Other: ML19088A181, ML19088A182, ML19088A183, ML19088A184, ML19170A222, ML19170A227, ML19170A228, ML19170A229, ML19170A230, ML19170A232, ML19170A233, ML19200A132, ML19200A133, ML19200A134, ML19200A135, ML19200A136, ML19203A265, ML19203A266, ML19249B070, ML19290E730, ML19290E739, ML19290E743, ML19290E745
|
MONTHYEARML19088A1812013-08-18018 August 2013 Criticality Safety of Enriched UF6 Cylinders Project stage: Other ML19088A1822013-08-18018 August 2013 Regulatory Criticality Safety Review of Uranium Hexafluoride Transport Package Applications Project stage: Other ML19088A1842013-08-18018 August 2013 Criticality Analyses of Enriched Uranium-Hexafluoride Containing Impurities Project stage: Other ML19088A1832016-09-18018 September 2016 Hydration of Uranium Residues Contained in Enriched UF6 Cylinders Project stage: Other ML18282A0892018-09-10010 September 2018 Daher - Application for Withholding Proprietary Information from Public Disclosure Project stage: Request ML18282A0882018-09-10010 September 2018 Daher - Supplemental Information for the Review of the Model No. DN30 Package Project stage: Supplement ML18264A1322018-09-20020 September 2018 Package: Letter to F. Hilbert Request for Supplemental Information for the Review of the Model No. DN30 Package Project stage: Request ML18264A1342018-09-20020 September 2018 Letter to F. Hilbert Request for Supplemental Information for the Review of the Model No. DN30 Package Project stage: Approval ML18264A1332018-09-20020 September 2018 Enclosurequest for Supplemental Information (Letter to F. Hilbert Request for Supplemental Information for the Review of the Model No. DN30 Package) Project stage: Approval ML19070A0022019-03-0707 March 2019 Letter to F. Hilbert Request for Additional Information for the Review of the Model No. DN-30 Package (W/Enclosure) Project stage: RAI ML19066A2162019-03-0707 March 2019 Notice of Public Meeting with Daher Nuclear Technologies Gmbh (Daher) to Discuss Proposed Responses to the Request for Additional Information for the Model No. DN-30 Package Project stage: RAI ML19088A1782019-03-29029 March 2019 Application for Withholding Proprietary Information from Public Disclosure Project stage: Request ML19088A1752019-03-29029 March 2019 Daher Nuclear Technologies Gmbh, Request for Additional Information for the Review of the Model No. DN30 Package Project stage: Request ML19088A1762019-03-29029 March 2019 0023-BAR-2019-001 Answers to the Request for Additional Information Project stage: Request ML19120A0292019-04-30030 April 2019 Daher Nuclear Technologies Gmbh - Request for Extension of the Deadline to Provide the Additional Information Requested in Letter Dated March 7, 2019 Project stage: Request ML19123A2082019-05-0303 May 2019 Memorandum to C. Regan Summary of April 16, 2019, Meeting with Daher Nuclear Technologies (W/Enclosure) Project stage: Meeting ML19170A2322019-06-19019 June 2019 Technical Information Sheet - 50/50 Tin Lead Solder Project stage: Other ML19170A2272019-06-19019 June 2019 Proceedings of the 17th International Symposium on the Packaging and Transportation of Radioactive Materials Patram 2013, August 18-23, 2013, San Francisco, CA, USA - Criticality Safety of Enriched UF6 Cylinders Project stage: Other ML19170A2282019-06-19019 June 2019 Proceedings of the 17th International Symposium on the Packaging and Transportation of Radioactive Materials Patram 2013, Aug 18-23San Francisco, CA, USA - Regulatory Criticality Safety Review of Uranium Hexafluoride Transport Package Appli Project stage: Other ML19170A2232019-06-19019 June 2019 0023-BAR-2019-001-Rev1 - Response to Request for Additional Information Project stage: Response to RAI ML19170A2312019-06-19019 June 2019 Daher Nuclear Technologies Gmbh - Response to Request for Additional Information Project stage: Response to RAI ML19170A2292019-06-19019 June 2019 Proceedings of the 18th International Symposium on the Packaging and Transportation of Radioactive Materials Patram 2016 September 18-23, 2016, Kobe, Japan - Hydration of Uranium Residues Contained in Enriched UF6 Cylinders Project stage: Other ML19170A2332019-06-19019 June 2019 Nord-Lock Group - Slides Project stage: Other ML19170A2222019-06-19019 June 2019 Daher Nuclear Technologies Gmbh - Affidavit Project stage: Other ML19170A2302019-06-19019 June 2019 Proceedings of the 17th International Symposium on the Packaging and Transportation of Radioactive Materials Patram 2013 August 18-23, 2013, San Francisco, CA, USA - Criticality Analyses of Enriched Uranium-Hexafluoride Containing Impuritie Project stage: Other ML19200A1332019-07-12012 July 2019 0023-PA-2015-016, Rev. 3, Safety Analysis Report DN30 Package Project stage: Other ML19200A1362019-07-19019 July 2019 0023-PA-2015-016, Rev. 