Formulaire : PM04-4-MO-6E rév. 02 Orano TN SAFETY ANALYSIS REPORT NON PROPRIETARY VERSION CHAPTER 7A - APPENDIX 1 TN MTR Prepared by T.WILLEMS Date Signature Identification :
DOS-18-011415-037-NPV Vers. 2.0 Page 1 / 24 NON PROPRIETARY VERSION CLASSIFICATION PLAN FOR COMPONENTS OF THE TN-MTR PACKAGE MODEL TABLE OF CONTENTS REVISION STATUS
- 1.
PURPOSE
- 2.
PRINCIPLE LIST OF TABLES
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 2 of 24 NON PROPRIETARY VERSION REVISION STATUS Revision Date Modifications Preparation /
Verification Old reference: DOS-16-00173678-701 5
N/A Document first issue. Revision number intentionally set to correspond to the source document revision number.
TWI / ALC New reference: DOS-18-011415-037 1.0 N/A New reference due to new document management system software.
TWI / APA 2.0 N/A Adding of classification plans for the Caesium trap internal fittings and the Gisete internal fittings TWI / SAZ
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 3 of 24 NON PROPRIETARY VERSION
- 1. PURPOSE The purpose of this appendix is to present the classification of the components used in the TN-MTR package (packaging and the various authorised baskets) to determine the type and scope of the tests carried out or to be carried out during the manufacturing of the various elements making up this package model.
- 2. PRINCIPLE The TN-MTR package is used for routine and Normal Conditions of Transport (NCT) including minor incidents; it must therefore respect certain criteria related to the functions described below.
It must also remain 'safe' under Accident Conditions of Transport (ACT); additional acceptance criteria must also be respected (adapted to the accidental nature of the situations).
Direct safety functions:
A: containment B: dose rate (external radiation levels)
C: thermal behaviour D: criticality Indirect safety functions:
E: protection against drops F: protection against fire Other functions:
G: Protection against contamination N.C. : not classified For each of the above-defined functions, the component parts used in manufacturing of the package are classified in categories based upon the effect of a failure of these parts:
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 4 of 24 NON PROPRIETARY VERSION Category Effect of failure 1
Failure to respect a criterion applicable to ACT (Accident Conditions of Transport) when the packaging is subject to NCT (Normal Conditions of Transport) 2 Failure to respect a criterion applicable to ACT when the packaging is subject to ACT 3
Failure to respect a criterion applicable to NCT when the packaging is subject to NCT, however the criterion applicable to ACT is respected 4
Change from NCT to ACT 5
No impact on safety "Failure" is defined as the total loss of the safety function(s) assured by this part under routine, Normal or Accident Conditions of Transport.
Component parts of the package are not all the same in terms of ease of testing, repair or replacement during periodic maintenance imposed in the Safety file, therefore there is an additional maintainability classification index:
Maintainability index Criterion 1
Part, component or sub-assembly that is very difficult or even impossible to test during maintenance and impossible to change or repair without fully reconstructing the packaging or the basket.
2 Part, component or sub-assembly that is difficult to test during maintenance, but that can be replaced or repaired 3
Part, component or sub-assembly that is easy to test during maintenance but impossible to change or repair without fully reconstructing the packaging or the basket.
4 Part, component or sub-assembly that can easily be tested during maintenance and that can be replaced or repaired during maintenance.
5 Part, component or sub assembly that is easy to test and that can be changed or repaired when the packaging is in use before shipment.
For each component in Chapters 0 and 0A, Tables 7A-1.1 to 7A-1.13 show applicable direct or indirect safety function(s), the category related to the effect of a failure of the part and the maintainability index, according to the above classification.
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 5 of 24 NON PROPRIETARY VERSION 4 types of test, with their associated documents, defining severity can be provided, depending on the type of characteristics to be checked; the following table shows a summary of the characteristics to be respected, the tests and the associated documents for each type of recommended test.
