ML19154A287

From kanterella
Jump to navigation Jump to search
4 to Updated Final Safety Analysis Report, Chapter 6, Engineered Safeguards Systems, Tables
ML19154A287
Person / Time
Site: Palisades 
(DPR-020)
Issue date: 05/23/2019
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19154A338 List: ... further results
References
PNP 2019-015
Download: ML19154A287 (23)


Text

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-1 Revision 21 Page 1 of 1 SAFETY INJECTION AND REFUELING WATER TANK DESIGN PARMETERS Nominal Volume 285,000 Gallons Contained Liquid Boric Acid (1,720-2,500ppm)

Minimum During Operation 250,000 Gallons Liquid Temperature 40°F-105°F Diameter/Height 46 Feet/24 Feet Material Aluminum Design Temperature 125°F Design Pressure Atmospheric

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-2 Revision 24 Page 1 of 1 LOW PRESSURE SAFETY INJECTION PUMP DATA

SUMMARY

Quantity 2

Type Single Stage, Horizontal, Centrifugal Design Pressure 500 psig Design Temperature 350°F Design Flow Rate 3,000 gpm Design Head 350 ft Pumped Fluid 1% Boric Acid, Nominal

<15,000 ppm Boric Acid, Maximum (Design)

Temperature of Pumped Fluid 40° - 325°F Shutoff Head 410 ft Maximum Flow 4,500 gpm Head at Maximum Flow 250 ft Basic Material 316 SS (see Table 6-10)

Horsepower 400 Seals Mechanical Acceleration Time 4 Seconds Minimum Flow 163 gpm NPSH Required at 3,000 gpm 11 ft Maximum Normal Suction Pressure 270 psia

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-3 Revision 24 Page 1 of 1 HIGH PRESSURE SAFETY INJECTION PUMP DATA

SUMMARY

Quantity 2

Type Multistage, Horizontal, Centrifugal Design Pressure 1,750 psig Design Temperature 350°F Design Flow Rate 300 gpm Design Head 2,500 ft Pumped Fluid 1% Boric Acid, Nominal

<15,000 ppm Boric Acid, Maximum (Design)

Temperature of Pumped Fluid 40° - 300°F Shutoff Head 2,800 ft Maximum Flow 680 gpm Head at Maximum Flow 850 ft Material Stainless Steel Horsepower 400 Shaft Seal Mechanical Acceleration Time 4 Seconds Normal/Minimum Recirc Flow 30 gpm/25 gpm NPSH Required at 600 gpm 17 ft Maximum Suction Pressure 250 psig

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-4 Revision 21 Page 1 of 2 SHUTDOWN COOLING HEAT EXCHANGER DATA

SUMMARY

Quantity 2

Type Shell and Tube Code ASME,Section III, Class C, 1965, TEMA, Class R Tube Side Fluid Primary Coolant, 1% Boric Acid, Nominal

<15,000 ppm Boric Acid, Maximum (Design)

Design Pressure 500 psig Design Temperature 400°F Pressure Loss, 1,500,000 lb/h 5 psi Materials Austenitic Stainless Steel Shell Side Fluid Component Cooling Water Design Pressure 150 psig Design Temperature 200°F Pressure Loss, 2,000,000 lb/h 10 psi Materials Carbon Steel Operating Parameters (27.5 Hours After Shutdown Assuming an Infinitely Irradiated Core)

Tube Side Flow 1,500,000 lb/h Inlet Temperature 130°F Outlet Temperature 111.7°F

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-4 Revision 21 Page 2 of 2 SHUTDOWN COOLING HEAT EXCHANGER DATA

SUMMARY

Shell Side Flow 2,000,000 lb/h Inlet Temperature 90°F Outlet Temperature 103.5°F Heat Transfer 27,500,000 Btu/h

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-5 Revision 21 Page 1 of 1 SAFETY INJECTION TANK DESIGN PARAMETERS Quantity 4

Type Vertical Right Cylinder Design Pressure 250 psig Design Temperature 200°F Liquid Volume (min/max) 1040/1176 ft3/Tank Combined Liquid Discharge 30,000 Gallons Pressuring Cover Gas Nitrogen Height 34 Feet 6 Inches Outside Diameter 9 Feet 2 Inches Material Carbon Steel With Type 304L Stainless Steel Clad Contained Liquid 1720 ppm Boric Acid, Nominal 15,000 ppm Boric Acid, Maximum (Design)

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-6 Revision 31 Page 1 of 3 CONTAINMENT SPRAY SYSTEM COMPONENT DESCRIPTION

1.

