05000280/LER-1979-015-03, /03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Procedural Inadequacy.Procedures Modified

From kanterella
(Redirected from ML18114A602)
Jump to navigation Jump to search
/03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Procedural Inadequacy.Procedures Modified
ML18114A602
Person / Time
Site: Surry Dominion icon.png
Issue date: 05/22/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18114A599 List:
References
LER-79-015-03L-01, LER-79-15-3L-1, NUDOCS 7905250154
Download: ML18114A602 (2)


LER-1979-015, /03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Procedural Inadequacy.Procedures Modified
Event date:
Report date:
2801979015R03 - NRC Website

text

i

1.

i*

I !

-.-* ------------***** -~'-'--.- -* --*----

~h,c FGRM':;s-ci

~7-771 e

LICENSEE EVENT RE?ORA (PL.:.ASE ?Rli'IT OR TY?:.:..L.J... REQUIRED. INFORMATION I r-;-n ! v1 A! s I PI s I 1 IG)i o I o I - I o I 0_1 9 I o 1 o I -_Io I oJG)L4 I 1_ 1_ 1_J 1 I 1__101 __ ! __ _J 0

i UC'=.;'s5C.: C:JQC i-'
5 L~C~J~S
:: i'lU,'"'IBER

.:.o LlC.;:.:'J::>c. TY?~

.JO

~7 -....- * =o

. ;=~~~~ ~@ / o I. s I o I o I o I 2 I 8 I o 101 o I 4 I 2 I 2 I 7 I 9 !@ ! o I s \\ 2 ! 2 I 7 ! g I G)

... au:

50 Sl CCC;<5T NUMac:~

- SO 69 EVENT CATI;
4
3 R~c.R.T ~T=

30

~'/::NT uE.SC:=ll?TIGN,:l.NO PRas.:..aLS C8NSEQU2NCE.5 (iQ)

~

I While reviewing Liquid Waste Release'1:orms it was determined that on two occasions, on 4-22-79, releases were made which contained'1;sotope activity suinrn'.3-tions gr~ater i *) :.! i than l.SE-03 µCi/cc.

In each case the Liquid Haste Radiation Honitor did not alarm r high and trip the release valve as required by Technical Specification 3.7.E.

i.:; ! :: I

!...' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -.... ;. - - - - ~

. CG] ! Since 1:h~ releases did not exceed the limits allowed by Tech. Spec. 3.11.A.2 and

~

1 10CFR20 App. B, the heal th and safety of the public were not affected.

This event is

~

/reportable.per Technical Specifi~ation 6,h,2,h.(Q~.

7 3

3 SYSTEM CCOE

!MIA!@

9 10 CO.USE.

co.us.;*

coos SUS COOS COMPONENT COO.I:

~@ L!2..[@ U I z I z I z I z t z !@

11 12 1:1 1S SEOUii:NTIA1-OCCUR A ENCE r.'.:;\\

l..=RIAO c2'/ENTV!:A. R AEi'OHTNO.

COCS.

'0 ?.:?ORT I 7 I 9 !

l l_

! 0 I 11 5 I l /}

I O I 3 I NUMSE.rl 21

,2.

23

24.
5.

27 28

.9 COMP.

susco.oa LU 19

is,m,n-.

VAi.Vi:

SUSCCOE l.Ll@.

. :a

~CT'ION runJRE EFF'::C.

SHUTDOWN

~ ATT.;l.Cl-fMli:l*rr NPRQ-1, P'l'!IMECOMP.

RSVlSlCN 1110.

L2J J:=.

c:::lMPONE'IT

.IIUI',! u,: ACTl.)F{ E."I ao

,.:.Karl ACTION ON P1..A."l!T METrlOO HOURS 'cl SUSMl-rT"::u FORM ::iU8.

SU??U6'1 l£.J@L!.l@ W@ UJ I o l o I o I o l.* W<§)-

lJLl@. ltl@

.::l.

l4 JS
s 37

.10 41

  • 42 4J.

lz I 9 I 9 I 9j@)

C.).USZ DE.SCl't!FTlON ANO CORA~CTlVE ACTIONS @

47 Ll...12.J J The Liquid Uaste Radiation Honitor 2 ~on high activity_ fl.5 R-03'.*

uCi/ccL provides a trip signal to the Liquid. Waste Release valve. Since the monitor C:an be calibrated to I.

