LER 80-039/03L-0:on 801102,satisfactory Control Room Pressure Envelope Test Could Not Be Established.Caused by Slippage of Clamp Holding Operating Arm of Damper Preventing Full Closure.Arm Adjusted
ML18139A880
Person / Time
Site: Surry  Dominion icon.png
Issue date: 12/02/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139A878 List:
References
LER-80-039-03L-01, LER-80-39-3L-1, NUDOCS 8012050378
Download: ML18139A880 (2)


Text

IN ....... V fl-771

. ~* . LICENSEE EVENT REPORT CONTROL BLOCK: I ~I IG) . (PLEASE PRINT OR TY.LL REQUIRED INFORMATIONI 1 6

[iliJ I V I A I s Ip Is 1 8 9 LICENSEE CODE 12 101 0 I O I - I O I O I O I O I O I..:

14 15 LICENSE NUMBER IO IO 25 1014 Ii Ii Ii 26 LICENSE TYPE I1 I©I I I © 30 57 CAT 58 CON'T 7

oI 1 I 8

~~~~~ ~©I O 15 1° 10 P I 2 I s 60 61 DOCKET NUMBER 11 101 68 69 11 11 oI EVENT DATE 21 s I o 101 74 75 1 I 2 I o I 2 I a Ia REPORT DATE 10 80 EVENT DESCRIPTION ANQ PROBABLE CONSEQUENCES@

Io I2 I j\./ith the Unit at 50 percent reactor power and stable, Operations was unable to estabJisbl I oI3 I a satisfactory Control Room Pressure Envelope Test. The Control Room Emergency J

Lili] Ventilation System is required by T.S.3.19 to be able to maintain a .05 in. pressure

[QJ}] differential*. This is reportable as per T.S.6.6.2.b(2). The health and safety of the public were not affected.

[ill]

[ill]

I oI a I 7 8 9 80 SYSTEM CAUSE CAUSE COMP. "

VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE I~ Is I GI@ L!J LU@ Iv IA IL Iv IE Ix I@ L!.I w@

7 8 9 10 11 12 13 18 19 20 J SEQUENTIAL OCCURRENCE REPORT REVISION

~ LER/RO LVENT YEAR . REPORT NO. CODE TYPE NO.

\:..:.J REPORT NUMBER j s 1 0I l.=J I OI3 I9 I I,.,,I I OI 3 I ~ l=J L.QJ 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN {22) ATTACHMENT NPRD-4 PRIME C.OMP. COMPONENT TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM SUB. SUPPLIER MANUFACTURER

~@~@) L.:J@  !:.J@)

36 I 01 o 1*0 I I L.2J@. ~@) ~@ IX j 9 j9 I 9 I 33 34 35 37 ~ ~ G ~ 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

LiJ..2J I The clamp holding the operating arm of the cfarr.per had slipped and did not allow full*

[III] I closure. The.arm was adjusted to achieve complete closure.

OJI]

7 8 9 80 FACILITY STATUS  % POWER OTHER STATUS

'3o'

\::::J METHOD OF DISCOVERY DISCOVERY DESCRIPTION ~

~

lITIJ W@ I OI 5 l O l@ I....._....a.;N"'-=/A;:...__ _...... r,...*lol.PD.u----------~

  • l.1.J@L.1--loa(.Jp~e=-r!..Ja~ti.Jo~rl,......lo..:Jb..i..s;:z.ie.._r.._v,,_a......

7 8 9 10 12 1"3 44 45 46 80 ACTIVITY CONTENT * ~

w @ u1@.._I RELEASED OF RELEASE AMOUNT OF ACTIVITY~ .LOCATION OF RELEASE

[£TI]

7 8 9 10 . 11

...:;N.:.!.,;/A = = - - - - - - - - ~

44 45 NIA 80 PERSONNEL EXPOSURES ~

NUMBER r:;:;,.. TYPE DESCRIPTION ITEJ ! 0 7 8 9 j O j OJ~@L-.:.:.:N/:..;;.;A:;.__*- - - - - - - - - - - - - - - - - - - - - - '

11 12 13 80 PERSONNEL INJURIES (.;"'.;\

NUMBER DESCRIPTION~

[iliJ 7 8 I O I O I O l@L.____..::N!..:./A.:____ _ _--,-------------,-------------:----1 9 11 12 80 LOSS OF OR DAMA.GE TO FACILITY '4J' TYPE DESCRIPTION ~

~ ~@) N/A 7 8 9 10 80

  • PUBLICITY* ~ ~:7i" NRC USE ONLY ISS.UEDC,;\DESCRIPTION~ 80]. IS1l ff).~ ff'li<../1CJ '°

[iliJ ~eil1....-_____N....;/A....;*-----~-iiJ.l_~_q;_______~. I I I I It I I I I I I I~

7 8 9 1O 68 69 80 ;

0

..1~ L__Nilson_

  • AtTA.CHMENT 1 SURRY POWER STAT10N, UNIT 2 e

DOCKET NO:

1. DESCRIPTION OF EVENT:

Operations was unable to establish a satisfactory control room pressure differential while performing MOP. 21. 3, control room and relay room operational pressure test. Investigation revealed that damper MOV-VS-104B was not fully closed. This is contrary .to Technical Specification 3.19A and is reportable per Technical Specification 6.6.2.B.(2). The MOP was deviated to use this damper and the associated fan, 2-VS-F-41, to verify compliance with Technical Specification 3.19.B~

2. PROBABLE CONSEQUENCES AND STATUS OF REDUNDANT EQUIPMENT:

As shown by the testing of the emergency ventilation system, the air bottles would not have been able to maintain the required pressure differential.

However, the control room and relay room pressure was maintained by the emergency ventilation system (T.S.3.~9.B). The health and safety of the public were not affected.

3, CAUSE:

The clamp holding the damper's operating arm had slipped.

4. IMMEDIATE CORRECTIVE ACTION:

Verified that the control room emergency ventilation system was functional, as required by Technical Specification 3.19.B.

5. SUBSEQUENT CORRECTIVE ACTION:

Adjusted MOV-VS-104B to insure full closure, and subsequently performed a satisfactory Control Room Pressure Test.

6. ACTION TAKEN TO PREVENT RECCURANCE:

None required.

7. GENERIC IMPLICATIONS:

None.