NPDES Permit No. SC0030856 Renewal Application, Cooling Water Intake Structure Data
ML19056A411
Person / Time
Site: Summer 
Issue date: 01/31/2019
From:
GeoSyntec Consultants, South Carolina Electric & Gas Co
To:
Office of Nuclear Reactor Regulation, State of SC, Dept of Environmental Control, Bureau of Water
Shared Package
ML19056A440 List:
References
RC-19-0012
Download: ML19056A411 (21)


Text

Prepared for SCE&G, VC Summer Station Highway 215 and Bradham Blvd

-Jenkinsville, South Carolina 29065 COOLING WATER INTAKE STRUCTURE *DATA V.C. SUMMER NUCLEAR STATION UNIT 1 4Q CFR § 122.2l(r)(3)

SOUTH CAROLINA ELECTRIC & GAS COMPANY JENKINSVILLE, SOUTH CAROLINA Prepared by Geosyntec t>

consultants engineers I scientists I innovators 1255 Roberts Boulevard, Suite 200 Kennesaw, Georgia 30144 Project Number GK5356 January 2019

Geosyntec t>

consultants TABLE OF CONTENTS

1.

IN"1RODUCTION................................................................................................ 1

2.

FACILITY AND CWIS DESCRIPTIONS.......................................................... 3 2.1 Cooling Water Intake Structure Configuration........................................... 4 2.2 Cooling Water Intake Structure Coordinates............................................... 6 2.3 Cooling Water Intake Structure Operation....................................... :.......... 7 2.3.1 Traveling Screen Operation............................................................ 7 2.3.2 Circulating Water Pumps............................................................... 7 2.3.3 Clarifier Raw Water Pumps........................................................... 8 2.4* Flow Distribution and Water Balapce............................ :............................ 8 2.5. Engineering Drawings****************************************:***************************************** 8

3.

SUMMARY

AND CONCLUSION*..................................................................... **9

4.

REFERENCES CITED................................ :..................................................... 10 Figure 1 Figure 2 Figure 3 Figure 4 Appendix A LIST OF FIGURES Site Vicinity ofVCSNS Unit 1 Site Layout of the VCSNS Unit 1 Cooling Water Intake Structure and the Fairfield Pumped Storage Facility Bathymetric Depiction of Monticello Reservoir ne~r the VCSNS Unit 1 CWIS, April 2005 V.C. Summer Nuclear Station (VCSNS Unit 1) Water Balance Diagram APPENDICES Engineering Drawings GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 01.23.2019

CFR cfs CWA CWIS FERC fpm fps ft FPSF gpm hp

.M.SL MW.

NGVD29 NPDES NRC psi rpm SCDHEC SCE&G

. VCSNS LIST OF ACRONYMS AND ABBREVIATIONS Code of Federal Regulations cubic feet per second Clean Water Act cooling water intake structure Federal Energy Regulatory Commission feet per minute feet per second feet Fairfield Pumped Storage Facility gallons per minute horsepower mean sea level megawatts National Geodetic Vertical Datum of 1929 National Pollutant Discharge Elimination System.

Nuclear Regulatory Commission pounds per square inch revolutions per minute Geosyntec t>

consultants South Carolina Department of Health and Environmental Control South Carolina Electric and Gas Company Virgil C. Summer Nuclear Station GK5356/R3_CWIS VCSNS_Rev20!9_GA160664.docx ii 01.23.2019

Geosyntec 1>

consultants

1.

INTRODUCTION This report provides cooling water intake structure (CWIS) data for South Carolina Electric & G~s Company's (SCE&G's) Virgil C. Summer Nuclear Station (VCSNS)

Uni'Cl. VCSNS Unit 1 is an existing nuclear-powered generating facility located on Monticello Reservoir in the Broad River basin near Jenkinsville, F*airfield County, South Carolina. SCE&G operates VCSNS Unit 1 under National Pollutant Discharge Elimination System (NPDES) Permit Number SC0030856. The information provided in this report supports the facility's compliance with section 3 l 6(b) of the Clean Water Act.

