ML19051A140

From kanterella
Jump to navigation Jump to search
Attachment 4: Affected Pages ofEIP-ZZ-00101 Addendum 2, Emergency Action Level Technical Bases Document, Proposed Revision 016
ML19051A140
Person / Time
Site: Callaway  
(NPF-030)
Issue date: 02/20/2019
From:
Ameren Missouri, Union Electric Co
To:
Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
Shared Package
ML19051A135 List:
References
ULNRC-06488
Download: ML19051A140 (16)


Text

Attachment 4 to ULNRC-06488 Affected Pages ofEIP-ZZ-00101 Addendum 2, "Emergency Action Level Technical Bases Docmnent,"

Proposed Revision O 16 (Clean Copy)

(15 pages)

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Maintain - Take appropriate action to hold the value of an identified parameter within specified limits.

Owner Controlled Area (OCA) - The fenced area contiguous to the Protected Area, designated by AmerenUE (Callaway Plant) to be controlled for security purposes (ref 4.1.6).

Projectile - An object directed toward a Nuclear Power Plant that could cause concern for its continued operability, reliability, or personnel safety.

Protected Area (PA) - An area encompassed by physical baniers and to which access is controlled. The Protected Area refers to the designated secmity area around the process buildings and is depicted in Drawing 8600-X-88100 Prope1ty-Site Layout, Owner Controlled Area and Surrounding Area (ref. 4.1.7).

RCS Intact - The RCS should be considered intact when the RCS pressure boundary is in its n01mal condition for the Cold Shutdown MODE of operation ( e.g., no freeze seals or nozzle dams). The RCS is capable of being placed in an intact condition by Operator Action, i.e.,

pressurized to supp011 natural circulation cooling.

Reduced Inventory - Plant condition when fuel is in the reactor vessel and Reactor Coolant System level is lower than 3 feet below the Reactor Vessel flange ( < 64.0 in.) (ref. 4.1.13 ).

Refueling Pathway - The reactor refueling cavity, spent fuel pool and fuel transfer canal comp1ise the refueling pathway.

Restore - Take the appropriate action required to return the value of an identified parameter to the applicable limits.

Ruptured - The condition of a steam generator in which p1imary-to-secondary leakage is of sufficient magnitude to require a safety injection.

Safety System - A system required for safe plant operation, cooling down the plant and/or placing it in the Cold Shutdown condition, including the ECCS. These are typically systems classified as safety-related (as defined in IOCFRS0.2):

Those structures, systems and components that are relied upon to remain functional during and following design basis events to assure:

1) The integrity of the reactor coolant pressure boundary;
2) The capability to shut down the reactor and maintain it in a safe shutdown condition;
3) The capability to prevent or mitigate the consequences of accidents which could result in potential offsite exposmes.

Security Condition - Any security event as listed in the approved secmity contingency plan that constitutes a tlu*eat/compromise to site secmity, threat/risk to site personnel, or a potential degradation to the level of safety of the plant. A security condition does not involve a hostile action.

Page 21 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Site Area Emergency - Events are in process or have occurred which involve actual or likely major failures of plant functions needed for protection of the public or hostile actions that result in intentional damage or malicious acts; (1) toward site personnel or equipment that could lead to the likely failure of or; (2) that prevent effective access to equipment needed for the protection of the public. Any releases a.re not expected to result in exposure levels which exceed EPA Protective Action Guidelines exposure levels beyond the site boundary.

Site Boundary - Exclusion Area Boundm-y is a synonymous term for Site Boundary. The Exclusion Area is defined as the area that encompasses the land sun-ounding the Plant to a radius of 1,200 meters (3,937 feet) from the midpoint of the Unit 1 Reactor Building and the canceled Unit 2 Reactor Building. Control of access to this is by virtue of ownership and in accordance with IOCFR 100 (ref. 4.1.12).

Unisolable - An open or bi-eacbed system line that cannot be isolated, remotely or locally.

Unplanned - A parameter change or an event that is not 1) the result of an intended evolution or 2) an expected plant response to a transient. The cause of the parameter change or event may be known or unknown.

Unusual Event - Events are in process or have occmred wruch indicate a potential degradation in the level of safety of the plant or indicate a secutity tlu*eat to facility protection has been initiated. No releases of radioactive material requiring offsite response or monitming are expected unless further degradation of safety systems occurs.

