ML19007A037

From kanterella
Jump to navigation Jump to search
LC-FS-TSD-002, Rev. 2, Operational Derived Concentration Guideline Levels for Final Status Survey
ML19007A037
Person / Time
Site: La Crosse File:Dairyland Power Cooperative icon.png
Issue date: 05/28/2018
From: Fauver D
Energy Solutions
To:
Office of Nuclear Material Safety and Safeguards
M VAALER DUWP
Shared Package
ML19007A031 List:
References
LC-FS-TSD-002, Rev 2
Download: ML19007A037 (18)


Text

EnergySolutions Technical Support Document LC-FS-TSD-002 OPERATIONAL DERIVED CONCENTRATION GUIDELINE LEVELS FOR FINAL STATUS SURVEY Revision 2 Originator: Date: 05/28/18 David Fauver Reviewer: Date: 05/29/18 Eric Darois Approval: Date: 05/29/18 Robert Yetter

LC-FS-TSD-002 Revision 2 Page 2 of 18 Summary of Changes in this Revision:

Revision 0 - Initial Issuance Revision 1 - Revise Buried Pipe Base Case DCGLs and Operational DCGLs to address additions to the list of buried pipe to remain. Corrected minor typographical errors.

Revision 2 - Revise Buried Pipe Circulating Water Discharge Base Case DCGL for Sr-90 from 7.56E+05 to 7.55E+05 and OpDCGL for Sr-90 from 1.59E+05 to 1.58E+05

LC-FS-TSD-002 Revision 2 Page 3 of 18 TABLE OF CONTENTS

1.

PURPOSE.................................................................................................................................. 5

2.

COMPLIANCE DOSE CALCULATIONS.............................................................................. 5 2.1. Max SOFEGW Term........................................................................................................... 6 2.2. Max BcSOFSOIL Term....................................................................................................... 7 2.3. Max BcSOFBURIED PIPE Term............................................................................................ 8 2.4. Max BcSOFAG BUILDING Term........................................................................................... 8 2.5. Max BcSOFBASEMENT Term.............................................................................................. 9 2.6. Max GW BcSOFBS OB Term............................................................................................. 9 2.7. Max GW BcSOFBPS OBP Term........................................................................................ 10

3.

OPERATIONAL DCGLS....................................................................................................... 11

4.

BASIS FOR DETERMINING OPERATIONAL DCGLS..................................................... 12

5.

DETERMINATION OF A PRIORI DOSE FRACTIONS...................................................... 15

6.

OPERATIONAL DCGL VALUES......................................................................................... 16

7.

References................................................................................................................................ 18 LIST OF TABLES Table 1 Base Case Basement DCGLBS........................................................................................ 13 Table 2 Base Case DCGLB.......................................................................................................... 13 Table 3 Base Case DCGLs for Soil (DCGLS)............................................................................. 13 Table 4 Base Case DCGLs for Buried Pipe (DCGLBP)............................................................... 13 Table 5 Base Case DCGLs for Above Grade Buildings (DCGLAGB)......................................... 14 Table 6 Exposure Factors for Existing Groundwater.................................................................. 14 Table 7 a priori Dose Fractions................................................................................................... 15 Table 8 Operational DCGLs for Basement Scenarios (OpDCGLBS) and Basement (OpDCGLB)

.16 Table 9 Operational DCGLs for Basements (OpDCGLB)........................................................... 16 Table 10 Operational DCGLs for Soil (OpDCGLS)...................................................................... 16 Table 11 Operational DCGLs for Buried Pipe Scenarios.............................................................. 17 Table 12 Operational DCGLs for Buried Pipe (OpDCGLBP)........................................................ 17 Table 13 Operational DCGLs for Above Grade Buildings (OpDCGLAGB).................................. 17

LC-FS-TSD-002 Revision 2 Page 4 of 18 LIST OF ACRONYMS AND ABBREVIATIONS AMCG Average Member of the Critical Group BcSOF Base Case DCGL Sum of Fractions DCGL Derived Concentration Guideline Levels FSS Final Status Survey LACBWR La Crosse Boiling Water Reactor MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual OpDCGL Operational DCGL OpSOF Operational DCGL Sum of Fractions ROC Radionuclide of Concern SOF Sum-of-Fractions TEDE Total Effective Dose Equivalent TSD Technical Support Document

