ML18114A599

From kanterella
Jump to navigation Jump to search
Forwards LERs 79-014/03L-0,79-015/03L-0 & 79-016/03L-0
Date released: 12/10/2018 Download: ML18114A599


LER 79-016/03L-0 on 790425:cracks Noted in Concrete Support for 1-RH-E-1A & 1-RH-E-1B.Caused by Thermal Expansion of Heat Exchanger.Cracks Repaired.Heat Exchanger Supports Will Be Modified to Allow for Thermal Expansion
ML18114A603
Person / Time
Site: Surry Dominion icon.png
Issue date: 05/22/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18114A603 (2)
LER 79-015/03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Procedural Inadequacy.Procedures Modified
ML18114A602
Person / Time
Site: Surry Dominion icon.png
Issue date: 05/22/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18114A602 (2)
LER 79-014/03L-0 on 790422:liquid Waste Disposal Radiation Monitor Failed to Give High Alarm & Trip Release Valve. Caused by Instrument Drift in High Alarm Setpoint.All Liquid Waste Releases Were Secured & Alarm Board Checked
ML18114A601
Person / Time
Site: Surry Dominion icon.png
Issue date: 05/22/1979
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18114A601 (2)
Forwards LERs 79-014/03L-0,79-015/03L-0 & 79-016/03L-0
ML18114A598
Person / Time
Site: Surry Dominion icon.png
Issue date: 05/22/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18114A598 (1)