Safety functions
'B' Dose rate
'D' Criticality
'C' Thermal behaviour
'F' Fire
'A' Confinement
'D' Criticality
'E' Drop
'A' Confinement
'B' Dose rate
'D' Criticality
'A' Confinement
'B' Dose rate
'C' Thermal behaviour
'D' Criticality
'E' Drop
'F' Fire
'A' Confinement
'C' Thermal behaviour
'G' Contamination Type of test Chemical Composition Physical Characteristi cs (2)
Mechanical properties Homogeneity Dimensions Surface condition 1
Product analysis or test Heat test**
Tests on part, component or sub-assembly 100%
volumetric inspection (X-ray or UT)
(3)
Test 100% prior to assembly Total final test 2
Heat analysis (1) or test by independent organisation (4)
Certificate of conformity Heat test by an independent organisation (4)
Partial volumetric inspection (3)
+ total surface test Test 100% in the factory; partial during installation Final test, by sampling 3
Heat analysis by the factory Heat test by the factory Partial surface test By sampling, in factory Sampling test in the factory 4
Certificate of conformity Certificate of conformity Visual Aspect Supplier certificate of conformity Supplier certificate of conformity
- Not done Physical characteristics are verified based on a certificate of conformity.
(1) For the "criticality" function, the chemical analysis may be replaced by a neutronic test and for the "dose rate" function, by accurate weighing of basic components and performing additional tests to be defined (density, physical characteristics, etc.).
(2) Physical Characteristics: conductivity, melting temperature, coefficient of expansion, etc. The heat tests are only carried out on materials with special specifications (not covered by standards or standard specifications, for which a Certificate of Conformity will be sufficient).
(3) For specific cases, when the performance and interpretation of this test cause problems (neutron-absorbing resin, baskets, seals, etc.) a process qualification, supported by additional manufacturing tests (destructive testing) and statistical analysis or by operational testing may replace the volumetric inspection.
(4) In accordance with EN 10204, the independent organisation may be the authorised representative of the manufacturer that is hierarchically independent of the manufacturing services.
Acceptance criteria are defined in order to upper-bound the requirements laid out in this Safety file.
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 6 of 24 NON PROPRIETARY VERSION Application of these types of inspections and associated documents is defined according to the table below, indicating the type of inspection as a function of the category and the maintainability index; the higher the maintainability index and the category, the higher the test type becomes.
Maintainabilit y
index Category 1
2 3
4 5
1 1
1 1
1 2
2 1
1 2
3 4
3 2
2 3
3 4
4 2
2 3
4 4
5 3
3 4
4 4
Tables 7A-1.1 to 7A-1.13 give the test level corresponding to their category and maintainability index.
Minimum documentation for non-classified parts:
a certificate of conformity a material certificate Parts with no safety function will undergo Type '4' tests.
Note:
The following abbreviations may be used:
N.A.
Not Applicable N.C.
Not Classified
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 7 of 24 NON PROPRIETARY VERSION LIST OF TABLES Table Number Title Number of pages 7A-1.1 Classification of the components of the packaging 5
7A-1.2 Classification of the components of the RHF basket 1
7A-1.3 Classification of the components of the MTR-68 basket 1
7A-1.4 Classification of the components of the MTR-52 basket 1
7A-1.5 Classification of the components of the MTR-52S basket 1
7A-1.6 Classification of the components of the MTR-44 basket 1
7A-1.7 Deleted 7A-1.8 Classification of the components of the MTR-52SV2 basket 1
7A-1.9 Classification of components of the canister for the MTR-52S /
MTR-52SV2 baskets 1
7A-1.10 Classification of components of the CESOX internal fittings 1
7A-1.11 Classification of components of the FRMII basket 1
7A-1.12 Classification of components of the caesium trap internal fittings 2
7A-1.13 Classification of components of the gisete internal fittings 1
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 8 of 24 NON PROPRIETARY VERSION TABLE 7A-1.1 (1/5)
Classification of components of the packaging The references in the table below refer to chapter 0.
Ref.