LC-FS-TSD-002 Revision 2 Page 5 of 18

1. PURPOSE Derived Concentration Guideline Levels (DCGL) are established to demonstrate compliance with the 25 mrem/yr unrestricted use criterion in EnergySolutions Technical Support Document (TSD) RS-TD-313196-004 LACBWR Soil DCGL and Basement Concrete DCGL, Revision 3 (1). DCGLs are calculated by analysis of various pathways (direct radiation, inhalation, ingestion, etc.), media (e.g.,

concrete, buried pipe, soil, existing groundwater and standing buildings) and scenarios through which exposures could occur.

RS-TD-313196-004 (1) describes the approach, modeling parameters and assumptions used to develop the DCGLs (referred to as Base Case DCGLs in this TSD) for each Radionuclide of Concern (ROC) that will be used for the Final Status Survey (FSS) of La Crosse Boiling Water Reactor (LACBWR) site. The Base Case DCGLs for each ROC, in each media, represent the concentration that would result in a dose of 25 mrem/yr for that ROC and media independently after adjusting for the dose from insignificant contributor radionuclides. Compliance is demonstrated through the summation of dose from each of the ROCs in each of the five media (basement concrete, soil, buried pipe standing buildings and existing groundwater). The LACBWR basements do not contain embedded pipes or penetrations.

To ensure that the dose summation from the residual radioactivity in each of the five media is 25 mrem/yr or less after all FSS is completed, the Base Case DCGLs for each media are reduced based on an assigned, or a priori, fraction of the 25 mrem/yr dose criterion. The reduced DCGLs are designated as Operational DCGLs. The summation of the dose from all ROC, in all five media (also referred to as source terms in this TSD), will equal 25 mrem/yr if residual radioactivity is present at the Operational DCGL concentrations.

This TSD describes the derivation of the a priori dose fractions and the corresponding Operational DCGLs for each ROC in each of the five media. Also provided are the equations for calculating each term in the Compliance Dose calculation shown in Equation 1.

2. COMPLIANCE DOSE CALCULATIONS Each radionuclide-specific Base Case DCGL is equivalent to the level of residual radioactivity (above background levels) that could, when considered independently, result in a Total Effective Dose Equivalent (TEDE) of 25 mrem per year to the Average Member of the Critical Group (AMCG).

When applied to backfilled basement surfaces below 639 foot elevation the DCGLs are expressed in units of activity per surface area (pCi/m2). When applied to soil, the DCGLs are expressed in units of activity per unit of mass (pCi/g). For buried piping and above grade buildings, DCGLs are expressed in units of activity per surface area (dpm/100 cm2). The units for existing groundwater are pCi/L.

The unity rule is applied when there is more than one ROC in a given media. The measurement results for each singular ROC present in the mixture are compared against their respective DCGL to derive a dose fraction. The summation of the dose fractions for each ROC produces a Sum-of-Fractions (SOF) for the measurement. When compared against the Base Case DCGL, the term is defined as BcSOF. When compared against the Operational DCGL, the term is defined as OpSOF.

Demonstrating compliance with the dose criterion requires the summation of dose from the five media as shown in Equation 1. Note that there are five media but seven dose terms in Equation 1. The BcSOFGWOB term is calculated using the FSS results from the basement media. The BcSOFBBPS OBP term is calculated using the FSS results from the buried pipe media.

LC-FS-TSD-002 Revision 2 Page 6 of 18 Equation 1 Compliance Dose = (Max BcSOFBASEMENT + Max BcSOFSOIL + Max BcSOFBURIED PIPE +

BcSOFAG BUILDING + GW BcSOFBS OB + GW BcSOFBPS OBP + Max SOFEGW) x 25 mrem/yr where:

Compliance Dose

=

must be less than or equal to 25 mrem/yr, Max BcSOFBASEMENT

=

Maximum BcSOF (mean of FSS systematic results plus the dose from any identified elevated areas) for backfilled Basements, Max BcSOFSOIL

=

Maximum BcSOF (mean of FSS systematic results plus the dose from any identified elevated areas) for open land survey units, Max BcSOFBURIED PIPE =