The U.S. Environmental Protection Agency published 3 l 6(b) regulations for cooling water intake structures (CWISs) at existing power generating and manufacturing facilities that became effective October 14, 2014. The final 3l6(b) rule requires the submittal of applicable CWIS information under 40 CFR § 122.2l(r) to the South Carolina

As provided in the NPDES permit application requirements at 40 CFR § 122.2l(r)(3), all existing facilities with CWISs must submit the following CWIS data:

(i)

A narrative description of the configu.ration of each of your cooling water intake structures and where it is located in the water body and in the water column; (ii)

Latitude and longitude in degrees, minutes, and seconds for each of your cooling water intake structures; (iii)

A narrative description of the operation of each of your cooling water intake structures, including design intake flows, daily hours of operation, number of days _of the year in operation and seasonal changes, if

  • applicable; (iv)

A flow distribution and water balance diagram that includes all sources of water to the facility, recirculating flows, and discharges; and (v)

Engineering drawings of the cooling water intake structure.

For the purposes of this report, the CWIS means the total physical structure and any associated constructed waterways used to withdraw cooling water from waters of the U.S.

GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 01.23.2019

Geo syn.tee t>

consultants (40 CPR§ 125.92). The CWIS extends from the point at which water is withdrawn from the surface water source up to, and including, but not limited to, the intake pumps.

VCSNS Unit 1 uses Monticello Reservoir as its source waterbody.

GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 2

01.23.2019

Geosyntec 1>

consultants

2.

FACILITY AND CWIS DESCRIPTIONS VCSNS Unit 1 is a single-unit, 972.7-megawatt (MW), nuclear-fueled, base-load facility located at the southern end of Monticello Reservoir, a freshwater impoundment (Figure 1). Unit 1 operates using a single CWIS located along the shoreline (Figure 2). It has a design intake capacity of approximately 533,122 gallons per minute or 768 million gallons per day (MGD). The actual intake flow of the CWIS is greater than 125 MGD.

Although the cooling water system operates in a "once-through" mode, Monticello Reservoir was constructed for the purpose of serving as part of the cooling water system (U.S. Nuclear Regulatory Commission [NRC], 2004). Thus, the use of Monticello Reservoir as a cooling impoundment for VCSNS Unit 1 has been determined by SCDHEC and EPA to be a closed-cycle recirculating system under 40 CFR, Part 125, Subpart J, §125.92(c)(2).

Monticello Reservoir is a 6,500-acre freshwi;tter lake with 51 miles of shoreline. It is located on a small tributary.of the Broad River. Monticello Reservo~ was built in the Frees Creek valley in 1978 to serve as the upper pool for the Fairfield Pumped Storage Facility (FPSF) and the cooling water source for VCSNS Unit 1 (NRC, 2004 ). The reservoir is hydrologically connected to a 300-acre sub-impoundment that is managed for recreational boating and fishing by SCE&G and the South Carolina Department of Natural Resources. Monticello Reservoir has a total storage capacity of approximately 400,000 acre-feet (Kleinschmidt, 2015) with an average depth of 59 feet (ft) and a maximum depth of 125 ft.

Monticello Reservoir and Parr Reservoir serve as the upper and lower pools, respectively, for FPSF. FPSF is part of the Parr Hydroelectric Project operated by SCE&G, which is licensed by the Federal Energy Regulatory Commission (FERC). FPSF pumps water from Parr Reservoir, a freshwater impoundment of the Broad River, into Monticello Reservoir (Figure 2). Parr Reservoir was enlarged in 1977 from 1,853 to 4,398 acres for added pumped storage exchange with Monticello Reservoir and as makeup water for evaporative losses from Monticello Reservoir due to VCSNS Unit 1 operations (SCE&G, 2002). FPSF generates hydroelectricity by releasing water from Monticello Reservoir into Parr Reservoir using active storage of29,000 acre-feet (Kleinschmidt, 2015). During off-peak power demand periods, FPSF turbines reverse and once again pump water back into Monticello Reservoir for the next generation cycle.

