ML18347A570

From kanterella
Jump to navigation Jump to search
Semiannual Radioactive Effluents Report Covering 1/1/1976 - 6/30/1976, with List of Corrected Data for Errors
ML18347A570
Person / Time
Site: Palisades 
Issue date: 09/02/1976
From: Bixel D
Consumers Power Co
To: James Keppler
NRC/RGN-III
References
Download: ML18347A570 (5)


Text

(

~~L/;{;12/

.//

/~f&_Jl General Offices: 21~ West Michigan Avenue, Jackson, Michigan 49201

  • Area Code 517 788-0550 September 2, 1976 Mr James G. Keppler Office of Inspection & Enf'orcement Region III US Nuclear Regulatory Connni~sion

-799 Roosevelt Road Glen Ellyn, IL 60l37 DOCKET 50-255, LICENSE DPR PALISADES PL.ANT -

SEMIANNUAL RADIOACTIVE EFFLUENT REPORT Attached are sU1I1I11ary tables of the effluents released for the period of January l, 1976 through June 30, 1976.

These tables are in the format asso-ciated with Appendix B of Regulatory Guide 1.21 and constitute our semiannual radioactiv~ effluent report *

. J:t ll;as.been br:ought t.o our.att,ention that a.number o~.er.ro~s.,e.xi:st.iP data pr.e-vi ously reported.

The corrected data are given below.

Errors in Table VIIIC of the Ninth Semiannual (Jan l, 1975 Through June 30, 1975) and the First Annual Report (Jan l, 1975 Through Dec 31, 1975)

Shipment 750148 750228 750468 750488

  • Reported 6,66E-02 l.36E+Ol o.42 o.8 Total Curies Correct Value 6.60E-02 l.33E+Ol.

4.2E-02 l.15E-Ol Error on Page VIII-4 of the Ninth Semiannual Report (Jan 1, 1975 Through June 30, 1975)

Total Curies Reported Correct Value Total Solid Waste Shipped 114 126

  • J

_S_E_P~7_19_7_6~~~-"-~~~--~

/

/

' /*

/2 c

(

Error on Page VIII-12 of the First Annual Report (Jan 1, 1975 Through Dec 31, 1975)

Total Curies Reported Correct Value Total Solid Waste Shipped 221 We regret any inconvenience these errors may have caused.

Davfd A. Bixel

-Assistant Nuclear Licensing Administrator

. CC:

Office of Inspection & Enforcement Div of Reactor Inspection.Programs (25)

C

~..

j f

. ~

/'n

.. \\

a c "'-.

    • /

TAB IE Coi11111i!i!r11 POiier Ccmpany Pali11ade11 Nuclear Plant,_Docket No 50*255 Liquid lladioa.ctive Effluents

  • laundry System Dratn1 I

!ls!!!

~ Febr!!!!Z Match.

let Quarter A2r11

~

Jwie 2n4 QUarter S!ir:-Mimth Total

('

I Total lla4ioactivit~ Relea1ed

  • 1.73s-01 l,B4m.01 1,52E-01 5.osm.oi 6.02E-o2 7~3;z;.02 5.83s-01

~

I... Curie*

1.33E-02 L

( Inclui:!ing Trit11111 l>

Vollmle ot Waste Discharged,. **

titeri i,5jE+-05 l,06E+05 9,52E+o4 3.54iM5 7,44t+o4 e.92~

i..04E+05 4~58E+05 I

Ave~e Coocentration of Waste l

  • Prior to Release JJ.Ci/ml

~.13E-03 1,74E-03

. 1,59>>.03 1,44E-03 8,09m.o4

. 4,55g.o4 M6E-o4 l.27Eo03 I I Vol~e ot Circulati!lg Discharge Water.

L1ter11 **

l.15E+-10.

l,08Etl0 l.15E+10 3.3BE+-l0 1.05E+-10 1~14E+-10

.9.81E+09 3.17E+-10 6.55E+l0 I

Avera8e Concentration Released *.

