TS 4.17-1 4.17 SHOCK SUPPRESSORS (SNUBBERS)

Applicability Applies to all hydraulic and mechanical shock suppressors (snubbers) which are required to protect the reactor coolant system and safety related systems.

Objective To specify the minimum frequency and type of surveillance to be applied to the hydraulic and mechanical snubbers in Tables 4.17-1 (Unit 1) and 4.17-2 (Unit 2).

Specification Each snubber shall be demonstrated operable by performance of the following augmented inservice inspection program and the requirements of Specification 4.0.

A.

Visual Inspections

1.

The first inservice visual inspection of snubbers shall be performed after four months but within 10 months of commencing power operation and shall include all snubbers listed in Tables 4.17-1 and 4.17-2. If less than two (2) snubbers are found inoperable during the first inservice visual inspection, the second inservice visual inspection shall be performed 12 months

+/- 25% from the date of the first inspection.

Otherwise, sub-quent visual inspections shall be performed in accordance with the following schedule:

-i*2oi130272* *a:i* - ------ --

-- -~- ---

PDR ADOC~ 05o86g~o p

PDR


~----

-~

B.

2.

e e

TS 4.17-2 No. Inoperable Snubbers Subsequent Visual per Inspection Period Inspection Period*

0 18 months +/- 25%

1 12 months +/- 25%

2 6 months +/- 25%

3,4 124 days +/- 25%

5,6,7 62 days +/- 25%

8 or more 31 days +/- 25%

The snubbers may be categorized into two groups:

Those access-ible and those inaccessible during reactor operation.

Each group may be inspected independently in accordance with the above schedule.

Visual Inspection Acceptance Criteria

1.

Visual inspections shall verify:

a.

That there are no visible indications of damage or impaired operablity,

b.

Attachments to the foundation or supporting structure are secure, and

c.

In those locations where snubber movement can be manually induced without disconnecting the snubber, that the snubber has freedom of movement and is not frozen up.

  • The inspection interval shall not be lengthened more than one step at a time.

I..

e e

TS 4.17-3

2.

Snubbers which appear inoperable as a result of visual inspectio~s may be determined operable for the purpose of establishing the next visual inspection interval, providing that the cause of the rejection is clearly established and remedied for that particular snubber and for other snubbers that may be generically susceptible and the affected snubber is functionally tested in the as found condition and determined operable per Specification 4.17-D or 4.17-E, as applicable.

3.

When the fluid port of a hydraulic snubb~r is found to be uncovered, the snubber shall be determined inoperable and cannot be determined operable via functional testing for the purpose of establishing the next visual inspection interval. All snubbers connected to an inoperable common hydraulic fluid reservior shall be counted as inoperable snubbers.

C.

Functional Tests

1.

At least once per 18 months during shutdown, a representative sample of 10% of the total of each type of snubber used in the plant shall be functionally tested either in place or in a bench test.

2.

For each snubber that does not meet the functional acceptance

3.
  • criteria of Specifications 4.17-D or 4.17-E, an additional 10%

of that type of snubber shall be functionally tested.

The representative sample selected for functiqnal testing shall include the various configurations, operating environments and the range of size and capacity of snubbers.

TS 4.17-4

4.

At least 25% of the snubbers in the representativ~ sample shall include snubbers from the following three categories:

a.

The first snubber away from each reactor vessel nozzle

b.

Snubbers within 5 feet of heavy equipment (valve; pump, turbine, motor, etc.)

c.

Snubbers within 10 feet of the discharge from a safety relief valve.

5.

Snubbers identified in Tables 4.17-1 and 4.17-2 as "Especially Difficult to Remove" or in "High Radiation Zones During Shutdown" shall also be included in the representative sample.*

6.

In addit~on to the regular sample, snubbers which failed the previous functional test shall be retested during the next test period. If a spare snubber has been installed in place of a failed snubber, then both the failed snubber (if it is repaired and installed in another position) and the spare snubber shall be retested.

Test results of these snubbers may not be included for the re-sampling.

7.

Snubbers of rated capacity greater than 50,000 lb. need not be functionally tested.

  • Permanent or other exemptions from functional testing for individual snubbers in these categories may be granted by the Commission only if a justifiable basis for exemption is presented and/or snubber life destructive testing was performed to qualify snubber operability for all design conditions at either the completion of their fabrication or at subsequent date.

,~....... **~.* "

    • i.,.

~

  • D.
l.

e TS 4.17-5

8.

If any snubber selected for functional testing either fails to lockup or fails to move, i.e., frozen in place, the cause will be evaluated and *if caused by manufacturer or design deficiency all snubbers of the same design subject to the same defect shall be I

functionally te~ted.

This testing requirement shall be indepen-dent of the requirement$. stated above for snubbers not meeting the functional test acceptance criteria.

9.

For the snubber(s) found inoperable, an engineering evaluation shall be perfQrmed on the components which are supported by snubber(s).

The purpose of this engineering evaluation shall be to determine if the components supported by the snubber(s) were adversely affected by the inoperability of the snubber(s) in order to ensure that the supported component remains capable of meeting the designed service.

Hydraulic Snubbers Functional Test Acceptance Criteria

1.

The hydraulic snubber functional test shall verify that:

a.

Activity (restraining action) is achieved within the specified range of velocity or acceleration in both tension and compression.

b.

Snubber bleed, or release rate, where required, is within the specified range in compression and tension.

For snubbers specifically required to not displace under continuous load, the ability_ of the snubber to withstand load without displace-ment shall be verified.

e e

TS 4.17-6 E.

Mechanical Snubbers Functional Test Acceptance Criteria F.

1.

The mechanical snubbers functional test shall verify that:

a.

The force that initiates free movement of the snubber rod in either tension or compression is less than the specified maximum drag force.

Drag force shall not have increased more than 50% since the last functional test.

b.

Activity (restraining action) is achieved within the specified range of velocity in both tension and compression.

c.

Snubber release rate, where required, is within the specified range in compression and tension.

For snubbers specifically required not to displace under continuous load, the ability of the snubber to withstand load without displacement shall be verified.

Snubber Service Life Monitoring

1.

A record of the service life of each snubber, the date at which the designated service life commences and the installation and maintenance records on which the designated service life is based shall be maintained as required by Specification 6.5.B.9.

2.

Concurrent with the first inservice visual inspection and at least once per 18 months thereafter, the installation and maintenance records for each snubber listed in Tables

4. 17-1 and 4.11-2* shall be reviewed to verify that the indicated service life has not been exceeded or will not be exceeded prior to the next scheduled snubber service life review.

If the indicated service life will be

1 Bases e

e TS 4.17-7 exceeded prior to the next scheduled snubber service life review, the snubber service life shall be reevaluated or the snubber shall be replaced or reconditioned so as to extend its service life beyond the date of the next scheduled service life review.

This reevaluation, replacement or reconditioning shall be indicated in the records.

All snubbers are required operable to ensure that the structural integri-ty of the reactor coolant system and all other safety-related systems is maintained during and following a seismic or other event initiating dynamic loads.

Snubbers excluded from this inspection program are those installed on nonsafety-related systems and then only if their failure or failure of the system on which they are installed would have no adverse effect on any safety-related system.

The visual inspection frequency is based upon maintainin'.g a constant level of snubber protection to systems.

Therefore, the required inspec-tion interval varies inversely with the observed snubber failures and is determined by the number of inoperable snubbers found during an inspec-tion.

Inspections performed before that interval has elapsed may be used as a new reference point to determine the next inspection.

