ML18139A878

From kanterella
Jump to navigation Jump to search
Forwards LERs 80-063/01T-0 & 80-039/03L-0
Date released: 12/10/2018 Download: ML18139A878


LER 80-039/03L-0:on 801102,satisfactory Control Room Pressure Envelope Test Could Not Be Established.Caused by Slippage of Clamp Holding Operating Arm of Damper Preventing Full Closure.Arm Adjusted
ML18139A880
Person / Time
Site: Surry 
Issue date: 12/02/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139A880 (2)
LER 80-063/01T-0:on 801119,during Disassembly of Steam Generator a Leveling Pads,Vascomax Cap Screw Was Broken. Cause Unknown.Vascomax Matl Used in Steam Generator Supports Will Be Replaced During Repair Project
ML18139A879
Person / Time
Site: Surry 
Issue date: 12/02/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139A879 (2)
Forwards LERs 80-063/01T-0 & 80-039/03L-0
ML18139A877
Person / Time
Site: Surry 
Issue date: 12/02/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18139A877 (1)