Valid - An indication repmi or condition, is considered to be valid when it is verified by (1 an instrument channel check, or (2) indications on related or redundant indicators, or (3) by direct observation by plant personnel, such that doubt related to the indicator s operability, the condition's existence, or the report s accuracy is removed. Implicit in this definition is the need for timely assessment.

Visible Damage - Damage to a SAFETY SYSTEM train that is readily observable without measurements, testing, or analysis. The visual impact of the Jamage is sufficient to cause concern regarding the operability or reliability of the affected SAFETY SYSTEM train.

Page 22 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT 6.0 CALLAWAY-TO-NEI 99-01 REV. 6EAL CROSS-REFERENCE This cross-reference is provided to facilitate association and location of a Callaway EAL within the NEI 99-01 IC/EAL identification scheme. Further information regarding the development of the Callaway EALs based on the NEI guidance can be found in the EAL Comparison Matrix.

Callaway NEI 99-01 Rev. 6 Callaway NEI 99-0 I Rev. 6 Callaway NEJ 99-01 Rev. 6 EAL IC Example EAL EAL JC Example EAL EAL IC Example EAL RU1.1 AU1 1, 2 CU5.1 CU5 1, 2, 3 HA5.1 HAS 1

RU1.2 AU1 3

CA1.1 CA1 1

HA6.1 HA6 1

RU2.1 AU2 1

CA1.2 CA1 2

HA7.1 HA7 1

RA1.1 AA1 1

CA2.1 CA2 1

HS1.1 HS1 1

RA12 AA1 2

CA3.1 CA3 1, 2 HS6.1 HS6 1

RA1.3 AA1 3

CA6.1 CA6 1

HS7.1 HS7 1

RA1.4 AA1 4

CS1.1 CS1 1

HG7.1 HG7 1

RA2.1 AA2 1

CS1.2 CS1 2

SU1.1 SU1 1

RA2.2 AA2 2

CS1.3 CS1 3

SU3.1 SU2 1

RA2.3 AA2 3

CG1.1 CG1 1

SU4.1 SU3 2

RA3.1 AA3 1

CG1.2 CG1 2

SU5.1 SU4 1, 2, 3 RA3.2 AA3 2

FA1.1 FA1 1

SU6.1 SU5 1

RS1.1 AS1 1

FS1.1 FS1 1

SU6.2 SU5 2

RS1.2 AS1 2

FG1.1 FG1 1

SU7.1 SU6 1, 2, 3 RS1.3 AS1 3

HU1.1 HU1 1, 2 3 SU8.1 SU7 1, 2 RS2.1 AS2 1

HU2.1 HU2 1

SA1.1 SA1 1

RG1.1 AG1 1

HU3.1 HU3 1

SA3.1 SA2 1

RG1.2 AG1 2

HU3.2 HU3 2

SA6.1 SA5 1

RG1.3 AG1 3

HU3.3 HU3 3

SA9.1 SA9 1

RG2.1 AG2 1

HU3.4 HU3 4

SS1.1 SS1 1

CU1.1 cu1 1

HU4.1' HU4 1

SS2.1 SS8 1

CU1.2 CU1 2

HU4.2 HU4 2

SS6.1 SS5 1

CU2.1 CU2 1

HU4.3 HU4 3

SG1.1 SG1 1

CU3.1 CU3 1

HU4.4 HU4 4

SG1.2 SGB 1

CU3.2 CU3 2

HU7.1 HU7 1

EU1.1 E-HU1 1

CU4.1 CU4 1

HA1.. 1 HA1 1, 2 Page 25 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT 7.0 ATTACHMENTS 7.1., Emergency Action Level Technical Bases 7.2., Fission Product Bani.er Loss I Potential Loss Matii.x and Bases 8.0

SUMMARY

OF CHANGES Page(s) Section or Step Description Number Changed the definition of Visible Damage to:

21 Definitions "Damage to a SAFETY SYSTEM train that is readily observable without 22 CA6.l Def.

measurements, testing, or analysis. The visual impact of the damage is sufficient to 112 SA9.l Def cause concern regarding the operability or reliability of the affected SAFETY 187 SYSTEM train."

to help clarify the intent of visible damage.

25 6.0 Deleted HG 1.1 from the Callaway to NEI cross reference chart.