Maximum BcSOF (mean of FSS systematic results plus the dose from any identified elevated areas) from buried piping survey units, Max BcSOFAG BUILDING =

Maximum BcSOF (mean of FSS systematic results plus the dose from any identified elevated areas) from above grade standing building survey units, GW BcSOFBS OB

=

Groundwater scenario dose from the Other Basement (OB) which is defined as the basement not used to generate the Max BcSOFBASEMENT term in Equation 1 GW BcSOFBPS OBP

=

Groundwater scenario dose from the Other Buried Pipe (OBP) which is defined as the buried pipe survey unit not used to generate the Max BcSOFBURIED PIPE term in Equation 1 Max SOFEGW

=

Maximum SOF from existing groundwater (EGW) 2.1.Max SOFEGW Term The dose for the Max SOFEGW term will be determined based on the analysis of water samples taken from the active sample wells established at and around LACBWR which are monitored on a routine frequency. These wells will remain active and will be monitored through license termination. The two years of monitoring prior to Final Report submittal will be used to establish the Max SOFEGW. If groundwater contamination is identified during decommissioning (during the period when the wells are active and monitored), then the dose will be calculated using the Groundwater Exposure Factors in RS-TD-313196-004, Revision 3 (1).

The maximum SOF for existing groundwater Max SOFEGW will be calculated if radionuclides are positively identified by groundwater monitoring. If groundwater contamination is identified by groundwater monitoring, the maximum SOF will be calculated from the maximum concentration from groundwater sampling for each positively identified ROC in units of pCi/L in accordance with Equation 2:

LC-FS-TSD-002 Revision 2 Page 7 of 18 Equation 2

=

25

=1 where:

Max SOFEGW

= Maximum SOF for existing groundwater ConcROCi

= Maximum concentration from all groundwater sampling wells collectively for each positively identified ROCi in units of pCi/L within the most recent two years of sampling. (Note that this has the potential of combining results from various wells if different ROC are positively identified in different wells)

EFGWi

= Groundwater Exposure Factors for ROCi in units of mrem/yr per pCi/L 2.2.Max BcSOFSOIL Term BcSOFSOIL will be derived for each open land survey unit in accordance with Equation 3. This equation is equivalent to Equation 8-2 from section 8.5.2 of NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (2). As stated in section 8.5.2, if there is more than one elevated area, a separate term should be included in each.

Equation 3

=

=1

+

( )

[ x ()]

where:

BcSOFSOIL

= SOF for open land survey unit using Base Case DCGLs Mean Conc SoilROCi

= Mean concentration for the systematic measurements taken during the FSS of soils in survey unit for ROCi Base Case Soil DCGLROCi = Base Case DCGL for soils (surface soils [DCGLSS] or subsurface soils [DCGLSB] as applicable) for ROCi Elev Conc SoilROCi

= Concentration for ROCi in elevated area AFROCi

= Area Factor for ROCi The Max BcSOFSOIL term will be the highest BcSOFSOIL determined in accordance with Equation 3 from the FSS of all open land survey units.

LC-FS-TSD-002 Revision 2 Page 8 of 18 2.3.Max BcSOFBURIED PIPE Term BcSOFBURIED PIPE for buried pipe will be derived for each buried pipe survey unit in accordance Equation 4. This equation is equivalent to Equation 8-2 from section 8.5.2 of NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (2). As stated in section 8.5.2, if there is more than one elevated area, a separate term should be included in each.

Equation 4

=

=1

+

( )

[ x (

)]

where:

BcSOFBURIED PIPE

= SOF for buried pipe survey unit using Base Case DCGLs Mean Conc BPROCi

= Mean concentration for the systematic measurements taken during the FSS of buried pipe in survey unit for each ROCi Base Case BP DCGLROCi = Base Case DCGL for buried pipe (DCGLBP) for each ROCi Elev Conc BPROCi

= Concentration for ROCi in elevated area SAElev

= surface area of the elevated area SASU

= surface area of FSS unit The Max BcSOFBURIED PIPE term will be the highest BcSOFBURIED PIPE determined in accordance with Equation 4 from the FSS of all buried pipe survey units.

2.4.Max BcSOFAG BUILDING Term BcSOFAG BUILDING for above grade buildings will be derived for each above grade building survey unit in accordance with Equation 5.