J.i.Ci/ml l.51E-08

. l.'IOE-08 2.32E.oe l,5QE-08 5,73E-09 l,l'(E-09 2,32E-09 8,9C)E-09 91 Percent-of Technical Specifications.......

1>

6,02E~l 6.BlE+<>l 5.2i.E+-01 6.0lEi-Oi 2.29E+-Ol 4.67E+-OO 9,26E+-OO 3.56Etol I1otopes Curies co-57, l.4oE-05 2.23E-04 l.96°E-04 4.m:-04 3,lOE-05

.~-~-----

3.lOE-05 4.64s-04

  • Cr-51..

4,05E-03 l,BlE-02

Co-56.

2.95E-02 8,64&-02 7.29E-02 l,89z.01 8,79:g.03 4,02E-03 1,2BE-02 2,02E-Ol Mn-54..........

3.61E-03 3,Srg.03 3.39E-03 l.09E-02

  • 1,oBE-03 5,92:g.o4 l.67E-03 l,25E-02 Zn-65..

l.54E-o4 l,54E-o4 6.'IOE-05 6.'IOE-05 2.21E-o4 I-131.

3,06E-03 6.20E-05 3.13E-03" 3.13E-03 llb-95.

. 2.76E-04 i.32E-03 l,46E-03 3.06E-03 7.94E-o4

  • e' j

~

3.* 00E-05 8.24E-04 3,89g.03 Cs-i34

  • 6.62&-03 6,org.03 4~74E-03.

l.74E-03 4.26E-03 6.83&-04 4.94&-03 2.24E-02

. ca-136

  • 1.34&-02 1.17&-02

. 8,23E-03 3,33g.02 l.34E-02 1,52E-03.

l.49E-02 4.82E-02 Xe-133

Zz--95

  • 9.9ClE-05 9,04E-o4 1.29>>.04 l.73E-03 4.63E-04 4,30E-05 5.06E-04 2.24E-03 ee-141
  • 3.50E-05 5,4oE.05 8.9C)E-05 8.9C)E-05

~-J.lio l.24E-04 l,24E-04 l.24E-o4 Fe-59..

4.03E-04 7.33E-04 4.28E-04 l.56E-03 4,9C)E-05 4.9ClE-05 l.61E-03 co-60.

7.74E-03 l.04&-02 l,05E-02 2.87E-02 4.llE-03 l.68E-03 5.78E-OJ 3,45E-02 Ni-63.

l.43E-02 l.43E-02 l~43E-02 Net Unidentified Beta.

l,lBE-02 4, 73E-03 l,65E-02 3.UE-o4 3.llE-04 J..68E-02 H-3..........

7,76E-02 3,!)4&-02 3,3,:S..02 l,5QE-Ol 2.66E-02 3.64E-03 3.02E-02 l.BlE-Ol Percent or Totel Identified..

93.2

> 95 795

>95

> 95

>95

>95

> 95 l

  • J
'j

.!l!!ili Totei Radioactivity Released (E>ccept Tritium, Dissolved Noble ClaBes &Alpha) *......

Curies Volume of Waste Disc:.'larged *****....

Liters ATerage Concentration of Waste Prior to Release (Eiccept Tritium, Dissolved Noble Gases & Alplia). JlCi/ml Volume of Circula,ting Dis::harge Water *....

verage Concen~ration Released (E>ccept Tritium, Dissolved Gases & Alpha.

  • verage Tritium CC!lcentration Released 54 c... 137 t Unidentified Beta t o~ Total Id.,nti1'1ed (Eiccept Tritium, Dissolved Gase~ & Alphs) * * * *,, *,,,
  • Liters
  • JJCi/ml

'{.