69 EUl.l Basis Removed reference to HG 1 from last sentence of basis.

Reworded the EAL to better address the intent. The new wording reads:

'The occurrence of any Table C-6 (S-5) hazardous event AND Event damage has caused indication of degraded performance on train of a SAFETY SYSTEM needed for the current operating MODE AND EITHER:

Event damage has caused indications of degraded performance in a second train of a SAFETY SYSTEM needed for the current operating 111 CA6.l MODE.

Event damage has resulted in VISIBLE DAMAGE to a second train of a 186 SA9.l SAFETY SYSTEM needed for the current operating MODE.

(Notes 11, 12)"

And along with the revised EAL text, the followi ng notes were also added:

Note 11 :

If the affected SAFETY SYSTEM train was already inoperable or out of service before the hazardous event occurred, then this emergency classification is not warranted.

Note 12:

If the hazardous event only results in VISIBLE DAMAGE, with no indication of degraded performance to at least one train of a SAFETY SYSTEM, then this emergency classification is not warranted.

Page 26 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Page(s) Section or Step Description Number Removed the existing basis text following the bulleted steps and replaced with the following:

"This IC addresses a hazardous event that causes damage to SAFETY SYSTEMS needed for the current operating mode. In order to provide the appropriate context for consideration of an ALERT classification, the hazardous event must have caused indications of degraded SAFETY SYSTEM performance in one train, and there must be either indications of performance issues with the second SAFETY SYSTEM train or VISIBLE DAMAGE to the second train such that the potential exists for this second SAFETY SYSTEM train to have performance issues. In other words, in order for this EAL to be classified, the hazardous event must occur, at least one SAFETY SYSTEM train must have indications of degraded performance, and the second SAFETY SYSTEM train must have indications of degraded performance or VISIBLE DAMAGE such that the potential exists for performance issues. Note that this second SAFETY SYSTEM train is from the same SAFETY SYSTEM that has indications of degraded performance; commercial nuclear power plants are designed to be able to support single system issues without compromising public health and safety from radiological events.

Indications of degraded performance addresses damage to a SAFETY SYSTEM train that is in service/operation since indications for it will be readily available. The indications of degraded performance should be significant enough to cause concern regarding the operability or reliability of the SAFETY SYSTEM train.

Operators will make a determination of VISIBLE DAMAGE based on the totality of 113 CA6.l Basis available event and damage report information. This is intended to be a brief assessment not requiring lengthy analysis or quantification of the damage. This VISIBLE DAMAGE should be significant enough to cause concern regarding the operability or reliability of the SAFETY SYSTEM train.

An event affecting equipment common to two or more safety systems or safety system trains (i.e., there are indications of degraded performance and/or VISIBLE DAMAGE affecting the common equipment) should be classified as an Alert. By affecting the operability or reliability of multiple system trains, the loss of the common equipment effectively meets the two train impact criteria that underlie the EALs and Bases. For example, this guidance would apply to a unit with a tank that is the water source for multiple safety injection systems or trains, such as a Refueling Water Storage Tank.

An event that affects two trains of a safety system (e.g., one train has indications of degraded performance and the other VISIBLE DAMAGE) that also has one or more additional trains should be classified as an Alert. This approach maintains consistency with the two train impact criteria that underlie the EALs and Bases, and is warranted because the event was severe enough to affect the operability or reliability of two trains of a safety system despite plant design criteria associated with system and system train separation and protection. Such an event may have caused other plant impacts that are not immediately apparent. For example, this guidance would apply to a unit that has an Auxiliary/Emergency Feedwater system with three trains.

Escalation of the emergency classification level would be via !Cs CS1 or RS1."

This was done to help clarify when the EAL should be called.

115 HUI.I Basis Removed reference to HG! from classifying HOSTILE ACTIONS..

120 HSl.1 Basis Removed reference to HGl and added all other General Emergency ICs.

Old HGl.1 Deleted HGl.1 and associated reference material from bases.

Page 27 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Page(s) Section or Step Description Number Removed the existing basis text following the paragraph about a single faulted generator, and replaced with the following:

"This IC addresses a hazardous event that causes damage to SAFETY SYSTEMS needed for the current operating mode. In order to provide the appropriate context for consideration of an ALERT classification, the hazardous event must have caused indications of degraded SAFETY SYSTEM performance in one train, and there must be either indications of performance issues with the second SAFETY SYSTEM train or VISIBLE DAMAGE to the second train such that the potential exists for this second SAFETY SYSTEM train to have performance issues. In other words, in order for this EAL to be classified, the hazardous event must occur, at least one SAFETY SYSTEM train must have indications of degraded performance, and the second SAFETY SYSTEM train must have indications of degraded performance or VISIBLE DAMAGE such that the potential exists for performance issues. Note that this second SAFETY SYSTEM train is from the same SAFETY SYSTEM that has indications of degraded performance; commercial nuclear power plants are designed to be able to support single system issues without compromising public health and safety from radiological events.

