4 to Updated Final Safety Analysis Report, Chapter 5, Design of Structures, Systems, and Components, Figures
ML19154A281
Person / Time
Site: Palisades 
Issue date: 05/23/2019
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
Shared Package
ML19154A338 List: ... further results
References
PNP 2019-015
Download: ML19154A281 (66)


Text

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-1 Revision 21 OBE HORIZONTAL DESIGN GROUND RESPONSE SPECTRUM (HOUSNER)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-2 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 4% DAMPING

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-3 Revision 21 TAFT GROUND RESPONSE SPECTRUM VERSUS HOUSNER GROUND RESPONSE SPECTRUM (SSE) 72% DAMPING

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-4 Revision 21 CONTAINMENT BUILDING DYNAMIC MODEL

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-5 Revision 21 CONTAINMENT SHELL MAXIMUM SEISMIC RESPONSES (OBE)

COMPARISON OF RESPONSES FOR FIXED BASE AND COUPLED MODELS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-6 Revision 21 AUXILIARY BUILDING N-S MATHEMATICAL MODEL

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-7 Revision 21 AUXILIARY BUILDING E-W MATHEMATICAL MODEL

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-8 Revision 21 ELECTRICAL PENETRATION ENCLOSURE N-S & E-W DYNAMIC MODELS AND MAXIMUM SEISMIC RESPONSES (OBE)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-9 Revision 21 TURBINE BUILDING E-W DYNAMIC MODELS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-10 Revision 21 TURBINE BUILDING E-W FUNDAMENTAL MODESHAPES, OUTSIDE WALLS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-11 Revision 21 TURBINE BUILDING E-W DIRECTION, MAXIMUM SEISMIC RESPONSES (SSE)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-12 Revision 21 AUXILIARY BUILDING RADWASTE ADDITION DYNAMIC MODELS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-13 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION DYNAMIC MODEL

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.7-14 Revision 21 AUXILIARY BUILDING TSC/EER ADDITION MAXIMUM SEISMIC RESPONSES (OBE)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 1 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-1, SHT 2 Revision 21 CONTAINMENT STRUCTURE TYPICAL CROSS SECTION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-2 Revision 21 CONTAINMENT STRUCTURE TYPICAL PIPING PENETRATIONS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-3 Revision 21 CONTAINMENT STRUCTURE TYPICAL ELECTRICAL PENETRATIONS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-4 Revision 21 CONTAINMENT STRUCTURE REINFORCING AND TENDON PLAN ADJACENT TO EQUIPMENT HATCH

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 1 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, SHOP BUTTONHEADED END

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 2 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, HORIZONTAL AND DOME TENDONS, FIELD BUTTONHEADED END

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 3 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, SHOP BUTTONHEADED END

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-5, SHT 4 Revision 21 CONTAINMENT STRUCTURE TENDON HARDWARE ASSEMBLY, VERTICAL TENDONS, FIELD BUTTONHEADED END

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-6 Revision 21 CONTAINMENT STRUCTURE PERSONNEL AIR LOCK

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-7 Revision 21 CONTAINMENT STRUCTURE ESCAPE AIR LOCK

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-8 Revision 21 CONTAINMENT STRUCTURE EQUIPMENT HATCH DOOR

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-9 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-10 Revision 21 CONTAINMENT STRUCTURE DBA THERMAL GRADIENTS ACROSS CONTAINMENT WALL, NO INSULATION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Fi

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.15P

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 3 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + 1.5P + Ta

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-11, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, DOME AND WALL D + Ff + Ta

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 1 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Fi

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 2 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.15P

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 3 Revision 22 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + 1.5 P + Ta

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-12, SHT 4 Revision 21 CONTAINMENT STRUCTURE ISOSTRESS PLOT, WALL AND BASE SLAB D + Ff + Ta

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DEAD LOAD (D)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, FINAL PRESTRESS (Ff)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 3 Revision 21 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA PRESSURE (P)

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-13, SHT 4 Revision 22 CONTAINMENT STRUCTURE STRESS RESULTANTS, DBA TEMPERATURE (Ta)*

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-14 Revision 21 CONTAINMENT STRUCTURE FINITE ELEMENT MESH FOR BUTTRESS, PLANE STRAIN ANALYSIS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 1 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MAXIMUM COMPRESSIVE STRESSES

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-15, SHT 2 Revision 21 CONTAINMENT STRUCTURE BUTTRESS ISOSTRESS PLOT, MINIMUM COMPRESSIVE OR MAXIMUM TENSILE STRESSES

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 1 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-16, SHT 2 Revision 21 CONTAINMENT STRUCTURE MODEL FOR LINER PLATE ANALYSIS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-17 Revision 21 CONTAINMENT STRUCTURE RESULTS FROM TESTS ON LINER PLATE ANCHORS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-18 Revision 21 CONTAINMENT STRUCTURE THERMAL GRADIENT AT MAIN STEAM PENETRATION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-19 Revision 21 CONTAINMENT STRUCTURE LOADS ON PIPE PENETRATIONS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-20 Revision 21 CONTAINMENT STRUCTURE STRESS CONCENTRATIONS AT EQUIPMENT HATCH OPENING

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-21 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, WELD CRACKING AT BACKING STRIP DISCONTINUITIES

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 113°

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-22, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE TEST SAMPLE, ELEVATION 600'-0", AZIMUTH 275°

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 1 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 583'-6"

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 2 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 588'-6"

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-23, SHT 3 Revision 21 CONTAINMENT STRUCTURE LINER PLATE, INSPECTION AND METHOD OF REPAIR, ELEVATION 590'-0"

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-24 Revision 21 CONTAINMENT STRUCTURE LOCATION AND IDENTIFICATION OF ELEVEN SURVEILLANCE TENDONS FOR ONE-AND THREE-YEAR SURVEILLANCES

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 1 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST INSIDE HOOP STRAIN PROFILES TYPICAL SECTION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-25, SHT 2 Revision 21 CONTAINMENT STRUCTURE STRUCTURAL INTEGRITY TEST OUTSIDE MERIDIONAL STRAIN PROFILES TYPICAL SECTION

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-26 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST DISPLACEMENT PROFILES

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 1 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-27, SHT 2 Revision 21 CONTAINMENT STRUCTURE PRESSURE TEST TENDON LOAD CHANGE

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-28 Revision 21 CONTAINMENT STRUCTURE END ANCHORAGE SURVEILLANCE PROGRAM CRACK SURVEILLANCE LOCATIONS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-29 Revision 21 CONSTRUCTION OPENING PLAN, ELEVATION AND SECTIONS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-30 Revision 21 CONSTRUCTION OPENING TENDON DETENSIONING AND POST TENSIONING SEQUENCE

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.8-31 Revision 32 MISCELLANEOUS GAS SUPPLY SYSTEMS

FSAR CHAPTER 5 - DESIGN OF STRUCTURES, SYSTEMS AND COMPONENTS FIGURE 5.9-1 Revision 21 CONTAINMENT STRUCTURE INTERIOR CONSTRUCTION