Designation Function Category Test Maintaina bility index type 1
BODY - SHELL 101 Inner shell A, B, E, G 1
1 1
102 Lead shell B, G 3
1 2
103 Insulation shell F, B 2
1 1
104 Outer shell E, G 2
3 2
105 Flange A, G 1
1 1
121 Regulatory plate N.C.
5 4
4 122 Name plate N.C.
5 4
4 130 Trunnions N.C.
4 4
4 131 Trunnion fastening screws M20 x 45 hex head socket screw N.C.
4 4
4 135 Tie-down lugs N.C.
4 4
4 150 Lid fastening screws M30 x 100 hex head socket screw A, E 1
5 2
151 Shock absorbing cover fastening screws M42 x 100 hex head socket screw E
2 5
4 152 M42 threaded captive washer N.C.
5 5
4 153 M30 threaded captive washer N.C.
5 5
4 170A Shock absorbing cover centring pin N.C.
5 4
4 170B Lid centring pin N.C.
5 4
4 180 Dip tube N.C.
5 4
4 181 Dip tube supports (lower)
N.C.
5 4
4 182 Dip tube supports (upper)
N.C.
5 4
4 190 Fins C
3 4
3 195 1/4 conical gas thermal cut-outs F
2 4
3 196 Poral disk F, G 5
4 4
198 Insert for Poral disk F, G 5
4 4
198B Insert seal for Poral disk F, G 5
4 4
198T Tightening ring for Poral disk F, G 5
4 4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 9 of 24 NON PROPRIETARY VERSION TABLE 7A-1.1 (2/5)
Classification of components of the packaging The references in the table below refer to chapter 0.
Ref.
Designation Function Category Test Maintaina bility index type 2
BODY - BOTTOM 201 Bottom inner disk A, B, E, G 1
1 1
202 Bottom lead disk B, G 3
1 2
203 Bottom insulation disk B, F 2
1 1
204 Bottom outer disk E, G 2
3 2
250 TRUNCATED CONES 251 Insulation truncated cone B, F 2
1 1
252 Steel truncated cone E, G 2
3 2
3 STANDARD LID - Specific parts list 301 Lower disk A, B, E, G 1
3 1
302 Lead outer shell B, E, G 3
3 3
303 Lead central disk B, E, G 3
1 2
305 Lid reinforcing shell B, E, G 1
1 1
306 Lid outer shell A, B, E, G 1
3 1
307 Lid upper disk A, B, E, G 1
4 1
330 Orifice A cover A, G 2
4 3
331 Orifice A tube N.C.
5 3
4 333 Orifice B cover A, G 2
4 3
334 Orifice B tube N.C.
5 3
4 335 Orifice B plug N.C.
5 4
4 4
WOOD IN SHOCK ABSORBING COVER 400 Lower shell, around the trunnions, E,F 2
4 3
radial fibres 401 Bottom shell, between stiffeners, radial fibres E,F 2
4 3
402 Bottom shell, 90° from trunnions, radial fibres E,F 2
4 3
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 10 of 24 NON PROPRIETARY VERSION TABLE 7A-1.1 (3/5)
Classification of components of the packaging The references in the table below refer to chapter 0.
Ref.
Designation Function Category Test Maintaina bility index type 500 Intermediate shell, around E,F 2
4 3
trunnions, radial fibre 501 Intermediate shell, between E,F 2
4 3
stiffeners, radial fibre 502 Intermediate shell, 90°from E,F 2
4 3
trunnions, radial fibre 520 Lower central disk B, E, F 2
4 3
521 Upper central disk B, E, F 2
4 3
600 Inner upper shell, around E, F 2
4 3
trunnions, radial fibre 601 Inner upper shell, between E, F 2
4 3
stiffeners, vertical fibre 602 Inner upper shell, at 90° from E, F 2
4 3
trunnions, radial fibre 603 Outer upper shell, around E, F 2
4 3
trunnions, radial fibre 604 Outer upper shell, between E, F 2
4 3
stiffeners, radial fibre 605 Outer upper shell, at 90° from E, F 2
4 3
trunnions, radial fibre 7
SHOCK ABSORBING COVER PLATES 700 Inner lower shell E, F, G 2
4 3
701 Outer shell E, F, G 2
4 3
702 Upper inner shell E, F, G 2
4 3
703 Portion of shell in trunnion recesses E, F, G 2
4 3
704 Anti-shear ring E, F, G 2
4 3
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 11 of 24 NON PROPRIETARY VERSION TABLE 7A-1.1 (4/5)
Classification of components of the packaging The references in the following table refer to chapter 0.
