74 201 78 NL16 M16 2,0 307 100 306 106 NL18 M18 2,5 430 123 429 130 NL20 M20 2,5 602 156 600 165 NL22 M22 2,5 821 194 818 205 NL24 M24 3,0 1036 225 1034 238 NL27 M27 3,0 1514 294 1509 310 NL30 M30 3,5 2064 358 2058 378 NL33 M33 3,5 2782 443 2772 468 NL36 M36 4,0 3589 522 3576 551 NL39 M39 4,0 4632 624 4613 659 NL42 M42 4,5 5731 716 5709 757
Øo
Øi T
Nord-Lock stainless steel washers EN 1.4404 (AISI 316L) or equivalent, surface hardened Thread friction coefficients have theoretical values but are verified through testing. Under head friction coefficients have been established by tests. Torque guidelines for other bolt grades are available through your local Nord-Lock representative.
EN 1.4404 is an austenitic chromium-nickel stainless steel containing molybdenum.
This stainless steel also has extra low carbon content in order to reduce the risk of chromium-carbide precipitation. EN 1.4404 is one of the most commonly used stainless steel grades and Nord-Lock washers made of EN 1.4404 are suitable for most applications where no chlorides or acids are present.
Cu/C paste = Copper/graphite paste (Molykote 1000)
GF= ratio of yield point. When tightening according to guidelines and with no deviation, this is the pre-stress achieved expressed as % of yield point.
µth= thread friction coefficient
µh= under head friction coefficient 1 N = 0,225 lb 1 Nm = 0,738 ft-lb Washer size Bolt size
øi
[mm]
øo
[mm]
Thickness T
[mm]
Min.
package
[pairs]
Approx.
weight kg / 100 pairs Metric UNC A4-70, Cu/C paste, GF=65%, µth=0,13, µh=0,13 A4-80, Cu/C paste, GF=65%, µth=0,13, µh=0,13 Washer size Bolt size Pitch
[mm]
[Nm]
Clamp load
[kN]
[Nm]
Clamp load
[kN]
- Please consult our website for current dimensions and 2D / 3D CAD models: www.nord-lock.com/cad 10 Nord-Lock washers made of stainless steel are standard stock items, yet subject to prior sale.
Torque guidelines Nord-Lock stainless steel washers with stainless steel bolt, lubricated with copper/graphite paste (Molykote 1000).
Dimension chart NL3ss - NL8ss
Øi+/-0,1 mm NL10ss - NL42ss
Øi+/-0,2 mm NL45ss - NL80ss
Øi+0,5 / -0,0 mm NL3ss - NL24ss
Øo+/-0,2 mm NL27ss - NL42ss
Øo+/-0,3 mm NL45ss - NL80ss
Øo+0,0 / -2,0 mm NL3ss - NL24ss T+/-0,25 mm NL27ss - NL42ss T+0,0 / -0,5 mm NL45ss - NL80ss T+/-0,75 mm NL3ss M3
- 5 3,4 7,0 2,2 200 0,04 NL3,5ss M3,5
- 6 3,9 7,6 2,2 200 0,04 NL3,5spss M3,5
- 6 3,9 9,0 2,2 200 0,07 NL4ss M4
- 8 4,4 7,6 2,2 200 0,04 NL4spss M4
- 8 4,4 9,0 2,2 200 0,07 NL5ss M5
- 10 5,4 9,0 2,2 200 0,06 NL5spss M5