Equation 5 AG BUILDING =

=1 where:

BcSOFAG BUILDING

= SOF for above grade building survey unit using Base Case DCGLs Mean Conc AG Building ROCi

= Mean concentration for the systematic measurements taken during the FSS of above grade buildings in survey unit for ROCi

LC-FS-TSD-002 Revision 2 Page 9 of 18 Base Case AG Building DCGLROCi

= Base Case DCGL for above grade buildings (DCGLAGB) for ROCi The Max BcSOFAG BUILDING term will be the highest BcSOFAG BUILDING determined in accordance with Equation 4 from the FSS of all buried pipe survey units.

2.5.Max BcSOFBASEMENT Term A Basement survey unit is comprised of the walls and floors of a Basement. The areal extent of the walls and floors is the surface area and includes both volumetric and surface contamination within the defined area. The surfaces are comprised of concrete and the remaining steel liner for the Reactor Building. Each of the Basements to remain (Reactor Building and WGTV) contains one survey unit that includes all walls and floors. BcSOFBASEMENT will be derived for the Basement wall and floor surface survey unit in accordance with Equation 6. This equation is equivalent to Equation 8-2 from section 8.5.2 of NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) (2). As stated in section 8.5.2, if there is more than one elevated area, a separate term should be included in each.

Equation 6

=

=1

+

( )

[ x (

)]

where:

BcSOFB

= SOF for structural surface survey unit within a Basement using Base Case DCGLs Mean ConcB ROCi

= Mean concentration for the systematic measurements taken during the FSS of structural surface in survey unit for each ROCi Base Case DCGLB ROCi

= Base Case DCGL for structural surfaces (DCGLB) for each ROCi Elev ConcB ROCi

= Concentration for ROCi in elevated area SAElev

= surface area of the elevated area SASU

= surface area of FSS unit 2.6.Max GW BcSOFBS OB Term The MAX GW BcSOFBS OB is the Groundwater Basement Scenario dose from the Other Basement which is defined as the basement that is not used to calculate the MAX BcSOFBASEMENT in Equation 1.

For example, if the mean of the FSS data from the Reactor Building survey unit is higher than the mean of the FSS data from the WGTV, then the Reactor Building FSS mean will be used to calculate the Max BcSOFBASEMENT term in Equation 1. The WGTV would therefore be assigned as the Other Basement.

LC-FS-TSD-002 Revision 2 Page 10 of 18 The dose modeling for the basements includes three scenarios; groundwater, drilling spoils, and excavation. DCGLs are calculated for each scenario separately (DCGLBS) and for the summation of dose from all scenarios (DCGLB). The DCGLBS for the drilling spoils and the excavation scenarios are equal for the Reactor Building and WGTV. The MAX BcSOFBASEMENT term therefore maximizes the drilling spoils and excavation pathways for both basements.

The GW DCGLBS for the Reactor Building and WGTV are not equal due to geometry considerations.

Each basement was modeled as a separate source term. Conceptually, the modeled groundwater concentrations from the two basements could mix at a location downstream of both basements in such a way as to increase the concentration that would result from each basement separately. To conservatively account for this conceptual possibility, the groundwater pathway dose from the Other Basement will be added to the Compliance Dose (Equation 1) through the GW BcSOFBS OB term.

GW BcSOFBS OB will be calculated for the basement wall and floor surface survey unit of the Other Basement in accordance with Equation 7.

Equation 7

=

=1 where:

GW BcSOFBS OB

=

SOF for the groundwater pathway only from the structural surface survey unit in the Other Basement using Base Case DCGLs applicable to the groundwater scenario only Mean ConcOB ROCi

=

Mean concentration for the systematic measurements taken in the Other Basement during the FSS of the structural surface in survey unit for ROCi GW DCGLBS OB ROCi

= Base Case DCGL for Basement Scenario Groundwater (Table 1) in the Other Basement for ROCi 2.7.Max GW BcSOFBPS OBP Term The MAX GW BcSOFBPS OBP is the dose from the Groundwater Buried Pipe Scenario (designated as Insitu in Table 11) from the Other Buried Pipe (OBP) which is defined as the buried pipe survey unit that is not used to calculate the MAX BcSOFBURIED PIPE in Equation 1. For example, if the mean of the FSS data from the buried pipe Group survey unit is higher than the mean of the FSS data from the buried pipe Circulating Water Discharge Pipe survey unit, then the Group survey unit FSS mean will be used to calculate the Max BcSOFBURIED PIPE term in Equation 1. The Circulating Water Discharge Pipe would therefore be assigned as the Other Buried Pipe.

