FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP Non-Proprietary Finite Element Seismic Models for SSI Analyses of the NI Buildings Revision 2 Non-Proprietary December 2017 Copyright 2017 Korea Electric Power Corporation &
Korea Hydro & Nuclear Power Co., Ltd All Rights Reserved
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP ii Non-Proprietary REVISION HISTORY Revision Date Page Description 0
November 2014 All First Issue 1
February 2017
- Abstract, Pages 1, 13 A minimum seismic gap of 2 in. between RCB and AB is changed to 6 in. by response to RAI 183-8197, Question 03.07.02-3, Rev.0 Pages 2, 13 The embedment depth of AB building is revised by response to RAI 253-8300, Question 03.07.01-6, Rev.0 Pages 2, 3 The description related 3-D FEM development for SSI analysis is revised by response to RAI 252-8299, Question 03.07.02-7, Rev.2 Pages 7, 8, 9, 10, 26, 27 The description and tables of floor loads for RCB are added by response to RAI 252-8299, Question 03.07.02-7, Rev.2 Pages 12, 62 The description and figure related modeling of RCS support are added by response to RAI 252-8299, Question 03.07.02-7, Rev.2 Page 20 The description of the SFG and lean concrete backfill for combined NI SASSI model is revised by response to RAI 320-8383, Question 03.08.05-19, Rev.1 Pages 37, 38 The comparison results of fine and coarse mesh model are revised by response to RAI 252-8299, Question 03.07.02-10, Rev.1 2
December 2017 Pages 2, 20, 22 The descriptions, table related S5 soil profile are deleted by response to RAI 252-8299, Question 03.07.02-9, Rev.2 Page 16 The editorial error is corrected to clearly describe the sentence by the response to RAI 249-8323, Question 03.08.01-16, Rev.1 This document was prepared for the design certification application to the U.S. Nuclear Regulatory Commission and contains technological information that constitutes intellectual property of Korea Hydro & Nuclear Power Co., Ltd. Copying, using, or distributing the information in this document in whole or in part is permitted only to the U.S. Nuclear Regulatory Commission and its contractors for the purpose of reviewing design certification application materials. Other uses are strictly prohibited without the written permission of Korea Electric Power Corporation and Korea Hydro & Nuclear Power Co., Ltd.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP iii Non-Proprietary ABSTRACT This technical report provides the finite element model used in the soil-structure interaction analysis for the APR1400 nuclear island structures. The nuclear island structures consist of the reactor containment building and auxiliary building, and are founded on the monolithic common basemat. Above the basemat, the reactor containment building and auxiliary building are separate structures with a minimum seismic gap of 6 in. Therefore, the finite element models for each building are developed separately.
Two finite element models for each building, namely, a fine-mesh finite element model and a coarse-mesh finite element model, are developed using the ANSYS computer program.
The fine-mesh finite element model is developed with a finite element mesh that is sufficiently refined for a detailed structural analysis. The coarse-mesh finite element model is developed with larger finite element size to reduce the models total number of degrees of freedom to a level that can be accommodated by the presently available SASSI computer program.
Model validation is made in which the dynamic properties of coarse-mesh finite element model are compared against the corresponding dynamic properties of the fine-mesh finite element model. This validation is intended to demonstrate that both models are capable of representing the natural vibration modal properties sufficiently accurately up to a high frequency cut-off of at least 50 Hz.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP iv Non-Proprietary TABLE OF CONTENTS 1
INTRODUCTION.................................................................................................. 1 2
METHODOLOGY OF FEM DEVELOPMENT FOR NI STRUCTURES...................... 2 3
REACTOR CONTAINMENT BUILDING MODEL.................................................... 4 3.1 Description of RCB Structures........................................................................................................ 4 3.1.1 Containment Structure.................................................................................................................... 4 3.1.2 Primary Shield Wall......................................................................................................................... 5 3.1.3 Secondary Shield Wall.................................................................................................................... 5 3.1.4 Reactor Coolant System................................................................................................................. 5 3.1.5 Internal Structure............................................................................................................................. 6 3.2 Development of Finite Element Models for RCB Structures.......................................................... 6 3.2.1 Geometry and Coordinate System.................................................................................................. 6 3.2.2 Material Properties.......................................................................................................................... 7 3.2.3 Structural Member Modeling........................................................................................................... 7 3.2.4 Minimum Frequency of Seismic Wave Passage............................................................................. 7 3.2.5 Modeling of Mass (Structural Mass, Live Loads, Floor Loads and Equipment Loads)................... 7 3.2.6 Modeling of Damping...................................................................................................................... 8 3.2.7 Modeling of Hydrodynamic Effects for the IRWST.......................................................................... 9 3.2.8 Modeling of Polar Crane............................................................................................................... 10 3.2.9 Modeling of CS.............................................................................................................................. 11 3.2.10 Modeling of PSW.......................................................................................................................... 11 3.2.11 Modeling of SSW.......................................................................................................................... 11 3.2.12 Modeling of RCS Support............................................................................................................. 12 3.2.13 Mesh Sizes for Generation of ANSYS Fine and Coarse 3-D FEM of RCB.................................. 12 4
AUXILIARY BUILDING MODEL.......................................................................... 13 4.1 Description of AB Structure.......................................................................................................... 13 4.2 Development of Finite Element Models for AB Structure............................................................. 13 4.2.1 Coordinate System........................................................................................................................ 13 4.2.2 Material Properties........................................................................................................................ 13 4.2.3 Common Basemat for AB and RCB.............................................................................................. 13 4.2.4 Shear Walls, Partial Wall Openings (Doors, Corridors, and Others), Equivalent Wall Thicknesses and Equivalent Mass Densities................................................................................ 14 4.2.5 Floor Slabs, Partial Floor Openings, Major Equipment, Earthquake Live Loads, Roof Snow Loads, Other Miscellaneous Dead Loads, and Equivalent Mass Densities................................. 14 4.2.6 Modeling for Out-of-Plane Vertical Flexibility of Floor Slabs......................................................... 14
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP v
Non-Proprietary 4.2.7 Modeling for Columns and Girders............................................................................................... 15 4.2.8 Concentrated Masses for Minor Structural Components Not Modeled........................................ 15 4.2.9 Modeling of Hydrodynamic Loads for AFW and FHA Tanks........................................................ 15 4.2.10 Mesh Sizes for Generation of ANSYS Fine and Coarse 3-D AB FEM......................................... 15 4.2.11 Geometry Plots of ANSYS Fine and Coarse 3-D AB FEM........................................................... 16 4.2.12 Minimum Frequency of Seismic Wave Passage........................................................................... 16 5
VERIFICATION OF SEISMIC MODEL................................................................. 17 5.1 Verification of RCB Model............................................................................................................ 17 5.1.1 Comparison of Modal Analysis Results........................................................................................ 17 5.1.2 Comparisons of Static Displacements.......................................................................................... 17 5.1.3 Comparisons of ISRS.................................................................................................................... 17 5.1.4 SASSI Model Validation................................................................................................................ 18 5.2 Verification of AB Model............................................................................................................... 18 5.2.1 Comparison of Modal Analysis Results........................................................................................ 18 5.2.2 Comparisons of Static Displacements.......................................................................................... 18 5.2.3 Comparisons of ISRS between ANSYS Fine, ANSYS Coarse, and SASSI Fixed-base Models. 19 6
COMBINED NI SASSI MODEL............................................................................ 20 6.1 Modeling of Structural Components of Combined NI................................................................... 20 6.2 Common Foundation Basemat..................................................................................................... 20 6.3 Soil Excavation............................................................................................................................. 20 6.4 Bottom Lean Concrete and Side Soil Backfilled with SFG........................................................... 20 6.5 Connections between Structural Concrete and Soil..................................................................... 20 7
REFERENCES.................................................................................................... 21
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP vi Non-Proprietary LIST OF TABLES Table 2-1 Maximum Frequency of Seismic Wave Propagation......................................................... 22 Table 3-1 Summary of the Main Dimensions of RCB........................................................................ 23 Table 3-2 Material Properties for Concrete and Steel....................................................................... 24 Table 3-3 Effective Cracked-Concrete Modulus of Elasticity............................................................. 25 Table 3-4 Seismic Live Load, Roof Snow Load, and Miscellaneous Dead Load.............................. 26 Table 3-5 Hydrodynamic Properties for Equivalent Mechanic Models In-containment Refueling Water Storage Tank........................................................................................................... 27 Table 4-1 Main Dimensions of AB Structure Security........................................................................ 28 Table 4-2 Material Properties of Uncracked-Concrete...................................................................... 29 Table 4-3 Material Properties of Horizontal Cracked-Concrete Model.............................................. 30 Table 4-4 Material Properties of Vertical Cracked-Concrete Model.................................................. 31 Table 4-5 Material Properties of Structural Steel............................................................................... 32 Table 4-6 Major Equipment Loads..................................................................................................... 33 Table 4-7 Seismic Live Load, Roof Dead Loads, Roof Snow Loads, and Other Miscellaneous Dead Loads........................................................................................................................ 34 Table 4-8 Out-of-Plane Vertical Floor Flexibility Adjustment Factors for the Coarse Model............. 35 Table 4-9 Summary of ANSYS Fine and Coarse 3-D FEMs of AB................................................... 36 Table 5-1 Containment Structure, Major Modes Comparison Fine vs Coarse Mesh Models........... 37 Table 5-2 Internal Structure, Major Modes Comparison Fine vs Coarse Mesh Models.................... 37 Table 5-3 AB, Comparisons of Major Modal Frequencies in X-Direction.......................................... 38 Table 5-4 AB, Comparisons of Major Modal Frequencies in Y-Direction.......................................... 40 Table 5-5 AB, Comparisons of Major Modal Frequencies in Z-Direction.......................................... 41
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP vii Non-Proprietary LIST OF FIGURES Figure 3-1 Containment Structure Overview - Fine Mesh Model (Y points to Plant North)............... 42 Figure 3-2 Plan View of Rectangular Concrete Massive Block of Primary Shield Wall...................... 43 Figure 3-3 Isometric View of Primary Shield Wall and Concrete Pedestal......................................... 44 Figure 3-4 Reactor Coolant System Overview.................................................................................... 45 Figure 3-5 Concrete Cylindrical Volume (167 ft Diameter) with RV Pit Inside.................................... 46 Figure 3-6 Isometric View of Internal Structure................................................................................... 47 Figure 3-7 Rectangular Cartesian Coordinate System of RCB........................................................... 48 Figure 3-8 Elevation View of Reactor Containment Building Showing Typical Section of IRWST..... 49 Figure 3-9 Plan View of IRWST at El. 81-0....................................................................................... 50 Figure 3-10 Plan View of Equivalent Mechanical Horizontal Impulsive Model of Tank-Water System for IRWST.......................................................................................................................... 51 Figure 3-11 Plan View of Equivalent Mechanical Horizontal Convective Models of Tank-Water System for IRWST............................................................................................................. 52 Figure 3-12 Section View of Reactor Containment Building Showing Hydrodynamic Impulsive and Convective Models of Tank-Water System for IRWST...................................................... 53 Figure 3-13 Polar Crane ANSYS Modeling........................................................................................... 54 Figure 3-14 Hot and Cold Legs Openings (Typical Cross Section)...................................................... 55 Figure 3-15 Openings in PSW Model for Hot and Cold Legs............................................................... 56 Figure 3-16 Transition between PSW and Massive Concrete Block at El. 130-0............................... 57 Figure 3-17 Interface between Shell and Solid Elements..................................................................... 58 Figure 3-18 Idealization for the RV Openings in PSW.......................................................................... 59 Figure 3-19 Idealization of the SSW and Common Basemat Top........................................................ 60 Figure 3-20 Shell - Solid Overlap between El. 94-6 to El. 100-0...................................................... 61 Figure 3-21 Connection between RCS Supports and Solid Elements.................................................. 62 Figure 4-1 Plan Layout of AB with Adjacent Buildings........................................................................ 63 Figure 4-2 Global Coordinate System of AB....................................................................................... 64 Figure 4-3 Common Basemat for AB and RCB.................................................................................. 65 Figure 4-4 ANSYS Coarse Mesh of the Common Basemat for AB and RCB.................................... 66 Figure 4-5 Fine Mesh of 10 ft Thick AB Basemat............................................................................... 67 Figure 4-6 Coarse Mesh of 10 ft Thick AB Basemat........................................................................... 68 Figure 4-7 ANSYS Fine 3-D FEM of Auxiliary Building....................................................................... 69 Figure 4-8 ANSYS Coarse 3-D FEM of Auxiliary Building.................................................................. 70 Figure 4-9 ANSYS Coarse 3-D FEM of Auxiliary Building, E-W Cutting at Column Line AG and Looking North..................................................................................................................... 71 Figure 4-10 ANSYS Coarse 3-D FEM of Auxiliary Building, N-S Cutting at Column Line 19 and Looking East...................................................................................................................... 72
