01 THE OHIO STATE UNIVERSITY College of E:1iglneering Nuclear Reactor Lab,,ratory 1298 Kinnec1i' Road Columbus, OH 43212 September 18, 2018 U.S. Nuclear Regulatory Commission Document Control Desk Attn: Xiaosong Yin One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738

Subject:

Annual Report for The Ohio State University Research Reactor, License R-75, Docket 50-150 reactor@osu.edu reactor.osu.edu Please find enclosed the annual report for The Ohio State University Research Reactor, Docket No. 50-150. This report is being submitted as required by our Technical Specifications, Section 6.6.1. If you have questions on the content of this report, please contact Mr. Andrew Kauffman, Senior Associate Director of the,.Nuclear Reactor Laboratory, at 614-688-8220 or..

kauffman.9@osu.edu.

1 I declare under penalty of perjury that the foregoing is true and correct.

Executed on 18-Sep-2018.

~

Sincerely,

-~~~-

~mend Cao, Director OSU Nuclear Reactor Lab The Ohio State University (License R-75, Docket 50-150)

I.

OSURR Annual Report THE OHIO STATE UNIVERSITY RESEARCH REACTOR ANNUAL REPORT FOR FY 2017/2018 SEPTEMBER 2018 Page 1 of 10 Sep 2018

Introduction As stated in The Ohio State University Research Reactor (OSURR) Technical Specifications Section 6.6.1, Operating Reports, an annual report shall be made to the NRG by September 30 of each year. This report is to include the following seven information items:

1. A narrative summary of operating experience (including experiments performed) and of changes in facility design, performance characteristics, and operating procedures related to reactor safety occurring during the reporting period
2. A tabulation showing the energy generated by the reactor (in kilowatt hours) and the number of hours the reactor was in use *
3. The results of safety related maintenance and inspections and the reasons for corrective maintenance of.safety-related items
4. A table of unscheduled shutdowns and inadvertent scrams, including their reasons and the corrective actions taken
5. A summary of the safety analyses performed in connection with changes to the facility or procedures, which affect reactor safety, and performance of tests or experiments carried out under the conditions of 10 CFR 50.59
6. A summary of the nature and amount of radioactive gaseous, liquids, and solid effluents released or discharged to the environs beyond the effective control of the licensee as measured or calculated at or prior to the point of such release or discharge
7. A summary of radiation exposures received by facility personnel and visitors, including the dates and times of significant exposures These seven information items are discussed below for the period July 1, 2017 through June 30, 2018, except as noted for exposure records.
1. Summary of Operating Experience and Changes 1.A. Experiments Performed The OSURR engages in a wide range of research endeavors, including neutron activation analysis (NM), radiation-damage studies, neutron and radiation sensitive detector evaluation, isotope production, neutron transmission testing, neutron depth profiling, and neutron imaging.

Much of the NM work performed at the OSURR is for geological and material science samples, but NM is used for other purposes, such as industrial and biological. Most radiation-damage studies performed at the OSURR are for electronic and fiber-optic components, but studies have been performed for other materials. The OSURR has been involved in the development of a number of potential types of neutron and radiation detectors, including fiber-optic based systems, and it regularly tests fission chambers for use in commercial power reactors by characterizing their response to known neutron flux. Isotope production has typically been performed for medical research, but sources have been created for other uses, including testing of radiation-sensitive detectors. Neutron transmission testing has been used to verify boron loading in borated aluminum, and neutron depth profiling has been used for battery-technology studies. In addition, other experiments are performed at the OSURR, such as reactivity worth measurements, spectrum characterizations using flux-wire activation and analysis, and physics experiments such as neutron irradiation of fullerenes.

OSURR Annual Report Page 2 of 10 Sep 2018

The OSURR also provides a variety of instructional services ranging from general tours to individual and group laboratory sessions and research projects structured to student and faculty interests. Nuclear engineering and physics classes throughout Ohio have utilized the OSURR for the following basic experiments:

a. approach to critical (using banked control rods rather than fuel loading)
b. control rod calibration by rod drop, positive period, and subcritical multiplication
c. temperature coefficient measurements
d. radiological surveys When the OSURR is used to introduce students, faculty or other experimenters to nuclear research, the following are typically done:
a. discuss nuclear reactions and radiological safety
b. operate the reactor at 10kW-100kW
c. have the individuals observe control room operations
d. complete a tour and demonstrate irradiation techniques Neutron activation experiments are performed for students ranging from high school to graduate school.

The reactor utilization for July 1, 2017 through June 30, 2018 is summarized in the following reports. Please note that the utilization hours listed below only reflect actual reactor operating time. The list does not include hours spent on tasks supporting this reactor utilization.