(iJ.i].,L-------------.....;_.....;_ ____,._ _ __,.. _______.;,__ _____ ~---

~

I one.isotope only,- administrative control disallows any releases.which contain activ:i.tVJ.

I IIZt. l.......~~~~...:.~~~.;_:.~~~~~~~~~~~~~~~~~~~__;;;__,...~~~~~------~~~~~~~----~;,1 summations greater than :J_.SE-03..uCi/cc.. However,.a* pro~clural ina<lequacy resulted in 1***

Li.Ill r::rJ'?J lthecaforementioned. *releases. The_ Liquid Waste -Re':Leci:se forms have-- be~n* -modified.

3 F"'ClUTI*

(.;;;\\

sr;.n.:s

'1.PaWS-*

OTr-lSSTA:rtlS.. v

[!J}l ~@ IO / 0 I O J@l Unit 2 Defueled 7

3 10

. l'Z 1"l

...c.tVI~

C:::NT:NT Q\\

!E-.;ASciJ a
= ReL:AS;.

AMOUNT oF ACTIVITY '2;;

fTITj lij@ UJ(§f i... __

N_A ____

_;.i.

7 3

3 lO 11 M!:il-!000~.

Cls:..:l'VER'I' O!!SCt;~,

OISCCVSlY I ~@I Review of forms.

44-45 46**

I

.~TIOH*O~ R-El..$l,S.:

NA 4-4*

45 I

so

?:."!SONNE- :XPCSt.l.RES r.::;\\

[ill] I ci'l1Mor O 1@1..,r1@\\..r_=~...:~:...* A:...IPTl_o_"'_'-:::=J_:!9 __________

1 3

9 11

!2

!:l

?S;iSONNIR IN..!UrllcS r,:;-:;'\\

~IUMBE:=t-OESCrllFT'IONO

. CLl.Ll. I O l O I O l@)L_._.-:1::..:..:~A..:._ ____________ ~----..--.---~

j

. 7 3

9 11 12 80 l *

.css o~ aR OAM""G=.o F..OUTY G 7'"f?:

DESCrll?TlON l.::::::J

! C£TIJ Lu@t._ ____

.J.J,.Q.. ________ ------------------_.,.J 1

3 9

  • 10 ao l

lSStJ:SLl~~l?TlON@

790~2-50/S-f

, uID W81--_____

NA ________

1 1,,,,,, 1, 1,,.~

l 1

a 9

10 6a 63 ao -;

j W. L. Stewart

(~04) 357-3184 M,i.,y;:; r,;: :nic::011..:ii=~ ---*-**-** _____

?HONE:

(Attachment, page 1 of l)e Surry Power Station, Unit 1 Docket No: 50-280 e

Report No: 79-015/031-0 Event Date: 04-22-79 Liquid Waste Release

1.

Description of Event

Uhile reviewing Liquid Haste Release forms, it was determined that on two occasions, on 4-22-79, releases were made which'contained isotope activity -su~ations

  • greater than l.5E-03 µCi/cc.

In each case, the Liquid Waste Radiation monitor did not alarm high and trip the release valve as. required by Technical Specification 3.7.E.

2.

Probable Consequences and Status of Redundant Systems:

3.
4.

The Liquid Haste Radiation monitor, on high activity [1.5 E-03 * "µCi/cc]~ provides a tr'ip signal to the Liquid *waste Release valve.

Since the-monitor can be calibrated to one isotope only, administrative control disallows any releases which contain activ-ity summations greater_ than l.5E-03.

However, a procedural inadequacy resulted in the aforeRentioned releases.

Since the releases did not exceed the limits allowed by Technical Specification 3.11.A.2 and 10CFR20 App. B, the health and safety of the public were not affected.

Cause

A procedural inadequacy caused this event.

Immediate Corrective Action

A check of the waste releases was done to verify compliance with 10 CFR 20, Appendix B.

5.

Subsequent Corrective Action:

The Liquid Waste Release forms have been modified to include additional checks and signatures.

Personnel were instructed to use more care in filling out release forms.

6.

Actions Taken to Prevent Recurrence:

No further corrective action will be required.

7?

Generic IBplications:

none