GK5356/R3_CWIS VCSNS_Rev2019_GA!60664.docx 3

01.23.2019

Geosyntec t>

consultants The full-pool elevation of Monticello Reservoir is typically managed to 425 ft mean sea level (MSL, NGVD29). Monticello Reservoir experiences daily fluctuations in surface elevation ofup to a maximum of 4.5 ft due to pumped storage operations (Kleinschmidt, 2015). Under the FERC license for the Parr Hydroelectric Project, SCE&G manages Monticello Reservoir elevations within an operating range of 420.5 to 425.0 ft.

2.1 Cooling Water Intake Structure Configuration The VCSNS Unit 1 CWIS consists of an inlet bay created by two embankments, which both support an electrical transmission tower and concludes at the circulating pump house structure positioned parallel to the southern shoreline of Monticello Reservoir near the FPSF. The cooling water inlet bay is about 550 ft wide east to west at its widest dimension and about 200 ft in length north to south at its longest dimension between the transmission tower embankments (Figure 2). The water depth in the inlet bay ranges from 30 to 40 ft.

Bathymetry of the intake bay measured using acoustic Doppler current profiling techniques (Geosyntec Consultants, Inc., 2005) is presented in Figure 3.

The circulating pump house intake structure is 93 ft wide with six intake bays each approximately 13-ft wid_e. Parallel concrete retainer waUs extend out into the inlet _bay a*.

distance of approximately 30 ft. Trash racks comprised of steel bars with 10-inch spacing.

are located along the upstream face of the pump house structure to prevent large debris from entering the intake bays. The trash racks are mounted to the bottom of a skimmer wall that extends from the water surface to a depth of 9.5 ft ( 415.5 ft MSL) at normal high water (425 ft MSL). The skimmer wall is designed to exclude floating debris from entering the cooling water system and, combined with the pump house retainer walls, to optimize withdrawal of the coolest water from mid depth of the water column at the pump house. Vertical traveling water screens are located 25 ft behind the trash racks to strain out smaller debris. A bar grid structure is located between the traveling screens and the circulating pumps. Three circulating water pumps convey screened flow to the condensers. At normal full pool, the CWIS is designed to withdraw water from the water column between elevations 415.5 ft and 390 ft MSL; or from a depth of 9.5 ft to 35 ft.

After leaving the condensers, the heated cooling water discharges to Monticello Reservoir via a 1,000-foot-long discharge canal located east of the CWIS beyond the service water*

pond and jetty (Figure 2).

GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 4

01.23.2019

Geosyntec 1>

consultants Following is a summary of pertinent CWIS specifications/data for VCSNS Unit 1:

1.

NPDES Permit: SC0030856;

2.

EPA ID#: AUT0345;

3.

Permit Expiration Date: May 31, 2019;

4.

. Estimated design intake flow: 768 MGD or 1,187.8 cubic feet per second (cfs);

5.

Intake velocity is: 1.31 feet per second (fps) through the traveling screens;

6.

Water Level Elevations are:

a. High elevation: 425.0 ft;
  • b. Low elevation: 4205 ft; and
c. Emergency elevation: 418.Q ft.
7..

Water 'depths in the intake bay are 35 ft maximum (normal high *water) and 28 ft minimum ( emergency drawdown elevation);

8.

Intake structure:

a. Location: Southern end of cooling impoundment;
b. Configuration (relative to shore): onshore and parallel to shoreline;
c. Length: 93 ft; and
d. Number of bays: 6.
9.

Traveling water screens:

a. Location: 25 ft downstream from trash racks;
b. Number: 6;
c. Rotation speeds: 2.5 and 10 feet per minute (fpm);
d. Width: 10 ft;
e. Mesh size and geometry: 3/8 in. square mesh openings; GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 5

01.23.2019

Geosyntec 1>

consultants

f.

Spray nozzle configuration: front;

g. Volume: 225 gallons per minute (gpm);
h. Pressure: 60 pounds per square inch (psi);
1.

Fish return: 3-ft wide x 2-ft deep debris/fish trough; J.

Trough configuration: slopes downward to south side structure; and

k. Other: timer_-actuated (all six screens concurrently) every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or by differential pressure switch, screens replaced every 6 years.
10.

Circulating water pumps:

a. Location: 35 ft center to center, downstream of traveling water screens;
b. Number of pumps: 3;
c. Type of pumps: SAFV, vertical solid shaft; and
d. Flow per pump: 395.94 cfs (177,700 gpm).
11.