However, the results of such early inspections performe~ before the original required time interval has elapsed (nominal time less 25%) may not be used to lengthen the required inspection interval.

Any inspection whose results require a shorter *inspection interval will override the previous schedule.

.I.

TS 4.17-8 When the cause of the rejection of a snubber is clearly established and remedied for that snubber and for any other snubbers that may be gener-ically susceptible, and verified by inservice functional testing, that snubber may be exempted from being counted as inoperable.

Generically susceptible snubbers are those which are of a specific make or model and have the same design features directly related to rejection of the snubber by visual inspection, or are similarly located or exposed to the same environmental conditions such as temperature, radiation, and vibra-tion.

When a snubber is found inoperable, an engineering evaluation is per-formed, in addition to the determination of the snubber mode of failure, in order to determine if any safety-related component or system has been adversely affected by the inoperability of the snubber.

The engineering evaluation shall determine whether or not the snubber mode of failure has imparted a significant effect or degradation on the supported component or system.

To provide assurance of snubber functional relaibility, a representative sample of the installed snubbers will be functionally tested during plant shutdowns at 18 month intervals.

Functional testing is to be in accordance with ASME Section XI 1980ed. Subsection IWF.

Observed failures of these sample snubbers shall require functional testing of additional units.

Hydraulic snubbers and mechanical snubbers may each be treated as a different entity for the above surveillance programs.

  • -. -~*.~

e TS 4.17-9 The service life of a snubber is evaluated via manufacturer input and information through consideration of the snubber service conditions and associated installation and maintenance records (newly installed snubber, seal replaced, spring replaced, in high radiation area, in high tempera-ture area, etc **** ).

The requirement to monitor the snubber service life is included to ensure that the snubbers periodically undergo a performance evaluation in view of their age and operating conditions.

These records will provide statistical bases for future consideration of snubber service life.

The requirements for the maintenance of records and the snubber service life review are not intended to affect plant operation.

e Accessibility Category A= Accessible I= Inaccessible Radiation Category TS 4.17-10 LEGEND H = High radiation area only during periods of reactor operation.

In acceptable radiation work area during period of reactor shutdown.

N = Acceptable radiation work area during periods of reactor operation

/

and shutdown.

Removal Category D = Expecially difficult to remove R = Can be removed

  • Snubbers may be added to and deleted from safety related systems without prior License Amendment to Tables 4.17-1 and 4.17-2 provided that a revision to Tables 4.17-1 and 4.17-2 included in the next License Amendment request~
    • Modifications to the "Radiation Category" column due to changes in high radiation areas may be made without prior License Amendment provided that a revision to Tables 4.17-1, 4.17-2, 4.17-3 and 4.17-4 is included with the next License Amendment request.
  • ~

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 1-SHP-HSS-27 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-28 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-29 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-30 6"

Safeguards A

N D

e Main Steam System 1-SHP-HSS-31 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-32 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-33A 6"

Safeguards A

N D

I:

Main Steam System 1-SHP-HSS-33B 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-34A 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-34B 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-35A 6"

Safeguards A

N D

Main Steam System 1-SHP-HSS-35B 6"

Safeguards A

N D

e Main Steam System 1-SHP-HSS-36 1 1/2" Safeguards A

N R

Main Steam System 1-SHP-HSS-37 1 1/2" Safeguards A

N R

~

en Main Steam System 1-SHP-HSS-38 1 1/2" Safeguards A

N R

+:"'

1/2" Main Steam System 1-SHP-HSS-39 1

Safeguards A

N R

-...J I.....

Main -Steam System 1-SHP-MSS-50 PSA-1 Safeguards A

N D

Main Steam System 1-SHP-MSS-51A PSA-35 Safeguards A

N D

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 1-SHP-MSS-5 lB PSA-35 Safeguards A

N.

D Main Steam System 1-SHP-MSS-52A PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-52B PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-53A PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-53B PSA-35 Safeguards A

N D

Main Steam System 1-SHP-MSS-54A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-54B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-55A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-55B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-56A PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-56B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-57 PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-58 PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-59A PSA-3 Safeguards A

N D

~

en Main Steam System l-SHP-MSS-59B PSA-3 Safeguards A

N D

~

Main Steam System 1-SHP-MSS-60A PSA-3 Safeguards A

N D

I.....

N Main Steam System 1-SHP-MSS-60B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-MSS-61A PSA-3 Safeguards A

N D

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 1-SHP-MSS-61B PSA-3 Safeguards A

N D

Main Steam System 1-SHP-HSS-lA 5"

Machinery Room /11 A

N D

Main Steam System 1-SHP-HSS-lB 5"

Machinery Room Ill A

N D

Main Steam System 1-SHP-HSS-14A 5"

Machinery Room Ill A

N D e Main Steam System 1-SHP-HSS-14B 5"

Machinery Room Ill A

N D

Main Steam System 1-SHP-HSS-21 4"

Machinery Room Ill A

N D

Main Steam System l-SHP-HSS-22 4"

Machinery Room Ill A

N D

Main Steam System 1-SHP-HSS-23 4"

Machinery Room Ill A

N D

Main Steam System l-SHP-HSS-24 4"

Machinery Room III A

N D

Main Steam System 1-SHP-HSS-25 4 II Machinery Room fl 1 A

N D

Main Steam System 1-SHP-HSS-26 4"

Machinery Room Ill A

N D

Main Steam System 1-SHP-HSS-2A 5"

Containment-67' level I

H D De Main Steam System 1-SHP-HSS-2B 5"

Containment-67' level I

H Ma.in Steam System 1-SHP-HSS-3A 3 1/4" Containment-67' level I

H R

t-3 en Main 1/4" Containment-67' Steam System l-SHP-HSS-3B 3

level I

H R

~

1-SHP-HSS-4A 1/4" Containment-67' Main Steam System 3

level I

H R

I w

Main Steam 1-SHP-HSS-4B 3 1/4" Containment-67' level System I

H R

Main Steam System 1-SHP-HSS-5A 2 1/2" Containment-67' level I

H R

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SYSTEM DESIGNATION SIZE LOCATION Main Steam System 1-SHP-HSS-SB 2 1/2" Containment-67' level Main Steam System 1-SHP-HSS-6A 2 1/2" Containment-67' level Main Steam System 1-SHP-HSS-6B 2 1/2" Containment-67' leve Main Steam System 1-SHP-HSS-7 8"

Containment Operating Main Steam System l-SHP-HSS-8 8"

Containment Operating Main Steam System l-SHP.;..HSS-9 1011 Containment Operating Main Steam System l-SHP-HSS-10 10" Containment Operating Main Steam System 1-SHP-HSS-11 8"

Containment Operating Main Steam System l-SHP-HSS-:12 8"

Containment Operating Main Steam System 1-SRP-HSS-13A 4"

Containment Operating RADIATION ACCESSIBILITY CATEGORY I

H I

H I

H level I H

level I H

level I H

level I H

level I H

level I H

level I H

REMOVAL CATEGORY R

R R

D D

D

  • D D

D D

~

I.....