Ref.
Designation Function Category Test Maintaina bility index type 710 Trunnion recess end plates E, F, G 2
4 3
711 Radial stiffeners E
2 1
1 720 Lower ring E, F, G 2
4 3
721 Lower central disk E, F, G 2
4 3
722 Screw support ring E, F, G 2
4 3
723 Intermediate central disk E, F, G 2
4 3
724 Upper central disk E, F, G 2
4 3
725 Ring between oak and balsa E
2 4
3 726 Shock absorbing cover upper ring E, F, G 2
4 3
730 Sleeves for screw to pass through E, G 2
3 2
731 Water drainage tube N.C.
5 4
4 755 Handling point of the N.C.
5 4
4 shock absorbing cover M30 x 1.5 d thread insert 756 Base of the handling point of the N.C.
5 4
4 shock absorbing cover 195 1/4 conical gas thermal cut-outs N.C.
5 4
4 796 Thermal cut-out holder N.C.
5 4
4 797 Cap for sleeves N.C.
5 4
4 8
SEC LID - Specific parts list 801 SEC type upper lid A, B, E, G 1
4 1
802 SEC type plug B, E, G 1
4 1
803 SEC type ring B, E, G 1
4 1
804 Gripping point plug N.C.
5 4
4 830 Orifice A cover for SEC lid A, G 1
4 1
833 Orifice B cover for SEC lid A, G 1
4 1
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 12 of 24 NON PROPRIETARY VERSION TABLE 7A-1.1 (5/5)
Classification of packaging components The references in the following table refer to chapter 0.
Ref.
Designation Function Category Test Maintainab ility index type 835 Orifice B cover for SEC lid N.C.
5 4
4 855 Plug handling points:
N.C.
5 4
4 M24 1.25 d thread insert 860 Lower seal of the SEC type plug A, G 5
4 4
Parts list common to the two types of lid 312 M20 plug N.C.
5 5
4 332 Self-closing quick disconnect on orifice A N.C.
5 5
4 336 Orifice B cover compression ring N.C.
5 5
4 350 Fastening screws for fastening orifice A and B covers on the lid A, G 1
5 2*
355 M24 x 1.25d thread insert lid handling points N.C.
5 4
4 361 Lid inner seal A, G 1
5 2
362 Lid outer seal N.C.
5 5
4 365 Cover inner seal A, G 1
5 2
366 Cover outer seal N.C.
5 5
4 368 M20 plug seal N.C.
5 5
4 369 Orifice B cover seal N.C.
5 5
4 371 Orifice A staubli seal N.C.
5 5
4
- Exempted from volumetric inspection due to small size.
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 13 of 24 NON PROPRIETARY VERSION TABLE 7A-1.2 Classification of components of the RHF basket The references in the following table refer to chapter 0A-1.
Ref.
Designation Function Category Test Maintaina bility index type RHF Basket 10 Basket structure B, C, D, E, G 2
3 2
11 M 20 x 2D thread inserts N.C.
5 4
4 12 M20 x 35 hex head setscrew N.C.
5 4
4 13 Fitted bottom E, G 2
3 2
14 Removable base E, G 2
3 2
15 M 10 x 1D thread inserts E, G 2
4 3
16 Low head M 10 x 13.5 CHC screws E, G 2
4 3
20 Borated central shell B, C, D, E, G 2
3 2
21 M8 x 16 long tip setscrew E, G 2
4 3
22 Centring device E, G 2
4 3
30 Borated peripheral shell B, C, D, E, G 2
3 2
31 Wedging shell C, B, D, E, G 2
3 2
32 M12 x 1.5D thread insert E, G 2
4 3
33 M12 x 20 FHC screw E, G 2
4 3
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 14 of 24 NON PROPRIETARY VERSION TABLE 7A-1.3 Classification of components of the MTR-68 basket The references in the following table refer to chapter 0A-2.