Screen wash pumps:

a. Location:* Two; discharge side ofcirculating water pump no. 1 C; and
b. Flow per pump: 4.46 cfs (2,000 gpm).
12.

Clarifier raw water pumps:

a. Location: Two; just east of circulating water pump no. lA; and
b. Flow per pump: 4.46 cfs (1,200 gpm).

Plan and section view engineering drawings and specifications for the VCSNS Unit 1 CWIS are provided on SCE&G Drawing E-026-101 included in Appendix A.

2.2 Cooling Water Intake Structure Coordinates The circulating cooling water pump house intake structure is located in Fairfield County, South Carolina, at Latitude: 34° 17' 59.0640" N and Longitude: 81 ° 18' 51.9012" W. It

.is at the southern shore of Monticello Reservoir with a top deck elevation of 438.0 ftMSL and an invert elevation of 390.0 ft MSL.

GK5356/R3 _ CWIS VCSNS_Rev2019 _ GA160664.docx 6

01.23.2019

Geosyntec 1>

consultants 2.3 Cooling Water Intake Structure Operation VCSNS Unit 1 is designed to operate.in one cooling mode, closed-cycle utilizing Monticello Reservoir. Cooling water is drawn in at the pump house, passed through the I

steam condenser as well as the auxiliary condensers, and discharged back to Monticello Reservoir via a discharge canal located east of the CWIS (Figure 2). The U.S. Energy Information Administration (2017) rated VCSNS Unit 1 in 2010 at 971 MW summer capacity, 6,913,294 megawatt-hours net generation, and an 81.3 percent summer capacity factor.

2.3.1 Traveling Screen Operation The VCSNS Unit 1 CWIS traveling water screens are timer-actuated, operating all six screens concurrently, every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or earlier as may be dictated by differential pressure across the screens. Each screen is designed to rotate at either 2.5 or 10 fpm, depending on the extent of debris loading. A 60-psi front wash system cleans the screens.

Screen-wash water is-~upplied to each traveling screen at a volume of 225 gpm (0.5 cfs) fromtw.o 100-percent capacity screen wash pumps. Each pump dr~ws from the discharge side of circulating pump number 1 C located on the west side of tlie pump house. Each screen wash pump is rated at 200 horsepower (hp) at 1,750 revolutions per minute (rpm) and provides approximately 2,000 gpm (4.46 cfs) for screen wash. Screen-wash water collects in a debris trough that conveys the debris and any impinged organisms to a screened collection basket located in a trash sump on the west side of the pump house.

Collected debris and any associated organisms are retrieved from the collection basket and discarded approximately every two weeks depending on debris load. Screen-wash water having passed through the screened collection basket is directed back to the pump house between the traveling screens and circulating water pump number 1 C.

2.3.2 Circulating Water Pumps VCSNS Unit 1 has three, vertical, wet-pit type circulating water pumps located 35 ft downstream of the traveling water screens. The operating design point of each pump is 395.94 cfs at 2,095 hp and 294 rpm. Three pumps are required when at full power, with an average total flow of 1,187.8 cfs. Flow from the individual pumps combine into a single intake pipe before reaching the condensers.

GK5356/R3_CWIS \\ICSNS_Rev2019_GA160664.docx 7

01.23.2019

Geosyntec 1>

consultants At design flows, the velocity through the trash racks is 0.72 fps at emergency drawdown elevation of 418.0 MSL. At the same water level, through-screen velocity at the traveling screens is 1.31 fps (Appendix A, SCE&G Drawing No.: E-026-101).

2.3.3 Clarifier Raw Water Pumps The CWIS has two 100-percent capacity clarifier raw water (non-cooling water) pumps to provide raw water to the plant water treatment system, which in tum provides clean and treated water for a multitude of processes. Each pump is a vertical, wet-pit type pump that draws from the pump house basin.