- 10 5,4 10,8 2,2 200 0,11 NL6ss M6 6,5 10,8 2,2 200 0,09 NL6spss M6 6,5 13,5 2,0 200 0,16 NL1/4ss 1/4 7,2 11,5 2,2 200 0,09 NL1/4spss 1/4 7,2 13,5 2,2 200 0,15 NL8ss M8 5/16 8,7 13,5 2,0 200 0,12 NL8spss M8 5/16 8,7 16,6 2,0 200 0,23 NL3/8ss 3/8 10,3 16,6 2,0 200 0,19 NL3/8spss 3/8 10,3 21,0 2,0 200 0,38 NL10ss M10 10,7 16,6 2,0 200 0,18 NL10spss M10 10,7 21,0 2,0 200 0,37 NL11ss M11 7/16 11,4 18,5 2,2 200 0,26 NL12ss M12 13,0 19,5 2,0 200 0,23 NL12spss M12 13,0 25,4 3,0 100 0,82 NL1/2ss 1/2 13,5 19,5 2,0 200 0,22 NL1/2spss 1/2 13,5 25,4 3,2 100 0,80 NL14ss M14 9/16 15,2 23,0 3,0 100 0,49 NL14spss M14 9/16 15,2 30,7 3,2 100 1,31 NL16ss M16 5/8 17,0 25,4 3,0 100 0,59 NL16spss M16 5/8 17,0 30,7 3,2 100 1,13 NL18ss M18 19,5 29,0 3,2 100 0,80 NL18spss M18 19,5 34,5 3,2 100 1,56 NL3/4ss 3/4 20,0 30,7 3,2 100 0,96 NL3/4spss 3/4 20,0 39,0 3,2 100 2,10 NL20ss M20 21,4 30,7 3,0 100 0,82 NL20spss M20 21,4 39,0 3,2 100 2,06 NL22ss M22 7/8 23,4 34,5 3,2 100 1,23 NL22spss M22 7/8 23,4 42,0 3,2 50 2,22 NL24ss M24 25,3 39,0 3,2 100 1,59 NL24spss M24 25,3 48,5 3,2 50 3,50 NL1ss 1
27,9 39,0 3,2 100 1,42 NL1spss 1
27,9 48,5 3,2 50 2,79 NL27ss M27 28,4 42,0 6,8 50 3,45 NL27spss M27 28,4 48,5 6,8 25 5,34 NL30ss M30 1 1/8 31,4 47,0 6,8 50 4,49 NL30spss M30 1 1/8 31,4 58,5 6,8 25 9,18 NL33ss M33 1 1/4 34,4 48,5 6,8 25 4,28 NL36ss M36 1 3/8 37,4 55,0 6,8 25 5,96 NL39ss M39 1 1/2 40,4 58,5 6,8 25 6,74 NL42ss M42 43,2 63,0 6,8 25 7,50 NL45ss M45 1 3/4 46,2 70,0 6,8 25 10,20 NL48ss M48 49,6 75,0 6,8 25 12,00 NL52ss M52 2
53,6 80,0 9,0 1
18,04 NL56ss M56 2 1/4 59,1 85,0 9,0 1
21,30 NL60ss M60 63,1 90,0 9,0 1
23,50 NL64ss M64 2 1/2 67,1 95,0 9,0 1
25,80 NL68ss M68 71,1 100,0 9,0 1
28,20 NL72ss M72 75,1 105,0 9,0 1
30,70 NL76ss M76 3
79,1 110,0 9,0 1
33,30 NL80ss M80 3 1/8 83,1 115,0 9,0 1
36,00 NL3ss M3 0,5 0,8 1,5 1,1 2,0 NL4ss M4 0,7 1,8 2,6 2,4 3,4 NL5ss M5 0,8 3,6 4,1 4,8 5,5 NL6ss M6 1,0 6,3 5,9 8,4 7,8 NL8ss M8 1,25 15 11 20 14 NL10ss M10 1,5 30 17 39 23 NL12ss M12 1,75 51 25 68 33 NL14ss M14 2,0 81 34 108 45 NL16ss M16 2,0 124 46 165 61 NL18ss M18 2,5 173 56 231 75 NL20ss M20 2,5 243 72 323 95 NL22ss M22 2,5 330 89 440 118 NL24ss M24 3,0 418 103 557 137 NL27ss M27 3,0 609 134 812 179 NL30ss M30 3,5 831 164 1108 219 NL36ss M36 4,0 1444 239 1925 319
Øo
Øi T
Nord-Lock 254 SMO washers EN 1.4547 or equivalent, surface hardened Dimension chart Thread friction coefficients have theoretical values but are verified through testing. Under head friction coefficients have been established by tests. Torque guidelines for other bolt grades are available through your local Nord-Lock representative.
254 SMO is a high performance austenitic stainless steel (according to EN 1.4547) with greater mechanical strength and resistance against corrosion than most austenitic stainless steel grades. The material is resilient against pitting and crevice corrosion due to high contents of chromium, nickel, molybdenum and nitrogen.
Nord-Lock 254 SMO washers are specially designed for chloride rich processes and salt water solutions / atmospheres, i.e. environments where stainless steel washers made of EN 1.4404 are not suitable.