Indications of degraded performance addresses damage to a SAFETY SYSTEM train that is in service/operation since indications for it will be readily available. The indications of degraded performance should be significant enough to cause concern regarding the operability or reliability of the SAFETY SYSTEM train.

Operators will make a determination of VISIBLE DAMAGE based on the totality of 188 SA9.l Basis available event and damage report information. This is intended to be a brief assessment not requiring lengthy analysis or quantification of the damage. This VISIBLE DAMAGE should be significant enough to cause concern regarding the operability or reliability of the SAFETY SYSTEM train.

An event affecting equipment common to two or more safety systems or safety system trains (i.e., there are indications of degraded performance and/or VISIBLE DAMAGE affecting the common equipment) should be classified as an Alert. By affecting the operability or reliability of multiple system trains, the loss of the common equipment effectively meets the two train impact criteria that underlie the EALs and Bases. For example, this guidance would apply to a unit with a tank that is the water source for multiple safety injection systems or trains, such as a Refueling Water Storage Tank.

An event that affects two trains of a safety system ( e.g., one train has indications of degraded performance and the other VISIBLE DAMAGE) that also has one or more additional trains should be classified as an Alert. This approach maintains consistency with the two train impact criteria that underlie the EALs and Bases, and is warranted because the event was severe enough to affect the operability or reliability of two trains of a safety system despite plant design criteria associated with system and system train separation and protection. Such an event may have caused other plant impacts that are not immediately apparent. For example, this guidance would apply to a unit that has an Auxiliary/Emergency Feedwater system with three trains.

Escalation of the emergency classification level would be via ICs FS1 or RS1."

This was done to help clarify when the EAL should be called.

Page 28 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev.016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Emergency Action Level Technical Bases The existence of "damage" is dete1mined by radiological survey. The technical specification multiple of 2 times', which is also used in Recognition Category RIC RUl, is used here to distinguish between non-emergency and emergency conditions. The emphasis for this classification is the degradation in the level of safety of the spent fuel cask and not the magnitude of the associated dose or dose rate. It is recognized that in the case of extreme damage to a loaded cask, the fact that the "on-contact" dose rate limit is exceeded may be detennined based on measurement of a dose rate at some distance from the cask.

Security-related events for ISFSis are covered under IC HS 1.

Callaway Basis Reference(s):

l. Certificate of Compliance No. 1040 Appendix A Technical Specifications for the HI-STORM UMAX Canister Storage System

2. NEl99-01, E-HUl Page 69 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Emergency Action Leve) Technical Bases Category:

C - Cold Shutdown / Refueling System Malfunction Subcategory:

6 - Hazardous Event Affecting Safety Systems Initiating Condition:

Hazardous event affecting a SAFETY SYSTEM needed for the current operating MODE EAL:

CA6.1 Alert The ocounence of any Table C-6 hazardous event AND Event damage has caused indication of degraded perfonnance on one h*ain of a SAFETY SYSTEM needed for the cuJTent o era ting MODE AND EITHER:

Event damage has caused indications of degraded perf01mance in a second train of a SAFETY SYSTEM needed for the cmTent operating MODE.

Event damage has resulted in VISIBLE DAMAGE to a second train of a SAFETY SYSTEM needed for the cuJTent o_perating MODE.

(Notes 11. 12)

Nole 11: If the affected SAFETY SYSTEM train was already inoperable or out of service before the hazardous event occurred. then this emergency classification is not warranted.

Note I]: If tJ,e hazardous event only results in VISTBLE DAMAGE. with no indication of degraded performance to ar least one train ofa SAFETY SYSTEM. then this emergency classification i 1101 warranted.