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP viii Non-Proprietary Figure 5-1 RCB, Cumulative Mass Ratio for Frequencies in Translational X-Direction..................... 73 Figure 5-2 RCB, Cumulative Mass Ratio for Frequencies in Translational Y-Direction..................... 74 Figure 5-3 RCB, Cumulative Mass Ratio for Frequencies in Translational Vertical Z-Direction......... 75 Figure 5-4 Containment Structure (Translational Modes X or Y) - Mode 1........................................ 76 Figure 5-5 Containment Structure Drumming Mode Z - Mode 5........................................................ 77 Figure 5-6 IS Translational Mode X (E-W) - Mode 2 (CS Omitted from this Plot).............................. 78 Figure 5-7 IS Translational Mode Y (N-S) - Mode 2 (CS Omitted from this Plot)............................... 79 Figure 5-8 IS Vertical Mode Z - Mode 5 ( CS Omitted from this Plot)................................................. 80 Figure 5-9 Nomenclature of Selected Nodes for Containment Structure........................................... 81 Figure 5-10 Nomenclature of Selected Nodes for Primary Shield Wall................................................ 82 Figure 5-11 Nomenclature of Selected Nodes for Secondary Shield Wall........................................... 83 Figure 5-12 RCB, CS, Lateral Displacement, X-Direction.................................................................... 84 Figure 5-13 RCB, CS, Lateral Displacement, Y-Direction.................................................................... 85 Figure 5-14 RCB, CS, Vertical Displacement, Z-Direction.................................................................... 86 Figure 5-15 RCB, PSW, Lateral Displacement, X-Direction................................................................. 87 Figure 5-16 RCB, PSW, Lateral Displacement, Y-Direction................................................................. 88 Figure 5-17 RCB, PSW, Vertical Displacement, Z-Direction................................................................ 89 Figure 5-18 RCB, SSW, Lateral Displacement, X-Direction................................................................. 90 Figure 5-19 RCB, SSW, Lateral Displacement, Y-Direction................................................................. 91 Figure 5-20 RCB, SSW, Vertical Displacement, Z-Direction................................................................ 92 Figure 5-21 RCB, CS, ISRS, El. 104-0 (Comparison of the ANSYS Coarse and Fine Models)......... 93 Figure 5-22 RCB, CS, ISRS, El. 160-0 (Comparison of the ANSYS Coarse and Fine Models)......... 94 Figure 5-23 RCB, CS, ISRS, El. 255-0 (Comparison of the ANSYS Coarse and Fine Models)......... 95 Figure 5-24 RCB, PSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and Fine Models)...... 96 Figure 5-25 RCB, PSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and Fine Models)..... 97 Figure 5-26 RCB, PSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and Fine Models)..... 98 Figure 5-27 RCB, SSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and Fine Models)..... 99 Figure 5-28 RCB, SSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and Fine Models)... 100 Figure 5-29 RCB, SSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and Fine Models)... 101 Figure 5-30 RCB, CS, ISRS, El. 104-0 (Comparison of the ANSYS Coarse and the SASSI Models)
......................................................................................................................................... 102 Figure 5-31 RCB, CS, ISRS, El. 160-0 (Comparison of the ANSYS Coarse and the SASSI Models)
......................................................................................................................................... 103 Figure 5-32 RCB, CS, ISRS, El. 255-0 (Comparison of the ANSYS Coarse and the SASSI Models)
......................................................................................................................................... 104 Figure 5-33 RCB, PSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 105
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP ix Non-Proprietary Figure 5-34 RCB, PSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 106 Figure 5-35 RCB, PSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 107 Figure 5-36 RCB, SSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 108 Figure 5-37 RCB, SSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 109 Figure 5-38 RCB, SSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and the SASSI Models)............................................................................................................................ 110 Figure 5-39 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in X-Direction........................................................................................................................... 111 Figure 5-40 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in Y-Direction........................................................................................................................... 112 Figure 5-41 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in Z-Direction........................................................................................................................... 113 Figure 5-42 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at South-West Corner (Column Lines AB-12)......................................................................................... 114 Figure 5-43 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at North-West Corner (Column Lines AJ-12).......................................................................................... 115 Figure 5-44 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at South-East Corner (Column Lines AA-26)......................................................................................... 116 Figure 5-45 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at North-East Corner (Column Lines AK-26)......................................................................................... 117 Figure 5-46 AB Model Verification, ISRS at North-West Corner - El. 67-0....................................... 118 Figure 5-47 AB Model Verification, ISRS at East Face - El. 67-0..................................................... 119 Figure 5-48 AB Model Verification, ISRS at South-West Corner - El. 77-0...................................... 120 Figure 5-49 AB Model Verification, ISRS at East Face - El. 77-0..................................................... 121 Figure 5-50 AB Model Verification, ISRS at South-East Corner - El. 98-6....................................... 122 Figure 5-51 AB Model Verification, ISRS at North-East Corner - El. 98-6........................................ 123 Figure 5-52 AB Model Verification, ISRS at North-East Corner - El. 120-0...................................... 124 Figure 5-53 AB Model Verification, ISRS at East Face - El. 120-0................................................... 125 Figure 5-54 AB Model Verification, ISRS at South-West Corner - El. 137-6.................................... 126 Figure 5-55 AB Model Verification, ISRS at North-West Corner - El. 137-6..................................... 127 Figure 5-56 AB Model Verification, ISRS at South-West Corner - El. 156-0.................................... 128 Figure 5-57 AB Model Verification, ISRS at North-West Corner - El. 156-0..................................... 129 Figure 5-58 AB Model Verification, ISRS at South-West Corner - El. 174-0.................................... 130 Figure 5-59 AB Model Verification, ISRS at North-West Corner - El. 174-0..................................... 131 Figure 5-60 AB Model Verification, ISRS at North-West Corner - El. 195-0..................................... 132 Figure 5-61 AB Model Verification, ISRS at East Face - El. 195-0................................................... 133
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP x
Non-Proprietary Figure 5-62 AB Model Verification, ISRS at Slab AG-AH-21 El. 120-0..................................... 134 Figure 5-63 AB Model Verification, ISRS at Slab AG-AH-21 El. 137-6..................................... 135 Figure 5-64 AB Model Verification, ISRS at MCR Slab - El. 156-0................................................... 136 Figure 5-65 AB Model Verification, ISRS at FHA Roof - El. 213-6................................................... 137 Figure 6-1 Structural Model of SASSI 3-D FEM of Combined NI..................................................... 138 Figure 6-2 SASSI 3-D FEM of the Excavated Soil Volume for Combined NI Structure Foundation 139 Figure 6-3 SASSI 3-D FEM of the SFG and Lean Concrete Backfill for Combined NI Structures... 140 Figure 6-4 SASSI 3-D FEM of the Combined NI with Backfilled Soil................................................ 141
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP xi Non-Proprietary ACRONYMS AND ABBREVIATIONS 3-D three-dimensional AB auxiliary building AFW auxiliary feed water APR1400 Advanced Power Reactor 1400 ASCE American Society of Civil Engineers CL centerline CS containment structure DOF degrees of freedom E-W east-west FEM finite element model ICI in-core instrumentation IRWST in-containment refueling water storage tank IS internal structure ISRS in-structure response spectra KEPCO Korea Electric Power Corporation KHNP Korea Hydro & Nuclear Power Co., Ltd.
NI nuclear island NRC U. S. Nuclear Regulatory Commission N-S north-south OBE operating basis earthquake PSW primary shield wall PZR pressurizer RCB reactor containment building RCP reactor coolant pump RCS reactor coolant system RG regulatory guide RV reactor vessel SFG structural fill granular SG steam generator SRP standard review plan SSE safe shutdown earthquake SSI soil-structure interaction SSW secondary shield wall
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP xii Non-Proprietary Page intentionally blank
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 1
Non-Proprietary 1
INTRODUCTION The purpose of this technical report is to present the methodologies used to develop the finite element seismic models for the nuclear island (NI) structures. The NI finite element seismic models are developed for use in three-dimensional (3-D) seismic soil-structure interaction (SSI) analysis of the APR1400.
The NI structures are the reactor containment building (RCB) and auxiliary building (AB), which are founded on a monolithic common basemat. The RCB is structurally separate from the AB with a minimum seismic gap of 6 in. above the common basemat. The RCB is a seismic category I structure that consists of a pre-stressed concrete cylindrical shell, hemispherical dome, and reinforced concrete internal structure that are supported on a reinforced concrete mat foundation.
The AB wraps around the RCB, leaving a seismic gap space above the common basemat. The AB is a seismic category I structure that consists of reinforced concrete shear walls and floor slabs, which are lateral load-resisting systems, and frames that support the vertical loads.
The RCB and AB finite element models (FEMs) are developed separately and then combined (i.e., the AB structure, RCB structures, and the common basemat are combined in one coupled NI structural FEM). All finite element seismic models are developed and combined using the ANSYS (Reference 1) computer program. The ANSYS FEM of the combined NI is converted to a SASSI (Reference 2) 3-D FEM for seismic SSI analysis.
This technical report consists of seven (7) sections. Section 1 is an introduction that includes background information. Section 2 describes the methodology of the FEM development for the NI structures. Section 3 presents the modeling process for the RCB finite element seismic model. Section 4 describes the modeling process for the AB finite element seismic model. Section 5 describes the validation of the RCB and AB finite element seismic models. Section 6 provides the final combined FEM to be used in SSI analysis. Section 7 contains the cited references.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 2
Non-Proprietary 2
METHODOLOGY OF FEM DEVELOPMENT FOR NI STRUCTURES The following considerations are made in the FEM development for the APR1400 NI structures:
The APR1400 NI structures have a maximum embedded ratio (embedment depth/AB building height=53.7/171.8) of 0.313 and are considered embedded structures for the seismic SSI analysis.
Estimates of the maximum frequencies of seismic wave propagation for the eight (8) soil profiles defined in the APR1400 are shown in Table 2-1 for soil layers that are 11 ft thick in the embedment. Among the eight (8) soil cases, four (4) have a maximum frequency above 50 Hz. A soil layer thickness of 11 ft is considered adequate and is accordingly adopted as the mesh size for soil elements and for the NI structural FEM.
The 10 ft basemat is modeled by shell elements at the bottom surface of the basemat, rather than at the middle surface. This consideration can be justified as the SSI effects are accounted for more closely.
The effects of vertical shear deformation in a 10-ft-thick common basemat on the seismic SSI analysis are considered insignificant.
The effects of stiffnesses of local walls (not designed for the shear wall system) on the SSI response are considered small and are not included in the model.
The purpose of the model development is to create a 3-D FEM for SSI analysis of the APR1400 NI structures, which includes the RCB and AB founded on a common basemat. The 3-D SSI analysis is carried out using the SASSI program. The development of a complex 3-D finite element SASSI model of the NI structures consists of the following steps:
The ANSYS fine-mesh and coarse-mesh FEMs for the fixed-base RCB and the AB are first developed and analyzed with the fixed-base condition to (1) generate 1-g lateral static-load response displacements, (2) extract fixed-base dynamic modal properties (natural frequencies and associated mode shapes and participation factors), and (3) develop fixed-base, 5%-damped in-structure response spectra (ISRS) at selected sufficiently representative structure locations.