3, Inspection Criteria for Regular and Periodical Inspections of the DN30 Package Project stage: Other ML19200A1342019-07-19019 July 2019 0023-HA-2015-001, Rev. 4, Use and Handling of the DN30 Package Project stage: Other ML19200A1322019-07-19019 July 2019 Daher Nuclear Technologies Gmbh - Submittal of Final SAR for the Review of the Model No. DN30 Package Project stage: Other ML19200A1352019-07-19019 July 2019 0023-PA-2015-015, Rev. 3, Periodical Inspections of the DN30 Psp Project stage: Other ML19203A2662019-07-25025 July 2019 Enclosure 1: CoC No. 9362, Rev. No. 0 (Letter to F. Hilbert Certificate of Compliance No. 9362, Revision No. 0, for the Model No. DN30 Package (W/Enclosure 2)) Project stage: Other ML19203A2642019-07-25025 July 2019 Package: Certificate of Compliance No. 9362, Revision No. 0, for the Model No. DN30 Package Project stage: Request ML19203A2652019-07-25025 July 2019 Letter to F. Hilbert Certificate of Compliance No. 9362, Revision No. 0, for the Model No. DN30 Package (W/Enclosure 2) Project stage: Other ML19249B0702019-08-26026 August 2019 Daher Nuclear Technologies Gmbh - 0023-HA-2015-001-Rev 5, Use and Handling of the DN30 Package Project stage: Other ML19290E7452019-10-10010 October 2019 Daher Nuclear Technologies Gmbh, 0023-PA-2015-016, Rev. 4, Inspection Criteria for Regular and Periodical in, Inspections of the DN30 Package Project stage: Other ML19290E7392019-10-10010 October 2019 Daher Nuclear Technologies Gmbh, 0023-HA-2015-001, Rev. 6, Use and Handling of the DN30 Package Project stage: Other ML19290E7432019-10-11011 October 2019 Daher Nuclear Technologies Gmbh, 0023-PA-2015-015, Rev. 4, Periodical Inspections of the DN30 Psp Project stage: Other ML19290E7322019-10-17017 October 2019 Daher Nuclear Technologies Gmbh, Application for Withholding Proprietary Information from Public Disclosure Submittal of Document: Design Change of the DN30 Package Project stage: Request ML19290E7302019-10-17017 October 2019 Daher Nuclear Technologies Gmbh, Securing Bolt of the Closure Devices of the DN30 PSP Project stage: Other 2019-03-29
[Table View] |
Text
TECHNICAL INFORMATION SHEET 50/50 TIN LEAD SOLDER THE HARRIS PRODUCTS GROUP A LINCOLN ELECTRIC COMPANY 4501 Quality Place
- Mason, OH 45040 U.S.A Tel: 513-754-2000 Fax: 513-754-6015 Additional information available at our web site: www.harrisproductsgroup.com MK Revised 02/17 NOMINAL CHEMICAL COMPOSITION%:
TYPICAL PHYSICAL PROPERTIES:
Solidus 361ºF (183°C)
Liquidus 421°F (216°C)
SOLDERING PROPERTIES:
With some exceptions, the tin lead solders can be used to solder copper and most copper alloys, lead, nickel alloys, and steel. 50/50 solder is used for general purpose soldering applications including sheet metal work. Tin lead solders are not recommended in high stress or vibration joints in the cooling industry due to lack of sufficient elongation properties. Heat sources include soldering guns, irons, and air-fuel torches.
Lead bearing solders are not to be used in potable water systems.
AVAILABLE FORMS Standard wire diameters RECOMMENDED FLUX:
Stay Clean soldering fluxes are recommended except on electrical or electronic applications which require the use of a non-corrosive rosin flux. Remove all flux residues after soldering.
SPECIFICATION COMPLIANCE:
ASTM B32 Alloy Grade Sn 50 J-STD-006 Sn50Pb50Sb0.4 SAFETY INFORMATION:
WARNING: PROTECT yourself and others. Read and understand this information.
FUMES AND GASES can be hazardous to your health.
HEAT RAYS, (infrared radiation) from flame or hot metal can injure eyes.
Before use, read and understand the manufacturers instructions, Safety Data Sheets (SDS), and your employer's safety practices.
Keep your head out of fumes.
Use enough ventilation, exhaust at the flame, or heat source, to keep fumes and gases from your breathing zone and the general area.
Wear correct eye, ear, and body protection.
See American National Standard Z49.1, Safety in Welding, Cutting, and Allied Processes, published by the American Welding Society, 8669 Doral Blvd., Doral, Florida 33166; OSHA Safety and Health Standards, available from the U.S.
Government Office, Washington, DC 20402.
STATEMENT OF LIABILITY-DISCLAIMER:
Any suggestion of product applications or results is given without representation or warranty, either expressed or implied. Without exception or limitation, there are no warranties of merchantability or of fitness for particular purpose or application. The user must fully evaluate every process and application in all aspects, including suitability, compliance with applicable law and non-infringement of the rights of others. The Harris Products Group and its affiliates shall have no liability in respect thereof.
Lead Remainder Tin Antimony 49.5-51.5 0.20 - 0.50