Containment Spray Pumps Number of Units - 3 Type Vertically Split, Horizontal Centrifugal With Mechanical Seals and Backup Packed Gland Material -

316 Stainless Steel Code Motor, NEMA; Pump, Standards of the Hydraulics Institute, 11th Edition, 1965, ASA B31.1-1955; ASA B16.5-1961 Injection Recirculation Design Capacity (Each) 1,340 gpm 1,800 gpm Design Head 450 ft 405 ft Design NPSH Required 13.2 ft 17.8 ft Temperature Transient 40° - 300°F in 5 Seconds Motor 250 hp, 3 Ph, 60 Hz, 2,300 V Pumps Acceleration Time 4 Seconds at 70% Voltage Pumped Fluid 1% Boric Acid, Nominal 15,000 ppm Boric Acid, Maximum (Design)

2.

Shutdown Cooling Heat Exchangers Number of Units - 2 Capacity (Each) 83.5 x 106 Btu/h Based on 4,000 gpm of Cooling Water at 114°F Inlet Temperature and 1,420 gpm of Spray Water at 283°F Inlet Temperature

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-6 Revision 31 Page 2 of 3 CONTAINMENT SPRAY SYSTEM COMPONENT DESCRIPTION

3.

Piping, Fittings and Valves A.

Suction Material - Type 304 Stainless Steel Pipe Sizes Wall Thickness 2" and Smaller Sch 40S 2-1/2" Through 12" Sch 10S 14" Through 20" 0.250" Nominal Wall 24" 0.375" Nominal Wall Design Pressure - 60 psig Design Temperature - 300°F Construction 2-1/2" and Larger Butt-Welded Except at Flanged Equipment 2" and Smaller Socket Welded Except at Screwed Equipment Valves 2" and Larger Stainless Steel, Butt-Welded, 150 lb 1-1/2" and Smaller Stainless Steel, Socket Welded, 150 lb Testing 100% Radiography of Welded Joints Code ASA B31.1-1955 and Code Cases N2 and N10 B.

Discharge Material - Type 304 Stainless Steel Pipe Sizes Wall Thickness 8" and Smaller Sch 40S 10" Through 14" 0.250" Nominal Wall Design Pressure - 500 psig Design Temperature - 350°F Valves 2" and Larger Stainless Steel, Butt-Welded, 300 lb 1-1/2" and Smaller Stainless Steel, Socket Welded, 600 lb Testing 100% Radiography of Welded Joints Code ASA B31.1-1955 and Code Cases N2 and N10

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-6 Revision 31 Page 3 of 3 CONTAINMENT SPRAY SYSTEM COMPONENT DESCRIPTION

4.

Spray Nozzles Type

- Sprayco, Model 1713A Material

- 304 Stainless Steel Number

- 77 Nozzles on A Spray Header

- 83 Nozzles on B Spray Header Maximum Spray Droplet Size

- 1800 microns at 16 psid (Mass Mean Diameter)

Capacity

- Refer to FSAR Figure 6-7

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-7 Revision 27 Page 1 of 2 CONTAINMENT AIR COOLER COMPONENT DESCRIPTION Coils (VHX-1, VHX-2 and VHX-3 Safety Related & VHX-4 Non-Safety)

Coils per Cooler Unit 4

Rows of Tubes per Coil 12 Face Area of Each Coil 20.54 ft2 Total Coil Face Area per Cooler Unit 82.16 ft2 Tubes per Row 36 Tube Description 5/8" OD Copper x 0.049" Wall Tube Design Pressure 150 psig Fin Description 3/8" High x.012 Thick Copper Plate with 9.4 Fins per Inch (Mechanical Bond)

Normal Pressure Drop Across Coil 1.54 in. wg (Air Side)

Maximum Pressure Drop Across Coil 1.68 in. wg (Air Side, Accident Condition)

Normal Pressure Drop Through Coil 16 ft H2o(Water Side)

Maximum Pressure Drop Through Coil 12.7 ft H2o(Water Side, Accident Condition)

Fans (V1, V2, V3 and V4)

Fan Speed 1,750 r/min Number of Fans per Cooler Unit 2

Fan Capacity (Each)

"A" 75 HP (accident) 30,000 ft3/min at 4.5" H2O "B" 30 HP (normal) 30,000 ft3/min at 4.0" H2O Total Airflow Through Cooler(Normal) 60,000 ft3/min Total Airflow Through Cooler(Accident) 30,000 ft3/min (VHX-1, 2 and 3)

