05000280/LER-1980-062, Updated LER-80-062/03X-1:on 801019,w/Unit 1 Shutdown & defueled,RM-CC-105 & 106 Alarm Setpoints Found Contrary to Spec.Caused by Decreased Background Radiation Indications. Setpoints Reset to Value Less than Twice Background

From kanterella
(Redirected from ML18139B303)
Jump to navigation Jump to search
Updated LER-80-062/03X-1:on 801019,w/Unit 1 Shutdown & defueled,RM-CC-105 & 106 Alarm Setpoints Found Contrary to Spec.Caused by Decreased Background Radiation Indications. Setpoints Reset to Value Less than Twice Background
ML18139B303
Person / Time
Site: Surry 
Issue date: 05/07/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139B300 List:
References
LER-80-062-03X, LER-80-62-3X, NUDOCS 8105120495
Download: ML18139B303 (2)


LER-1980-062, Updated LER-80-062/03X-1:on 801019,w/Unit 1 Shutdown & defueled,RM-CC-105 & 106 Alarm Setpoints Found Contrary to Spec.Caused by Decreased Background Radiation Indications. Setpoints Reset to Value Less than Twice Background
Event date:
Report date:
2801980062R00 - NRC Website

text

C9:w

. ii CON.,..

[IE]

s CONTROL. Sl.OCK; I 1

~~~ LI@ I o I s I o I o I o I 21 s I o J011 1 o 11 f 9 1 s I o I© I o I s I o I 1 I_ s I 1 10 60 61 OOCKE'l' NUMBER 68 S9
  • EVENT OAT:
  • 74.

75 REPORT OATc::

80

V!:NT 05SC!=l1PT10N ANO P!'IOBABL.E CONSEQUENCES@)

@:IT] I With Unit 1 at cold shutdown and defueled, PT-26.1 showed RM-CC-105, 106 alarm set-

[]JI} I points to be greater than twice background.

This reduces the sensitivity to transients, -This is contrary to Tech. Spec. Table 3,7-5, and is reportable as*per

[§JI]

T.S. 6.6.2.b.(4) ** The health and safety of the public were not affected

[§:J]J. *.--**--... ~' '*,._

  • -~-..

[ill]

r 1

[§J]J' i..... ______.......,....._ ___________________________________________________________________________________________ ~

7 8 9 BO

[]JI}

7 8

SYST!M CQDE

    • CAUSE
CAUSE COMP.

CQDE SUBCOD!

COMPONENT ccce SUBCCDE VALVE suscoae l!J@ lLJ@ !r!NI sjTjRjul@ L!..l 11 12 13 18 19 IM le I@

9 10 u.J@

I.'::\\

LER/FIO LVENTYEAR I-!:) Re?'JRT I 8 t;e-j

  • NUMBER 21 22 20 SEQUENTIAL.

OCCUFIFIENC!*

REPORT REPORT NO.

CCC&

TYPE I o I 6 I 2 I'

  • I,... I I o l 3 I

.LL!

l=i 23 24 26 27 28 29 lO

11 ACTION PU7\\JRE El"F£CT SHUTOOWN t.::\\

ATTACHMENT' Nll'RD-4 PRIME C:CMP; TAKEN. ACTION ON Pl.ANT M~OD HOURS ~ SUBMITTED

. FORM liUB.

SUPll'Uef'I.

LIJ@W@ W W@)

I* o I o I o I o I L!J@).

  • L!J@ LI 3:1 34
  • 3S JS 37 40

,1 Q

43

  • CAUSE CESCRIPTION AND CO'FIFIECTIVE ACTIONS @

REVISION NO. w*

l2 CQMPONENT

  • MANUFACTURER
- 1 V I 1 ! 1 I 5 I@

"47 o::::I]J I With Unit 1 shutdown. and defueled:, background radiation dec~eased -as* shown* by PT-26.1.1 [IJJJ Both !Uf-CC-105 and RM-cc~106 Setpoints were reset to a value less than twice r:cr:iJ background.

OJI!

7 8

9 FACILITY

'30' STATIJS

% POWER OTMe,i STATUS '.::::,,

CiJI] LI@ I O I O ! 0 l@I... ___

.N_/ A_. - - - '

7 a 9 10 12 11 u*

ACTIVITY CONTENT

,Q\\

REl.!AS!C OF REL:ASE.

AMOUNT.OF ACTIVITY~

ITEi Lll@) WI

.. N/A

. I 7

a s 10 11

.w METHODOI'

~

01SCQVEFIY QISCOV!RY CESCRll"1'10N '5, L!J~_I ~I_n_s_erv

___ i_*c_e~I_n_s_p_e_c_t_i_o_n~~~.,....~~~--....il _*

4 q

BO 80 N/A

.LOCATION OF REI.EASE @

I 80 P!:RSONNEI. ex,osuRES

.t.::\\

NUMBER

~TYPE~ OESCRIPTION ~

[DI] I o! o! o!e,llj~--------N/_A __________________ ___,

a 9

11 12 13 PERSONNEi. INJURIES I'.:':\\

NUMBER t:.::'I OESCRll"1'10N'-!;I OIi IO IO IO 1'5i...".....;.*------~N~A=-------------------~

80 a s 11 12

'-OSS OF OR OAMAG! TO FM;IUTY ~_43

'NP!:

OESCRIPTION l:::::,J

.,,~:1~~j:,9*1 *W@...

7 80

'N/A a

9 10 PUBLICITY*

~

RC 5- 0 v

IS$.1JECC,;\\ OESCRlll'TION ~

N U c:

NI.'

CilII L!Jei ____________

N_I_A ___________ ___,

I I I I I I I I I I I I I !

so a !i 10 68 se ao ;;

J. L. Wilson (804) 357-3184

~

...... ---------~-----

UPDAT~EPORT-PREVIOUS REPORT DATED 11~80 ATTACHMENT 1 SURRY POWER STATION, UNIT 1 DOCKET NO:

50-280 REPORT NO:

80-062/03X-1 EVENT DATE:

10-19--80 TITLE OF EVENT:

RM-CC-105/106 SETPOINTS OUT OF SPEC.

1.

DESCRIPTION OF EVENT

With. Unit 1 at cold shutdown and defueled, PT 26.1 showed RM-CC-105/106 alarm setpoints to be greater than twice background.

This,is contrary to Tech. Spec.

Table 3. 7-5 and is reportable as per T. S. 6. 6. 2. b. (4'f;*

2, PROBABLE CONSEQUENCES AND STATUS OF REDUNDA..~ SYSTEMS :

Component cooling ~ter radiation monitors (RM-CC-105/106) provide for the*

automatic closure of CC surge tank vent valve HCV-CC-100.

With the reduced background radiation resulting from Unit 1 defueling, the setpoint of RM-CC-105/106 must be lowered.

The setpoints being less conservative than those required by T.S. does not prevent the fulfillment of the functional requirements of this system.

Therefore the health and safety of the public were not affected.

3.

CAUSE

This-event was due,tb the*decrease in background radiation levels.

4.

IMMEDIATE CORRECTIVE ACTION

Reduce the alarm setpoints to less than twice background by use of procedure CAL-RM-004.

5.

SUBSEQUENT CORRECTIVE ACTION:

None required.

6.

ACTIONS TAKEN TO PREVENT RECURRENCE:

None.

7.

GENERIC IMPLICATIONS:

None.