The ANSYS coarse-mesh models are verified against their corresponding ANSYS fine-mesh FE models to ensure that the model properties of the ANSYS coarse-mesh models are dynamically adequate as compared to the ANSYS fine-mesh FE models.
When the ANSYS coarse-mesh models of the RCB and the AB are verified, the two models are combined to create an ANSYS coarse-mesh FE model of the NI structures.
The fixed-base ANSYS coarse-mesh FE model of the NI structures is converted to the fixed-base SASSI structure model using the ACS SASSI model translator. The converted SASSI structure model is checked manually to ensure that the SASSI structure model is appropriately converted from the ANSYS model.
The converted SASSI fixed-base structure model is analyzed for the fixed-base condition to develop fixed-base seismic acceleration response transfer functions and the corresponding 5%-
damped ISRS at the same selected representative structure locations as those selected for the ANSYS model. These ISRS results are compared with the corresponding results obtained from the fixed-base ANSYS structure model to verify that the converted fixed-base SASSI structure model produces results which are sufficiently similar to the corresponding results of the fixed-base ANSYS structure model.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 3
Non-Proprietary The SASSI foundation model which is combined with the SASSI structure model consists of a common basemat structure model, an excavated soil volume model for the structure embedment developed to use the SASSI Direct Method (DM), and a backfill soil model, which is treated as a part of the structure model. The SASSI foundation model for the NI structure is so developed and checked manually.
The common basemat for the AB and the RCB is modeled separately by 4-node shell elements for the AB at the bottom surface of concrete foundation (El. 45-0) to specially account more closely for the soil-structure interaction effects, and by 8-node solid elements for the RCB concrete foundation. To ensure continuity of rotational deformation at the interface of the AB shell elements and the RCB solid elements, a dummy massless ring of shell elements is extended from the outside edge to the inside of RCB, beneath the solid elements. To simulate the relatively rigid 10-ft basemat between the top (El. 55-0) and the bottom (El. 45-0) surfaces of the concrete foundation for the AB, the AB walls and columns are extended from El. 55-0 to El. 45-0 with massless rigid beam elements.
The ability of the resulting SASSI FE SSI model to translate and rotate is demonstrated by observing that the resulting seismic response transfer functions are able to translate and rotate as a rigid body on the supporting soil.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 4
Non-Proprietary 3
REACTOR CONTAINMENT BUILDING MODEL This section describes the RCB structures and the methodology for developing the APR1400 RCB FEM.
3.1 Description of RCB Structures The APR1400 RCB is a safety-related seismic category I structure that consists of three concrete substructures (Reference 3):
Containment structure (CS)
Primary shield wall (PSW)
Secondary shield wall (SSW)
The CS is also called the pre-stressed concrete containment vessel. The PSW and the SSW are combined to form the reinforced concrete internal structure (IS) and are the supporting structures to the reactor coolant system (RCS).
The CS and IS are separated by a 2 in. gap and only connected at their basemat at El. 78-0. Therefore, there is no interaction between the two structures except through the common basemat. The structural elements between the CS and IS are included in the SSW. The primary dimensions of the RCB are listed in Table 3-1.
3.1.1 Containment Structure The CS consists of a cylindrical post-tensioned shell with 4.5 ft thick walls. The dome is hemispherical with 4 ft thick walls. The line at the intersection of the cylindrical and hemispherical shapes is called the spring line and lies at El. 254-6.
The CS has four openings, as follows:
Each opening has a diameter of 11.16 ft Two of the openings are on the north side, and others are on the east side.
The personnel emergency exit airlock openings (one on the north side and another on the east side) are at center El. 103-9 and azimuth 280°.
The personnel access airlock openings (one on the north side and another on the east side) are at center El. 159-9 and azimuth 234°.
The CS has one equipment hatch opening. The opening is on the east side, has a 26 ft circular opening, and is at center elevation at 167-6 and azimuth 280°.
The CS has three 14 ft wide buttresses with thicknesses varying from 7.0 ft to 7.5 ft. The buttresses are 120° apart. The first buttress starts at azimuth 30° from the north. See Figure 3-1.
The CS cylindrical shell is supported on the RCB concrete foundation base at El. 78-0. The interior of the CS shell structure is lined on with a 0.25 in steel liner plate, which acts compositely with the CS.
A polar crane is supported by the CS shell ring beam at El. 241-0. The polar crane bridge girders and trolley system are supported by an inner steel ring beam with a 71.62 ft radius at approximately 5.6 ft offset from the CS shell center line using steel corbels (brackets).
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 5
Non-Proprietary 3.1.2 Primary Shield Wall The IS includes the PSW and SSW. The IS is supported by a concrete basemat that extends from El. 45-0 to El. 78-0. The PSW is a concrete rectangular block with an area of 61-8 x 37-6 that extends from El. 69-0 to El. 130-0, as shown in Figure 3-2. The rectangular block supports two E-W walls with variable thicknesses that extend from the top of the rectangular block at El. 130-0 to their top elevation at 191-0, as shown in Figure 3-3. The concrete rectangular block has a 24 ft diameter opening that houses the reactor vessel (RV) in the east side. The west side of the rectangular block houses the in-core instrumentation (ICI) cavity.
The top of the concrete for the ICI cavity is at El. 106-6 on the west side, and the refueling pool is at El.
114-0 on the east side between the PSW and SSW. The concrete block has six openings, each 6 ft in diameter, which allows the hot and cold legs to penetrate the rectangular block that connects to the RV.
Inside the concrete pedestal support is a reactor cavity (pit) below the RV that extends from El. 69-0 to El. 78-0.
3.1.3 Secondary Shield Wall The SSW consists of a cylindrical perimeter wall with a 51 ft radius (at the centerline) that protects the primary shield structure. The SSW is 4 ft thick from top to bottom. The SSW acts as the primary supporting structure to the connecting slabs that are located between the PSW and SSW, and between the SSW and CS.
The connecting slabs are located at El. 114-0, 136-6, and 156-0 (operating deck). The space between the PSW and SSW at El. 78-0 and El. 100-0 is filled with concrete that forms a ring with a 51 ft radius that is penetrated by the rectangular block of the PSW.
The other major SSW components that are considered in this document are:
In-containment refueling water storage tank (IRWST)
Pressurizer (PZR) shaft The IRWST is an annular cylindrical tank that is 26 ft wide and 22 ft high and that has 3 ft thick exterior walls. The tank is separated from the CS by a 2 in. gap and is supported on top of the basemat. The tank roof slab supports the IS slabs above creating vertical load paths to the basemat.
The PZR structure is located at the North-West corner and is made of four (4) 2.75 ft thick concrete walls that form a square that extends to El. 200-0. The PZR walls are 21 ft long and are directly supported by both the PSW and SSW.
3.1.4 Reactor Coolant System The major RCS components are shown in Figure 3-4 and are as follows:
The RV, which is supported by four columns and by the PSW Two steam generators (SGs), which are supported horizontally by the PSW and SSW and vertically at the base by concrete pedestals at El. 112-10 The four (4) reactor coolant pumps (RCPs), which are supported laterally on beams spanning the PSW and SSW (at two elevations) and supported vertically (gravity) on a concrete pedestal at El. 103-0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 6
Non-Proprietary The PZR, which is supported laterally by its own encasement walls (shaft) and vertically by a concrete slab at its base 3.1.5 Internal Structure The IS foundation has two (2) cylindrical concrete volumes as follows:
The first volume shares a 10 ft deep common basemat with the AB from El. 45-0 to El. 55-0. This pedestal is 167 ft diameter, 33 ft in maximum thickness (from bottom El. 45-0, extending up to El. 78-0).
See Figure 3-5.
The top surface of the volume has a pit cavity 50.26 ft x 31.34 ft x10 ft deep under the RV center and is covered with a 0.25 in. steel liner plate. The basemat bottom surface is not straight but has a square saddle that is 85 ft long and 10 ft deep at the center. Therefore, the approximate center of the volume is 11 ft thick.
The second volume is a pedestal stacked above the IS cylindrical basemat portion. This volume has a diameter of 102 ft and is considered part of the SSW. It extends from El. 78-0 to El. 100-0 and supports the cylindrical SSW, as shown in Figure 3-6.
3.2 Development of Finite Element Models for RCB Structures 3.2.1 Geometry and Coordinate System The coordinate system that is used for the model development of the CS and SSW is primarily the cylindrical coordinate system because both structures are circular. The system is used for geometry modeling and for locating the lumped masses at the SSW circumference.
In contrast, the PSW and RCS use the rectangular Cartesian coordinate system.
The center lines of the CS and SSW are identical and are referred to as the centerline (CL) RCB. The center is at the origin (0, 0, Z) in the global Cartesian coordinate system (ft units) with. X=0, Y=0, and Z=vertical elevation of components based on drawings.
In general, the locations and dimensions of walls and the elevations of openings are defined in the structural drawings by the azimuth angle in degrees. The units that are used in the model are as follows:
Length : foot Weight : kip Stress : ksf Mass : kip-sec2/ft X, Y, and Z axes based on the rectangular Cartesian coordinate system correspond to the following, as shown in Figure 3-7:
The plant N-S direction is the global Y axis with:
Azimuth AZ. 180° for (+Y) pointing to the north.
Azimuth AZ. 0° for (-Y) pointing to the south.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 7
Non-Proprietary The East-West (E-W) direction is the global X axis with; Azimuth AZ. 270° for (+X) pointing to the east.
Azimuth AZ. 90° for (-X) pointing to the west The RV centerline is offset by 1 ft to the east from the center line of the RCB. The RCB centerline is at the origin of the model at (0, 0, 0). The RV centerline is at (1, 0, Z) in the Cartesian global coordinate system (i.e., X=1 ft, Y=0 ft, and Z=vertical elevation of RV components). Consequently, due to the 1 ft offset, the IS is only symmetric about the X global axis (E-W).
3.2.2 Material Properties The structural material strength, stiffness, and weight density that affect the dynamic responses of the RCB are summarized in Table 3-2.
For the uncracked concrete condition, the uncracked concrete stiffness properties are represented by the concrete modulus of elasticity (Ec) as given in Table 3-2 times the uncracked concrete gross section properties.
For the cracked concrete condition, the effective stiffnesses of reduced, cracked concrete section properties are represented by the reduced concrete modulus of elasticity ( ) times the uncracked concrete gross section properties. The reduced concrete modulus ( ) values used to represent cracked concrete stiffness in the RCB seismic analysis based on the American Society of Civil Engineers (ASCE) 43-05 (Reference 4) are summarized in Table 3-3.
3.2.3 Structural Member Modeling Structural members are modeled using finite elements as required by Subsection 4.5.4 in the APR1400 design criteria (Reference 5). Shear walls and main structural walls are modeled using shell elements in ANSYS with the element centerline modeled at mid-plane. Massive concrete areas are modeled using solid brick elements. Large aspect ratio and abnormal geometry in element shapes are avoided. Grating floors, being non-structural, are not modeled.
3.2.4 Minimum Frequency of Seismic Wave Passage For subgrade portions of the structure, the mesh size is controlled by the soil thickness, which is required to satisfy the minimum frequency. A cut-off frequency of 50 Hz is used for seismic wave passage through hard and moderate soil/rock profiles. Cut-off frequencies between 20 and 40 Hz are used for soft soil profiles.
3.2.5 Modeling of Mass (Structural Mass, Live Loads, Floor Loads and Equipment Loads)
The equivalent dynamic mass applied on the detailed finite element consists of the structure self-weight in addition to all permanent equipment weight. There is no live load assigned to the RCB slabs as floor loads. The masses are developed following the required APR1400 design criteria in Chapter 4, Subsection 4.7.4.