Curies

  • )lCi/ml Curie a*
  • ~

I TABLE Consulii~rs """POWer Company Palisades Nuclea~ Plant, Docket 50-255 Liquid Radioactive E.'f'i'luehts - Modified Liquid Waste System January Febru!!!Y March lat Quarter AJ.!ril 4.37E-o4 3.83E-03 6.4oE-'b4 4.91E-03 2.95E-05 7,42E+-05 7.24E+05 4,88Eia5 l.95E!-06 4.26E+-05 5.89E-07 5,29~06 l.31E-b6 2.52E-06 6,92E-08 l.l5E+l0 l,08E+l0 l,l5E+io 3.38E+l0

t.05E+l0 3.BoE-11 3.55E-10 5.57E-ll l.45E-10 2.BlE-12
  • 5.30E-02 3.17E+OO 2.70E+OO 2.69Eioo 8,55E+OQ l.16E-02 2.76E-07 2,5QE-07 2.34E-ci7 2.53E-07 l,lOE-09 2.4oE-o4 2.4oE-04 l.31E-o4 1.3lE-o4 1,60E-05 1.6oE-05 88.6 o.o o.o o.o
  • b ti@..

M~

June 2nd QUerter Sill:-M::inth Total

~.42E-o4 l.50E-05 3.87E-o4 5,29s-03 l.99E+<i6 l.39E!-06 3.BlE!-06 5._76!+-06 l,72E-07 l.08E-08 l,02E-07 9.18E-07 l.14E+l0 9,81E+-09 3.17E+l0 6.55E+l0 3'.00E-11 l.53E-l:>

l,??F~ll 8.07E-ll e****

4.12E-03 2.93E-02 2,22E-02 l.27E-CY,!

4.65E-02 B.60E+OO l,95E-09 l.29E-09 l.47E-09 l.31E-07 2.4oz.o4 1.31E-oll l.60E-05 l.50Eo05 0,0 0,0 o.o

('J Tot'a1 Noble Gases

  • Total Halogens. * * * * * * * * *
  • Total Particulates (Beta & GBlllDB)
  • Percent ot Applicable Limits Noble Gases*.*

Halogens *****

Particulates ***

Isotopic Releases Noble Gases -

Xe-133 *******************

!'.r-85 **********

mens.

I-133.............

Particulates MD-54.

Co-58.

Co-60.

ez-,.51 *...................

Cs-137 Co-57 *.......

Ce-141, Net Unidentitied Beta,

Alpha,..................

i.85B-02 1.46lll-03 4.90E-06 l.09E-05 3.16E-06 l,4oFJ.02 3.o4FJ.06 9,60E-07 2.lOFJ.o6' 3,38E-o6 1.57E-05 3.30E-07

. 2.55E-07

-"-~-..

..""'-"-*--** ~'._.

---,.~----.. '".,....,.,


~~-

l.78E-t>4 2.02E-02 2,09z.o6 3.6oE-06 2.<>~05 6,64g.:66 6.64E-o6 2.19E-o6 1.97E-tl5 3,55E-05 6.54E-06 2.56E-06

4. 79E-b6 7,95:g.06 3,9iE-06 9,:µ.E-06 l,24E-'05 l,4oE-02 5.13E-06 8,17E-06 9.60E-07 2,lOE-06 7,63E-06 2.67E-05 6,04E-06 l,29E-05 2.61E-07 B.46E-07 2.62E-07 2.77E-07

-*~..-................-.

4.50E-02 5.69B-o6 l,47E-05 J,48E-05 2.23E-06 4,42E-06 9.10E-06 l,JOE-05 4.67E-06 4.67E-06 2.48E-06 2,14E-05 5.:,;iE-07 1.1or..06 1.32B+OO' 2.0l.E-02

. 1.42E-02 5.58&-05 B.99E-02 8,49FJ.o4 2.02.B-02 3.48B-05 l.llE-05 4,46E-05 2.lOE-05 1.4oE-02 l.28E-05 9.60E-07 2.lOE-06 4,BlE-05 l.94E-06

  • 1

! ~

0

~ _._........ ~........ ~**