Docket.Nos. 50-272/311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

Aug~st 21,, 198.

SUBJECT:

SUITABILITY OF RESPONSE RELATED TO NRC BULLETIN 88-11, "PRESSURIZER SURGE LINE THERMAL STRATIFICATION", ITEM 1.b (TAC NOS. 72161/72162)

RE:

SALEM GENERATING STATION, UNIT NOS. 1 AND 2 By letter dated May 31, 1989, PSE&G forwarded the justification for continued operation (JCO) for Salem 1 and 2, based on the continued integrity of the pressurizer surge line. The letter also referred to a generic bounding analysis (WCAP 12277, Proprietary and WCAP 12278, Non-proprietary) being prepared by the Westinghouse Owners' Group (WOG) to be sent to the NRC by June 15, 1989.

Your letter specifically requested the staff to notify you if the information provided was sufficient to allow continued operation of Salem 1 and 2 while the detailed fatigue analysis is being prepared. Although the staff has not completed its detailed evaluation of the WOG generic bounding analysis, we have reviewed your response and conclude that the information you provided is sufficient to allow continued operation while the detailed fatigue analysis, as requested in Item 1.d of Bulletin 88-11, is being prepared.

cc: See next page DISTRIBUTION:

I5ocket File JS tone EJordan

[SEM LTR]

Sincerely, Isl James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation NRC PDR/LPDR PDI-2 Rdng SVarga/BBoger OGC ACRS (10)

M0 1 Brien MThadani WButler BGrimes

e UNITED STATES e

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket Nos. 50-272/311 Mr. Steven E. Miltenberger Vice President and Chief Nuclear Officer Public Service Electric & Gas Company Post Office Box 236 Hancocks Bridge, New Jersey 08038

Dear Mr. Miltenberger:

August 21, 1989

SUBJECT:

SUITABILITY OF RESPONSE RELATED TO NRC BULLETIN 88-11, "PRESSURIZER SURGE LINE THERMAL STRATIFICATION", ITEM 1.b (TAC NOS. 72161/72162)

RE:

SALEM GENERATING STATION, UNIT NOS. 1 AND 2 By letter dated May 31, 1989, PSE&G forwarded the justification for continued operation (JCO) for Salem 1 and 2, based on the continued integrity of the pressurizer surge line. The letter also referred to a generic bounding analysis (WCAP 12277, Proprietary and WCAP 12278, Non-proprietary) being prepared by the Westinghouse Owners' Group (WOG) to be sent to the NRC by June 15, 1989.

Your letter specifically requested the staff to notify you if the information provided was sufficient to allow continued operation of Salem 1 and 2 while the detailed fatigue analysis is being prepared. Although the staff has not completed its detailed evaluation of the WOG generic bounding analysis, we have reviewed your response ~nd conclude that the information you provided is sufficient to allow continued operation while the detailed fatigue analysis, as requested in Item 1.d of Bulletin 88-11, is being prepared.

cc: See next page Sincerely,

~(~

James C. Stone, Project Manager Project Directorate I-2 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

1- -----

Mr. Steven E. Miltenberger Public Service Electric & Gas Company cc:

Mark J. Wetterhahn, Esquire Conner and Wetterhahn Suite 1050 1747 Pennsylvania Avenue, NW Washington, DC 20006 Richard Fryling, Jr., Esquire Law Department - Tower 5E 80 Park Place Newark, NJ 07101 Mr. L. K. Miller General Manager - Salem Operations Salem Generating Station P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. S. LaBruna Vice President - Nuclear Operations Nuclear Department P.O. Box 236 Hancocks Bridge, New Jersey 08038 Kathy Halvey Gibson, Resident Inspector Salem Nuclear Generating Station U.S. Nuclear Regulatory Commission Drawer I Hancocks Bridge, NJ 08038 Richard F. Engel Deputy Attorney General Department of Law and Public Safety CN-112 State House Annex Trenton, NJ 08625 Dr. Jill Lipoti, Ph.D New Jersey Department of Environmental Protection Division of Environmental Quality Radiation Protection Programs State of New Jersey CN 415 -

Trenton, NJ 08625 Salem Nuclear Generating Station Richard B. McGlynn, Co11111ission Department of Public Utilities State of New Jersey 101 Commerce Street Newark, NJ 07102 Regional Administrator, Region I U. S. Nuclear Regulatory Co111T1ission 475 Allendale Road King of Prussia, PA 19406 Lower Alloways Creek Township c/o Mary O. Henderson, Clerk Municipal Building, P.O. Box 157 Hancocks Bridge, NJ 08038 Mr. Bruce A. Preston, Manager Licensing and Regulation luclear Department P.O. Box 236 Hancocks Bridge, NJ 08038 Mr. David Wersan Assistant Consumer Advocate Office of Consumer Advocate 1425 Strawberry Square Harrisburg, PA 17120 Mr. Scott B. Ungerer MGR. - Joint Generation Projects Atlantic Electric Company P.O. Box 1500 1199 Black Horse Pike Pleasantville, NJ 08232 Mr. Jack Urban General Manager, Fuels Department Delmarva Power & Light Company 800 King Street Wilmington, DE 19899 Public Service Commission of Maryland Engineering Division ATTN:

Chief Engineer 231 E. Baltimore Street Baltimore, MD 21202-3486