MODE Applicability:

Table C-6 Hazardous Events EXPLOSION FIRE HIGH WINDS or tornado strike Internal or external FLOODING event Seismic event (earthquake)

Other events with similar hazard characteristics as determined by the Emergency Coordinator 5 - Cold Shutdown, 6 - Refueling Page 111 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev.016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Attachment I - Emergency Action Level Technical Bases Definition(s):

EXPLOSION - A rapid violent and catastrophic failure of a piece of equipment due to combustion, chemical reaction or over pressurization. A release of steam from high energy lines or components) or an electrical component failure (caused by short circuits, grounding, arcing etc.) should not automatically be considered an explosion. Such events require a post-event inspection to detemrine if the attributes of an explosion are present.

FIRE - Combustion characterized by heat and light. Sources of s01oke such as slipping drive belts or overheated electrical equipment do not constitute fires. Observation of flame is prefened but is NOT required if large quantities of smoke and heat are observed.

FLOODING - A condition where water is ente1ing a room or area faster than installed equipment is capable of removal, resulting in a rise of water level within the room or area.

HIGH WINDS - Winds in excess of 40 mph (I 8 m/s) sustained, or 58 mph (26 mis) gusting.

SAFETY SYSTEM - A system required for safe plant operation cooling down the plant and/or placing it in the Cold Shutdown condition, including the ECCS. These are typically systems classified as safety-related (as defined in 1 OCFR50.2):

Those structures, systems and components that are relied upon to remain functional during and following design basis events to assw*e:

I.

The integrity of the reactor coo !ant pressure boundary;

2.

The capability to shut down the reactor and maintain it in a safe shutdown condition;

3.

The capabiliLy to prevent or mitigate the consequences of accidents which could result in potential offsite exposures.

VISIBLE DAMAGE - Damage to a SAFETY SYSTEM train that is readily observable without measurements testing, or analysis. The visual impact of the damage is sufficient lo cause concern regarding the o erability or reliability of the affected SAFETY SYSTEM train.

Basis:

Annunciator 98D, OBE ill illuminate if the seismic instrument detects ground motion in excess of the OBE tlu*esho1d. OTO-SG-00001, Seismic Event provides the guidance for detennining if an OBE earthquake tlu*eshold is exceeded and any required response actions (ref. I).

lntemal FLOODING may be caused by events such as comp011ent failures, equipment misalignment, or outage activity mishaps (ref. 2).

E teroal flooding may be due to high rainfall. Callaway plant grade elevation is 840.0 ft. MSL.

(ref. 3).

Seismic Catego1y I st:mctmes are analyzed to withstand a sustained, design wind velocity of at least 100 mph. (ref. 4).

Areas containing functions and systems required for safe shutdown of the plant are identified by fire area (ref. 5).

An explosion that degrades the perfo1mance of a SAFETY SYSTEM train or visibly damages a SAFETY SYSTEM component or structuse would be classified under this EAL.

Page 112 of 239 INFORMATION USE

EJP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Emergency Action Level Technical Bases This IC addresses a hazardous event that causes damage to SAFETY SYSTEMS needed for the cuJTent operating mode. 1n order to provide the appropriate context for consideration of an ALERT classification the hazardous event must have caused indications of degraded SAFETY SYSTEM perfo1mance in one train, and there must be either indications of pe1fo1mance issues with the second SAFETY SYSTEM trnin or VISIBLE DAMAGE to the second train such that the potential exists for this second SAFETY SYSTEM train to have pertornrnnce issues. 1n other words, in order for trus EAL to be classified, the hazardous event ust occur, at least one SAFETY SYSTEM train must have indications of degraded perfo1mance, and the second SAFETY SYSTEM train must have indications of degraded performance or VISIBLE DAMAGE such that the potential exists for pe1fo1mance issues. Note that this second SAFETY SYSTEM train is from the same SAFETY SYSTEM that has indications of degraded perfonuance; commercial nuclear power plants are designed to be able to su 011 single system issues without compromising public health and safety from radiological events.

Indications of degraded perfonnance addresses danrnge to a SAFETY SYSTEM train that is it service/operation since indications for it will be readily available. The indications of degraded perf01mance should be significant enough to cause concern regarding the o_perabiJjty or reliability of the SAFETY SYSTEM train.

Operators will make a determination of VISIBLE DAMAGE based on the totality of available event and damage repo11 infonnation. This is intended to be a brief assessment not requiring lengthy analysis or quantification of the damage. This VISIBLE DAMAGE should be significant enough to cause concern regarding the operability or reliability of the SAFETY SYSTEM train.