The dose modeling for the buried pipe includes two scenarios, Insitu (i.e., groundwater) and Excavation. Buried Pipe DCGLs are calculated for each scenario separately (DCGLBPS) and for the summation of dose from both scenarios (DCGLBP).

Each buried pipe was modeled as a separate source term. Conceptually, the modeled groundwater concentrations from the two buried pipe survey units could mix at a location downstream of both survey units in such a way as to increase the concentration, and corresponding dose, that would result from each basement separately. To conservatively account for this conceptual possibility, the

LC-FS-TSD-002 Revision 2 Page 11 of 18 groundwater pathway dose from the Other Buried Pipe will be added to the Compliance Dose calculation (Equation 1) through the GW BcSOFBPS OBP term.

GW BcSOFBPS OBP will be derived for the Other Buried Pipe survey unit in accordance with Equation 8.

Equation 8

=

=1 where:

GW BcSOFBPS OBP

=

SOF for the groundwater pathway only from the survey unit in the Other Buried Pipe using Base Case DCGLBS applicable to the groundwater scenario only (i.e., Insitu).

Mean ConcOBP ROCi

=

Mean concentration for the systematic measurements taken in the Other Buried Pipe during the FSS of the survey unit for ROCi GW DCGLBPS OBP ROCi

= Base Case DCGLBPS for groundwater scenario (Insitu in Table 11) in the Other Buried Pipe for ROCi

3. OPERATIONAL DCGLS Each Base Case DCGL equates to 25 mrem/yr. To ensure that the summation of dose from each source term in Equation 1 is less than the 25 mrem/yr dose criteria after all FSS is completed, the Base Case DCGLs for each media are reduced to correspond to an assigned, or a priori, fraction of 25 mrem/yr. The summation of the assigned a priori fractions is required to be one, i.e., correspond to 25 mrem/yr. These derived lower DCGLs are designated as the Operational DCGLs (OpDCGL). Since Operational DCGLs by definition are a fraction of the Base Case DCGLs, compliance with the Operational DCGLs will ensure compliance with the Base Case DCGLs in each survey unit.

Operational DCGLs are calculated for each ROC, in each media, using Equation 9. The Operational DCGL is then used as the DCGL for the FSS design of the survey unit (calculation of surrogate DCGLs, investigations levels, etc.).

Equation 9

,=,

where:

Operational DCGL ROCm,i

=

Operational DCGL for ROCi in mediam fm

=

a priori fraction assigned to mediam Base Case DCGLROCi,m

=

Base Case DCGL for ROCi in mediam To demonstrate that each survey unit satisfies the Operational DCGL, the ROC concentrations in each systematic sample/measurement taken in each FSS unit for basements, soil, buried pipe and above grade buildings will be divided by the applicable OpDCGLB for basement surfaces, OpDCGLS for soil, OpDCGLBP for buried pipe, OpDCGLAGB for above grade buildings. and summed to derive a OpSOF

LC-FS-TSD-002 Revision 2 Page 12 of 18 for the sample/measurement. The actual recorded value will be used as the recorded FSS result for all measurement and/or sample values including those that are less than MDC. The OpSOF will be used as the summed value (Ws) for performing the Sign Test. The Sign Test will be performed separately for each survey unit.

If the OpSOF for a systematic sample/measurement (based on the Operational DCGL) exceeds one in a Class 1 or Class 2 survey unit, or 0.5 in a Class 3 survey unit, then an investigation will be initiated in accordance with LTP Chapter 5. For basement surfaces, the MDC of the In Situ Object Counting System (ISOCS) is more than adequate to detect the ROC at the investigation levels. In Class 3 and Class 2 FSS units, the result of the investigation (confirmed OpSOF greater than 0.5 in a Class 3 FSS unit or greater than one in a Class 2 FSS unit) will prompt the reclassification of the survey unit (or a portion of the survey unit).