~

(

. :I

  • I

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Feed System l-WFPD-HSS-18 1 1/2" Safeguards A

N R

Main Feed System 1-WFPD-HSS-20 3 1/4" Safeguards A

N R

Main Feed System 1-WFPD-HSS-21A 2 1/2 11 Safeguards A

N R

Main Feed System l-WFPD-HSS-21B 2 1/2" Safeguards A

N Main Feed System.

l-WFPD-HSS-22 3 1/4" Safeguards A

N R

Main Feed System l-WFPD-HSS-1 2 1/2" Containment Operating Level I

H R

Main Feed System l-WFPD-HSS-2 2 1/2" Containment Operating Level I

H R

Main Feed System l-WFPD-HSS-3 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-4 2 1/2" Containment Operating Level I

H R

Main Feed System l-WFPD-HSS-6 2 1/2" Containment Operating Level I

H R

Main Feed. System 1-WFPD-HSS-8 2 1/2"

  • containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-9 2 1/2" Containment Operating Level I

H R

Main Feed System 1-WFPD-HSS-10 2 1/2" Containment Operating Level I

H Main Feed System l-WFPD-HSS-11 2 1/2 11 Containment Operating Level I

H R

t-,1 Main Feed System l-WFPD-HSS-12 2 1/2" Containment Operating Level I

H R

ti)

.i:-,.

Main Feed System 1-WFPD-HSS-13 2 l/2'i Containment Operating Level I

H R.....

Main Feed System 1-WFPD-HSS-14 2 1/2" Containment Operating Level I

H R Vt Main Feed System l-WFPD-Hss:..15 2 1/2" Containment Operating Level I

H R

I

I; I'::

, SYSTEM Main Feed System Main Feed System

-~ *** *,J * *.** -- **

DESIGNATION 1-WFPD-HSS-16 1-WFPD-HSS-17 TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SIZE 2 1/2" 2 1/2" LOCATION ACCESSIBILITY Containment Operating Level I

Containment Operating Level I

RADIATION CATEGORY H

H REMOVAL CATEGOR~

R R

I a,

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA

,J RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Aux. Feed System 1-WAPD-HSS-140 1 1/2" Containment Operating Level I

H R

Aux. Feed System l-WAPD-HSS-141A 1 1/2" Containment Operating Level I

H R

Aux. Feed System l-WAPD-HSS-141B 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-142 1 1/2" Containment Operating Level I

H R -

Aux. Feed System l-WAPD-HSS-143A 1 1/211 Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-143B 1 1/2" Containment Operating Level I

H R

Aux. Feed System 1-WAPD-HSS-145 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-HSS-146 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-HSS-147 1 1/2" Safeguards A

N R

Aux. Feed System 1-WAPD-HSS-148 1 1/2" Safeguards A

N R

Aux. Feed System l-WAPD-HSS-149 1 1/2" Safeguards A

N R

e I

.1

, I t..;J en

~

I-'

I I-'

SYSTEM DESIGNATION Component Cooling System l-CC-HSS-60A Component Cooling System l-CC-HSS-65 Component Cooling System l-CC-HSS-330 Component Cooling System l-CC-HSS-331 Component Cooling System l-CC-HSS-332A Component Cooling System l-CC-HSS-332B Component Cooling System l-CC-HSS-340A Component Cooling System 1-CC-HSS-340B Component Cooling System l-CC-HSS-341 TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SIZE LOCATION ACCESSIBILITY 2 1/2" Aux. Basement A

2 1/2" Atix. Basement A

2 1/2" Aux. Basement A

2 1/2" Aux. Basement A

2 1/2" Aux. Basement A

2 1/2" Aux. Basement A

2 1/2" Aux. Basement A

2 1/211 Aux. Basement A

2 1/2" Aux. Basement A

RADIATION CATEGORY N

N N

N N

N N

N N

REMOVAL CATEGORY R

R R

R R

R R

R R

e

-...J I.....

00

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY i!

I Lo-head Safety Injection 1-Sl-HSS-19A 511 Containment basement-I H

D A Accumulator Lo-head Safety Injection 1-Sl-HSS-19B 5 II Containment basement-I H

D A Accumulator Lo-head Safety Injection 1-Sl-HSS-20 811 Containment basement-I H

D e A Accumulator Lo-head Safety Injection 1-Sl-HSS-22A 5 II Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-Sl-HSS-22B 511 Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-Sl-HSS-23 811 Containment basement-I H

D B Accumulator Lo-head Safety Injection 1-Sl-HSS-25 811 Containment basement-I H

D C Accumulator Lo-head Safety Injection

- l-Sl-HSS-26 811 Containment basement-I H

D C Accumulator Lo-head Safety Injection l-Sl-HSS-84 1 1/211 Safeguards basement A

N R -

Lo-head Safety Injection l-Sl-HSS-85 1 1/211 Safeguards basement A

N R

1-3 Lo-head Safety Injection 1-Sl-HSS-100 1 1/2" Safeguards Valve Pit A

N R

en

.p,,.

Lo-head Safety Injection

  • l-Sl-HSS-101 1 1/2" Safeguards Valve Pit A

N R

-..J I....

Lo-head Safety Injection l-Sl-HSS-21A 411 Containment basement I

H D

\\0 Lo-head Safety Injection l-Sl-HSS-21B 411 Containment basement I

H D

.]

l Lo-head Lo-head Lo-head Lo-head Lo-head SYSTEM Safety Injection Safety Injection Safety Injection Safety Injection Safety Injection

' \\

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA DESIGNATION SIZE LOCATION 1-Sl-HSS-24A 4"

Containment Basement 1-Sl-HSS-24B 4 II Containment Basement 1-Sl-HSS-27A 4"

Containment Basement 1-S1-HSS-27B 4"

Containment Basement 1-Sl-HSS-28 1.1/2 11 Containment Basement RADIATION

- REMOVAL ACCESSIBILITY CATEGORY CATEGORY I

H D

I H

D I

H D

I H

D -

I H

R e

1-i en

.p.

-..J I

N 0

SYSTEM DESIGNATION Recir. Spray System 1-RS-HSS-107 Recir. Spray System 1-RS-HSS-106 Recir. Spray System 1-RS-HSS-105 Recir. Spray System 1-RS-MSS-115A Recirc. Spray ~ystem 1-RS-MSS-115B Recirc. Spray System 1-RS-MSS-116A Recirc. Spray System*

l-RS-MSS-116B TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SIZE LOCATION ACCESSIBILITY 3 1/4" Safeguards Valve Pit A

1 1/2" Containment 90' etevation I 1 1/2" Containment 3' level I

PSA-3 Containment 10 '- level I

PSA-3 Containment 10' level I

PSA-3 Containment 10' level I

PSA-3 Containment 10' level I

CATEGORY N

H H

H H

H H

CATEGORY R

D R

D D

D D

-...J I

I; 1,.

~. *~*****. ~. -,.,._,....... "" '

SYSTEM Chemical Volume &

Control System Chemical Volume &

Control System DESIGNATION 1-CH-HSS-301 1-CH-HSS-302 TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SIZE LOCATION 1 1/2" Aux. Building 1 1/2" Aux. Building.

ACCESSIBILITY A

A RADIATION CATEGORY N

N REMOVAL CATEGORY R

R e

.,:r.:

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 1-RC-HSS-110 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-111 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System l-RC-HSS-112 1 1/211 Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-113 1 1/211 Pressurizer Cubicle I

H R -

Reactor Coolant System 1-RC-HSS-114 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-115 1 1/2 11 Pressurizer Cubicle I

H R

Reactor Coolant System 1-RC-HSS-122 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1"".'RC-HSS-123 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-124 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-125 6"

Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-HSS-138 12 11 A S/G Upper restraint I

H D

\\

casting

  • Reactor Coolant System l-RC-HSS-139 12" A S/G Upper restraint I

H D

casting e

Reactor Coolant System 1-RC-HSS-140 12" A S/G Upper restraint

'I H

D casting Reactor Coolant System 1-RC-HSS-141 12" A S/G Upper restraint I

H D

casting 1-3 Reactor Coolant System 1-RC-HSS-142 12" B S/G Upper restraint I

H D

en casting

.i:-.