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-7 Revision 27 Page 2 of 2 CONTAINMENT AIR COOLER COMPONENT DESCRIPTION Motor Design Totally Enclosed Air Overcooled Insulation NEMA Class H for Fans Rated for the Post-DBA Condition NEMA Class B for Fans Rated for Normal Duty Rating 75 hp for Fans Rated for the Post-DBA Condition 30 hp for Fans Rated for Normal Duty Filters (VF-1, VF-2, VF-3, VF-4)

Capacity 60,000 ft3/min at 0.33" H2O Differential Pressure Drop (Clean) 0.33" H2O Size of Each Filter Module 19.25" x 19.25" x 1.75" Thick Number of Filter Modules per Cooler Unit 32 Efficiency 65%

Type Stainless Steel Mesh, Framed

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-8 Revision 27 Page 1 of 1 CONTAINMENT AIR COOLERS PERFORMANCE DATA FOR NORMAL OPERATION VHX-1, VHX-2, and VHX-3 Coolers in Operation Total Heat Removal Capacity 5.94 x 106 Btu/h Total Airflow 180,000 ft3/min Total Motor hp (6 Fans) 315 bhp (nameplate)

Total Cooling Water Flow (Modulated) 1500-6000 gpm Air Temperature, Inlet/Outlet 115°F/83.5°F Water Temperature, Inlet 81.5°F Each Cooler, Capacity 1.98 x 106 Btu/h Airflow, Each Cooler 60,000 ft3/min (2 Fan Operation)

Cooling Water Flow, Each 500 gpm to 2000 gpm NOTE: The values above are for three coolers at assumed conditions only. Initial conditions for accident analyses are contained in Chapter 14.

VHX-4 Cooler in Operation Total Heat Removal Capacity 1.98 x 106 Btu/h Total Airflow 60,000 ft3/min Total Motor hp (2 Fans) 105 bhp (Nameplate)

Total Cooling Water Flow up to 2000 gpm (Nominal)

Air Temperature, Inlet/Outlet 115°F/84°F (Design)

Water Temperature, Inlet 81.5°F (Design)

NOTE: Although VHX-4's temperature control valve is failed closed, the cooler can be used for cooling during normal operation by opening its high-capacity outlet valve.

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-9 Revision 23 Page 1 of 1 CONTAINMENT AIR COOLERS PERFORMANCE DATA FOR POST-DBA CONDITIONS 3 Coolers Operating Total Heat Removal Capacity at 283°F, 55 psig 261.6 x 106 Btu/h Total Airflow (Cooler Design) 90,000 ft3/min Total Fan hp (3 Fans) 225 bhp (Nameplate)

Total Cooling Water Flow (3 Coolers)

Set per RO-216 Air Temperature, Inlet/Outlet 283°F/276°F Req. Water Temperature, Inlet/Outlet Based on Flow from RO-216 Each Cooler (VHX 1, 2, 3)

Capacity at 283°F, 55 psig 87.2 x 106 Btu/hr Airflow (Cooler Design) 30,000 ft3/min Coil Differential Pressure Drop (Air Side) 1.45" H2O Fan Differential Pressure 6.15" H2O TP Water Flow Set per RO-216 Water Side Differential Pressure Drop 5.5 psi Total Fan hp (1 Fan) 75 bhp (Nameplate)

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-10 Revision 23 Page 1 of 2 ECCS COMPONENT SYSTEMS Piping -

Stainless Steel-304 Valves -

Stainless Steel or other equivalent corrosion resistant material Gaskets - Asbestos or Grafoil Grade GTTMB (eg, Flexitallic or Flexicarb) with 300 Series SS Component LP Pump HP Pump Spray Pump Casing ASTM A351 SS, Mod CF8A ASTM A351 SS, Mod CF8 SS, CF8M Impeller ASTM A217 SS, CF8 ASME SA 351, Grade CA15 SS SS, CF8M Casing Wear Ring ASTM A479, Gr S21800 17-4 PH SS, CF8M Shaft A479, 316 SS AISI 416 316 SS Shaft Sleeve ASTM A479, 316 SS 316 SS Gland Seal 316 SS Pumping Ring P-67A - Internal to Seal Cartridge P-67B -

