ML19114A332

From kanterella
Jump to navigation Jump to search
Tn International Safety Analysis Report, DOS-18-011415-000-NPV-2.0, Chapter 00, TN-MTR Packaging, Table of Contents
ML19114A332
Person / Time
Site: 07103052
Issue date: 03/05/2019
From: Willems T
TN Americas LLC, Orano USA
To:
Division of Spent Fuel Management
Shared Package
ML19115A128 List:
References
Download: ML19114A332 (4)


Text

Formulaire : PM04-4-MO-6E rév. 02 Orano TN SAFETY ANALYSIS REPORT NON PROPRIETARY VERSION CHAPTER 00 TN MTR Prepared by T.WILLEMS Date Signature Identification :

DOS-18-011415-000-NPV Vers. 2.0 Page 1 / 4 NON PROPRIETARY VERSION TN-MTR PACKAGING TABLE OF CONTENTS

Form: PM04-4-MO-6 rev.02 NON PROPRIETARY VERSION Orano TN Identification:

DOS-18-011415-000-NPV Version:

2.0 Page 2 of 4 NON PROPRIETARY VERSION Chapter Documents Reference Rev 00 Introduction DOS-18-011415-001 2.0 Appendix 00-2 Table of correspondence between articles of the regulations and sections in the safety analysis report DOS-18-011415-002 1.0 0

Description of the TN-MTR packaging DOS-18-011415-003 1.0 Appendix 0-1 Safety drawings for the TN-MTR packaging DOS-18-011415-004 1.0 0A Description of internal fittings and the load of the TN-MTR packaging DOS-18-011415-005 2.0 Appendix 0A-14 Description of the gisete content and its specific internal fittings DOS-18-011415-041 1.0 Appendix 0A-14-1 Gisete internal fittings safety requirements drawing DOS-18-011415-042 1.0 1

Mechanical analysis of the TN-MTR packaging DOS-18-011415-006 1.0 Appendix 1-1 Resistance of the TN-MTR package to regulatory pressures.

DOS-18-011415-007 1.0 Appendix 1-2 Mechanical strength of ancillary structures DOS-18-011415-008 1.0 Appendix 1-3 Mechanical strength of tie-down and handling devices DOS-18-011415-009 1.0 Appendix 1-4 Conceptual drawings of the qualification mock-up DOS-18-011415-010 1.0 Appendix 1-5 Similarities between the TN-MTR package and the 1/2 scale mock-up DOS-18-011415-011 1.0 Appendix 1-6 Report on regulatory drop tests DOS-18-011415-012 1.0 Appendix 1-7 Analysis of drop tests DOS-18-011415-013 1.0 Appendix 1-8 Structural strength design of the "SEC" lid DOS-18-011415-014 1.0 Appendix 1-9 Analysis of the behaviour of the dropped package model between -40°C and the maximum temperature under normal transport conditions DOS-18-011415-015 1.0 Appendix 1-9-1 Fitting of the oblique drop of the mockup of the TN-MTR package DOS-18-011415-016 1.0

Form: PM04-4-MO-6 rev.02 NON PROPRIETARY VERSION Orano TN Identification:

DOS-18-011415-000-NPV Version:

2.0 Page 3 of 4 NON PROPRIETARY VERSION Chapter Documents Reference Rev Appendix 1-9-2 Behaviour of the TN-MTR packaging model during an oblique top-down drop Temperature extrapolation DOS-18-011415-017 1.0 Appendix 1-9-3 Behaviour of the TN-MTR package during an axial top-down drop Temperature extrapolation DOS-18-011415-018 1.0 Appendix 1-9-4 Fitting of the lateral drop of the mockup of the TN-MTR package DOS-18-011415-019 1.0 Appendix 1-9-5 Behaviour of the TN-MTR package model during a lateral drop Temperature extrapolation DOS-18-011415-020 1.0 Appendix 1-10 Justification of the mechanical strength of package model screwed assemblies under routine transport conditions DOS-18-011415-021 1.0 1A Structural strength of internal fittings of the TN-MTR packaging and their contents DOS-18-011415-022 2.0 Appendix 1A-14 Structural strength of the gisete internal fittings DOS-18-011415-043 1.0 2

Thermal analysis of the package DOS-18-011415-024 1.0 Appendix 2-1 Thermal analysis under normal conditions of transport DOS-18-011415-025 1.0 Appendix 2-1-1 Results of the thermal test report under transport conditions DOS-18-011415-026 1.0 Appendix 2-2 Thermal analysis under accident conditions of transport DOS-18-011415-027 1.0 2A Thermal analysis of internal fittings of the TN-MTR packaging DOS-18-011415-028 2.0 3A Release of activity DOS-18-011415-029 2.0 Appendix 3A-15 Containment of the content of the package consisting of the TN-MTR cask loaded with gisete content DOS-18-011415-044 1.0 4A Calculation of equivalent dose rates around the TN-MTR packaging DOS-18-011415-031 2.0 Appendix 4A-14 Evaluation of equivalent dose rates around the TN-MTR cask loaded with the gisete content and its internal fittings DOS-18-011415-045 1.0

Form: PM04-4-MO-6 rev.02 NON PROPRIETARY VERSION Orano TN Identification:

DOS-18-011415-000-NPV Version:

2.0 Page 4 of 4 NON PROPRIETARY VERSION Chapter Documents Reference Rev 6A Instructions for the use of the TN-MTR packaging DOS-18-011415-035 2.0 7A Test program: acceptance and maintenance DOS-18-011415-036 1.0 Appendix 7A-1 Classification plan for components of the TN-MTR package model DOS-18-011415-037 2.0 8A Quality assurance applicable to package model TN-MTR DOS-18-011415-038 1.0