Washer size Bolt size
øi
[mm]
øo
[mm]
Thickness T
[mm]
Min.
package
[pairs]
Approx weight kg / 100 pairs Metric UNC A4-70, Cu/C paste, GF=65%, µth=0,13, µh=0,13 A4-80, Cu/C paste, GF=65%, µth=0,13, µh=0,13 Washer size Bolt size Pitch
[mm]
[Nm]
Clamp load
[kN]
[Nm]
Clamp load
[kN]
- Please consult our website for current dimensions and 2D / 3D CAD models: www.nord-lock.com/cad 11 Nord-Lock washers made of 254 SMO quality are standard stock items, yet subject to prior sale.
Cu/C paste = Copper/graphite paste (Molykote 1000)
GF= ratio of yield point. When tightening according to guidelines and with no deviation, this is the pre-stress achieved expressed as
% of yield point.
µth= thread friction coefficient
µh= under head friction coefficient 1 N = 0,225 lb 1 Nm = 0,738 ft-lb Torque guidelines Nord-Lock 254 SMO washers with stainless steel bolt, lubricated with copper/graphite paste (Molykote 1000).
NL3ss-254
-NL8ss-254
Øi+/-0,1 mm NL10ss-254
-NL39ss-254
Øi+/-0,2 mm NL3ss254
-NL24ss -254
Øo+/-0,2 mm NL27ss-254
-NL39ss-254
Øo+/-0,3 mm NL3ss-254
-NL39ss-254 T+/-0,25 mm NL3ss-254 M3 0,5 0,8 1,5 1,1 2,0 NL4ss-254 M4 0,7 1,8 2,6 2,4 3,4 NL5ss-254 M5 0,8 3,6 4,1 4,8 5,5 NL6ss-254 M6 1,0 6,3 5,9 8,4 7,8 NL8ss-254 M8 1,25 15 11 20 14 NL10ss-254 M10 1,5 30 17 39 23 NL12ss-254 M12 1,75 51 25 68 33 NL14ss-254 M14 2,0 81 34 108 45 NL16ss-254 M16 2,0 124 46 165 61 NL18ss-254 M18 2,5 173 56 231 75 NL20ss-254 M20 2,5 243 72 323 95 NL22ss-254 M22 2,5 330 89 440 118 NL24ss-254 M24 3,0 418 103 557 137 NL27ss-254 M27 3,0 609 134 812 179 NL30ss-254 M30 3,5 831 164 1108 219 NL36ss-254 M36 4,0 1444 239 1925 319 NL3ss-254 M3
- 5 3,4 7,0 2,2 200 0,04 NL3,5ss-254 M3,5
- 6 3,9 7,6 2,2 200 0,04 NL3,5spss-254 M3,5
- 6 3,9 9,0 2,2 200 0,07 NL4ss-254 M4
- 8 4,4 7,6 2,2 200 0,04 NL4spss-254 M4
- 8 4,4 9,0 2,2 200 0,07 NL5ss-254 M5
- 10 5,4 9,0 2,2 200 0,06 NL5spss-254 M5
- 10 5,4 10,8 2,2 200 0,11 NL6ss-254 M6 6,5 10,8 2,2 200 0,09 NL6spss-254 M6 6,5 13,5 2,0 200 0,16 NL1/4"-254 1/4" 7,2 11,5 2,2 200 0,09 NL1/4"spss-254 1/4" 7,2 13,5 2,2 200 0,15 NL8ss-254 M8 5/16" 8,7 13,5 2,0 200 0,12 NL8spss-254 M8 5/16" 8,7 16,6 2,2 200 0,22 NL3/8"ss-254 3/8" 10,3 16,6 2,0 200 0,19 NL3/8"spss-254 3/8" 10,3 21,0 2,2 200 0,38 NL10ss-254 M10 10,7 16,6 2,0 200 0,18 NL10spss-254 M10 10,7 21,0 2,2 200 0,37 NL11ss-254 M11 7/16" 11,4 18,5 2,2 200 0,26 NL12ss-254 M12 13,0 19,5 2,0 200 0,23 NL12spss-254 M12 13,0 25,4 3,2 100 0,83 NL1/2"ss-254 1/2" 13,5 19,5 2,0 200 0,23 NL1/2"spss-254 1/2" 13,5 25,4 3,0 100 0,80 NL14ss-254 M14 9/16" 15,2 23,0 3,0 100 0,49 NL14spss-254 M14 9/16" 15,2 30,7 3,0 100 1,13 NL16ss-254 M16 5/8" 17,0 25,4 3,0 100 0,59 NL16spss-254 M16 5/8" 17,0 30,7 3,2 100 1,13 NL18ss-254 M18 19,5 29,0 3,2 100 0,80 NL18spss-254 M18 19,5 34,5 3,2 100 1,56 NL3/4"ss-254 3/4" 20,0 30,7 3,2 100 0,96 NL3/4"spss-254 3/4" 20,0 39,0 3,2 100 2,14 NL20ss-254 M20 21,4 30,7 3,0 100 0,83 NL20spss-254 M20 21,4 39,0 3,2 100 1,98 NL22ss-254 M22 7/8" 23,4 34,5 3,2 100 1,19 NL22spss-254 M22 7/8" 23,4 42,0 3,2 50 2,44 NL24ss-254 M24 25,3 39,0 3,2 100 1,65 NL24spss-254 M24 25,3 48,5 3,2 50 3,50 NL1"ss-254 1"