18-8 SS on Shaft Sleeve 18-8 SS Seal Cartridge 316 SS 316 SS 316 SS Face Seal Rotating Element Carbon 316 SS with Tungsten Carbide Carbon Face Seal Stationary Element P-67A - Silicon Carbide P-67B - Tungsten Carbide Carbon Tungsten Carbide Throttle Bushing P-67A - Bronze P-67B - Carbon Carbon Backup Ring Viton Valves and Piping 304 SS 304 SS 304 SS Gaskets Asbestos or Grafoil Grade GTTMB (eg, Flexitallic Flexicarb) with 300 Series SS Asbestos or Grafoil Grade GTTMB (eg, Flexitallic Flexicarb) with 300 Series SS Flexitallic with 300 Series SS

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-10 Revision 23 Page 2 of 2 ECCS COMPONENT SYSTEMS SHUTDOWN HEAT EXCHANGERS Component Material Head Gasket 304 SS Jacket Asbestos Tubes ASME SA 249, Grade TP-304 Tube Sheet Cladding 304 SS Channel Cover 304 SS Channel Partition ASME SA 240, Type 304 SS

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-11 Revision 29 Page 1 of 1 Deleted

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-12 Revision 25 Page 1 of 3 ISI MAJOR COMPONENTS AND/OR SYSTEMS LIST ASME CLASS 1 Components Reactor Pressure Vessel, N-50 Reactor Pressure Vessel Closure Head, N-50 Steam Generators - Primary Side, E-50A and E-50B Pressurizer, T-72 Regenerative Heat Exchangers, E-56A and E-56B Piping Primary Coolant System Engineering Safeguards System Chemical and Volume Control System Pumps Primary Coolant Pumps, P-50A, B, C, D Valves ASME CLASS 2 Components Safety Injection and Refueling Water Tank, T-58 Safety Injection Tanks, T-82A, B, C, D Steam Generators - Secondary Side, E-50A, B Regenerative Heat Exchangers, E-56A, B Shutdown Cooling Heat Exchangers, E-60A, B

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-12 Revision 25 Page 2 of 3 ISI MAJOR COMPONENTS AND/OR SYSTEMS LIST Piping Main Steam System Feedwater System Engineered Safeguards System Chemical and Volume Control System Component Cooling System Pumps Containment Spray Pumps, P-54A, B, C High-Pressure Safety Injection Pumps, P-66A, B Low-Pressure Safety Injection Pumps, P-67A, B SIRW Recirculation Pump, P-74 ASME CLASS 3 Components Letdown Heat Exchanger, E-58 Condensate Storage Tank, T-2 Component Cooling Surge Tank, T-3 Spent Fuel Pool Heat Exchangers, E-53A, B Component Cooling Heat Exchangers, E-54A, B Shutdown Cooling Heat Exchangers, E-60A, B Engineered Safeguards Room Coolers, VHX-27A, B Control Room Air Conditioning Units, VC-10, VC-11 Containment Air Coolers, VHX-1, 2, 3, 4 Condensate Storage Tank Heat Exchanger, E-27

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-12 Revision 25 Page 3 of 3 ISI MAJOR COMPONENTS AND/OR SYSTEMS LIST Piping Main Steam System Feedwater System Chemical and Volume Control System Service Water System Component Cooling System Spent Fuel Pool System Condensate System Diesel Jacket Water Cooling System Pumps Service Water Pumps, P-7A, B, C Auxiliary Feedwater Pumps, P-8A, B, C Fuel Pool Cooling Pumps, P-51A, B Component Cooling Pumps, P-52A, B, C Diesel Generator Cooling Pumps P-211A, B

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-13 Revision 33 Page 1 of 1 INSERVICE PUMP TEST PROGRAM

SUMMARY

PUMP ASME SAFETY CLASS P&ID TEST PROCEDURES P-7A, B, and C - Service Water 3

M-213 QO-14/RO-144 P-8A - AFW (Constant Speed) 3 M-207 QO-21/RO-145 P-8B - AFW (Variable Speed) 3 M-205 QO-21/RO-145 P-8C - AFW (Constant Speed) 3 M-205 QO-21/RO-145 P-52A, B, and C - Component Cooling 3

M-209 QO-15/RO-146 P-54A, B, and C - Containment Spray 2

M-204 QO-16/RO-98 P-67A and B - LPSI & Shutdown Cooling 2

M-204 QO-20/RO-98 P-66A and B - HPSI 2

M-204 QO-19/RO-147 NOTE:

See Site Engineering Program SEP-PLP-IST-102, "Inservice Testing of Selected Safety-Related Pumps," for more detail on the pump test program.