The results of any judgmental sample/measurements will also be compared to the OpSOF (based on the Operational DCGL). As with a systematic sample/measurement, any judgmental sample/measurement that exceeds a SOF of one in a Class 1 or Class 2 survey unit, or 0.5 in a Class 3 survey unit, will prompt an investigation, reclassification and/or resurvey as applicable.

The BcSOF calculations described in Equation 3, Equation 4, and Equation 6 for soil, buried pipe, and basements, respectively, include the dose from elevated systematic and/or judgmental measurements where elevated is defined as any measurement that exceeds the OpSOF.

In Basements and Buried Pipe, any areas of elevated residual radioactivity exceeding the Base Case DCGLB will be remediated. In Class 1 open land FSS units, any areas of elevated residual radioactivity above the DCGLEMC will be remediated. The DCGLEMC calculation for soil will use Base Case DCGLs (Table 3). Area Factors from RS-TD-313196-004, Revision 3 (1) and the EMC comparison in accordance with LTP Chapter 5. Note that the soil FSS unit must pass the Sign Test using Operational DCGLs for this to occur.

The BcSOF calculation for above grade buildings, groundwater pathway in Other Basement and groundwater pathway in Other Buried Pipe. (Equation 5, Equation 7, and Equation 8, respectively) do not include a term for elevated areas. Any systematic and/or judgmental measurement in above grade buildings that exceeds the OpSOF will be remediated. Equation 7 will apply the systematic measurements in the Other Basement (after the Other Basement passes the sign test using the Operational DCGLB values). Equation 8 will apply the systematic measurements in the Other Buried Pipe survey unit (after the Other Buried Pipe survey unit passes the sign test using the Operational DCGLBP values).

4. BASIS FOR DETERMINING OPERATIONAL DCGLS With the exception of the Above Grade Building, the Base Case DCGLs (and existing groundwater exposure factor) are from RS-TD-313196-004, Revision 3 (1). The Base Case DCGLs for Above Grade Buildings are the screening values from US Nuclear Regulatory Commission, NUREG 1757, Vol. 1, Rev. 2, Consolidated Decommissioning Guidance, Final Report, September 2006 (3). The Base Case DCGLs, and the existing groundwater exposure factors, are provided in Table 1 to Table 6.

LC-FS-TSD-002 Revision 2 Page 13 of 18 Table 1 Base Case Basement DCGLBS ROC Reactor Building DCGLBS Waste Gas Tank Vault DCGLBS Groundwater Scenario Drilling Spoils Scenario Excavation Scenario Groundwater Scenario Drilling Spoils Scenario Excavation Scenario (pCi/m2)

(pCi/m2)

Co-60 1.21E+08 4.75E+08 5.45E+06 6.23E+07 3.86E+08 4.43E+06 Sr-90 1.46E+07 2.70E+11 2.80E+09 6.42E+06 2.20E+11 2.28E+09 Cs-137 1.98E+08 1.94E+09 2.47E+07 1.52E+08 1.58E+09 2.01E+07 Eu-152 2.73E+09 1.00E+09 1.21E+07 2.28E+09 8.16E+08 9.84E+06 Eu-154 1.88E+09 9.43E+08 1.12E+07 1.57E+09 7.67E+08 9.12E+06 Table 2 Base Case DCGLB ROC Rx Bldg DCGLB (pCi/m2)

WGTV DCGLB (pCi/m2)

Co-60 5.16E+06 4.10E+06 Sr-90 1.45E+07 6.40E+06 Cs-137 2.17E+07 1.76E+07 Eu-152 1.19E+07 9.69E+06 Eu-154 1.10E+07 8.97E+06 Table 3 Base Case DCGLs for Soil (DCGLS)

ROC Adjusted DCGL (pCi/g)

Co-60 1.06E+01 Sr-90 5.47E+03 Cs-137 4.83E+01 Eu-152 2.36E+01 Eu-154 2.19E+01 Table 4 Base Case DCGLs for Buried Pipe (DCGLBP)

ROC Buried Pipe Group (dpm/100 cm2)

Buried Pipe Circulating Water Discharge (dpm/100 cm2)