27,9 39,0 3,2 100 1,42 NL1"spss-254 1"
27,9 48,5 5,8 50 5,40 NL27ss-254 M27 28,4 42,0 5,8 50 3,10 NL27spss-254 M27 28,4 48,5 5,8 25 5,34 NL30ss-254 M30 1 1/8" 31,4 47,0 5,8 50 4,04 NL33ss-254 M33 1 1/4" 34,4 48,5 5,8 25 3,86 NL36ss-254 M36 1 3/8" 37,4 55,0 5,8 25 5,50 NL39ss-254 M39 1 1/2" 40,4 58,5 5,8 25 6,74
12 Nord-Lock washers joint guide Tapped holes Nord-Lock washers safely lock the bolt against the underlying surface.
Stud bolts Nord-Lock washers safely lock the nut on stud bolts and eliminate the need for adhesives.
Through holes As for all locking washers, through holes require two pairs of Nord-Lock washers - one pair for securing the bolt and a second pair for securing the nut.
Turn both fasteners in order to close the cams on both washer pairs before tightening to minimize settlements. Keep the nut secure whilst tightening the bolt.
Counter bores The outer diameter of regular Nord-Lock washers is designed for counter-bore holes according to DIN 974, i.e. the washers fit under the head of standard bolts.
Applications with large / slotted holes or soft underlying surfaces To optimize the load distribution for applications with large / slotted holes or with soft underlying surface, use a flanged nut / bolt together with Nord-Lock sp washers with enlarged outer diameter.
Soft underlying surfaces Large / slotted holes If your application corresponds to one or more of the above mentioned design criteria, contact your Nord-Lock representative and we will help you find an alternative solution.
Designs where Nord-Lock washers are not recommended
- Mating surfaces that are not locked in place (see left figure)
- Mating surfaces harder than the washers
- Very soft mating surface, e.g. wood, plastic
- Applications with extremely large settlements
- Non-preloaded joints
13 Nord-Lock sp washers on painted surface.
Nord-Lock sp washers on soft metal.
Nord-Lock sp washers on fibre surface.
Nord-Lock sp (enlarged outer diameter) washers Nord-Lock washers are available with an enlarged outer diameter, referred to as sp washers. sp washers are designed for use on large / slotted holes, painted / sensitive surfaces or soft materials. Use Nord-Lock sp washers with flanged bolts or nuts for optimum load distribution.
Ø inner regular = Ø inner sp
Ø outer regular < Ø outer sp Uniform friction with Nord-Lock washers When using Nord-Lock washers, sliding always occurs between the upper washer and the bolt head / nut. At a given torque, the preload will be the same, regardless of the contact material.
Nord-Lock provides customized torque guidelines for your application, contact your nearest representative.
Untightening Regular nut M8 on aluminium without washer Regular nut M8 on steel without washer Torque [Nm]
Tightening Load [kN]
Regular nut M8 on aluminium with Nord-Lock washers Regular nut M8 on steel with Nord-Lock washers Torque [Nm]
Tightening Untightening By using sp washers, the load is distributed over a larger surface which can be more gentle for sensitive surfaces. Please consult Nord-Lock to find the optimal solution for your application.