Ref.
Designation Function Category Test Maintaina bility index type MTR-68 basket 2
Upper support disk B, C, D, E, G 2
3 2
3 Uninterrupted section support disks B, C, D, E, G 2
3 2
4 Lower support disk B, C, D, E, G 2
3 2
5 Neutron poison disk B, C, D 2
3 2
6 Key E, G 2
4 3
7 M8 16 screw E, G 2
4 3
8 Assembly rod E, G 2
4 3
9 M14 nut E, G 2
5 4
10 Springwasher support N.C.
5 4
4 11 M16 x 1.5 thread insert N.C.
5 4
4 12 Key attachment tab N.C.
5 3
4 13 M8 25 screw E, G 2
4 3
14 M12 35 CHC screw E, G 2
4 3
15 Springwasher N.C.
5 3
4 16 Washer N.C.
5 3
4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 15 of 24 NON PROPRIETARY VERSION TABLE 7A-1.4 Classification of components of the MTR-52 basket The references in the following table refer to chapter 0A-3.
Ref.
Designation Function Category Test Maintainab ility index type MTR-52 basket 1
Upper support disk B, C, D, E, G 2
3 2
2 Intermediate support disks B, C, D, E, G 2
3 2
3 Lower support disk B, C, D, E, G 2
3 2
4 Neutron poison disks C, B, D 2
3 2
5 10 18 centring pins N.C.
5 3
4 6
10 32 centring pins N.C.
5 3
4 11 M12 thread insert E, G 2
4 3
12 12 assembly rods E, G 2
4 3
13 M12 hexagonal nuts E, G 2
4 3
14 Dishes N.C.
5 3
4 15 28 x 14.2 x 1.5 2.15 washers N.C.
5 3
4 16 M12 x 24 hex head setscrew N.C.
5 3
4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 16 of 24 NON PROPRIETARY VERSION TABLE 7A-1.5 Classification of components of the MTR-52S basket The references in the following table refer to chapter 0A-4.
Ref.
Designation Function Category Test Maintainab ility index type MTR-52S basket 1
Upper support disk B, C, D, E, G 2
3 2
2 Intermediate support disks B, C, D, E, G 2
3 2
3 Lower support disk B, C, D, E, G 2
3 2
4.1 et 4.2 Neutron poison disks C, B, D 2
3 2
5 10 18 centring pins N.C.
5 3
4 6
10 32 centring pins N.C.
5 3
4 11 M12 thread insert E, G 2
4 3
12 12 assembly rods E, G 2
4 3
13 M12 hexagonal nuts E, G 2
4 3
14 Dishes N.C.
5 3
4 15 28 x 14.2 x 1.5 2.15 washers N.C.
5 3
4 16 M16 x 24 hex head setscrew N.C.
5 3
4 17 Sleeves D, E, G 2
4 3
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 17 of 24 NON PROPRIETARY VERSION TABLE 7A-1.6 Classification of components of the MTR-44 basket The references in the following table refer to chapter 0A-5.
Ref.
Designation Function Category Test Maintainab ility index type MTR-44 basket S1 Top disk B, C, D, E, G 2
3 2
S2 to S11 Intermediate disk B, C, D, E, G 2
3 2
S12 Bottom disk B, C, D, E, G 2
3 2
P1 Top disk B, C, D 2
3 2
P2 to P11 Intermediate disks B, C, D 2
3 2
A to H
Plates for partitions C, B, D 2
3 2
1 Type 1 square N.C.
5 3
4 2
Type 2 square N.C.
5 3
4 3
M8x55 CHc screws N.C.
5 3
4 4
Dish N.C.
5 3
4 5
M12 tie rod E, G 3
3 3
6 28x14.2x1.5 spring washers N.C.