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-14 Revision 33 Page 1 of 3 TECHNICAL SPECIFICATION 3.6.3, CONTAINMENT ISOLATION VALVES, APPLICABILITY SEP-APJ-PLP-101, Mechanical Containment Penetrations Basis Program Section, identifies bases for all penetrations. See FSAR Figure 6-5 (P&ID M-232), Containment Penetrations, for piping diagrams.

Penetration Number Equipment ID MZ-1A CV-1805 CV-1806 MV-VA506 MZ-IB MV-VA100 MV-VA101 MV-VA507 MZ-1C CV-1807 CV-1808 MV-VA508 MZ-10 MV-CA122 MV-CA142 MV-CA728 MZ-11 CV-0939 CK-CD401 MV-CD536 MZ-14 CK-CC910 CV-0910 MV-CC507 MZ-15 CV-0911 CV-0940 MV-CC508 MZ-17 MV-VA1802B MV-VA1802C MV-VA1804B MV-VA1804C MV-VA1812A MV-VA1812C MV-VA1814A MV-VA1814B MZ-17A MV-VA1814F MV-VA1814G Penetration Number Equipment ID MZ-18 MZ-18 MZ-18A MZ-21 SV-2415A SV-2415B MV-WG531B MZ-21A SV-2413A SV-2413B MV-WG531A MZ-25 CV-1064 CV-1065 MV-CRW512 MZ-26 CV-1358 CK-N2/400 MV-N2/581 MZ-27 MO-P1 MV-VA604 MZ-27-1 MZ-33 MV-ES3234 MV-ES3234A MV-ES3348A MZ-36 CV-2009 MZ-37 CV-1001 CK-CRW403 MV-CRW503 MZ-40 CV-1910 CV-1911 MV-PC1170A

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-14 Revision 33 Page 2 of 3 TECHNICAL SPECIFICATION 3.6.3, CONTAINMENT ISOLATION VALVES, APPLICABILITY SEP-APJ-PLP-101, Mechanical Containment Penetrations Basis Program Section, identifies bases for all penetrations. See FSAR Figure 6-5 (P&ID M-232), Containment Penetrations, for piping diagrams.

Penetration Number Equipment ID MZ-40A SV-2414A SV-2414B MV-WG530B MZ-40B SV-2412A SV-2412B MV-WG530A MZ-41 CV-1004 CK-CRW407 MV-CRW506 MZ-42 CV-0155 CK-PC155B MV-PC1126 MZ-44 CV-2083 CV-2099 MV-CVC2083 MZ-46 CV-1101 CV-1102 MV-WG511 MZ-47 CV-1002 CV-1007 MV-CRW502 MZ-48 MV-VA1801B MV-VA1801C MV-VA1803B MV-VA1803C MV-VA1805A MV-VA1805C MV-VA1815A MV-VA1815B Penetration Number Equipment ID MZ-49 CV-1036 CV-1038 MV-CRW513 MZ-52 CV-1103 CV-1104 MV-DRW500 MZ-52A MV-DRW618C MV-DRW618D MV-DRW618E MV-DRW618F MV-DRW618G MV-DRW618H MZ-52B MV-DRW619C MV-DRW619D MV-DRW619E MV-DRW619F MV-DRW619G MV-DRW619H MZ-56 MV-VA606B MV-VA606C MZ-64 MV-SFP120 MV-SFP121 MV-SFP514 MZ-65 CK-CA400 MV-CA612 MZ-66 MV-VA-L-6 MV-VA601 MV-VA602 MV-VA603

FSAR CHAPTER 6 - ENGINEERED SAFEGUARDS SYSTEMS TABLE 6-14 Revision 33 Page 3 of 3 TECHNICAL SPECIFICATION 3.6.3, CONTAINMENT ISOLATION VALVES, APPLICABILITY SEP-APJ-PLP-101, Mechanical Containment Penetrations Basis Program Section, identifies bases for all penetrations. See FSAR Figure 6-5 (P&ID M-232), Containment Penetrations, for piping diagrams.

Penetration Number Equipment ID MZ-67 CV-1037 CK-CRW408 MV-CRW515 MZ-68 CV-1813 CV-1814 MV-VA505 MZ-69 CV-1044 CV-1045 MV-CRW518 MZ-72 MV-SFP117 MV-SFP118 MV-SFP515