05000280/LER-1980-064-03, /03L-0:on 800916,w/Unit 1 at Cold Shutdown & Unit 2 at 100% Power,Auxiliary Bldg Filter Banks Found to Be Less Efficient than Required.Caused by Settling of Charcoal in Filters.Filters Replaced

From kanterella
(Redirected from ML18139A604)
Jump to navigation Jump to search
/03L-0:on 800916,w/Unit 1 at Cold Shutdown & Unit 2 at 100% Power,Auxiliary Bldg Filter Banks Found to Be Less Efficient than Required.Caused by Settling of Charcoal in Filters.Filters Replaced
ML18139A604
Person / Time
Site: Surry 
Issue date: 10/16/1980
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139A602 List:
References
LER-80-064-03L-01, LER-80-64-3L-1, NUDOCS 8010200506
Download: ML18139A604 (2)


LER-1980-064, /03L-0:on 800916,w/Unit 1 at Cold Shutdown & Unit 2 at 100% Power,Auxiliary Bldg Filter Banks Found to Be Less Efficient than Required.Caused by Settling of Charcoal in Filters.Filters Replaced
Event date:
Report date:
2801980064R03 - NRC Website

text

.

r JRC:: FORM,366' 7.77 l S. NUCLEAR REGULATORY COMMISSiON LICENSEE EVENT REPORT CONTROL BLOCK: ~'~...._-'"-~-----'~----~lG) 1 o

(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

~

l v f ~1t~st~;o~ I liJ0\\s ol o I - Io

ON'T

~

B

c;:~~~ ~010 15 IO I 01 012 I 8) 0 )G)I O I 9 I 1 I 6) 8 I O 1011 IO* 11 I 6 \\ 8 IO 10 60 61 DOCKET NUMBE?.

68 69 EVENT DATE 74 75 RE?ORT DATE BO EVENT DESCRIPTION AND PROBABLE CONSEQUENCES*@

I With Unit 1 at cold shutdown and Unit 2 at 100% power, the Auxiliary Building filter

~

banks_ were found to be less efficient th.an reguired by T.S.-4.12.B.

~

The air passing through these filters is continously monitored along with periodic

~

sampling with portable monitors, therefore the health and safety of the public were not\\

DI]

7 B

9 affected.

This event is reportable per T.S.-6.6.2.bC.2).

SYSTEM CODE

CAUSE

CAUSE CODE SUBCODE COMPONENT CODE COMP.

suacooE VALVE SUBCOOE Is IC I@ LU@ L!J@)

FJ rJ L I T I E I R I e ~@) ~@

9 10 11

,12 13 1B 1S 20 SEQUENTIAL OCCUR REN CE Q

LER/RO c-VENT YE!>.R REPORT NO.

CODE

'0 P.EPoRT Is Io I I I I o I 6 I 4 I I / I I o I 3 I W

NUMBER 21 22 23 24 26 27 28 29 30 REFORT 7Y~E l::::J

n ACTION FUTLiRE El'FECT SHUTDOWN r::;::;.,

ATTACHMENT N?R~

TAKEN ACTION ON PLANT METHOD HOURS '=.;.)

SUBMITTED FORM SU:!.

W@LlJ@

LLJ@

W Io Io Io Io I Lx.J@)

lli.J@

33 34 35 36 37 40

- 41 42 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

PRIME COMP.

SUPPLIER LAJ@)

43 REVISION NO. w 32 COMPONENT MANUFACTUR!:R BO

._l _x ___ I 9_._9_._9__,J@

44 47 [II§]

Settling of the charcoal in the filters caused the formation of void areas, and a bent support rod for the HEPA filters.

The charcoal-filters were subsequently replaced and tested satisfactory.

The support rod for the HEPA filters was repaired and tested I satisfactory.

ITEJ 1

a s FACILITY STATUS

~W

% POWER OTHER STATUS @

1110 10 I@),__! _N_A~------

a.9 10 12 n

ACTIVITY CONTENT

~

RELEASC:D OF RELEASE AMOUNT.OF AC71VITY ~

~

W@) LlJ@,__J ___

NA_._. ----

a s 10 1,

44 PERSONNEL EXPOSURES C\\

BO METHOD OF A

DISCOVERY DISCOVERY DESCRIPTION \\3

~(ivl'"--'-*~~-R_o_u_t_i_n_e~T_e~s_t~~~~~~~~~~~~-'

45 46 80

_LOCA,ION OF RELEASE @

NA

.45 80 NUMBER

(.;":;"\\ TYPE

>ESCRIPTION

~

I o I o I o !~@..__ ________________________ __,

NA a s 11 12

~3 so

?ERSONNEL INJURIES Q

NUMBER DESCRIPTIONO

~

I o I o I o l@L.__. ________________________


1 NA

. 80

~ass OF OR D;~AGE 1

0 F.
.CI LITY (.2\\

TYPE

DESCRIPTION

V

~(s).__ _____________________________ ___,

NA 7

8 9

10 so PUBLICITY G\\

NRC SE O v

ISSUE De;:\\ DESCRIPTION~

U NL*

2TI] ~6....._ ____________________ __,

J I I I I I I I I I I I I~

NA ssos10 2 1

£~~~~~-~~E~

J

  • L.

c'"ON:C:: (:~4; 9

357 3184 Wilson 30.,

e e

ATTACHMENT 1 SURRY POWER DOCKET NO:

STATION, Unit 1 50-280 80-064/03L-O 09-16-80 REPORT NO:

EVENT DATE:

TITLE OF REPORT:

DEFECTIVE CHARCOAL FILTER

1.

Description of Event

With Unit 1 at cold shutdown and Unit 2 at full power the charcoal filters 3A and 3B located in the Auxiliary Building, were determined not to be ac-ceptable as a result of DOP and Freon 112 testing as required by T. S. 4.12. B.

This testing was performed in preparation for refueling of Unit 1.

This event is reportable per T.S. 6.6.2.b(2).

2.

Probable Consequences:

These filters are designed for use during refueling or,a LOCA, as well as intermittent use during normal operations.

Local air samples are routinely taken in the Aux. Building.

Those samples taken during the time the filter bank was not at the required efficiency did not indicate any abnormal con-ditions.

The air passing through the Ventilation Vent radiation monitor, which is in continuous operation, showed normal readings since the last time the filters were tested satisfactorly on April 3, 1980.

Refueling was not commence(j°until the filters were returned to design efficiency.

Therefore the health and safety of the public were not affected.

3.

Cause

Settling of the charcoal in the filters caused the formation of voids in the charcoal loading, and bent support rod in the HEPA filter housing.

4.

Immediate Corrective Action

The immediate corrective action was to initiate activities to replace the defective filt~r material.

5.

Subsequent Corrective Action:

The subsequent corrective action was to rep~ace banks prior to commencing refueling operations.

filters was repaired ~nd treated satisfactory.

the charcoal in the filters The Support rod for HEPA

6.

Action To Prevent Recurrence:

7.

A design change to the Auxiliary Building filter system is presently in progress.

This change will upgrade the system and provide for improved surveillance.

Generic Implications:

None l