An event affecting equipment common to two or more safety systems or safety system trains (i.e., there are indications of degraded perfomrnnce and/or VISIBLE DAMAGE affecting the common equipment) should be classified as an Alert. By affecting the operability or reliability of multiple system trains, the loss of the common equipment effectively meets the two-train impact criteria that underlie the EALs and Bases. For example, this guidance would apply to a unit with a tank that is the water sow-ce for multiple safety injection systems or trains, such as a Refueling Water Storage Tanlc An event that affects two trains of a safety system (e.g., one train has indications of degraded perfomrnnce and the other VISIBLE DAMAGE) that also has one or more additional trains should be classified as an Alert. This approach maintains consistency with the two-train impact c1iteria that underlie the EALs and Bases, and is waJTanted because the event was severe enough to affect the operability or reliability of two trains of a safety system despite plant design criteria associated with system and system train separation and protection. Such an event may have caused other plant impacts that are not immediately apparent. For example, this guidance would a.QPly to a unit that has an Auxiliary/Emergency Feedwater system with tlu*ee trains.

Escalation of the emergency classification level would be via I Cs CS 1 or RS 1.

Callaway Basis Reference(s):

1.

OTO-SG-00001, Seismic Event

2.

IPE Section 3.4.2.3 Results of the Vulnerability Screening

3.

FSAR, Section 3.4 Water Level (Flood) Design Table 3.4-1 PMF, Groundwater, Reference, and Actual Plant Elevations

4.

FSAR, Section 3.3.1.1 Design Wind Loadings

5.

FSAR, Section 9.5.1 Fire Protection System

6.

NEI 99-01, CA6 Page 113 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Emergency Action Level Technical Bases Category:

H - Hazards Subcategory:

I - Security Initiating Condition:

Confirmed SECURITY CONDITION or threat EAL:

HUl.1 Unusual Event A SECURITY CONDITION that does not involve a HOSTILE ACTION as repmted by the Secutity Shift Supervisor.

OR Notification of a credible secwity threat directed at the site.

OR A validated notification from the NRC providing information of an aircraft threat.

MODE Applicability:

All Definition(s):

SECURITY CONDITION - Any security event as listed in the approved security contingency plan that constitutes a tlu*eat/compromise to site secwity, threat/risk to site personnel, or a potential degradation to the level of safety of the plant. A secw-ity condition does not involve a hostile action.

HOSTILE ACTION -An act toward Callaway or its personnel that includes tbe use of violent force to destroy equipme11t, take hostages, and/or intimidate the licensee lo achieve an end. This includes attack by air, land, or water using guns, explosives, projectiles, vehicles, or other devices used to deliver destluctive force.

Other acts that satisfy the overa11 intent may be included. Hostile action should not be cons(rued to include acts of civil disobedience or felonious acts that are not part of a concerted attack on Callaway.

Non-tenorism-based EALs should be used to address such activities (i.e., th.is may include violent acts between individuals in the owner controlled area).

Basis:

The secunty shift supervision is defined as the Security Shift Supervisor.

Th.is EAL is based on the Callaway Plant Security Plan and DBT (ref. 1).

This IC addresses events that pose a threat to plant personnel or SAFETY SYSTEM equipment and thus represent a potential degradation in the level of plant safety. Security e ents which do not meet one of these EALs are adequately addressed by the requirements of IO CFR 73.71 or 10 CFR 50.72. Security events assessed as HOSTILE ACTIONS are classifiable under ICs HA I, and HS 1.

Timely and accurate communications between Security Shift Supervision and the Control Room is essential for proper classification of a security-related event (ref 2, 3, 4 ). Classification of these eveuts will initiate appropriate threat-related notifications to plant personnel and Offsite Response Organizations.

Page 115 of239 INFORMATION USE

EIP-ZZ-0010 l ADDENDUM 2 Rev. 016 El\\1ERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Eme1*gency Action Leve) Technical Bases As time and conditions allow, these events require a heightened state of readiness by the p1ant staff and implementation of onsite protective measures (e.g., evacuation, dispersal or sheltering), Tue Site Area Emergency declaration will mobilize Offsite Response Organization (ORO) resources and have them available to develop and implement public protective actions in the unlikely event that the attack is successful in impairing multiple safety functions.

This IC does not apply to incidents that are accidentaJ events, acts of civil disobedience OJ otherwise are not a HOSTILE ACTION perpetrated by a HOSTILE FORCE. Examples include the crash of a small aircraft, shots from hunters, physical disputes between employees, etc. Reporting of d1ese types of events is adequately addressed by other EALs, or theTequirements of 10 CPR 73.71 or 10 CFR 50.72.