Reactor Coolant System l-RC-HSS-143 1211 B S/G Upper restraint I

H D

I-'

-..J casting I

I\\.>

Reactor Coolant System 1-RC-HSS-144 12" B S/G Upper restraint I

H D

w casting Reactor Coolant System 1-RC-HSS-145 12" B S/G Upper restraint I

H D

casting

1 TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 1-RC-HSS-146 12" C S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-147 12" C S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-148 12" C S/G Upper restraint I

H D

casting Reactor Coolant System 1-RC-HSS-149 12" C S/G Upper restraint I

H D e casting Reactor Coolant Sys_tem 1-RC-HSS-172 4 1/2" A S/G I

H D

Reactor Coolant System 1-RC-HSS-173 4 1/2" A S/G I

H D

Reactor Coolant System l-RC-HSS-174

  • 4 1/211 A S/G I

H D

Reactor Coolant System l-RC-HSS-175 4 1/2" A S/G I

H D

Reactor Coolant System l-RC-HSS-176-4 1/2" B S/G I

H D

Reactor Coolant System 1-RC-HSS-177 4 1/2" B S/G I

H D

Reactor Coolant System 1-RC-HSS-178 4 1/2 11 B S/G I

H D

Reactor Coolant System 1-RC-HSS-179 4 1/2" B S/G I

H D e Reactor Coolant System 1-RC-HSS-180 4 1/2" C S/G I

H D

Reactor Coolant System 1-RC-HSS-181 4 1/2" C S/G I

H D

~

1/2" S/G en Reactor Coolant System 1-RC-HSS-182 4

C I

H D

.p..

f--1 Reactor Coolant System 1-RC-HSS-183 4 1/2" C S/G I

H D

-..J I

.p.

Reactor Coolant System 1-RC-MSS-llSA PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-llSB PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-116A PSA-10 Pressurizer Cubicle I

H D

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 1-RC-MSS-116B PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-117 A PSA-10 Pressurizer Cubicle I

H D

  • i

'i Reactor Coolant System 1-RC-MSS-ll 7B PSA-10 Pressurizer Cubicle I

H D

Reactor Coolant System 1-RC-MSS-218 PSA-1 Pressurizer Cubicle I

H-D e Reactor Coolant System 1-RC-MSS-219 PSA-1/2 Pressurizer Cubicle

  • I H

D Reactor Coolant System 1-RC-MSS-22.0 PSA-1/2 Pressurizer Cubicle I

H D

Reactor C-oolant System l-RC-MSS-221 PSA-3 Outside Pressurizer I

H D

Cubicle Reactor Coolant System 1-RC-MSS-222 PSA-3 Outside B S/G Cubicle I

H D

Reactor Coolant System 1-RC-HSS-126 4"

A RCP I

H D

i Reactor Coolant System 1-RC-HSS-127 4"

A RCP I

H D

Reactor Coolant System l-RC-HSS-128 4"

A RCP I

H D

Reactor Coolant System 1-RC-HSS-129 4"

A RCP I

H D

Reactor Coolant System 1-RC-HSS-130 4"

.. B RCP I

H D e Reactor Coolant System 1-RC-HSS-131 4"

B RCP I

H D

1-'3 Reactor Coolant System 1-RC-HSS-132 4"

B RCP I

H D

tr.I

~

Coolant 1-RC-HSS-133 4"

B RCP I

H.

D Reactor System

-.J I

~

Reactor Coolant System l-RC-HSS-134 4"

C RCP I

H D

\\J1

~

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System l-RC-HSS-135 4"

C RCP I

H D

Reactor Coolant System 1-RC-HSS-136 4 II C RCP I

H D

Reactor Coolant System l-RC-HSS-137 4"

C RCP I

H D

Reactor Coolant System 1-RC-HSS-150 12" A S/G Lower Support ring I

H D e Reactor Coolant System 1-RC...:.HSS-151 12 11 A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-152 12" A S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-153 12 11 A.S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-154 12

B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-155 1211 B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-156 12" B S/G Lower Support ring I

H D

Reactor Coolant System l-RC-HSS-157 12" B S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-158 12 11 C S/G Lower Support ring I

H D

Reactor Coolant System 1-RC-HSS-159 1211 C S/G Lower Support ring I

H D e Reactor Coolant System 1-RC-HSS-160 12"*

C S/G Lower Support ring I

H D

1-3 en 12 11 S/G Reactor Coolant System 1-RC-HSS-161 C

Lower Support ring I

H D

~

I-'

Reactor Coolant System 1-RC-HSS-162 12" A RCP Lower Support ring I

H D

-.J I

N O'I 12" Reactor Coolant System 1-RC-HSS-163 A RCP Lower Support ring I

H D

Reactor Coolant System l-RC-HSS-166 12" B RCP Lower Support ring I

H D

t.

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 1-RC-HSS-167 12" B RCP Lower Support beam I

H D

Reactor Coolant System 1-RC-HSS-170 12" C RCP Lower Support beam I

H D

Reactor Coolant System 1-RC-HSS-171 12" C RCP Lower Support beam I

H D

J.

l 1."

Reactor Coolant System 1-PS-MSS-lA PSA 1 A S/G elevation 55' I

H D e Reactor Coolant System 1-PS-MSS-2A PSA-1/4 A S/G elevation 55' I

H D

Reactor Coolant System 1-P.S-MSS-lB PSA-1 B S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-2B PSA-1/4 B S/G elevation 55 1 I

H D

{

Reactor Coolant System 1-PS-MSS-lC PSA-1 C S/G elevation 55' I

H D

Reactor Coolant System 1-PS-MSS-2C PSA=l/4 C S/G elevation 55 1 I

H D

Reactor Coolant System 1-RC-HSS-164 1 1/211 A Loop room-Elevation 20 1 I

H R

Reactor Coolant System 1-RC-HSS-165 1 1/2" A Loop room-Elevation 20 1 I

H R

Reactor Coolant System 1-RC-HSS-168 1 1/2" B Loop room-Elevation 20 1 I

H R

Reactor Coolant System 1-RC-HSS-169 1 1/211 B Loop room-Elevation 20 1 I

H R e Reactor Coolant System 1-RC-HSS.,-116 1 1/211 C Loop room-Elevation 20' I

H R

C Loop room-Elevation 20 1 I

H R

~

Reactor Coolant System 1-PS-MSS-llA PSA-10 A Loop room I

H D

I N

Reactor Coolant System 1-PS-MSS-23B

  • psA-1/4 B Loop room-Elevation 12' I

H D

Reactor Coolant System 1-PS-MSS-lOC PSA-1/4 C Loop room Elevation 12' I

H D

~~--~-

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SYSTEM DESIGNATION SIZE LOCATION Reactor Coolant System 1-PS-MSS-12C PSA-1/4 C Loop room El-13' Reactor Coolant System 1-PS-MSS-14C PSA-1/4 C Loop room El-13'

~:

Reactor Coolant System 1-RC-HSS-102 1 1/2" Containment Basement Reactor Coolant System 1-RC-HSS-103 1 1/2 11 Containment. Basement Reactor Coolant System 1-RC-HSS-104 1 1/2" Containment Basement Reactor Coolant System 1-RC-HSS-105 1 1/2" Containment Basement Reactor Coolant System 1-RC-HSS-106 1 1/2" Containment Basement Reactor Coolant System 1-RC-HSS-107 1 1/2" Containment Basement Reactor Coolant System l-RC-HSS-108 1 1/2" Containment Basement RADIATION ACCESSIBILITY CATEGORY I