Each clarifier raw water pump provides approximately 1,200 gpm (2.67 cfs) when operating. Although the water balance shown on SCE&G drawing D-921-931, Rev 2 indicates that this process flow is 0.262 MGD (182 gpm), SCE&G site personnel indicate that one of the two pumps essentially runs

  • continuously, thus daily flow is approximately 1.73 MGD*or 2.67 cfs. A small portion of the treated.water is used as make-up to the on-site cooling tower, which is a closed-loop cooling water system used to cool various turbine building cooling loads, such as the steam turbine lube oil and geiwrator hydrogen coolers.
  • .2.4 Flow Distribution and Water Balance The distribution of cooling water flows at VCSNS Unit 1 and associated water balance diagram are presented in Figure 4.

2.5 Engineering Drawings Appendix A includes Drawing Number MOOO-SKM-003, Rev A which presents a concise plan view of the VCSNS Unit 1 CWIS and associated intake bay. This drawing is based on SCE&G Drawing Number E-036-001, which includes most of the VCSNS Unit 1 facility. Plan and section view engineering drawings and specifications for the VCSNS Unit 1 CWIS are provided on SCE&G Drawing E-026-101 also included in Appendix A.

Additional detailed engineering drawings prepared by SCE&G for the VCSNS Unit 1 cooling water system will be made available upon request.

GK.5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 8

01.23.2019

Geosyntec C>

consultants

3.

SUMMARY

AND CONCLUSION

'VCSNS Unit I is a single-unit, 972.7-MW, nuclear-fueled, base-load power generating facility located at the southern end of Monticello Reservoir in Fairfield County, South Carolina. Monticello Reservoir is a 6,500-acre freshwater impoundment constructed for the purpose of serving as part of the VCSNS cooling water system. The single, shoreline CWIS is part of a cooling water system that has been determined by SCDHEC and EPA to be a closed-cycle recirculating system under the definition at 40 CFR §125.92(c)(2).

The CWIS has a design intake flow of approximately 768 MGD. Monticello Reservoir also serves as the upper pool for the FPSF, which is part of SCE&G's Parr Hydroelectric Project.

The VCSNS Unit I CWIS begins as an inlet bay on the soutl;i shore of Monticello Reservoir with a depth of 30 to 40 ft. The circulating pump house intake structure within the bay is 93 ft wide and has six intake bays. Parallel concrete-retainer walls on either side of the pump house and a skimmer wall extending 9.5 ft below the full pool elevat~on direct the withdrawal of cooling water from the deeper, seasonally cooler mid-depth portion of the reservoir. Six vertical 3/8-inch mesh traveling water screens strain out debris and* any impinged organisms, which are conveyed by the screen-wash system to a trash sump for disposal. Three circulating water pumps convey the screened intake flow to the condensers.

After leaving the condensers, the heated cooling water discharges to Monticello Reservoir via a discharge basin and a 1,000-foot-long discharge canal located east of the CWIS beyond the service water pond and jetty.

A water balance diagram and engineering drawings of the VCSNS Unit I CWIS are provided herein. Additional detailed engineering drawings of the CWIS will be made available by SCE&G upon request.

GK.5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 9

01.23.2019

Geosyntec t>

consultants

4.

REFERENCES CITED Geosyntec Consultants, Inc. 2005. Delineation of the Area of Hydraulic Influence Attributable to the Virgil C. Summer Nuclear Station Cooling Water Intake Structure. South Carolina Electric & Gas Company, Jenkinsville, South Carolina.

Kleinschmidt. 2015. Pre-application Document, Parr Hydroelectric Project, FERC Project No. 1894. Prepared for South Carolina Electric and Gas Company, Cayce, South Carolina. January 2015.

South Carolina Electric and Gas Company (SCE&G). 2002. Virgil C. Summer Nuclear Station License Renewal Application. Appendix E, Environmental Report.

Docket Number 50/395; License NumberNPF-12; Jenkinsville, South Carolina.

U.S. Energy Information Administration. 2.017. State nuclear profiles. U.S. Department of

Energy, Washington, D.C.

April 2012.

https://www.eia.gov/e1ecfricity!state/southcaro1ina/

h~ps://www.eia.gov/nuclear/ generation/

Accessed at:

and

, U.S. Nuclear Regulatory Commission* (NRC). 2004. Generic Environmental Impact Statement for License Renewal of Nuclear Plants. Supplement 15 Regarding Virgil C. Summer Nuclear Station. Final Report. U.S. Nuclear Regulatory Commission, Washington, DC.