OSURR Annual Report Page 3 of 10 Sep 2018

The Ohio State University Nuclear Reactor Lab Reactor Utilization Report:

July 1 - December 31, 2017 User (Name)

Description Hours 1

AFIT (lab class)

Radiation effects on electronic devices 2.6 AFIT (Cruz)

Radiation effects on optical fibers 9.0 American Ceramic Tech.

Transmission & life testing of shielding 12.4 products Reuter-Stokes, Inc.

Fission chamber QA testing 35.8 NDSU (Lepper)

NAA of geology samples 1.5 NIST (Downing)

Radiation effects on Lexan 1.0 NRL staff Calibrations, maintenance, facility 13.1 2

characterization ORNL (Ezell / Mulligan)

High Temperature Fission Chamber 17.2 Orrvilon, Inc.

Neutron transmission testing 36.7 OSU EGE Radiation effects on gallium oxide 3.5 2

OSU NE (Blue / Wilson)

Radiation effects on optical fibers 25.3 2

OSU NE (Cao)

Beam experiments (NOP, imaging, detector 41.8 testing)

OSU NE 4506 Lab class experiments*

2.2 U. of Chicago (Collar)

Detector calibration 5.0 U. of Cinci (Glover I Spitz)

Silica discs 4.4 Various3 Tours 14.4 Total:

225.9 Notes:

1.

Utilization hours reflect actual reactor operating time. This list does not include hours spent on tasks supporting this reactor utilization (pre-start and post-shutdown checkout, experiment planning and setup, etc.).

2.

Value listed does not include reactor utilization when run as a secondary user concurrent with a primary user.

3.

Tours provided to support the OSU NE program (student ANS, prospective grad students, NE 4505, and NE 4506), other OSU academic programs (International Studies 4701 ), and Thermo Scientific.

OSURR Annual Report Page 4 of 10 Sep 2018

The Ohio State University Nuclear Reactor Lab Reactor Utilization Report:

January 1 - June 30, 2018 User (Name)

Description Hours 1

AFIT (Hogsed)

Transmission testing of boron nitride (BN) nanotubes 2.8 AFIT (Cruz)

Radiation testing of optical fibers 1.1 AFIT (Ford)

Detector test in beam facility 0.9 Kansas St. U. (Edgar)

Doping of hexagonal boron nitride (hBN) 3.2 Luna Innovations, Inc.

Radiation testing of fiber-based sensors 32.4 NDSU (Lepper)

NAA of geology samples 2.0 NRL staff Calibrations, maintenance, operator requalification 10.2 2

NRL staff Sc-46 production 4.9 NRL staff Beam facility testing 8.7 Orrvilon, Inc.

Neutron transmission testing 56.0 Reuter-Stokes, Inc.

Fission chamber testing 29:5 OSU ECE (Ringel)

Radiation effects on gallium oxide 3.2 OSU NE (Cao)

Beam experiments (NOP, imaging, detector testing) 16.0 2

OSU NE 5742 Lab class experiments 2.4 OSU NE 6726 Lab class experiments 13.9 U. of Chicago (Collar)

Detector calibration 6.9 West Point (Kaminsky)

Activation of glass beads 2.4 Various3 Tours 34.5 Total:

231.0 Notes:

1.

Utilization hours reflect actual reactor operating time. This list does not include hours spent on tasks supporting this reactor utilization (pre-start and post-shutdown checkout, experiment planning and setup, etc.).

2.

Value listed does not include reactor utilization when run as a secondary user concurrent with a primary user.

3.

Tours provided to support the OSU NE program (MAE advisory committee and NE 4505), other OSU academic programs (Earth Science 2210, Environmental Science 2155, Physics 1251), and officially recognized groups (Chemistry club, MSE club, Engineers for a Sustainable World, Navy ROTC). In addition, tours were provided for Bluffton H.S., the Columbus Power and Energy Society, the Edison Welding lnstitute's Ma2JIC program, the Ohio EMA, and the Ohio Energy Project (Ohio H.S. STEM teachers).

OSURR Annual Report Page 5 of 10 Sep 2018

1.B. Changes in Facility Design There were no facility design changes that required a change to the Technical Specifications.

1 O CFR 50.59 changes are described in Section 5.A of this report.

1.C. Changes in Performance Characteristics There have been no changes in performance characteristics related to reactor safety in the last year.

1.D. Changes in Operating Procedures There were no changes in operating procedures related to reactor safety in the last year.

10 CFR 50.59 changes are described in Section 5.8 of this report.

2. Energy Generated and Hours of Use Kilowatt-Hours of Operation: 69719.9 kW-hr Hours of Utilization: 456.9 hr
3. Safety Related Maintenance None.
4. Unscheduled Shutdowns From July 1, 2017 to June 30, 2018, there were two unplanned shutdowns. These are summarized below.