H I

H I

H I

H I

H I

H I

H I

H I

H REMOVAL CATEGORY D

D R

R R

R R

R R

e I

N 00

'I

1

I i'

~

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Make-up System l-WCMU-HSS-100 1 1/2" Safeguards A

N R

l

N R

Service*Water System l-SW-HSS,-2 PSA-1/4 Machinery Room #3 A

N D

Emergency Diesel 1-EE-HSS-01 1 1/2" Ill EDG Exhaust A

N R -

Emergency Diesel 1-EE-HSS-03 1 1/2" 113 EDG Exhaust A

N R

S/G Blowdown 1-WGCB-HSS-10 1 1/2" Aux. Basement A

N R

S/G Blowdown l-WGCB-MSS-23 PSA--3 Aux. Basement A

N D

S/G Blowdown l-WGCB-MSS-11 PSA-1/2 A Loop room-El. 13/6" I

H D

S/G Blowdown 1-WGCB-MSS-12 PSA-1/2 A loop room-El. 7'8" I

H D

S/G Blowdown l-WGCB-MSS-13 PSA-1/2 A loop room-El. 8'3" I

H D

S/G Blowdown l-WGCB-MSS-14A PSA-1/2 A loop room-El. 6' I

H D

S/G Blowdown 1-WGCB-MSS-14B PSA-1/2 A loop room-El. 6' I

H

  • D

.S/G Blowdown 1-WGCB-MSS-lSA PSA-1/2 A S/G Cubicle I

H D -

S/G Blowdown 1-WGCB-MSS-lSB PSA-1/2 A S/G Cubicle I

H D

~

S/G Blowdown 1-WGCB-MSS-16 PSA-1/2 A S/G Cubicle I

H D

00

~

S/G Blowdown l-WGCB-MSS-17A PSA-1/2 loop room-El. 13' I

B H

D

-.J I*

N S/G Blowdown 1-WGCB-MSS-17B PSA-1/2 B loop room-El. 13' I

H D

\\0 S/G Blowdown l-WGCB-MSS-18A PSA-1/2 B loop room-El. 7' I

H D

S/G Blowdown 1-WGCB-MSS-18B PSA-1/2 B loop room-El. 7 I I

H D

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA SYSTEM DESIGNATION SIZE LOCATION S/G Blowdown 1-WGCB-MSS-19 PSA-1/2 B loop room-El. 10' S/G Blowdown 1-WGCB-MSS-100 PSA-1/2 B loop room-El. 15' S/G Blowdown l-WGCB-MSS-10 PSA-1/2 C loop room-El. 12' S/G Blowdown 1-WGCB-MSS-20A PSA-1/2 C loop room El. 6' S/G Blowdown l-WGCB-MSS-20B PSA-1/2 C loop room-El. 6' S/G Blowdown 1-WGCB-MSS-21 PSA-1/2 C loop room-El. 12' S/G Blowdown 1-WGCB-HSS-02 2 1/2 C loop room S/G Blowdown 1-WGCB-HSS-03 2 1/2 C loop room RADIATION ACCESSIBILITY CATEGORY I

H I

H

-I H

I H

I H

I H

I H

I H

REMOVAL CATEGORY D

D D

D D

D R

R I w 0

!i

~

TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSI~ILITY CATEGORY CATEGORY Residual Heat Removal Sys.

1-RH-HSS-103 2 1/2" A loop room-El. 3' I

H R

Residual Heat Removal Sys.

1-RH-HSS-104 2 1/2" A loop room-El. 3' I

H R

Residual Heat Removal Sys.

1-RH-MSS-120A PSA-3 A loop room I

H D

Residual Heat Removal Sys.

1-RH-MSS-120B PSA-3 A loop room I

H D e Residual Heat Removal Sys.*

l-RH-HSS-1 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-2 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-3 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-4 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-5 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-6 2 1/2" RHR Flat I

H R

Residual-}Jeat Removal Sys.

1-RH-HSS-7 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-8 2 1/2 11 RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-9 1 1/2" RHR Flat I

H R e Residual Heat Removal Sys.

1-RH-HSS-10 1 1/2" RHR Flat I

H R

1-'l 1/2" en Residual Heat Removal Sys.

1-RH-HSS-11 1

RHR Flat I

H R

~

Residual Heat Removal Sys.

1-RH-HSS-12 1 1/2" RHR Flat I

H R

-.J I w Residual Heat Removal Sys.

1-RH-HSS-13 1 1/2 11

H R

Residual Heat Removal Sys.

1-RH-HSS-14 1 1/2" RHR Flat I

H R

j TABLE 4.17-1 UNIT NO. 1 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Residual Heat Removal Sys.

1-RH-HSS-15 r 1/2" RHR Flat I

H R

l Residual Heat Removal Sys.

1-RH-HSS-19 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-20 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-105 1 1/2" RHR Flat I

H R e Residual Heat Removal 1-RH-HSS-21 1/2" Sys.

1 RHR Flat I

H R

Residual Heat Removal Sys.

1:...RH-HSS-22 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-23 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-24 1 1/2" RHR Flat I

H R

Residual Hea:t Removal Sys.

1-RH-HSS-25 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-100 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-lOlA 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-lOlB 1 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

1-RH-HSS-102 1 1/2" RHR Flat I

H R e Residual Heat Removal Sys.

1-RH-HSS-26 1 1/2" RHR Flat I

H R

H Residual Heat Removal Sys.

1-RH-HSS-27 1 1/2" RHR Flat I

H en R

~

1/2" Residual Heat Removal Sys.

1-RH-HSS-28 1

RHR Flat I

H R

I w N

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL

!1 SYSTEM

, DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 2-SHP-HSS-lA 5"

Machinery Room 112 A

N D

Main Steam System 2-SHP-HSS-lB 511 Machinery Room 112 A

N D

Main Steam System 2-SHP-HSS-14A 5"

Machinery Room 112 A

N D

e Main Steam System 2-SHP-HSS-14B 511 Machinery Room 112 A

N D

, I Main Steam System 2-SHP-HSS-15 4 II Safeguards A

N D

Main Steam System 2-SHP-HSS-16 411 Safeguards A

N D

Main Steam System 2-SHP-HSS-17 411 Safeguards A

N D

Main Steam System 2-SHP-HSS-18 4 II Safeguards A

N D

Main Steam System 2-SHP-HSS-19 411 Safeguards A

N-D Main Steam System 2-SHP-HSS-20 411 Safeguards A

N D

Main Steam System 2-SHP-HSS-21 4"

Safeguards A

N D

e Main Steam System 2-SHP-HSS-22 4"

Safeguards A

N D

Main Steam System 2-SHP-HSS-23 4"

Safeguards A

N D

1-3 Main Steam System 2-SHP-HSS-24 4 II Safeguards A

N D

en

.i::-.

Main Steam System 2-SHP-HSS-25 4"

Safeguards A

N D

I w

Main Steam System 2-SHP-HSS-26 4"

Safeguards A

N D

w Main Steam System 2-SHP-HSS-27 6"

Safeguards A

N D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 2-SHP-HSS-28 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-29 6"

Safeguards A

N D

~ J Main Steam System 2-SHP-HSS-30 6'}

Safeguards A

N D

Main Steam System 2-SHP-HSS-31 6"

Safeguards A

N D -

Main Steam System 2-SHP-HSS-32 6"

Safeguards A

N D

Main* Steam System 2-SHP-HSS:-33A 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-33B 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-34A 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-34B 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-35A 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-35B 6"

Safeguards A

N D

Main Steam System 2-SHP-HSS-36A 1 1/2" Safeguards A

N R

Main Steam System 2-SHP-HSS-36B 1 1/2" Safeguards A

N R

Main Steam System 2-SHP-HSS-40 2 1/2" Safeguards A

N R

e Main 2-SHP-HSS-41 2 1/2" Safeguards Steam System A

N R

Main Steam System 2-SHP-HSS-42 2 1/2" Safeguards A

N R

1-3 en Main Steam System 2-SHP-HSS-51 1 1/2

Safeguards A

N R

~

Main Steam System 2-SHP-MSS-1 PSA-3 Safeguards A.