GK5356/R3_CWIS VCSNS_Rev2019_GA160664.docx 10 01.23.2019

FIGURES

I r

\\

/

Hope Station

\\.

~

I I

~

I I

/

\\

LEGEND N

10-km (6-mi) radius of V.C. Summer N

Interstates N

Major Roads Minor Roads County Boundaries Lakes and Rivers Site Vicinity of VCSNS Unit 1 Jenkinsville, South Carolina

(

l Parr Hydro 1 Monticello N

Sub-lmpdu~dme-!'t w*,

s

\\

l \\

-r*

\\

I I

'r-

... ~

} \\

,,<.,'J' I

F

/

I I

~

t(\\

' 'i

{

1/1

. Jenklnsvllle

\\

\\

(

--.;;;;,o* ---.1;;...;;.;;;;_,~2 ----3 r: 1es Geosyntec e>

consultants Atlanta, Georgia Source: NRC, 2004.

Figure 1

0 Parr Reservoir Monticello Reservoir EXCLUSION ZONE Wastewater Treatment Area SOURCE: NRC, 2004.

Site Layout of the VCSNS Unit 1 Cooling Water Intake Structure and the Fairfield Pumped Storage Facility Jenkinsville, South Carolina 1500 0

1500 Geosyntec t>

consultants ATLANTA, GEORGIA 3000 feet Figure 2

t N

Monticello Reservoir Intake Structure Location Bathymetric Depiction of Monticello Reservoir near the VCSNS Unit 1 CWIS, April 2005 Geosyntec t>

FIGURE NO.:

3 PROJECT NO.:

GK3601 -04 consultants DOCUMENT NO.:

GA050382 Atlanta, Georgia FILE:

Figure 2-3.ppt 3 Dimensional view Elevation (feet above mean sea level) 1111 350-360 1111 360 - 370 1111 370 - 380 1111 380 - 390 1111 390 - 400 1111 400 - 410 410 - 420 C:=J 420 - 430 SOURCE: GeoSyntec 2005

V C Summer Nuclear S_tatiori. Water Balance Diagram From Monticcllo Reservoir 0

CW Pump Hou~e 0 = 767.67 MGD = Mam and auxiliary condensers.

Mnin&

Amdlinry Condensers To Plant Jntuke


~ Water Treatment To Discharge Bny To Multiple Outfalls (see D-921-931 0 = 2.88 MGD = Screen wash pump flow backwash for the traveling waler screens 0 = 1.73 MGD = Clarifier raw waler process ( non-cooling wat~ £low) l?, U~e O!l*sile waler treatment plant Geosyntec t>

consultants Atlanta, Georgia FIGURE NO.: 4 Prepared by::

PROJECT NO.: GK3601-04 DOCUMENT NO.: GA050382 FILE: Figure 2-4.ppt CH2MHILL Lockwood Greene

APPENDIX_A.

Engineering Drawings.*.:

17 16 15

,, *.*.,~cc 13 SECTION B-B SECTION C-C LID.-1-*IUINL LU.---'11*1'11"' __

a.u:r........

Q......,O.

NOT FOR CONSTRUCTION

I I

I I I

I I

I I

I I

I *--------------

EL. 438.0 I

I I

I


+----.

I I

CIRCULATING. WATER INTAKE STRUCTURE PLAN VIEW

/

I I

I ELl395.0 I

I I

I I

I I

I I

I I

\\

)

DUKE TRAN 15510N TWR EMBANKMENT EL. 436.0


APPROXIMATELY 546.4 FT.--------------+----------;

DUKE TRANSMISSION TWR EMBANKMENT EL. 438.0 NORMAL. WATER LEVEL EL 425.0 CH2MHILL Lockwood Greene Afklnta,Georgio gl

,0

,0

<e'sc~..i*

V.C.SUMMER NUCLEAR STATION JENKINSVILLE, SC 29065 Scoll:

I IHO!

  • JO fUT 0227:2S.01 A

1*-J0*-0*

SKM-003