.e e May 1 0, 1 990 Docket No-5. 50-272 and 50-311 DISTRIBUTION w/enclosure:

Docket File 50-272/311 MO'Brien Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric and Gas Company

Dear Mr. Miltenberger:

NRC PDR JStone Local PDR MThadani PDI-2 Reading OGC SVarga EJordan 8Boger ACRS (10)

WButler PSwetland JDNeighbors EMurphy

SUBJECT:

WESTINGHOUSE REASSESSMENT OF BULLETIN 88-02 RESPONSES (TAC NOS. 67320 AND 67321)

RE:

SALEM GENERATING STATION, UNITS 1 AND 2 A number of PWR licensees contracted with Westinghouse to perform the analyses requested by NRC Bulletin 88-02, "Rapidly Propagating Fatigue Cracks in Steam Generator Tubes.

11 During its review of these analyses, the staff noted a pattern of deficiencies affecting a number of these analyses and requested Westinghouse to review its analyses to identify and address these deficiencies.

In response, Westinghouse informed the NRC staff of its plans to reassess and update these analyses. A copy of the Westinghouse letter is enclosed.

You are requested to submit the Westinghouse reassessment to the NRC when you receive it so that the staff can complete its review of this issue.

You are reminded that item C.l. of Bulletin 88-02, enhanced primary-to-secondary leak rate monitoring program, is to be continued until the staff has reviewed and approved your response.

Enclosure:

As stated cc w/enclosure:

See next page

[67320/l]

POI-2/PM JStone:mj 5 l\\O /90 POI-2/D l?

WButler 5 1\\\\)/90

(

~--

9005220121 900510 PDR ADOCK 05000272 Q

PDC

---~

Sincerely, ORIGINAL SIGNED BY:

James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

.it;

.9

~r. Steven E. Miltenberger

~ublic Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Conner and Wetterhahn Suite 1050 1747 Pennsylvania Avenue, NW Washington, DC 20006 Richard Fryling, Jr., Esquire law Department - Tower 5E 80 Park Place Newark, NJ 07101 Mr. l. K. Miller General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. S. La8runa Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Mr. Thomas P. Johnson, Senior Resident Inspector Salem Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Dr. Jill Lipoti, Asst. Director Radiation Protection Programs NJ Department of Environmental Protection CN 415 Trenton, NJ 08625 Maryland People's Counsel American Building, 9th Floor 231 East Baltimore Street Baltimore, Maryland 21202 Mr. J. T. Robb, Director Joint Owners Affairs Philadelphia Electric Company 955 Chesterbrook Blvd., 51A-13 Wayne, PA 19087 Salem Nuclear Generating Station Richard 8. McGlynn, Commission Department of Public Utilities State of New Jersey 101 Commerce Street Newark, NJ 07102 Regional Administratori Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary 0. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Bruce A. Preston, Manager Licensing and Regulation Nuclear Department P.O. Sox 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Mr. Scott B. Ungerer MGR. - Joint Generation Projects Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Mr. a a ck Urban General Manager, Fuels Department Delmarva Power & Light Company 800 King Street Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:

Chief Engineer 231 E. Baltimore Street Baltimore, MD 21202-3486