N D

I w

.f!'>

Main Steam System 2-SHP-MSS-2 PSA-3 Safeguards A

N D

Main Steam System 2-SHP-MSS-3 PSA-3 Safeguards A

N D

Main Steam System 2-SHP-MSS-4 PSA-3 Safeguards A

N D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL

-I SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Steam System 2-SHP-MSS-5 PSA-3 Safeguards A

N D

Main' Steam System 2-SHP-MSS-6 PSA-4 Safeguards.

A N

D Main Steam System 2-SHP-HSS-2A 5"

Containment 67' leve I

H D

Main Steam System 2-SHP-HSS-2B 5"

Containment 67' level I

H D -

Main Steam System 2-SHP-HSS-3A 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-3B

3. 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-4A 3 1/2" Containment 55' level I

H R

Main Steam System 2-SHP-HSS-4B 3 1/2" Containment 55' level I

H R

Main Steam System SHP-HSS-5A 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-5B 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-6A 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-6B 2 1/2" Containment Operating level I H

R Main Steam System 2-SHP-HSS-7 6"

Containment Operating level I H

D Main Steam System 2-SHP-HSS-8 6"

Containment Operating level I H

D

~

C/l Main Steam System 2-SHP-HSS-9 10" Containment Operating level I H

D

.J::'-.....

Main Steam System 2-SHP-HSS-10 10" Containment Operating level I H

D I w Vl Main Steam System 2-SHP-HSS-11 8"

Containment Operating level I H

D Main Steam System 2-SHP-HSS-12 8"

Containment Operating level I H

D Main Steam System 2-SHP-HSS-13A 4"

Containment Operating level.I H

D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Main Feed System 2-WFPF-HSS-14 2 1/2" Safeguards A

N R

Main Feed System 2-WFPD-HSS-15 3 1/4" Safeguards A

N R

Main Feed System 2-WFPD-HSS-16 3 1/411 Safeguards A

N R

Main Feed System 2-WFPD-HSS-17 3 1/4" Safeguards A

N R

Main Feed System 2-WFPD-HSS-18 2 1/211 Safeguards A

N D

Main Feed System 2-WFPD-HSS-1 2 1/2" Containment Operating Level I

H R

Main Feed System 2-WFPD-HSS-2 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-3 2 1/211 Containment Operating Level I

H R

Main Feed System 2-WFPD-HSS-4 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-5 2 1/211 Containment Operating Level I

H R

Main Feed System 2-WFPD-HSS-6 2 1/2" Containment Operating Level I H

R Main Feed System 2-WFPD-HSS-7 4 II Containment Operating Level I

H D

Main Feed System 2-WFPD-HSS-8 4"

Containment Operating Level I H

D Main Feed Sys.tern 2-WFPD-HSS-9 4"

Containment Operating Level I

H D

1-,3 Main Feed System 2-WFPD-HSS-10 4"

Containment Operating Level *I H

D Cf)

~

Main Feed System 2-WFPD-HSS-11 2 1/2" Containment Operating Level I

H R

-.J I

c...,

Main Feed System 2-WFPD-HSS-12 2 1/2" Containment Operating Level I

H R

O'i Main Fee'd System 2-WFPD-HSS-13 2 1/2" Containment Operating Level I

H R

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SYSTEM DESIGNATION SIZE LOCATION Aux. Feed System 2-WAPD-HSS-140 1 1/2" Containment Operating Aux. Feed System 2-WAPD-HSS-141 1 1/2" Containment Operating Aux. Feed System 2-WAPD-HSS-142 1 1/2" Containment Operating Aux. Feed System 2-WAPD-HSS-143 1 1/2" Containment Operating Aux. Feed System 2-WAPD-HSS-144 1 1/2" Safeguards Aux. Feed System 2-WAPD-HSS-145A 1 1/2" Safeguards Aux. Feed System 2-WAPD-HSS-145B 1 1/2" Safeguards RADIATION ACCESSIBILITY CATEGORY Level I

H Level I

H Level I

H Level I

H A

N A

N A

N REMOVAL CATEGORY D

D D

D R

R R

e 1-3 en

~

SYSTEM DESIGNATION Compo!1ent Cooling System 2-CC-HSS-356A Component Cooling System 2-CC-HSS-356B Component Cooling System 2-CC-HSS-357 Component Cooling System 2-CC-HSS-358 Component Cooling System 2-CC-HSS-359 TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SIZE LOCATION ACCESSIBILITY

-2 1/2" Aux. Basement A

2 1/2" Aux. Basement A

1 1/2".

RHR Flat I

1 1/2" RHR Flat I

1 1/2" RHR Flat I

RADIATION CATEGORY N

N H

H H

REMOVAL CATEGORY R

R R

R R -

-.J I w CXi

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Recirc. Spray System 2-RS-HSS-101 1 1/2" Containment Basement I

H R

I Recirc. Spray System 2-RS-HSS-102 1 1/2" Containment Basement I

H R

Recirc. Spray System 2-RS-HSS-103 1 1/2" Containment Basement I

H R

1 j

Recirc.

System Spray 2-RS-HSS-104 1 1/2" Containment Basement I

H R

1 *1.

SYSTEM DESIGNATION S/G Blowdown System 2-WGCB-HSS-4A S/G Blowdown System 2-WGCB-HSS-4B S/G Blowdown System 2-WGCB-HSS-7A S/G Blowdown System 2-WGCB-HSS-7B S/G Blowdown System 2-WGCB-HSS-8A S/G Blowdown System 2-WGCB-HSS-8B S/G Blowdown System 2-WGCB:._HSS-01 I'

S/G Blowdown System 2-WGCB-HSS-02 S/G Blowdown System 2-WGCB-HSS-03 S/G Blowdown System 2-WGCB-HSS-5 S/G Blowdown System 2-WGCB-HSS-6A S/G Blowdown System 2-WGCB-HSS-6B TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SIZE LOCATION ACCESSIBILITY 1 1/2" Aux. Building A

1 1/2" Aux. Building A

1 1/2" Aux. Building A

1 1/2" Aux. Building A

1 1/2" Aux. Building A

1 1/2" Aux. Building A

1 1/2" Containment 3rd level I

2 1/2".

B loop room I

2 1/2" C loop room I

1* 1/2" A Cubicle I

1 1/2" A Cubicle I

1 1/2"

. A Cubicle I

RADIATION REMOVAL CATEGORY CATEGORY N

R N

R N

R N

R N

R N

R H

R H

R H

R H

R H

R H

R

c.

e I

.po 0

  • /........ ~...

,* ** ~t-SYSTEM DESIGNATION Charging System 2-CH-HSS-303 Charging System 2-CH-HSS-304 i j.