In addition to the structural mass, mass equivalent to a distributed floor load of 50 psf is considered to represent miscellaneous dead weight such as minor equipment, piping and raceway, as required in Section 4.6 of the APR1400 design criteria for structural containment loading. Also, a mass equivalent to 25% of floor live load or 75% of 75 psf of snow load required by U.S. Nuclear Regulatory Commission (NRC) Standard Review Plan (SRP) 3.7.2 (Reference 6), Part II, 3(D), in the acceptance criteria are applied on the roof. This criterion is applied to the CS dome. The seismic live load, roof snow load, and c
E c
E
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 8
Non-Proprietary miscellaneous dead load applied to slabs and dome of the RCB are presented in Table 3-4. The mass of major equipment is distributed over specific tributary areas where applicable.
The applied loads from which masses are derived for the RCB are:
Structure Self Weight Table 3-2 shows the mass densities used to represent the self weight of the RCB. Additional mass density is added to the CS shell density to account for a 0.25 in. steel liner plate that is compositely attached to the interior face of the CS cylinder and dome. To account for miscellaneous loads such as pipes, tank water and steel liner plates, an additional load of 10 psf is added to exterior walls, and 20 psf is added to all interior walls.
Polar Crane Loads The polar crane load including the main girders (bridge), polar crane ring, trolley, rail, and accessories is approximately 2,500 kips. In addition, the polar crane attachment to the CS by means of steel brackets and steel ring beam weigh 500 kips. In summary, the total weight of the polar crane and its supporting system is approximately 3,000 kips. The polar crane is parked at azimuth 243°.
Water Mass Loads The IRWST water mass is approximately 5,530 kips and is included in the FEM.
Pipe Loads A 50 psf distributed dead load is applied on all RCB slabs to account for pipe loads attached to floor slabs, satisfying the NRC SRP 3.7.2, Part II, 3(D), of the acceptance criteria.
Reactor Coolant System (RCS) Weights The self weight of the RCS supported at various elevations of the RCB is approximately 9,073 kips. This consists of various equipments and their attachments, components such as pipes, pumps, pressurizer, and steam generators.
Roof or Snow Loads The controlling live load on the dome is 75% of 75 psf of snow loads. This load is applied as distributed to the dome (roof) of the CS according to the NRC SRP 3.7.2, Part II, 3(D), in the SRP acceptance criteria.
3.2.6 Modeling of Damping For conservatism, operating basis earthquake (OBE) damping value of 4% for reinforced concrete and 3%
for pre-stressed concrete and welded or bolted steel with friction connections are taken for the uncracked concrete case.
For the cracked concrete case, safe shutdown earthquake (SSE) damping values of 7% for cracked reinforced concrete and 4% for steel connections, as well as 5% for pre-stressed concrete, are used. This criterion is in compliance with NRC Regulatory Guide (RG) 1.61 (Reference 7). A low critical damping ratio of 0.5% is used for sloshing of water per the ASCE 4-98 requirement (Reference 8).
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 9
Non-Proprietary 3.2.7 Modeling of Hydrodynamic Effects for the IRWST The hydrodynamic effect of significant mass interacting with the structure is considered for the IRWST in modeling the inertial characteristics in accordance with Subsection 4.5.4 in the APR1400 design criteria.
Convective and impulsive horizontal masses and frequencies are calculated for modeling the hydrodynamic effects on tank walls.
IRWST Description The IRWST is an enclosed annular cylindrical water tank located inside the RCB at El. 81-0.
Figure 3-8 is an elevation view of the tank, and Figure 3-9 is a plan view of the tank. The tank is made of reinforced concrete and consists of the roof slab, outer (exterior) wall, inner (interior) wall, and bottom slab, which rests on top of the RCB basemat. The inner radius of the outer wall is 71.83 ft, and the outer radius of the inner wall is 53 ft. The top elevation of the IRWST roof slab is 100-0 and the top elevation of the bottom slab is 81-0. The outer and inner walls, roof slab, and bottom slab are all 3 ft thick. The water at the normal operating level is at El. 93-0.
Thus, the water height from the top of the bottom slab to the bottom of the roof slab during normal operation is 12 ft, and the freeboard (water surface to the bottom of the roof slab) is 4 ft.
Hydrodynamic Analytical Approach The analytical approach used to model the horizontal hydrodynamic effect on the annular cylindrical tank is based on the formulations given by Tang et al. (Reference 9), which are based on the previous study of dynamic responses of an annular cylindrical tank under horizontal seismic motion by Aslam et al. (Reference 10). This approach is also presented by R. A. Ibrahim.
The hydrodynamic effects on the rigid tank in the formulation in Reference 9 can be simplified to equivalent mechanical models consisting of impulsive and convective parts similar to those formulated by Housner for cylindrical and rectangular tanks. The impulsive part represents a certain portion of water that moves as a rigid body with the bottom and walls. The convective part represents an oscillating (sloshing) portion of a certain portion of water responding as if it is an oscillating mass flexibly connected to the walls. Using the formulation given in Reference 9, the hydrodynamic properties of equivalent IRWST mechanical models, such as impulsive mass for the impulsive part, and sloshing frequencies and masses for the convective part, can be calculated.
For the vertical vibration, all of the water in the tank is assumed to move vertically as a rigid body with the vertical motion of the tank base. Thus, all of the vertical water mass in the tank is uniformly distributed as lumped masses attached to structural nodes at the bottom of the tank.
Summary of IRWST Hydrodynamic Properties The hydrodynamic properties for impulsive and convective parts are summarized in Table 3-5. In this table, the masses, frequencies, and axial spring stiffnesses of equivalent mechanical models are listed for the impulsive part, and the first two dominant sloshing modes for the convective parts.
The hydrodynamic effects of impulsive and convective parts of water contained in the IRWST are modeled separately by FEM using simplified mechanical models as described below.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 10 Non-Proprietary Impulsive IRWST Models In order to simulate the impulsive forces to exert forces normal to the tank walls during horizontal seismic motion, the horizontal impulsive part of water, which represents the rigid portion of water mass moving with the tank, is modeled as a rigid circular ring-lumped mass, axially rigid radial beams (trusses) system, as shown in Figure 3-10. The impulsive mass given in Table 3-5 is uniformly distributed as lumped masses connected on a rigid circular ring. Each mass has two dynamic degrees of freedoms (DOFs) acting in the horizontal global X and Y directions and is equal to the impulsive mass given in Table 3-5 divided by the number of nodes on the ring.
The rigid circular ring is made of inter-connected rigid beam with large axial and flexural properties to ensure that all impulsive masses move together as one system. The rigid ring is connected to axially flexible radial beams, which are connected to structural nodes on the FEM of the inner-tank wall. The radial beams have a large axial property and very small shear and flexural properties to simulate truss elements so the impulsive forces exert normal to the tank wall.
For the vertical vibration, all of the water in the tank is assumed to move vertically as a rigid body with the vertical motion of the tank base. Thus, the vertical impulsive model consists of lumping all of the water mass attached to FEM structural nodes at the tank base, as shown in Figure 3-12.
Each lumped mass has only one dynamic DOF in the vertical global Z direction, and is equal to the total water mass contained in the tank divided by the number of structural nodes at the tank base.
Convective IRWST Models In order to simulate water loads acting normal to the tank wall, the first two dominant modes of vibration of the convective part of the water in the tank, which represent the oscillating portion of water in the tank, are modeled by two lumped mass radial beam systems, as shown in Figure 3-
- 11. The lumped masses for the first and second modes given in Table 3-5 are placed at the center of the tank. Each lumped mass is then connected to 41 axially flexible radial beams, which are connected to structural nodes on the FEM of the inner tank wall. The water damping ratio of 0.5% for horizontal sloshing modes, as required by ASCE 4-98, Seismic Analysis and Safety-Related Nuclear Structures and Commentary, is used as the damping value for radial beams in the ANSYS FEM.
3.2.8 Modeling of Polar Crane The polar crane is modeled in the FEM. The polar crane is a standard two-girder overhead crane with end trucks at the girder centerlines. The crane is supported by the CS cylindrical shell at El. 241-0. Figure 3-13 shows the details of modeling the polar crane in the ANSYS.
The polar crane system is modeled at its parked location at azimuth 243°. The trolley masses and upper platform are modeled at the bridge girders in the second quarter of span location.
The polar crane model consists of the following:
Two main steel girders are modeled to represent the bridge beams and support the trolley. The bridge wheels have been also modeled to represent the bridge width using rigid beams at all four (4) corners.
The trolley is not modeled. The trolley structure is rigid and spans the two (2) main girders. It is idealized at its parked location by means of two (2) rigid mass less steel cross beams spanning the main girders forming the trolley frame. The trolley mass is accounted for as lumped mass.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 11 Non-Proprietary The ends of the main crane girders are connected with rigid end ties (beams). These beams are tapered but only the typical section is modeled uniformly across the end tie beam length.
Note: +X axis pointing east, at azimuth 270°.
The crane girders and trolley are supported by two (2) steel ring beams. The inner one called the rail ring, has a radius of 71.65 ft from the CS center, while the outer radius is the same as the CS cylindrical radius, which is 77.25 ft.
The inner ring beams are supported at 50 locations by stiff steel corbels or brackets.
The outer steel ring beam is embedded in the concrete CS cylindrical shell and attached to all its shell elements at all the intersection nodes based on the FE mesh discretization.
3.2.9 Modeling of CS The CS is modeled using finite elements given uniform thickness per the structural drawings. All shell elements used to model the CS represent the centerline of the structure walls (i.e., shell elements modeled at their mid-plane). ANSYS SHELL63 elements have both bending and membrane stiffness.
Both in-plane and normal loads are permitted. The element has six degrees of freedom at each node:
translations in the nodal X, Y, and Z directions and rotations about the nodal X, Y, and Z axes.
3.2.10 Modeling of PSW The PSW has two (2) portions: the solid block up to El. 130-0 and the shell shield wall above it to El.
191-0.
The six (6) openings of the hot and cold legs as shown in Figure 3-14, are considered. The penetration of the leg passing through the massive block is idealized, as shown in Figure 3-15, using a rectangular opening of 5 ft x 6 ft.
The interface between shell elements and solid brick elements has been done using rigid beam elements with high axial, bending and shear stiffness to provide continuity at transitions of different element types. See Figures 3-16 and 3-17.
At the RV column supports location, inside the cavity, the diamond shape that provides pads for the column supports is modeled as circular, offering a pad that is approximately 3.2 ft wide. The inner circle diameter (dashed) is approximately 17.6 ft. See Figure 3-18.
3.2.11 Modeling of SSW The SSW is idealized at its centerline as shown in Figure 3-19. The dashed blue lines indicate the idealization of walls and tanks. The dashed red lines indicate the concrete foundation top surface and cavity pit simplifications.
The SSW is modeled with shell elements. At the interface with the concrete base (El. 78-0), there is a massive concrete volume between the PSW and SSW called a pedestal (El. 78-0 to El. 100-0) that is modeled with eight (8) node solid elements. The transition between the solid concrete volume and the cylindrical shell is accomplished by extending the shell elements to overlap with the solid volume below, providing bending stiffness continuity between element types (see Figure 3-20). This transition is better than using rigid beams.
There is a multiple shell element penetration of the SSW inside the concrete basemat that provides stiffness continuity between the SSW shell elements and the solid concrete brick
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 12 Non-Proprietary elements of the base. Mass duplication is avoided by assigning zero density to the penetrating shell elements.
3.2.12 Modeling of RCS Support The degrees of freedom compatibility condition between the beam elements of the RCS and solid elements of the PSW and the SSW is satisfied by using rigid beam elements at the beam-to-wall support points covering the footprint of the RCS support brackets. The RCS supports are modeled as rigid beam elements and connected with other rigid beam elements in the solid elements which represent the PSW and the SSW. Figure 3-21 shows the connection between the RCS supports and the solid elements.