Emergency plans and implementing procedures are public documents* therefore, EALs should not incorporate Seourity-sensitive information. This includes information that may be advantageous to a potential adversary, such as the particulars concerning a specific threat or threat location. Security-sensitive information should be contained in non-public documents such as tbe Callaway Plant Secmity Plan and DBT (ref. l ).

Escalation. of the emergency classification level would be via I Cs RG 1, RG2, SG 1. SG2, FG 1, and CG 1.

Callaway Basis Refcrence(s):

1.

Callaway Plant Security Plan and DBT (Safeguards)

2.

E.IP-ZZ-SKOOl, Response to Security Threat

3.

SDP-CP-00003, Security Contingency Events

4.

OTO-SK-00001, Plant Security Event - Hostile Intrusion

5.

OTO-SK-00002, Plant Security Event - Aircraft Threat

6.

NEI 99-01, HSI Page 120 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Category: - Emergency Action Level Technical Bases S - System Malfunction Subcategory:

9 - Hazardous Event Affecting Safety Systems Initiating Condition:

Hazardous event affecting a SAFETY SYSTEM needed for the cwrent operating MODE EAL:

SA9.1 Alert The occuITence of any Table S-5 hazru*dous event AND Event damage has caused indication of degraded e1formance on one train of a SAFETY SYSTEM eeded for the cunent operating MODE AND EITHER:

Event damage has caused indications of degraded pe1fonnance in a second lTain of a SAFETY SYSTEM needed for the current oQ.erating MODE.

Event damage bas resulted in VISIBLE DAMAGE to a second train of a SAFETY SYSTEM needed for the cunent o erating MODE.

(Notes JI. 11)

Nore 11: If the affected SAFETY SYSTEM train was already inoperable or out of service before the hazardous event occurred, then this emergency classification is not warranted.

Nore 11: lfthe hazardou event on ly results in VISJBLE DAMAGE, with no indication of degraded performance to at least one train of a SAFETY SYSTEM, then this emergency classification is not warranted.

MODE Applicability:

Table 5-5 Hazardous Events EXPLOSION FIRE HIGH WINDS or tornado strike Internal or external FLOODING event Seismic event (earthquake)

Other events with similar hazard characteristics as determined by the Emergency Coordinator 1 - Power Operation, 2 - Strutup, 3 - Hot Standby, 4 - Hot Shutdown Page 186 of239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT Attachment l - Emergency Action Level Technical Bases Definition(s):

ElCPLOSJON - A rapid, violent and catastrophic failure of a piece of equipment due to combustion chemical reaction or over pressurization. A release of steam (from high energy lines or components) or an electrical component failure ( caused by short circuits grounding, arcing, etc.) should not automatically be considered an explosion. Such events require a post-e ent inspection to detennine if the attributes of an explosion are present.

FJRE - Combustion characterized by heat and light. Sources of smoke such as slipping drive belts or overheated electrical equipment do not constitute fires. Observation of flame is prefe1Ted but is NOT required if large quantities of smoke and heat are observed.

FLOODING - A condition where water is entering a room or area faster than installed equipment is capable ofremoval resulting in a rise of water level within the room or area.

JllGH WINDS - Winds in excess of 40 mph (18 mis) sustained or 58 m.ph (26 mis) gusting.

SAFETY SYSTEM - A system required for safe plant operation, cooling down the plant and/or placing it in the Cold Shutdown condition, including the ECCS. These are typically systems classified as safety-related (as defined in 10CFR50.2):

Those strnctures, systems and components that are relied upon to remain functional dwing and following design basis events to assure:

1.

The integrity of the reactor coolant pressure boundary;

2.

The capability to shut down the reactor and maintain it in a safe shutdown condition;

3.

The capability to prevent or mitigate the consequences of accidents which could result i11 potential offsite exposures.

VISIBLE DAMAGE-Damage to a SAFETY SYSTEM train that is readily obse1vable without measurements, testing, or analysis. The visual impact of the damage is sufficient to cause concern regarding the operability or reliability of the affected SAFETY SYSTEM train.

Basis:

Annunciator 98D, OBE will iiluminate if the seismic inslmment detects ground motion in excess of the OBE threshold. OTO-SG-0000 I, Seismic Event prnvides the guidance for determining if an OBE earthquake threshold is exceeded and any required response actions (ref. 1 ).