A flanged nut and Nord-Lock sp washers increase the load
supporting surface for
applications with slotted holes.
It is important to have control over the friction conditions in order to obtain the desired preload when tightening a joint.
When no washer is used under the fastener, the friction depends on the contact surface. At a given torque, the obtained preload will vary depending on the contact material.
Load [kN]
14 Nord-Lock wedge-locking Nord-Locks innovative and multiple award-winning X-series washers provide maximum security for critical bolted joints that are exposed to spontaneous bolt loosening and slackening. Nord-Lock has also developed the SC-washers which increase the security for steel construction and are designed for HV/HR sets.
Customer unique solutions Over the years, the Nord-Lock Group has entered several partnerships to develop unique solutions for the most creative designs. Let us help you find the optimum solution for your specific requirements.
Your partner for bolting solutions Multi-jackbolt tensioning Superbolt multi-jackbolt tensioning is an innovative technology for tightening of medium to large bolts and studs. The method is simple, accurate and cost effective.
Only hand tools are required to tighten even the largest of bolts. Superbolt tensioners can be threaded onto a new or existing bolt, stud, threaded rod or shaft.
Expansion bolting Superbolt Expansion bolts replace traditional interference or force fit bolts. They offer tremendous radial expansion and joint clamping power in one bolting system. Radial expansion is critical for rotating couplings or alignment systems that require the bolts to be able to handle transfer of forces in shear. Expansion bolts are available for blind hole and through hole applications.
The Nord-Lock Group is continuously developing new innovative solutions. In addition to the Nord-Lock washers, our product offering consists of several technologies, all developed and designed in-house. Contact us to learn more about our current range of products or please visit www.nord-lock.com Hydraulic bolt tensioning Boltight bolt tensioning tools are used all over the world, from the high performance standard tool range to the uniquely designed tools to suit market and application requirements. The tools are lightweight, compact and easy to use with a focus on safe operation and product quality.
Products include hydraulic bolt tensioners, subsea bolt tensioners, hydraulic nuts, echometer and more.
15 Performance Services Nord-Lock Performance Services will assist you in identifying ways which your company can increase its competitiveness.
A Performance Services project can be initiated to solve a specific problem; alternatively the goal can be to create an overview of possible improvements. Each project is designed to meet customer specific needs and challenges. We can investigate current applications as well as future designs.
Presence in your market The Nord-Lock Group includes subsidiaries, in-house laboratories on three continents, and a worldwide network of authorized distributors. Our philosophy is to be close to our customers, to speak your language and to help you achieve secure and effective bolted joints. To find the complete list of Nord-Lock representatives, please go to www.nord-lock.com/contact Nord-Lock global chain of services Joint calculation and simulation. Real life testing and validation. Custom designs.
Design / Production Application Engineers, Technical Centers & Project Engineering Aftermarket On-site and remote product training as well as service and retrofitting Increasing the knowledge for operators and engineers. Installation support.
Cost savings generated by optimized bolted joints.
Sourcing Life Cycle Profitability and cost justification Reliability Rationalisation Productivity Profits
English
- Revised, not printed
- 2017-03
- 70025EN Nord-Lock Group Tel:+46 40 602 46 00 Email:info@nord-lock.com www.nord-lock.com When safety really matters Joining parts together is one of the most critical steps when delivering a product or system. The Nord-Lock Group is focused on solving the toughest bolting challenges. We offer a unique combination of bolting expertise and a wide product range, including wedge-locking technology and Superbolt tensioners all designed and developed in-house.
Nord-Lock holds decades of documented success in every major industry, including oil and gas, energy, transportation and mining. Our Production System includes rigorous internal testing and full traceability, and our products hold several certificates from independent institutes including ABS, DIBt, DNV and TÜV.
The tools available through Nord-Lock Performance Services add value throughout a project and ensure that your bolting application pays back multiple times. We can also assist you in the design phase with joint simulation and testing.
Additionally, we help you ensure successful operations over time with our onsite support and remote product training.
Our mission is to safeguard human lives and customer investments by securing the worlds most demanding applications. The Nord-Lock Group looks forward to being your partner in bolting solutions.