Co-60 7.50E+04 7.75E+04 Sr-90 5.16E+05 7.55E+05

LC-FS-TSD-002 Revision 2 Page 14 of 18 Cs-137 3.18E+05 3.30E+05 Eu-152 1.64E+05 1.67E+05 Eu-154 1.52E+05 1.56E+05 Table 5 Base Case DCGLs for Above Grade Buildings (DCGLAGB)

ROC Above Grade Building (dpm/100 cm2)

Co-60 7100 Sr-90 8700 Cs-137 28000 Eu-152 12700 Eu-154 11500 Table 6 Exposure Factors for Existing Groundwater ROC GW Exposure Factor (mrem/yr per pCi/L)

Co-60 8.80E-03 Cs-137 1.64E-02 Sr-90 4.64E-02 H-3 2.09E-05 Eu-152 2.12E-03 Eu-154 3.12E-03 The Base Case DCGLs represent the 25 mrem/yr dose criteria. Therefore, a reduction is required to ensure compliance with Equation 1 after all FSS is complete. The reduced DCGLs, designated as Operational DCGLs, are calculated by multiplying the Base Case DCGLs by the assigned a priori fraction of the dose criterion which is calculated by Equation 10.

Equation 10

=

25 where:

f

=

a priori assigned fraction of dose Dassigned =

a priori assigned dose based on characterization, FSS results to date, process knowledge, the extent of planned remediation, and instrument MDC 25

=

25 mrem/yr dose criterion for unrestricted release

LC-FS-TSD-002 Revision 2 Page 15 of 18 An a priori fraction is assigned for each of the terms in Equation 1 (basements, soil, buried pipe, above grade buildings, Other Basement, Other Buried Pipe and existing groundwater) such that the summation of the a priori fractions assigned to all media is one as shown in Equation 11.

Equation 11

+ + + + + + = 1 where:

fBasement =

a priori fraction of dose for maximum basement survey unit fsoil

=

a priori fraction of dose for maximum soil survey unit fBP

=

a priori fraction of dose for maximum buried pipe survey unit fAGB

=

a priori fraction of dose for maximum above grade building fGWOB

=

a priori fraction of groundwater dose for Other Basement fGWOBP

=

a priori fraction of groundwater dose for Other Buried Pipe fEGW

=

a priori fraction of dose for maximum existing groundwater If the actual dose fraction for any survey unit in any media, based on the mean of FSS results, exceeds the a priori fraction listed in this TSD (Revision 0), then additional remediation will be required to reduce the actual maximum dose fraction to a level less than or equal to the a priori fraction.

The FSS of the various media (basements, soil, buried pipe, and standing buildings) will be completed at different times as the project proceeds. After FSS is completed for a given media, the actual maximum fraction of allowable dose (i.e., the BcSOF term from Equation 1) will be calculated. The actual dose fraction from the maximum survey unit in the given media will be compared to the a priori dose fraction assigned to the media in this TSD (Revision 0). If the difference is large enough to justify an adjustment (i.e., increase) to the a priori fractions assigned to one or more of the other Source Term/Media (see Table 7), or other issues arise as the project proceeds that drive the need to adjust the a priori fractions and Operational DCGLs in this TSD (Revision 0), then a revision (Revision 1) will be issued.

If Revision 1 of this TSD is issued, the new Operational DCGLs will be applied in subsequent FSS survey design packages and release records. All FSS performed prior to the issuance of Revision 1 (if necessary) will comply with the Operational DCGLs documented in this TSD (Revision 0). Existing FSS packages will be reviewed but revisions will not be required for media where the Operational DCGLs in Revision 1 are higher than those in Revision 0, or for any media that has fully completed FSS and the calculation of Max BcSOF term in Equation 1 is completed, prior to the issuance of Revision 1 (if necessary).

5. DETERMINATION OF A PRIORI DOSE FRACTIONS Using the results of characterization, FSS completed to date, process knowledge, the extent of expected remediation, and instrument MDC, the a priori dose fractions assigned to each media are provided in Table 7. The a priori fractions in Table 7 are used to calculate the Operational DCGLs in accordance with Equation 9.