3.2.13 Mesh Sizes for Generation of ANSYS Fine and Coarse 3-D FEM of RCB The 3-D FE models have an adequate number of discrete mass degrees of freedom to capture the global and local translational, rocking, and torsional responses of the structures. The element size is selected so that the structural response is not significantly affected by further size refinement. In general, the fine model mesh size for the CS is 5 ft and for the IS approximately 6 ft. In contrast, the coarse mesh model element size is twice the fine mesh element sizes (i.e., 10 ft to 12 ft).
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 13 Non-Proprietary 4
AUXILIARY BUILDING MODEL This section describes the AB structure and methodology of developing the APR1400 AB FEM.
4.1 Description of AB Structure The APR1400 AB is a safety-related seismic category I structure with an embedment of 53-8 (Reference 11). It encloses the RCB in the center without structural connection except at the common basemat. The combined RCB and AB with a common basemat are generally referred to as the NI structures. Three adjacent structures, the emergency diesel generator building, turbine generator building, and compound building, are separated from the AB with a typical 3 ft building gap. This building layout with adjacent buildings is shown in Figure 4-1. The primary dimensions of the AB are listed in Table 4-1.
The AB houses important facilities including the fuel handling area, spent fuel pool, cask loading pit, refueling canal, cask decontamination pit, auxiliary feed water (AFW) tanks, main control room, equipment hatch access, and others. The AB structural system consists of shear walls in the east-west (E-W) and north-south (N-S) directions and a total of seven (7) major floor and roof slabs. The walls and slabs are made of normal reinforced concrete. Columns and girders are also used to support floor and roof slabs. The shear walls have various sizes of door openings and corridors partial openings on floor slabs.
4.2 Development of Finite Element Models for AB Structure This section describes the development of 3-D AB FEM for SSI analysis. For simplification of the soil layers used in the SSI analysis, the embedment depth of 53-6 is considered in the SASSI model of the AB structure.
4.2.1 Coordinate System A rectangular Cartesian coordinate system is used for the ANSYS and SASSI models. The origin in a horizontal plan of this coordinate system is located at the center of the RCB. In this coordinate system, the positive X points to the plant east direction, the positive Y to the plant north direction, and the positive Z to the vertical upward direction, as shown in Figure 4-2.
4.2.2 Material Properties The major AB structural components are reinforced concrete structures. Material properties of uncracked-concrete for the basemat, slabs, walls, and columns are listed in Table 4-2. Material properties for the horizontal cracked concrete model and vertical cracked concrete model based on the ASCE 43-05 are listed in Tables 4-3 and 4-4, respectively. Material properties of structural steel for columns and for girders are listed in Table 4-5. Critical damping ratios are taken from NRC RG 1.61.
4.2.3 Common Basemat for AB and RCB The 10 ft thick basemat, as shown in Figure 4-3 serves as a common foundation for the AB and RCB. In the basemat, the central circular area with a radius of 83-6 serves as the RCB foundation, while the rest of the basemat supports the AB with an embedment of 53-6. The two buildings are separated with a minimum 6 in. seismic gap above the top surface of the common basemat at El. 55-0.
The AB and RCB common basemat is modeled separately in the ANSYS by four (4)-node elastic SHELL63 elements for the AB at the bottom surface of the concrete foundation (El. 45-0) to account more closely for SSI effects and by eight (8)-node SOLID45 elements for the RCB concrete foundation, as shown in Figure 4-4 for the coarse mesh. To provide continuation of rotational deformation at the
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 14 Non-Proprietary interface of AB shell elements and RCB solid elements, a dummy massless ring of shell elements is extended from the edge to inside the RCB, beneath the solid elements as depicted in Figures 4-5 and 4-6.
The ANSYS elastic SHELL63 element has both bending and membrane capabilities. Both in-plane and normal loads are permitted. The element has six degrees of freedom at each node, three translations, and three rotations.
To simulate the relatively rigid 10 ft basemat between the top (El. 55-0) and bottom (El. 45-0) surfaces of the concrete foundation, AB walls and columns are extended from El. 55-0 to El. 45-0 with massless rigid beam elements. A mesh size of 5 ft for the basemat is specified for the ANSYS fine model, while for the ANSYS coarse model a larger size of 12 ft is set to equal that determined from the requirement for soil mesh sizes limited to one-fifth of the wave length at the 50 Hz cut-off frequency. Figures 4-5 and 4-6 depict the AB basemat geometry of the ANSYS fine and coarse models, respectively.
4.2.4 Shear Walls, Partial Wall Openings (Doors, Corridors, and Others), Equivalent Wall Thicknesses and Equivalent Mass Densities The AB shear wall system is a normal reinforced concrete structure with thicknesses varying from 4 ft to 1.5 ft at the top. For several special local areas, some walls with a thickness of 5 to 7 ft are used for the Spent Fuel Pool. Bearing walls and local minor walls that are not part of the shear wall system are not included in the model. However, the masses of these walls are included in the concentrated masses.
Shear walls contain various sizes of openings, such as single doors, double doors, and corridors. To simplify the 3-D FEM, these openings are not modeled, but the effects of the openings on the shear stiffness of the wall panels are included by using an equivalent wall thickness with the stiffness factors obtained from a parametric study.
An additional 10 psf is included on each interior wall face to account for the miscellaneous dead loads attached to the walls. With the equivalent shear stiffness factors, equivalent thicknesses and mass densities of shear walls are calculated. Shear walls are modeled with the ANSYS four (4)-node SHELL63 elements.
4.2.5 Floor Slabs, Partial Floor Openings, Major Equipment, Earthquake Live Loads, Roof Snow Loads, Other Miscellaneous Dead Loads, and Equivalent Mass Densities The AB structural model comprises one basemat (El. 55-0), seven major floor and roof slabs (El. 78-0, 100-0, 120-0, 137-6, 156-0, 174-0, and 195-0), and four minor partial floor and roof slabs (El. 68-0, 213-0, 213-6, 216-9). The basemat and its supported equipment are modeled at El. 45-0. Floors at El. 68-0 and 78-0 are modeled with a small adjustment made to shift the centerlines of the floor slabs at El. 67-0 and 77-0, respectively, to align with the soil layer elevations in the SSI model.
Floor slabs have some partial openings, which are included in the model geometry.
Major APR1400 AB equipment loads are listed in Table 4-6, while seismic live loads, roof dead loads, roof snow loads, and other miscellaneous dead loads are given in Table 4-7.
In addition to the floor loads, the weight of floor construction steel beams used to temporarily support the concrete weight before curing is included to calculate the total equivalent mass densities for floor slabs.
Floor slabs are modeled with the ANSYS four (4)-node SHELL63 elements.
4.2.6 Modeling for Out-of-Plane Vertical Flexibility of Floor Slabs To develop a coarse ANSYS 3-D AB FEM, a step is needed to verify the accuracy of the coarse model by using a fine model with a smaller mesh size. This is particularly important for the out-of-plane vertical
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 15 Non-Proprietary flexibility of floor slabs. A study is conducted to identify any property adjustments that are needed in floor panels in the coarse model to obtain the same flexibility as those for the fine model.
In the study, the ANSYS fine and coarse 3-D AB FEMs are cut at the upper and lower floors for a floor in the study. Fixed boundary conditions are specified at all nodes of the cut planes. ANSYS modal analyses of selected floor slabs are performed for both separated models. Comparisons of fundamental frequencies for these floor slabs are made panel by panel. If the fundamental frequency of the fine isolated model is lower than 50 Hz and is 5% greater than that of the coarse isolated model, the modulus of elasticity of the panel in the coarse model is adjusted by:
Em = E (Ff/Fc)2 Where Em= Adjusted modulus of elasticity of concrete for the panel of the coarse model under study E = Modulus of elasticity of concrete for the panel under study Ff = Fundamental out-of-plane vertical frequency of the panel in the fine model Fc = Fundamental out-of-plane vertical frequency of the panel in the coarse model before adjustment The results of the study are summarized in Table 4-8.
4.2.7 Modeling for Columns and Girders Columns and girders in the AB are modeled with beam elements. Most columns are embedded in walls with a few exceptions. Those columns are added to the model with its center line modeled at the center line location of the wall which is modeled by shell elements.
With the concrete section already presented in the shell element the for floor slab, the girder is modeled at the centerline of the shell element.
4.2.8 Concentrated Masses for Minor Structural Components Not Modeled Minor structural components such as local bearing walls, small local slabs, and parapets are not modeled, but these masses are lumped at supporting shear walls.
4.2.9 Modeling of Hydrodynamic Loads for AFW and FHA Tanks There are six (6) AFW tanks on the ground floor at El. 100-0, one spent fuel pool at El. 114-0, one cask loading pit at El. 111-0, and one refuel canal at El. 114-6. The hydrodynamic effects from these water tanks are included with horizontal hydrodynamic mass and support stiffness to simulate horizontal sloshing (convective) masses of water attached with flexible springs to the upper portion of the tank wall.
Horizontal impulsive hydrodynamic mass is calculated as lumped masses attached rigidly to the lower portion of the tank wall. The hydrodynamic effects on two horizontal (E-W & N-S) directions are considered separately. In the vertical direction, the total water mass is lumped at the bottom slab of the tank.
4.2.10 Mesh Sizes for Generation of ANSYS Fine and Coarse 3-D AB FEM Because the thickness of shear walls generally varies from 3 to 4 ft, the mesh size for an ANSYS fine 3-D FEM also should not be less than 4 ft. With other considerations for structural modeling, a mesh size of 5
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 16 Non-Proprietary ft is selected for the ANSYS fine 3-D FEM. The 5 ft mesh fine model, by estimation, exceeds the model size limits for the ACS SASSI (Reference 12) program. The fine model can, however, be considered as a base model for verification of a coarse model. The coarse model can be used for seismic SSI analysis to satisfy (1) the 12 ft mesh size requirement for a 50 Hz cut-off frequency and (2) the model size requirement of the ACS SASSI program. Accordingly, a mesh size of 12 ft is determined to be adequate for use in the ANSYS coarse 3-D AB FEM.
4.2.11 Geometry Plots of ANSYS Fine and Coarse 3-D AB FEM The ANSYS fine and coarse 3-D AB FEMs are created. Table 4-9 summarizes the two FEMs.
Figure 4-7 depicts the ANSYS fine 3-D AB FEM, while Figure 4-8 depicts ANSYS coarse 3-D AB FEM.
Figure 4-9 shows a view looking north into the interior modeling with a vertical cut at column line AG (to avoid blocking by the wall at column line AF). Figure 4-10 is another view looking east into the interior modeling, with a vertical cut at column line 19.
4.2.12 Minimum Frequency of Seismic Wave Passage For subgrade portions of the structure, the mesh size is controlled by the soil thickness, which is required to satisfy the minimum frequency. A cut-off frequency of 50 Hz is used for seismic wave passage through rock and hard and moderate soil profiles. Cut-off frequencies between 20 and 40 Hz are used for soft soil profiles.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 17 Non-Proprietary 5
VERIFICATION OF SEISMIC MODEL 5.1 Verification of RCB Model To verify the RCB seismic analysis model to be used in the SSI analysis, the following comparisons with the fine 3-D FEM are performed under the fixed-base condition.
Modal properties Static displacements of 1g ISRS using time history analysis 5.1.1 Comparison of Modal Analysis Results The modal solution is required because the structure's mode shapes and frequencies must be available for comparison between the fine mesh and coarse mesh models. Modal analysis is used to determine the natural frequencies and mode shapes of a structure. The natural frequencies and mode shapes are important parameters in the design of a structure for dynamic loading conditions and are required to perform a transient time history analysis.
Consequently, to verify dynamic properties of the developed ANSYS models, modal analyses of the ANSYS fixed-base coarse and fine mesh models are performed.