Charging System 2-CH-HSS-305

' l j

Charging System 2-CH-HSS-306A Charging System 2-CH-HSS-306B Charging System 2-CH-HSS-307 Charging System 2-CH-MSS-1 Charging System 2-CH-MSS-2 Emergency Diesel 2-EE-HSS-01 Emergency Diesel 2-EE-HSS-02 Emergency Diesel 2-EE-HSS-03 Service Water System 2-SW-MSS-l TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SIZE LOCATION 1 1/2" Aux. Building 1 1/2" Aux. Building 1 1/2" Containment Basement t 1/2" Containment Basement 1 1/2" Containment Basement 1 1/2" Containment Basement PSA-3 Containment Basement PSA-3 Containment Basement 1 1/2" 112 EDG Exhaust 1 1/2" 112 EDG Exhaust 1 1/2" 112 EDG.Exhaust PSA-3 Containment Basement RADIATION ACCESSIBILITY CATEGORY A

N A

N I

H I

H I

H I

H I

H I

H A

N A

N A

N I

H REMOVAL CATEGORY R

R R

R R

R D

D R

R R

D

\\.

~

I

~

L SYSTEM Containment Spray System Containment Spray System DESIGNATION 2-CS-HSS-OlA 2-CS-HSS-OlB TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SIZE 2 1/2" 2 1/2" RADIATION REMOVAL LOCATION ACCESSIBILITY CATEGORY CATEGORY Safeguards Valve Pit A

N R

Safeguards Valve Pit A

N R

e I-'

--.J I

.i:,-

N

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Safety Injection System 2-Sl-HSS-100 2 1/2 11 Safeguard-Valve Pit A

N R

t' Safety Injection System 2-Sl-HSS-101 2 1/2" Safeguard-Valve Pit A

N R

Safety Injection System 2-Sl-HSS-103 1 1/2" Safeguard-Valve Pit A

N R

i '

Safety Injection System 2-Sl-HSS-104A 2 1/2" Safeguard-Valve Pit A

N R

e Injection 2-Sl-HSS-104B 1/2" Safeguard-Valve Safety System 2

Pit A

N R

Safety Injection System 2-Sl-HSS-19A 5"

C Accumulator I

H D

Safety Injection System 2-Sl-HSS-19B 5"

C Accumulator I

H D

Safety Injection System 2-Sl-HSS-20 8 II C Accumulator I

H D

Safety Injection System 2-Sl-HSS-21 6"

C Accumulator I

H D

Safety Injection System 2-Sl-HSS-22A 5"

B Accumulator I

H D

Safety Injection System 2-Sl-HSS-22B 5"

B Accumulator I

H D

Safety Injection System 2-Sl-HSS-23 8"

B Accumulator I

H D

Safety Injection System 2-Sl-HSS-25 8"

A Accumulator I

H D

Safety Injection System 2-Sl-HSS-26 8"

A Accumulator I

H D

1-3 en Safety Injection System 2-Sl-HSS-24 6"

B Accumulator I

H D

~

Safety Injection System 2-Sl-HSS-27 6"

A. Accumulator I

H D

I

~

I.,.)

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 2-RC-HSS-100 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-101 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-102 1 1/211 Pressurizer Relief Tank I

H R

Room Reactor Coolant System 2-RC-HSS-103 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-104 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-105 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-106 1 1/2 Pressurizer Relief Tank I

H R

Room Reactor Coolant System 2-RC-HSS-107 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-108 1 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-110 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-112 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-113 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-114 1 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-115 1 1/2" Pressurizer Cubicle I

H R

1-3 Reactor Coolant System 2-RC-HSS-116 1 1/2" Pressurizer Cubicle en I

H R

~

1/2" 1--'

Reactor Coolant System 2-RC-HSS-117 1

Pressurizer Cubicle I

H R

-..J I

~

Reactor Coolant System 2-RC-HSS-118 1 1/2" Pressurizer Cubicle I

~

H R

Reactor Coolant System 2-RC-HSS-119 1 1/2" Pressurizer Cubicle I

H R

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY

,l Reactor Coolant System 2-RC-HSS-122 6"

Pressurizer Upper Support I

H D

.. J Reactor Coolant System 2-RC-HSS-123 6"

Pressurizer Upper Support I

H D

/

l Reactor Coolant System 2-RC-HSS-124 6"

Pressurizer Upper Support I

H D

j Reactor Coolant System 2-RC-HSS-125 6"'

Pressurizer Upper Support I

H D

e i

Reactor Coolant System 2-RC-HSS-126 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-127 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-128 4"

A RCP Upper Holding I

H D

Assembly

)

Reactor Coolant System 2-RC-HSS-129 4"

A RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-130 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-131 4"

B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-132 4 II B RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-133 4"

B RCP Upper Holding I

Ii D

Assembly e

Reactor Coolant System 2-RC-HSS-134 4 II C RCP Upper Holding I

H D

Assembly Reactor Coolant System 2-RC-HSS-135 4"

C RCP Upper Holding I

H D

Assembly

~

Reactor Coolant System 2-RC-HSS-136 4"

C RCP Upper Holding en I

H D

Assembly

~

Reactor Coolant System 2-RC-HSS-137 4"

C RCP Upper Holding I

H D

-..J I

Assembly

~

VI Reactor Coolant System 2-RC-HSS-138 12" A S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-139 1211 A S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-140 12" A S/G Upper restraint I

H D

Casting

-~

TABLE 4*. 17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Reactor Coolant System 2-RC-HSS-141 12" A S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-142 12 11 B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-143 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-144 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-145 12" B S/G Upper restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-146 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-147 12" C S/G Upper Restraint I

H D

Casting Reactor Coolant System 2-RC-HSS-148 12" C S/G Upper Restraint I

H D

r Casting Reactor Coolant System 2-RC-HSS-149 12" C S/G Upper Restraint I*

H D

Casting Reactor Coolant System 2-RC-HSS-150 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-151 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-152 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-153 12" A S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-154 12" B S/G Lower Support Ring I

H D

1-3 Reactor Coolant System 2-RC-HSS-155 12" B S/G Lower Support Ring I

Ul H

D

~

12" S/G Lower I-"'

Reactor Coolant System 2-RC-HSS-156 B

Support Ring I

H D

I

~

Reactor Coolant System 2-RC-HSS-157 12" B S/G Lower Support Ring I

H D

~

Reactor Coolant System 2-RC-HSS-158 12" C S/G Lower Support Ring I

H D

Reactor Coolant System 2-RC-HSS-159 12" C S/G Lower Support Ring I

H D

-'i TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY

.. d,,i Reactor Coolant System 2-RC-HSS-160 12" C S/G Lower Support Ring I

H D

-~

Reactor Coolant System 2-RC-HSS-161 12" C S/G Lower Support Ring I

H D

i Reactor Coolant System 2-RC-HSS-162 12 11 A RCP Lower Support Beam I

H D

Reactor Coolant 2-RC-HSS-163 12" A RCP Lower i

System Support Beam I

H D

.. J

~

Reactor Coolant System 2-RC-HSS-166 12" B RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-167 12 11 B RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-170 12" C RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-171 12" C RCP Lower Support Beam I

H D

Reactor Coolant System 2-RC-HSS-172 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-173 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-174 4 1/2" A S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-175 4 1/2" A S/G Upper Support I

H D -

Reactor Coolant System 2-RC-HSS-176 4 1/2" B S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-177 4 1/2" B S/G Upper Support I

H D

1--'3 1/2" S/G Upper ti)

Reactor Coolant System 2-RC-HSS-178 4

B Support I

H D

~

1/2" I-'

Reactor Coolant System 2-RC-HSS-179 4

B S/G Upper Support I

H D

I

~

Reactor Coolant System 2-RC-HSS-180 4 1/2" C S/G Upper Support I

-...)