Reason Corrective Action Period Safety scram when signal cable bumped (1)

None required Period Safety scram when rack bumped (2)

None required

5. Changes in Facility and Procedures in Accordance with 10 CFR 50.59 5.A. Facility Modifications During the period July 1, 2017 to June 30, 2018, two OSURR Modification Requests were completed:
1) Beam Port 2 Beam Facility Control-Box Upgrades
2) Linear Channel CIC Replacement plus Replacement of Spacer Rings on UIC #2 All of the modifications screened out of 10 CFR 50.59 evaluation per Procedure AP-16, 50. 59 Screening and Evaluation.

OSURR Annual Report Page 6 of 10 Sep 2018

5.8. Procedure changes The following is a list of procedure changes made under 10 CFR 50.59 from July 1, 2017 to June 30, 2018, in accordance with Administrative Procedure AP-06, Format for Writing, Revising, and Approving Procedures.

Procedure Procedure Revision Number Title Date OM-15 Process System Checks 08/22/17 OM-16 Power Calibration 08/21/17 OM-17 Beam Port 2 Beam Facility Use 05/29/18 RS-03 Calibrating Gaseous Effluent Monitor 08/03/17 RS-08 NRL Smear Survey 08/15/17 IM-01 Scram Checks 08/04/17 IM-12 Reactor Instrumentation Calibration/ Checks 08/15/17 All of the procedure changes screened out of 10 CFR 50.59 evaluation per Procedure AP-16,

50. 59 Screening and Evaluation.
6. Radioactive Effluents 6.A. Gaseous Effluent The only gaseous effluent releases made from operation of the OSURR are Ar-41 releases from activation of the naturally occurring noble gas Ar-40. For the period July 1 - December 31, 2017, Ar-41 releases measured 1.36% of the annual average concentration limit. From January 1 -

June 30, 2018, releases measured 1.22% of the annual average concentration limit. In accordance with the requirements of 10 CFR 20.1101 (d), the COMPLY code was run using the total Ar-41 release for the period July 1, 2017 -June 30, 2018 of 135.0 mCi. Using level 2 in the code, the effective dose equivalent rate at the facility fence was computed to be 0.09 mrem/yr.

This is well below the 1 O mrem/yr constraint specified in the regulation.

Any other releases were reported under the university's license with the state of Ohio.

6.8. Liquid Releases Hot sink releases are recorded and reported through the OSU Office of Radiation Safety. No releases were made from operation of the OSURR, and other releases were reported under the university's license with the state of Ohio.

6.C. Solid Releases No releases of solid radioactive material were made to the uncontrolled environment.

OSURR Annual Report Page 7 of 10 Sep 2018

7. Radiation Exposures Since the firm that maintains records for The Ohio State University keeps a year-to-date record, it is simpler to report radiation exposure records by the nearest completed calendar year.

Therefore, dosimetry badge exposures in this report are for the period January 1, 2017 to December 31, 2017. Sixteen individuals were monitored as radiation workers during this period, and the measured dose equivalent values are tabulated below in mrem.

Individual Dose Equivalent (mrem)

DOE LOE SOE, WB SOE, ME Visitors 0

0 0

N/A Staff member #1 38 46 73 64 Staff member #2 77 80 86 375 Staff member #3 42 44 56 28 Staff member #4 44 44 98 47 Staff member #5 43 43 43 67 Staff member #6 9

9 9

Staff member #7 15 15 15 77 Staff member #8 0

0 0

Student #1 2

2 2

Student #2 4

4 4

0 Student #3 97 97 97 185 Student #4 4

4 4

40 Student #5 3

3 3

0 Student #6 3

3 3

0 Visiting Scientist #1 4

4 4

Visiting Scientist #2 3

3 3

OSURR Annual Report Page 8 of 10 Sep 2018

COMPLY: Vl. 7.

40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH 7/2/2018 2:34 THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE - Vl.7.

COMPLY: Vl. 7.

OSURR Annual Report Prepared by:

The Ohio State University Nuclear Reactor Lab 1298 Kinnear Road Andrew Kauffman 614-688-8220 Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460 Page 9 of 10 7/2/2018 2:34 Sep 2018

OSURR FY2018 SCREENING LEVEL 2 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

AR-41 1.350E-01 Release height 10 meters.

Building height 11 meters.

The source and receptor are not on the same building.

Distance from the source to the receptor is 15 meters.

Building width 25 meters.

Default mean wind speed used (2.0 m/sec).

NOTES:

Input parameters outside the "normal" range:

None.

RESULTS:

Effective dose equivalent:

      • Comply at level 2.

9.3E-02 mrem/yr.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

                    • END OF COMPLIANCE REPORT**********

OSURR Annual Report Page 10 of 10 Sep 2018