Figures 5-1 through 5-3 compare the major natural frequencies in all three directions (X, Y, and Z) and cumulative modal participation mass ratios. Figures 5-4 through 5-8 present the mode shapes and Tables 5-1 and 5-2 show the fundamental major frequencies and their mass participation factors.
5.1.2 Comparisons of Static Displacements In this subsection, unit acceleration (1g) is applied in each of the three directions to the coarse and fine FEMs in order to validate the stiffness of the RCB coarse FEM. Several nodes are selected along the height of the RCB and the displacements due to unit acceleration are compared for both models.
Different nodes are selected at the CS, PSW, and SSW structures. The approximate locations of such nodes in the plan view are shown in Figures 5-9 through 5-11. The displacements are shown in Figures 5-12 through 5-20.
5.1.3 Comparisons of ISRS The dynamic response for the coarse ANSYS fixed-base FEM and the corresponding response in the ANSYS fine model are compared via uni-directional ISRS at different locations. The selected nodes and their coordinates are shown in Subsection 5.1.2.
A 5% spectral damping value is used for the comparison. The frequency interval used for ISRS development follows SRP Section 3.7.2. Figures 5-21 through 5-29 show ISRS plots of the ANSYS coarse model versus ANSYS fine model.
Once the RCB seismic analysis model is verified, the ANSYS coarse FEM is converted to SASSI and the validation is repeated at this level to ensure that the conversion is done properly.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 18 Non-Proprietary 5.1.4 SASSI Model Validation The dynamic response for the coarse ANSYS fixed-base FEM and the corresponding response in the SASSI model are compared via ISRS at different locations. The selected nodes and their coordinates are shown in Subsection 5.1.2.
A 5% spectral damping value is used for the comparison. The frequency interval used for ISRS development follows SRP Section 3.7.2. Figures 5-30 through 5-38 show ISRS plots of the ANSYS coarse FEM versus SASSI FEM.
5.2 Verification of AB Model To verify the AB seismic analysis model, modal properties, static displacements, and ISRS are compared.
5.2.1 Comparison of Modal Analysis Results Modal analyses are performed for the two ANSYS models to obtain a total of 2,500 modes by using the ANSYS Lanczos iteration option.
Tables 5-3 through 5-5 are comparisons of the major modal frequencies and masses for the dominant modes computed from the fine and coarse ANSYS models for the X, Y, and Z directions, respectively.
The frequencies are sorted by the descending order of the modal masses.
Tables 5-3 and 5-4 show a reasonable agreement between the fine and coarse models for the two horizontal directions. The comparison for the vertical direction in Table 5-5 shows a larger difference in frequency for relatively close values of modal mass. The difference is reasonably expected because of differences in the modeling of floor slabs between the two models. The coarse model used in this verification lacked the vertical out-of-plane flexibility adjustment.
Figures 5-39 to 5-41 are comparisons of cumulative mass ratios between the fine and coarse models for X, Y, and Z directions, respectively. The three cumulative mass ratios of the two models compare well.
The comparisons of modal properties also indicate that AB horizontal dominant frequencies are 5.15 Hz and 5.34 Hz in the E-W and N-S directions, respectively. The dominant vertical frequency is 14.5 Hz.
The computation of these modal masses does not include a rigid body mode. Therefore, a large percentage of total mass is not accounted for in the cumulative masses, in the two horizontal directions, and in the vertical direction.
5.2.2 Comparisons of Static Displacements Static analyses for 1g gravity loads are performed by applying a 1g-acceleration in each of the three directions separately to both ANSYS fine fixed-base and ANSYS coarse models using the ANSYS program.
Static displacements obtained from both ANSYS fine and coarse models at selected locations of four building corners are plotted in Figures 5-42 through 5-45. Comparisons of the static displacement results between the two ANSYS models show good agreement.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 19 Non-Proprietary 5.2.3 Comparisons of ISRS between ANSYS Fine, ANSYS Coarse, and SASSI Fixed-base Models Two model verifications are presented in this subsection. The first is verification of the ANSYS coarse fixed-base model against the ANSYS fine fixed-base model and the second is verification of the SASSI fixed-base model against the ANSYS coarse fixed-base model.
ISRS of 4% damping for selected locations of the three fixed-base AB models are shown in Figures 5-46 through 5-65.
The ISRS figures indicate that the ANSYS coarse fixed-base model compares well with the ANSYS fine fixed-base model. The SASSI model also compares well with the ANSYS coarse fixed-base model.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 20 Non-Proprietary 6
COMBINED NI SASSI MODEL The combined NI SASSI model for the APR1400 SSI analysis consists of the RCB and AB. These two buildings are founded on a common foundation basemat. Above the basemat, the two buildings are separate and to not have structural connections. In the plant layout, the AB is separated by 3 ft gaps from the emergency diesel generator building, the turbine generator building, and the compound building.
6.1 Modeling of Structural Components of Combined NI Models of RCB and AB structural components are first created in the ANSYS and then converted to SASSI. A total of 32,778 nodes are created (23,524 structural nodes and 9,254 soil interaction nodes),
and a total of 59,030 elements are generated (including 35,113 solid elements, 4,037 beam elements, 17,974 shell elements, and 1,906 spring elements). A total of 1,452 concentrated masses are included in the model.
At the junction of shell and solid elements, massless shell elements are used to extend shell elements into solid elements for a finite distance to make the shell rotational deformation at the junction continuous with solid elements. Figure 6-1 shows the structural model of the SASSI 3-D FEM for the combined NI structures.
6.2 Common Foundation Basemat The common foundation basemat is a 10 ft thick slab at an embedment of 53.5 ft at its bottom surface.
The basemat is modeled by shell elements at its bottom surface (El. 45-0). With rigid properties and massless densities, structural walls and columns are extended vertically from the top surface (El. 55-0) of the basemat to connect to the shell elements at the bottom surface.
6.3 Soil Excavation A soil excavation model is created with the dimensions of the AB plus extensions in two horizontal directions as well as vertically downward for soil and lean concrete backfill. A total of 9,254 interaction nodes are created with the Flexible Volume Method for this model. A mesh size of 12 ft is used for an average cut-off frequency of 50 Hz among the eight (8) soil profiles for the upper 98.5 ft of soil layers. The SASSI 3-D FEM of the excavated soil volume for the combined NI structure foundation is shown in Figure 6-2.
6.4 Bottom Lean Concrete and Side Soil Backfilled with SFG An extra 3 ft deep excavation beneath the bottom concrete surface of the basemat is used for the lean concrete backfill. An extra side excavation varies from 12 ft wide at the bottom to 24 ft wide at the top of the soil and 3 ft wide backfill between adjacent buildings. The extra side soil excavations are backfilled with structural fill granular (SFG). The SASSI 3-D FEM of the SFG and lean concrete backfill, which are modeled using solid elements, for combined NI structures is shown in Figure 6-3.
6.5 Connections between Structural Concrete and Soil The SASSI model has two sets of nodes at the soil-structure interface boundary. One set consists of structural concrete nodes for external walls and basemat, and the other set consists of soil interaction nodes for soil excavation and soil backfill. The two sets of nodes are coincident nodes at the same locations, and are connected by a set of rigid spring elements. With this rigid spring connection, the concrete foundation is connected to the free-field soil. The SASSI 3-D FEM of the combined NI structures with soil backfill solid elements is shown in Figure 6-4.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 21 Non-Proprietary 7
REFERENCES
- 1.
Computer Program, ANSYS, User Manual Version 14.0, ANSYS, Inc., October 2011.
- 2.
J. Lysmer, et al., SASSI - A System for Analysis of Soil-Structure Interaction, Report No.
UCB/GT/81-02, Department of Civil Engineering, University of California, Berkeley, April 1981.
- 3.
APR1400 General Arrangement Drawings, Reactor Containment Building, Rev. 1, KEPCO Engineering & Construction Company, Inc. and KHNP, November 2011.
- 4.
ASCE 43-05, Seismic Design Criteria for Structures, Systems, and Components in Nuclear Facilities, American Society of Civil Engineer, 2005.
- 5.
APR1400 Document No. 1-037-B401-001, Design Criteria Manual, Chapter 4 - Structural Design Criteria, Rev. 1, KEPCO Engineering & Construction Company, Inc. and KHNP, September 2012.
- 6.
NUREG-0800, Standard Review Plan, Section 3.7.2, Seismic System Analysis, Rev. 4, U.S.
Nuclear Regulatory Commission, September 2013.
- 7.
Regulatory Guide 1.61, Damping Values for Seismic Design of Nuclear Power Plants, Rev. 1, U.S. Nuclear Regulatory Commission, March 2007.
- 8.
ASCE 4-98, Seismic Analysis of Safety-Related Nuclear Structures and Commentary, American Society of Civil Engineer, 1998.
- 9.
Yu Tang, C. Grandy, and R. Seidensticker, Seismic Response of Annular Cylindrical Tanks, Nuclear Engineering and Design, Vol. 240, pp. 2614 - 2625, 2010.
- 10.
M. Aslam, W. G. Godden, and D. T. Scalise, Earthquake Sloshing in Annular and cylindrical Tanks, Journal of Engineering Mechanics Division, American Society of Civil Engineer, June 1979.
- 11.
APR1400 General Arrangement Drawings, Auxiliary Building, Rev. 0, KEPCO Engineering &
Construction Company, Inc. and KHNP, November 2011.
- 12.
Computer Program ACS SASSI, NQA V.2.3.0, Including Option A and FS, Ghiocel Predictive Technologies, Inc. (GPT), September 2012.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 22 Non-Proprietary Table 2-1 Maximum Frequency of Seismic Wave Propagation Soil Case Vs (ft/sec) Averaged from a Depth of 30 m Soil Layer Thickness (ft)
Max Frequency (Hz) of Seismic Wave Propagation=Vs/(5H) 1 1191 11 21.7 2
995 11 18.1 3
2188 11 39.8 4
1866 11 33.9 6
3239 11 58.9 7
2801 11 50.9 8
6528 11 118.7 9
4796 11 87.2
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 23 Non-Proprietary Table 3-1 Summary of the Main Dimensions of RCB Item Dimensions (ft)
Nominal ground elevation 100.00 Nominal basement bottom elevation 45.00 Foundation thickness under CS and IS 11.00 / 33.00 Top elevation of CS dome center line 331.38 Center line radius of CS 77.25 Outer radius of IS foundation at El. 78-0 83.50 Wall thickness of CS cylinder 4.50 Wall thickness of CS dome 4.00 CS Buttress wall thickness 7.50 IS - PSW thickness 4.00 / 12.17 IS - SSW thickness 4.00
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 24 Non-Proprietary Table 3-2 Material Properties for Concrete and Steel Structural Component Concrete Compressive Strength or Steel Yield Limit (psi)
Unit Weight (kcf)
Youngs Modulus (105 ksf)
Poissons Ratio Damping (OBE)
Damping (SSE)
CS 6,000 0.15 6.36 0.17 3%
5%
PSW & SSW 6,000 0.15 6.36 0.17 4%
7%
Base /Pedestal 5,000 0.15 5.80 0.17 4%
7%
Steel A588,Grade A (AISC),fy=50ksi 0.49 41.76 0.30 3%
4%
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 25 Non-Proprietary Table 3-3 Effective Cracked-Concrete Modulus of Elasticity Member Type Cracked Concrete Modulus of Elasticity (
c E
)
Horizontal Model Vertical Model Prestressed concrete containment structure 0.5 Ec Ec Reinforced concrete columns and walls 0.5 Ec Ec Reinforced concrete beams and slabs 0.5 Ec 0.5 Ec Reinforced concrete basemat 0.5 Ec 0.5 Ec
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 26 Non-Proprietary Table 3-4 Seismic Live Load, Roof Snow Load, and Miscellaneous Dead Load Floor Loads Value (psf)
Miscellaneous dead load (minor equipment, piping, raceways, NRC SRP 3.7.2) 50.00 Seismic live load1) (25% of floor design load 200 psf, NRC SRP 3.7.2)
Not Applied Roof snow load (75% of roof design snow load 75 psf, NRC SRP 3.7.2) 56.25 Notes
- 1) The seismic live load is not considered for floors in the seismic analysis model of the RCB because the effect of seismic live load on the RCB seismic response has been shown by analysis to be negligibly small.