5 3
4 7
M12 nuts E, G 3
3 3
8 Centring pin E, G 5
3 3
9 Poison cross B, C, D 2
4 3
10 Structure cross B, C, D, E, G 2
4 3
11 M 6x12 CHC screws B, C, D, E, G 3
4 3
12 M16-M20 tie rod E, G 3
4 3
13 Gripping bell end B, C, D, E, G 2
3 2(*)
14 L16 washer N.C.
5 4
4 15 HM 16 nut E, G 2
4 3
16 M16 CHC screw N.C.
5 4
4
(*) Considering potential risks to the environment and the safety of persons due to a failure of handling devices, an automatic classification in class 2 is made.
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 18 of 24 NON PROPRIETARY VERSION TABLE 7A-1.8 CLASSIFICATION OF COMPONENTS OF THE MTR-52SV2 BASKET The references in the following table refer to chapter 0A-9.
Ref.
Designation Function Category Test Maintainability index type MTR-52SV2 basket 1
Upper support disk B, C, D, E, G 2
3 2
2 Intermediate support disks B, C, D, E, G 2
3 2
3 Lower support disk B, C, D, E, G 2
3 2
P1 to P9 Neutron absorbing flats peripheral support rings C, B, D 2
3 2
A-F Neutron absorbing flats C, B, D 2
3 2
5 10 centring pins N.C.
5 3
4 11 M12 thread insert E, G 2
4 3
12 12 assembly rods E, G 2
4 3
13 M12 hexagonal nuts E, G 2
4 3
14 Dishes N.C.
5 3
4 15 28 x 14.2 x 1.5 2.15 washers N.C.
5 3
4 16 M16 x 24 hex head setscrew N.C.
5 3
4 17 Sleeves D, E, G 2
4 3
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 19 of 24 NON PROPRIETARY VERSION TABLE 7A-1.9 CLASSIFICATION OF COMPONENTS OF THE CANISTER FOR THE MTR-52S / MTR-52SV2 BASKETS The references in the following table refer to chapters 0A-4 and 0A-9.
Ref.
Designation Function Category Test Maintainability index type Canister plug 1
Main part D, E 1
4 1
2 Locking pin D, E 1
4 1
3 Pads D, E 1
4 1
4 Pad return parts NC 4
5 Spring blade to pad tightening screws NC 4
6 Locking pin low stop NC 4
7 M4 FHC screws NC 4
8 300 micron metal filters D
2 5
4 9
Filter tightening nut D, E 1
4 1
10 Filter protection plate D, E 1
4 1
J1 FKM seal D
1 5
2 Canister body 11 Body D, E 1
4 1
Canister base 12 Main part D, E 1
4 1
13 300 micron metal filter D
2 5
4 14 Wedging plate D, E 1
5 2
15 M4 screw (attachment of the wedging plate onto the main part)
D, E 1
5 2
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 20 of 24 NON PROPRIETARY VERSION TABLE 7A-1.10 CLASSIFICATION OF COMPONENTS OF THE CESOX INTERNAL FITTINGS The references in the following table refer to chapter 0A-11.
Ref.
Designation Function Category Test Maintainability index type CESOX axial wedging 01 Upper disk B
2 4
3 02 Upper central shell NC 5
4 4
03 Lower disk B
2 4
3 CESOX radial wedging 04 Right central half-shell NC 5
4 4
05 Left central half-shell NC 5
4 4
06 Upper ring NC 5
4 4
07 Intermediate ring NC 5
4 4
08 Right half-shell NC 5
4 4
09 Left half-shell NC 5
4 4
10 Lateral guide NC 5
4 4
Fasteners 200 M10x40 CHc screws NC 5
4 4
201 M10 washer NC 5
4 4
202 Ø12 x 40 cylindrical pin NC 5
4 4
203 M12 thread insert NC 5
4 4
204 M10 thread insert NC 5
4 4
205 Boss NC 5
4 4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 21 of 24 NON PROPRIETARY VERSION TABLE 7A-1.11 CLASSIFICATION OF COMPONENTS OF THE FRMII BASKET The references in the following table refer to chapter 0A-12.