Table 7 a priori Dose Fractions

LC-FS-TSD-002 Revision 2 Page 16 of 18 FSS Unit Source Term/Media for FSS a priori Fraction, f Basement Floor and Walls 0.07 Groundwater Other Basement Floor and Walls 0.01 Soil Soil 0.36 Buried Pipe Buried Pipe 0.21 Groundwater Other Buried Pipe Buried Pipe 0.06 Above Grade Building Floor, Walls, Ceiling 0.16 Existing Groundwater Groundwater Monitoring Results 0.13 Sum 1.0

6. OPERATIONAL DCGL VALUES Operational DCGLs are calculated by multiplying the Base Case DCGLs (Table 1 to Table 6) by the applicable a priori fraction of dose in Table 7 as shown in Equation 9.

The operational DCGLs for FSS at LACBWR are provided in Table 8 to Table 13.

Table 8 Operational DCGLs for Basement Scenarios (OpDCGLBS) and Basement (OpDCGLB)

ROC Reactor Building OpDCGLBS Waste Gas Tank Vault OpDCGLBS Groundwater Scenario Drilling Spoils Scenario Excavation Scenario Groundwater Scenario Drilling Spoils Scenario Excavation Scenario (pCi/m2)

(pCi/m2)

Co-60 8.46E+06 3.32E+07 3.81E+05 4.36E+06 2.70E+07 3.10E+05 Sr-90 1.02E+06 1.89E+10 1.96E+08 4.49E+05 1.54E+10 1.60E+08 Cs-137 1.38E+07 1.36E+08 1.73E+06 1.06E+07 1.10E+08 1.41E+06 Eu-152 1.91E+08 7.02E+07 8.47E+05 1.60E+08 5.71E+07 6.89E+05 Eu-154 1.32E+08 6.60E+07 7.85E+05 1.10E+08 5.37E+07 6.39E+05 Table 9 Operational DCGLs for Basements (OpDCGLB)

ROC Rx Bldg OpDCGLB (pCi/m2)

WGTV OpDCGLB (pCi/m2)

Co-60 3.61E+05 2.87E+05 Sr-90 1.02E+06 4.48E+05 Cs-137 1.52E+06 1.23E+06 Eu-152 8.33E+05 6.78E+05 Eu-154 7.71E+05 6.28E+05 Table 10 Operational DCGLs for Soil (OpDCGLS)

LC-FS-TSD-002 Revision 2 Page 17 of 18 ROC Soil OpDCGLS (pCi/g)

Co-60 3.83 Sr-90 1970.45 Cs-137 17.39 Eu-152 8.51 Eu-154 7.89 Table 11 Operational DCGLs for Buried Pipe Scenarios ROC Buried Pipe Group OpDCGLBP (dpm/100 cm2)

Buried Pipe Circulating Water Discharge OpDCGLBP (dpm/100 cm2)

Insitu Excavation Insitu Excavation Co-60 1.20E+06 1.60E+04 4.74E+07 1.63E+04 Sr-90 1.10E+05 8.50E+06 1.62E+05 8.84E+06 Cs-137 3.44E+06 6.81E+04 1.23E+08 6.94E+04 Eu-152 5.12E+07 3.45E+04 9.61E+13 3.51E+04 Eu-154 3.53E+07 3.20E+04 1.87E+17 3.27E+04 Table 12 Operational DCGLs for Buried Pipe (OpDCGLBP)

ROC Buried Pipe Group OpDCGLBP (dpm/100 cm2)

Buried Pipe Circulating Water Discharge OpDCGLBP (dpm/100 cm2)

Co-60 1.57E+04 1.63E+04 Sr-90 1.08E+05 1.58E+05 Cs-137 6.68E+04 6.94E+04 Eu-152 3.44E+04 3.51E+04 Eu-154 3.20E+04 3.27E+04 Table 13 Operational DCGLs for Above Grade Buildings (OpDCGLAGB)

ROC Above Grade Building OpDCGLAGB (dpm/100 cm2)

Co-60 1136 Sr-90 1392 Cs-137 4480 Eu-152 2032

LC-FS-TSD-002 Revision 2 Page 18 of 18 Eu-154 1840

7. References
1. EnergySolutions Techncial Support Document RS-TD-313196-004, Revision 3.
2. U.S. Nuclear Regulatory Commission, NUREG-1575, Revision 1, "Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM)," August 2000. August 2000.
3. US Nuclear Regulatory Commission, NUREG 1757, Vol. 1, Rev. 2, Consolidated Decommissioning Guidance, Final Report, September 2006.