Intemal FLOODING may be caused by events su h as component failures equipment misalignment, or outage activity mishaps (ref 2).

External flooding may be due to high lake level. Callaway plant grade elevation is 840.0 ft. MSL.

(ref. 3 ).

Seismic Category I structures are analyzed to wid1stand a sustained, de ign wjnd velocity of at least 100 mph. (ref. 4).

Areas containing functions and systems required for safe shutdown of the plant are identified by fire area (ref 5).

An explosion that degrades the performance of a SAFETY SYSTEM train or visibly damages a SAFETY SYSTEM component or structure would be classified under this EAL.

A single FAUL TED steam generator would NOT require declaration per this EAL. Technical Specification Bases 3.7.4 explains that two intact Steam Generators are required for cooldown of the RCS and a third Steam Generator :is assumed to be RUPTURED. If more than one Steam Generator is FA UL TED, then this EAL is applicable.

Page 187 of 239 INFORMATION USE

EIP-ZZ-00101 ADDENDUM 2 Rev. 016 EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT - Emergency Action Level Technical Bases This IC addresses a hazardous event that causes damage to SAFETY SYSTEMS needed for the current operating mode. In order to provide the approp1iate context for consideration of an ALERT classification, the hazardous event must have caused indications of degraded SAFETY SYSTEM performance in one train, and there must be either indications of perfo1mance issues with the second SAFETY SYSTEM train or VISIBLE DAMAGE to the second train such that the potential exists for this second SAFETY SYSTEM train to have performance issues. In other words, in order for this EAL to be classified, the hazardous event must occur, at least one SAFETY SYSTEM train must have indications of degraded perfom1ance, and the second SAFETY SYSTEM train must have indications of degraded perfo1mance or VISIBLE DAMAGE such that the potential exists for perfomrnnce issues. Note that this second SAFETY SYSTEM train is from the same SAFETY SYSTEM that has indications of degraded perfonnance; commercial nuclear power plants are designed to be able to support single system issues without com2romising ublic health and safety from radiological events.

Indications of degraded perfomrnnce addresses damage to a SAFETY SYSTEM train that is in se1vice/operation since indications for it will be readily available. The indications of degraded perfonnance should be significant enough to cause concern regarding the o erability or reliability of the SAFETY SYSTEM train.

Operators will make a detem1ination of VISIBLE DAMAGE based on the totality of available event and damage rep01t info1mation. This is intended to be a b1ief assessment not requiring lengthy analysis or quantification of the damage. This VISIBLE DAMAGE should be significant enough to cause concern regarding the 02erability or reliability of the SAFETY SYSTEM train.

An event affecting equipment common to two or more safety systems or safety system trains (i.e., there are indications of degraded performance and/or VISIBLE DAMAGE affecting the common equipment) should be classified as an Alert. By affecting the operability or reliability of multiple system trains, the Joss of the common equipment effectively meets the two-train impact crite1ia that underlie the EALs and Bases. For example, this guidance would apply to a unit with a tank that is the water source for multiple safety injection systems or trains, such as a Refueling Water Storage Tanlc An event that affects two trains of a safety system (e.g., one train has indications of degraded perfomrnnce and the other VISIBLE DAMAGE) that also has one or more additional trains should be classified as an Alert. This approach maintains consistency with the two-train impact criteria that underlie the EALs and Bases, and is wan-anted because the event was severe enough to affect the operability or reliability of two trains of a safety system despite plant design criteria associated with system and system train separation and protection. Such an event may have caused other plant impacts that are not immediately apparent. For example, this guidance would a_p12ly to a unit that has an Auxilimy/Emergency Feedwater system with three trains.

Escalation of the emergency classification level would be via ICs FS I or RS 1.

Callaway Basis Reference(s):

1.

OTO-SG-00001, Seismic Event

2.

IPE Section 3.4.2.3 Results of the Vulnerability Screening

3.

FSAR, Section 3.'4 Water Level (Flood) Design Table 3.4-1 PMF, Groundwater, Reference, and Actual Plant Elevations

4.

FSAR, Section 3.3.1.1 Design Wind Loadings

5.

FSAR, Section 9.5.1 Fire Protection System

6.

NEl 99-01, SA9 Page 188 of239 INFORMATION USE