Ref.
Designation Function Category Test Maintainability index type U01 Bottom plate C, E 2
4 3
U02 Intermediate plate C, E 2
4 3
U03 Top plate C, E 2
4 3
U04 Tie rod N. C.
5 4
4 U05 Dish N. C.
5 4
4 U06 Borated outer shell B, C, D, E 1
4 1*
U07 Stop N.C 5
4 4
U08 Spacer E
3 3
3 U09 Borated inner shell D
1 4
1*
U10 M12 nut N.C 5
4 4
F01 Springwasher N.C.
5 4
4 F02 M16 washer N.C 5
4 4
F03 M6 screw N.C 5
4 4
F04 Ø4 pin N.C 5
4 4
- Type 1 test for function D only (type 2 test for other functions)
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 22 of 24 NON PROPRIETARY VERSION TABLE 7A-1.12 (1/2)
CLASSIFICATION OF COMPONENTS OF THE CAESIUM TRAP INTERNAL FITTINGS The references in the following table refer to chapter 0A-13.
Ref.
Designation Function Category Maintainability index Type 100 Body receptacle 101 Basic disk E
3 4
3 102 Spacer N.C.
5 4
4 103 Upper disk E
3 4
3 104 Fine shell N.C.
5 4
4 105 Handling tie rods N.C.
5 4
4 106 Bottom nut N.C.
5 4
4 107 Pin N.C.
5 4
4 108 Ring support N.C.
5 4
4 109 Pin for foot wedge E
3 4
3 110 Sheet metal guides for dip tube N.C.
5 4
4 R2 Washer N.C.
5 4
4 E2 Nut N.C.
5 4
4 A2 Dirigible handling ring N.C.
5 4
4 200 Lid 201 Closure disk N.C.
5 4
4 202 Shell E
2 4
3 203 Distribution plate N.C.
5 4
4 204 Reinforcement E
2 4
3 V23 Screws N.C.
5 4
4 J1 O-ring N.C.
5 4
4 V1 Screws N.C.
5 4
4 R1 Washer N.C.
5 4
4 RR1 Self-closing quick N.C.
5 4
4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 23 of 24 NON PROPRIETARY VERSION TABLE 7A-1.12 (2/2)
CLASSIFICATION OF COMPONENTS OF THE CAESIUM TRAP INTERNAL FITTINGS The references in the following table refer to chapter 0A-13.
Ref.
Designation Function Category Maintainability index Type 300 Flange E
3 4
3 400 Foot wedge E
3 4
3 V4 Screws N.C.
5 4
4 500 Set of head spacers N.C 5
4 4
Formulaire : PM04-4-MO-6E rev. 02 NON PROPRIETARY VERSION Orano TN Identification :
DOS-18-011415-037-NPV Vers.
2.0 Page 24 of 24 NON PROPRIETARY VERSION TABLE 7A-1.13 CLASSIFICATION OF COMPONENTS OF THE GISETE INTERNAL FITTINGS The references in the following table refer to chapter 0A-14.
Ref.
Designation Function Category Maintainability index Type Axial wedge 01 Top disk N.C 5
4 4
02 Shell (internal fittings of gisete 4 and 5) or gusset plate (internal fittings of gisete 8)
E 2
4 3
03 Lower disk N.C 5
4 4
200 Screw N.C 5
4 4
201 Washer N.C 5
4 4
202 Pin N.C 5
4 4
203 Thread inserts N.C 5
4 4
204 Thread inserts N.C 5
4 4
Radial wedge (common for the 3 internal fittings) 05 Outer shell N.C 5
4 4
06 Ring E
3 4
3 07 Inner shell N.C 5
4 4
08 Lateral guide N.C 5
4 4
Radial wedge (valid only for the internal fittings of gisete 5 and gisete 8) 09 Bottom disk N.C 5
4 4
10 Lifting system N.C 5
4 4