H D

Reactor Coolant System 2-RC-HSS-181 4 1/2" C S/G Upper Support I

H D

Reactor Coolant System 2-RC-HSS-182 4 1/2" C S/G Upper Support I

H D

TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY 1/2" C S/G Upper Reactor Coolant System 2-RC-HSS-183 4

Support I

H D

Reactor Coolant System 2-RC-HSS-184 1 1/2" Containment Basement I

H R

1:

Reactor Coolant System 2-RC-HSS-185 2 1/2" Containment Basement I

H R

Reactor Coolant System 2-RC-HSS-186 1 1/2" Pressurizer Cubicle I

H R

Reacto*r Coolant System 2-RC-HSS-187 1 1/2" Pressurizer relief tank I

H R

room Reactor Coolant System 2-RC-HSS-188A 2 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-188B 2 1/2" Pressurizer Cubicle I

H R

Reactor Coolant System 2-RC-HSS-189A 4 II Pressurizer Cubicle I

H D

Reactor Coolant System 2-RC-HSS-189B 4"

Pressurizer Cubicle I

H D

Reactor Coolant System 2-RC-HSS-190 1 1/2" C Loop Room I

H R

Reactor Coolant System 2-RC-MSS-lA PSA-1 A S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-2A PSA-1/4 A S/G Cubicle I

H D

e Reactor Coolant System 2-RC-MSS-14A PSA-1/4 A S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-lB PSA-1 B S/G Cubicle I

H D

~

en Reactor Coolant System 2-RC-MSS-2B PSA-1/4 B S/G Cubicle I

H D

+:-.

1--'

Reactor Coolant System 2-RC-MSS-lSB PSA-1/4 B S/G Cubicle I

H D

-..J I

+:-

PSA-1/4 00 Reactor Coolant System 2-RC-MSS-16B Containment 3rd level I

H D

Reactor Coolant System 2-RC-MSS-lC PSA-1 C S/G Cubicle I

H D

. j TABLE 4.17-2

I

'I UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY i* f Reactor Coolant System 2-RC-MSS-2C PSA-1 C S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-lSC PSA-1/4 C S/G Cubicle I

H D

Reactor Coolant System 2-RC-MSS-1 PSA-3 Containment 2nd level I

H D

. '.I Reactor Coolant System 2-RC-MSS-2 PSA-3 Containment 2nd level I

H D -

Reactor Coolant System 2-RC-MSS-3 PSA-1/2 A Loop Room I

H D

Reactor Coolant System 2-RC-MSS-4 PSA-1/2 B Loop Room I

H D

Reactor Coolant System 2-RC-MSS.,-5 PSA-1 Containment Operating I

H D

level Reactor Coolant System 2-RC-MSS-6 PSA-1 Containment Operating I

H D

level Reactor Coolant System 2-RC-MSS-7 PSA-1 Containment Operating I

H D

level e

I~

1:

\\

  • ' i Ii.

SYSTEM Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual' Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

Residual Heat Removal Sys.

DESIGNATION 2-RH-HSS-l 2-RH-HSS-2 2-RH-HSS-3 2-RH-HSS-4 2-RH-HSS-5 2-RH-HSS-6 2-RH-HSS-7 2-RH-HSS-8 2-RH-HSS-9 2-RH-HSS-10 2-RH-HSS-11 2-RH-HSS-12 2-RH-HSS-13*

2-RH-HSS-14 2-RH-HSS-15 2-RH-HSS-17 2-RH-HSS-18 2-RH-HSS-19 TABLE 4.17-2 UNIT NO. 2 SUPPRESSOR DATA SIZE 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 2 1/2" 2 1/2" 2 1/2 11 LOCATION RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat RHR Flat ACCESSIBILITY I

Below RHR Flat Below RHR Flat Below RHR Flat Below RHR Flat A Loop Room A Loop Room A Loop Room I

I I

I I

I I

I I

I I

I I

I I

I I

RADIATION CATEGORY H

H H

H H

H H

H H

H H

H H

H H

H H

H REMOVAL CATEGORY R

R R

R R

R R

R R

R R

R R

R R

R R

R

(

-..J I

V1 0

I [,

11 TABLE 4.17-2 I

I UNIT NO. 2 SUPPRESSOR DATA p

I I

RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Residual Heat Removal Sys.

2-RH-HSS-20 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-21 1 1/2" RHR Flat I

H R

1 I

Residual Heat Removal Sys.

2-RH-HSS-22 1 1/2 11 RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-25 1 1/2" Below RHR Flat I

H R

e Residual Heat Removal Sys.

2-RH-HSS-26 1 1/2" Below RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-27 1 1/2" Below RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-28 1 1/2" Containment Basement I H

R J

Residual Heat Removal Sys.

2-RH-HSS-29 1 1/2 11 Containment Basement I H.

R 1 *:

Residual Heat Removal Sys.

2-RH-HSS-30 1 1/2" RHR Flat I

H R

i Residual Heat Removal Sys.

2-RH-HSS-31 2 1/2" RHR Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-32 2 1/2" A Loop Room I

H R

Residual Heat Removal Sys.

2-RH-HSS-33A 1 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-33B 1 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-34 1 1/2" RHR Flat I

H R

~

en Residual Heat Removal Sys.

2-RH-HSS-35 2 1/2" RHR Flat I

H R

.J:'-.

Residual Heat Removal Sys.

2-RH-HSS-36A 1 1/2"

  • Containment Basement I H

R

-..J I

V1

/

Residual Heat Removal Sys.

2-RH-HSS-36B 1 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-37 1 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-38 1 1/2" RHR Flat I

H R

f--

TABLE 4.17-2 C

UNIT NO. 2 SUPPRESSOR DATA RADIATION REMOVAL SYSTEM DESIGNATION SIZE LOCATION ACCESSIBILITY CATEGORY CATEGORY Residual Heat Removal Sys.

2-RH-HSS-39 1 1/2" RHR -Flat I

H R

Residual Heat Removal Sys.

2-RH-HSS-40 2 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-101 1 1/2" Containment Basement I H

R Residual Heat Removal Sys.

2-RH-HSS-102 1 1/2" Containment Basement I H

R -

Residual Heat Removal Sys.

2-RH-MSS-1 PSA-1/4 Containment Basement I H

D I

I Residual Heat Removal Sys.

2-RH-MSS*;...2 PSA-3 Containment Basement I H

D I i

~

......-: ***~, ~---

.. - -. ~-

e TS 6.5-2 B.

Records relative to the following items shall be retained for the life of the plant.

1.

Records of changes made to the plant and plant drawings are described in the FSAR pursuant to 10 CFR 50.59.

2.

Records of new and spent fuel inventory and assembly histories.

3.

Records of plant radiation and contamination surveys.

4.

Records of off-site environmental monitoring surveys.

5.

Records of radiation exposure of all plant personnel, and others as required by 10 CFR 20.

6.

Records of radioactivity in liquid and gaseous wastes released to the environment.

7.

Primary records of inservice inspections including, but not limited to radiographs (of welds which are radiographed), photographs of the scope traces for welds which are tested by ultrasonic techniques, and photographs of the surface of those welds inspected by visual or surface examinations.

a; Records of Environmental Qualification which are covered under the provisions of paragraph 6.7 *

. -*...,~.. *--*** ~-,

~-

  • ' -.-~**;*, *..,...,.., ** ~,- <I r

{

,{.

L: __

r I

TS 6.5-3

9.

Records of the service lives of all hydraulic and mechanical snubbers listed on Tables 4.17-1 and 4.17-2 including the date at which the service life commences and associated installation and maintenance records.