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 27 Non-Proprietary Table 3-5 Hydrodynamic Properties for Equivalent Mechanic Models In-containment Refueling Water Storage Tank Hydrodynamic Component Mode Kn1)
Mn2)
Wn3) n4) fn5) hn6) n7)
(lb/ft)
(lb-sec2/ft)
(lb)
(rad/sec)
(Hz)
(ft)
Impulsive rigid rigid 5.769E+04 1.858E+06 very high very high 5.2 Convective (Sloshing) 1 8,569 8.664E+04 2.790E+06 0.31 0.050 6.0 2
144,500 2.647E+04 8.523E+05 2.34 0.372 7.5 Notes
- 1) Kn = Axial spring stiffness for mode n
- 2) Mn = Hydrodynamic mass for mode n
- 3) Wn = Hydrodynamic weight for mode n
- 4) n = Sloshing frequency in radian/second for mode n
- 5) fn = Sloshing frequency in Hertz (Hz) or cycle/second (cps) for mode n
- 6) hn = Height of impulsive or sloshing mass ( Mn ) from the bottom of the tank at El. 81-0 for mode n
- 7) n = Mode number
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 28 Non-Proprietary Table 4-1 Main Dimensions of AB Structure Security-Related Information - Withhold Under 10 CFR 2.390 TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 29 Non-Proprietary Table 4-2 Material Properties of Uncracked-Concrete Structural component Unit Weight (pcf)
Compressive Strength (psi)
Modulus of Elasticity (ksf)
Poissons Ratio Critical Damping Ratio, SSE
(%)
Critical Damping Ratio, OBE
(%)
Basemat 150 5000 580,393 0.17 4.0 Floor slabs 150 5000 580,393 0.17 4.0 Walls 150 5000 580,393 0.17 4.0 Columns 150 5000 580,393 0.17 4.0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 30 Non-Proprietary Table 4-3 Material Properties of Horizontal Cracked-Concrete Model Structural Component Unit Weight (pcf)
Compressive Strength (psi)
Modulus of Elasticity (ksf)
Poissons Ratio Critical Damping Ratio, SSE
(%)
Critical Damping Ratio, OBE
(%)
Basemat 150 5000 290,197 0.17 7.0 Floor slabs 150 5000 290,197 0.17 7.0 Walls 150 5000 290,197 0.17 7.0 Columns 150 5000 290,197 0.17 7.0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 31 Non-Proprietary Table 4-4 Material Properties of Vertical Cracked-Concrete Model Structural Component Unit Weight (pcf)
Compressive Strength (psi)
Modulus of Elasticity (ksf)
Poissons Ratio Critical Damping Ratio, SSE
(%)
Critical Damping Ratio, OBE
(%)
Basemat 150 5000 290,197 0.17 7.0 Floor slabs 150 5000 290,197 0.17 7.0 Walls 150 5000 580,393 0.17 4.0 Columns 150 5000 580,393 0.17 4.0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 32 Non-Proprietary Table 4-5 Material Properties of Structural Steel Material Unit Weight (pcf)
Yield Strength (ksi)
Modulus of Elasticity (ksf)
Poissons Ratio Critical Damping Ratio, SSE
(%)
Critical Damping Ratio, OBE
(%)
Steel column ASTM A572 490 50 4,176,000 0.30 4.0 3.0 Steel girder ASTM A36 490 36 4,176,000 0.30 4.0 3.0 Steel angles ASTM A36 490 36 4,176,000 0.30 4.0 3.0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 33 Non-Proprietary Table 4-6 Major Equipment Loads Equipment Designation Equipment No.
Location by Column Lines Floor Elevation (ft)
Weight (kips)
CS heat exchangers M2102, M2103 AA-AB-13-15, AJ-AK-13-15 55-0 73.6 Seismic category I fire water tanks M2104, M2105 AE-AF-12-13, AF-AG-12-13 55-0 234.5 SC heat exchangers M2126, M2127 AA-AB-23-25, AJ-AK-23-25 55-0 87.4 Equipment drain tank M2138 AG-AH-25-26 55-0 115.0 Diesel fuel oil storage tanks M2233, M2234
/A-AA-13-15,
/K-AK-13-15 68-0 1065.0 Boric acid concentrator M2228 AF-AG-25-26 78-0 61.0 Class 1E emergency diesel generator M2302, M2303 AB-AC-13-14, AI-AJ-13-14 100-0 400.1 SG blowdown flash tank M2401 AB-AC-21-22 120-0 192.0 AB controlled area I exhaust ACUs H2405 AB-AC-24-26 120-0 73.3 AB controlled area II exhaust ACUs H2406 AG-AH-25-26 120-0 73.3 Spent fuel handling machine AF-AI-23-25 156-0 53.3 AB controlled area I normal exhaust ACUs H2615, H26166 AA-AB-21-22, AA-AB-24-25 156-0 73.3 CCW surge tanks M2701, M2702 AA-AB-13-14, AJ-AK-13-14 174-0 86.0 Fuel handling area overhead crane M2801 AC-AD-15-16 195-0 276.9 AB controlled area II normal exhaust ACUs H2808, H2809 AJ-AK-20-22, AG-AI-22-23 195-0 73.3
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 34 Non-Proprietary Table 4-7 Seismic Live Load, Roof Dead Loads, Roof Snow Loads, and Other Miscellaneous Dead Loads Floor Loads Value (psf)
Miscellaneous dead load (minor equipment, piping, raceways, NRC SRP 3.7.2) 50.00 Seismic live load (25% of floor design load 200 psf, NRC SRP 3.7.2) 50.00 Roof snow load (75% of roof design snow load 75 psf, NRC SRP 3.7.2) 56.25 Roofing material dead load 50.00 Raised floor (at El. 157-9 ) for floor El. 156-0 only 20.00
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 35 Non-Proprietary Table 4-8 Out-of-Plane Vertical Floor Flexibility Adjustment Factors for the Coarse Model Panel Elevation (ft)
Panel Location Fine Model Frequency (Hz)
Coarse Model Frequency (Hz)
Percent Difference (Coarse/
Fine-1)
Em Adjustment Factor (Ff/Fc)2 100 15-19-AA-AB 32.3 30.4
-5.9%
1.13 100 15-19-AJ-AK 32.3 30.4
-5.9%
1.13 100 17-19-AB-AC 32.3 30.4
-5.9%
1.13 100 17-19-AI-AJ 32.3 30.4
-5.9%
1.13 120 AB-AC-24-25 20.7 19.6
-5.42%
1.12 120 AB-AC-25-26 20.7 19.6
-5.42%
1.12 120 AH-AI-22-23 33.3 31.1
-6.58%
1.15 120 AI-AJ-24-25 25.4 23.8
-6.29%
1.14 120 AI-AJ-25-26 25.4 23.8
-6.29%
1.14 120
/1)-AA-12-13 32.2 30.1
-6.37%
1.14 120 AK-/-12-13 32.2 30.1
-6.37%
1.14 174 17-18-AA-AB 39.9 37.7
-5.51%
1.12 174 17-18-AJ-AK 39.9 37.8
-5.26%
1.11 Notes
- 1) Refer to Figure 4-5
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 36 Non-Proprietary Table 4-9 Summary of ANSYS Fine and Coarse 3-D FEMs of AB Element Type ANSYS Fine 3-D FEM ANSYS Coarse 3-D FEM Total number of nodes 59,567 11,682 Number of (4-node elastic shell)
SHELL63 elements 64,727 14,075 Number of (2-node 3-D elastic beam)
Beam4 elements 363 298 Number of (2-node 3-D elastic tapered beam)
Beam44 elements 1,561 1,561 Number of (structural mass)
MASS21 elements 4,040 1,811 Total number of elements 70,691 17,745
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 37 Non-Proprietary Table 5-1 Containment Structure, Major Modes Comparison Fine vs Coarse Mesh Models ANSYS Coarse Model ANSYS Fine Model Direction Major Modes Natural Frequency (Hz)
Mass Ratio Major Modes Natural Frequency (Hz)
Mass Ratio 11 3.49 18.2%
12 3.47 17.9%
X (E-W) 12 3.58 15.7%
13 3.56 15.4%
Y (N-S) 30 10.60 22.5%
33 10.55 24.5%
Z (Vertical) 98 19.55 1.1%
100 19.36 1.3%
Drumming
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 38 Non-Proprietary Table 5-2 Internal Structure, Major Modes Comparison Fine vs Coarse Mesh Models ANSYS Coarse Model ANSYS Fine Model Direction Major Modes Natural Frequency (Hz)
Mass Ratio Major Modes Natural Frequency (Hz)
Mass Ratio 18 6.27 4.1%
20 6.10 6.7%
Y (N-S) 28 9.72 6.1%
30 9.46 3.5%
X (E-W) 25 8.61 1.5%
27 8.56 1.7%
Y (N-S) 29 9.93 5.1%
32 9.69 7.5%
X (E-W) 132 23.41 8.0%
133 23.29 15.3%
Z (Vertical)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 39 Non-Proprietary Table 5-3 AB, Comparisons of Major Modal Frequencies in X-Direction ANSYS Coarse Model - X Direction ANSYS Fine Model - X Direction Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/Total Mass Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/Total Mass 75 5.1615 4380.18 1.85E-01 83 5.1422 4329.44 1.82E-01 81 5.7866 3298.40 1.39E-01 84 5.3331 2618.86 1.10E-01 76 5.3540 2536.01 1.07E-01 86 5.8235 2327.47 9.81E-02 101 10.4132 852.88 3.59E-02 85 5.6118 1042.00 4.39E-02 83 6.0871 794.33 3.35E-02 108 10.3591 1024.45 4.32E-02 95 9.0481 664.07 2.80E-02 90 6.0532 821.32 3.46E-02 102 10.5368 472.42 1.99E-02 101 9.0229 605.14 2.55E-02 82 5.9465 318.15 1.34E-02 109 10.4470 217.00 9.15E-03 96 9.3992 247.97 1.05E-02 104 9.3449 214.77 9.05E-03 86 7.3622 159.92 6.74E-03 94 7.3418 142.62 6.01E-03 262 17.3913 119.93 5.05E-03 135 12.1773 140.46 5.92E-03 132 12.2365 84.78 3.57E-03 114 10.5961 136.57 5.76E-03 128 12.0956 67.18 2.83E-03 88 5.9280 122.94 5.18E-03 265 17.5444 65.96 2.78E-03 208 15.1332 101.00 4.26E-03 146 12.8488 62.82 2.65E-03 138 12.3280 88.98 3.75E-03 114 11.3754 57.10 2.41E-03 179 13.8898 78.31 3.30E-03 98 10.1057 54.78 2.31E-03 277 17.6932 74.51 3.14E-03 136 12.3930 53.92 2.27E-03 137 12.2951 74.29 3.13E-03 100 10.2244 53.56 2.26E-03 265 17.3568 71.90 3.03E-03 197 15.1207 52.09 2.20E-03 89 5.9493 71.05 2.99E-03
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 40 Non-Proprietary Table 5-4 AB, Comparisons of Major Modal Frequencies in Y-Direction ANSYS Coarse Model - Y Direction ANSYS Fine Model - Y Direction Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/
Total Mass Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/
Total Mass 76 5.3540 8908.01 3.75E-01 84 5.3331 8868.26 3.74E-01 75 5.1615 2922.03 1.23E-01 83 5.1422 2926.52 1.23E-01 108 11.2251 680.65 2.87E-02 119 11.1741 568.77 2.40E-02 101 10.4132 597.83 2.52E-02 108 10.3591 532.98 2.25E-02 95 9.0481 334.43 1.41E-02 99 8.8976 288.01 1.21E-02 118 11.6001 301.21 1.27E-02 86 5.8235 268.15 1.13E-02 81 5.7866 273.55 1.15E-02 104 9.3449 239.43 1.01E-02 96 9.3992 217.15 9.15E-03 125 11.5958 200.70 8.46E-03 94 8.9176 130.28 5.49E-03 109 10.4470 193.91 8.17E-03 88 7.8877 123.11 5.19E-03 124 11.5196 180.74 7.62E-03 102 10.5368 109.24 4.60E-03 101 9.0229 155.87 6.57E-03 82 5.9465 93.72 3.95E-03 121 11.2394 153.33 6.46E-03 132 12.2365 80.29 3.38E-03 85 5.6118 152.39 6.42E-03 121 11.7667 74.13 3.12E-03 137 12.2951 99.98 4.21E-03 325 19.0354 63.28 2.67E-03 96 7.8568 98.33 4.14E-03 137 12.4201 62.80 2.65E-03 123 11.4613 81.89 3.45E-03 112 11.3204 59.27 2.50E-03 326 19.0270 79.66 3.36E-03 221 16.2480 56.61 2.39E-03 138 12.3280 63.86 2.69E-03 79 5.6955 48.11 2.03E-03 95 7.7242 59.47 2.51E-03 87 7.7353 47.28 1.99E-03 454 22.0540 50.72 2.14E-03
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 41 Non-Proprietary Table 5-5 AB, Comparisons of Major Modal Frequencies in Z-Direction ANSYS Coarse Model - Z Direction ANSYS Fine Model - Z Direction Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/
Total Mass Mode Frequency (Hz)
Modal Mass (k-s2/ft)
Ratio of Modal Mass/
