ML18192A952
Text
Oconee Nuclear Station UFSAR Appendix 10A. Tables Appendix 10A. Tables
Oconee Nuclear Station UFSAR Table 10-1 (Page 1 of 1)
(31 DEC 2000)
Table 10-1. Condensate/Feedwater Reserves (each unit)
Source Max. Capacity Upper Surge Tank A 36,000 gallons/unit Upper Surge Tank B 36,000 gallons/unit Condenser Hotwell 142,000 gallons/unit Condensate Storage Tank 30,000 gallons/unit Makeup Demineralizers 450 gallons/minute (Total Capacity)
(225 gallons/minute in service and 225 gallons/minute in reserve)
Note:
- 1. Additional condensate feedwater may also be provided from condensate sources associated with the other units, if these sources are available and operable.
Oconee Nuclear Station UFSAR Table 10-2 (Page 1 of 1)
(31 DEC 2009)
Table 10-2. Parameter Indication Location for EFW System Parameter Local Control Room Turbine Driven EFW Pump Suction Pressure X
Motor Driven EFW Pump A Suction Pressure X
Motor Driven EFW Pump B Suction Pressure X
Turbine Driven EFW Pump Discharge Pressure X
X Motor Driven EFW Pump A Discharge Pressure X
Motor Driven EFW Pump B Discharge Pressure X
Turbine Driven EFW Pump Recirculation Flow X
Turbine Driven EFW Pump Seal Injection Water Pressure X
Motor Driven EFW Pump A Discharge Flow X
Motor Driven EFW Pump B Discharge Flow X
Emergency-EFW Supply to Steam Generator A Flow X
Startup Header EFW Supply to Steam Generator A Flow X
Emergency-EFW Supply to Steam Generator B Flow X
Startup Header EFW Supply to Steam Generator B Flow X
Steam Generator A Level X
Steam Generator B Level X
Motor Driven EFW Pumps A&B Recirculation Flow X
Motor Driven EFW Pump Suction Strainer Differential Pressure X
X FDW-315 Nitrogen Bottle A Pressure X
X FDW-315 Nitrogen Bottle B Pressure X
X FDW-316 Nitrogen Bottle A Pressure X
X FDW-316 Nitrogen Bottle B Pressure X
X FDW-315 Nitrogen Bottle A Regulator Outlet Pressure X
FDW-315 Nitrogen Bottle B Regulator Outlet Pressure X
FDW-316 Nitrogen Bottle A Regulator Outlet Pressure X
FDW-316 Nitrogen Bottle B Regulator Outlet Pressure X