Total Mass 171 14.5161 1002.32 4.22E-02 195 14.5999 1879.21 7.92E-02 140 12.6490 909.49 3.83E-02 124 11.5196 1565.47 6.60E-02 160 13.8459 744.37 3.14E-02 179 13.8898 895.30 3.77E-02 98 10.1057 674.52 2.84E-02 187 14.3157 574.46 2.42E-02 118 11.6001 626.86 2.64E-02 106 10.0230 545.46 2.30E-02 189 14.8251 613.38 2.59E-02 151 12.6794 496.42 2.09E-02 115 11.4160 588.05 2.48E-02 135 12.1773 482.49 2.03E-02 146 12.8488 549.38 2.32E-02 217 15.4950 466.21 1.96E-02 116 11.5104 391.75 1.65E-02 212 15.2913 410.10 1.73E-02 128 12.0956 385.22 1.62E-02 123 11.4613 318.45 1.34E-02 156 13.6659 372.74 1.57E-02 154 12.9322 311.98 1.31E-02 172 14.5338 334.65 1.41E-02 133 12.0369 290.64 1.22E-02 193 15.0402 267.94 1.13E-02 149 12.5765 281.79 1.19E-02 213 15.7221 249.18 1.05E-02 152 12.8446 264.70 1.12E-02 191 14.9820 247.46 1.04E-02 137 12.2951 213.40 8.99E-03 165 14.0172 205.62 8.67E-03 173 13.4896 158.76 6.69E-03 203 15.2950 200.69 8.46E-03 243 16.7113 136.96 5.77E-03 161 13.8857 188.54 7.95E-03 119 11.1741 136.53 5.75E-03 208 15.4281 182.84 7.71E-03 176 13.6724 135.62 5.72E-03 124 11.9398 174.28 7.34E-03 178 13.7701 134.57 5.67E-03
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 42 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-1 Containment Structure Overview - Fine Mesh Model (Y points to Plant North)
TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 43 Non-Proprietary Figure 3-2 Plan View of Rectangular Concrete Massive Block of Primary Shield Wall
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 44 Non-Proprietary Figure 3-3 Isometric View of Primary Shield Wall and Concrete Pedestal West PSW SHELL PSW SOLID PEDESTAL (El. 78 100-0)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 45 Non-Proprietary TS Figure 3-4 Reactor Coolant System Overview
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 46 Non-Proprietary Figure 3-5 Concrete Cylindrical Volume (167 ft Diameter) with RV Pit Inside
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 47 Non-Proprietary Figure 3-6 Isometric View of Internal Structure
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 48 Non-Proprietary Figure 3-7 Rectangular Cartesian Coordinate System of RCB
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 49 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-8 Elevation View of Reactor Containment Building Showing Typical Section of IRWST TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 50 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-9 Plan View of IRWST at El. 81-0 TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 51 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-10 Plan View of Equivalent Mechanical Horizontal Impulsive Model of Tank-Water System for IRWST TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 52 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-11 Plan View of Equivalent Mechanical Horizontal Convective Models of Tank-Water System for IRWST TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 53 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-12 Section View of Reactor Containment Building Showing Hydrodynamic Impulsive and Convective Models of Tank-Water System for IRWST TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 54 Non-Proprietary Figure 3-13 Polar Crane ANSYS Modeling
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 55 Non-Proprietary Figure 3-14 Hot and Cold Legs Openings (Typical Cross Section)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 56 Non-Proprietary Figure 3-15 Openings in PSW Model for Hot and Cold Legs
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 57 Non-Proprietary Figure 3-16 Transition between PSW and Massive Concrete Block at El. 130-0 RIGID BEAMS LAYOUT SHELL SOLID
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 58 Non-Proprietary Figure 3-17 Interface between Shell and Solid Elements RIGID BEAMS LAYOUT at interface SHELL
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 59 Non-Proprietary Figure 3-18 Idealization for the RV Openings in PSW
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 60 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 3-19 Idealization of the SSW and Common Basemat Top TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 61 Non-Proprietary Figure 3-20 Shell - Solid Overlap between El. 94-6 to El. 100-0
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 62 Non-Proprietary Figure 3-21 Connection between RCS Supports and Solid Elements Rigid Beam Elements in the Solid Elements Rigid Beam Elements For the RCS Supports
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 63 Non-Proprietary Figure 4-1 Plan Layout of AB with Adjacent Buildings EMERGENCY DIESEL GENERATOR BUILDING
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 64 Non-Proprietary Figure 4-2 Global Coordinate System of AB
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 65 Non-Proprietary Figure 4-3 Common Basemat for AB and RCB
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 66 Non-Proprietary Figure 4-4 ANSYS Coarse Mesh of the Common Basemat for AB and RCB
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 67 Non-Proprietary Figure 4-5 Fine Mesh of 10 ft Thick AB Basemat
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 68 Non-Proprietary Figure 4-6 Coarse Mesh of 10 ft Thick AB Basemat
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 69 Non-Proprietary Figure 4-7 ANSYS Fine 3-D FEM of Auxiliary Building
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 70 Non-Proprietary Figure 4-8 ANSYS Coarse 3-D FEM of Auxiliary Building
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 71 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 4-9 ANSYS Coarse 3-D FEM of Auxiliary Building, E-W Cutting at Column Line AG and Looking North TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 72 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 4-10 ANSYS Coarse 3-D FEM of Auxiliary Building, N-S Cutting at Column Line 19 and Looking East TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 73 Non-Proprietary Figure 5-1 RCB, Cumulative Mass Ratio for Frequencies in Translational X-Direction 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0
10 20 30 40 50 60 70 Cumulative Mass Ratio Frequency (Hz.)
ANSYS FEM-Fine Mesh ANSYS FEM-Coarse Mesh Translational Modes in X (E-W)
Cumulative Mass Ratio
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 74 Non-Proprietary Figure 5-2 RCB, Cumulative Mass Ratio for Frequencies in Translational Y-Direction 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0
10 20 30 40 50 60 70 Cumulative Mass Ratio Frequency (Hz.)
ANSYS FEM-Fine Mesh ANSYS FEM - Coarse Mesh Translational Modes in Y (N-S)
Cumulative Mass Ratio
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 75 Non-Proprietary Figure 5-3 RCB, Cumulative Mass Ratio for Frequencies in Translational Vertical Z-Direction 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0
10 20 30 40 50 60 70 Cumulative Mass Ratio Frequency (Hz.)
ANSYS FEM-Fine Mesh ANSYS FEM -Coarse Mesh Translational Modes in Z (Vertical)
Cumulative Mass Ratio
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 76 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 5-4 Containment Structure (Translational Modes X or Y) - Mode 1 TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 77 Non-Proprietary Security-Related Information - Withhold Under 10 CFR 2.390 Figure 5-5 Containment Structure Drumming Mode Z - Mode 5 TS
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 78 Non-Proprietary Figure 5-6 IS Translational Mode X (E-W) - Mode 2 (CS Omitted from this Plot)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 79 Non-Proprietary Figure 5-7 IS Translational Mode Y (N-S) - Mode 2 (CS Omitted from this Plot)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 80 Non-Proprietary Figure 5-8 IS Vertical Mode Z - Mode 5 ( CS Omitted from this Plot)
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 81 Non-Proprietary Figure 5-9 Nomenclature of Selected Nodes for Containment Structure X4 X1 X2 X3 Y4 Y3 Y2 Y1 X
Y
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 82 Non-Proprietary Figure 5-10 Nomenclature of Selected Nodes for Primary Shield Wall
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 83 Non-Proprietary Figure 5-11 Nomenclature of Selected Nodes for Secondary Shield Wall
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 84 Non-Proprietary Figure 5-12 RCB, CS, Lateral Displacement, X-Direction 45 95 145 195 245 295
-1.000
-0.900
-0.800
-0.700
-0.600
-0.500
-0.400
-0.300
-0.200
-0.100 0.000 Elevation (ft)
Displacement (inches)
Containment Shell, Lateral Drift (X-Direction), Due to 1gx X1 -Coarse X1 -Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 85 Non-Proprietary Figure 5-13 RCB, CS, Lateral Displacement, Y-Direction 45 95 145 195 245 295
-1.000
-0.900
-0.800
-0.700
-0.600
-0.500
-0.400
-0.300
-0.200
-0.100 0.000 Elevation (ft)
Displacement (inches)
Containment Shell, Lateral Drift (Y-Direction), Due to 1gy Y1 - Coarse Y1 - Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 86 Non-Proprietary Figure 5-14 RCB, CS, Vertical Displacement, Z-Direction 45 95 145 195 245 295
-0.250
-0.200
-0.150
-0.100
-0.050 0.000 Elevation (ft)
Displacement (inches)
Containment Shell, Vertical Displacement, Due to 1gz X1 -Coarse X1 -Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 87 Non-Proprietary Figure 5-15 RCB, PSW, Lateral Displacement, X-Direction 45 65 85 105 125 145 165 185 205
-0.250
-0.200
-0.150
-0.100
-0.050 0.000 Elevation (ft)
Displacement (inches)
Primary Shield Wall, Lateral Drift (X-Direction), Due to 1gx X1-Coarse X1-Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 88 Non-Proprietary Figure 5-16 RCB, PSW, Lateral Displacement, Y-Direction 45 65 85 105 125 145 165 185 205
-0.250
-0.200
-0.150
-0.100
-0.050 0.000 Elevation (ft)
Displacement (inches)
Primary Shield Wall, Lateral Drift (Y-Direction), Due to 1gy Y4-Coarse Y4-Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 89 Non-Proprietary Figure 5-17 RCB, PSW, Vertical Displacement, Z-Direction 45 65 85 105 125 145 165 185 205
-0.050
-0.045
-0.040
-0.035
-0.030
-0.025
-0.020
-0.015
-0.010
-0.005 0.000 Elevation (ft)
Displacement (inches)
Primary Shield Wall, Vertical Displacement, Due to 1gz Coarse - Average Fine -Average
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 90 Non-Proprietary Figure 5-18 RCB, SSW, Lateral Displacement, X-Direction 45 65 85 105 125 145 165 185 205
-0.250
-0.200
-0.150
-0.100
-0.050 0.000 Elevation (ft)
Displacement (inches)
Secondary Shield Wall, Lateral Drift (X-Direction), Due to 1gx X1 -Coarse X1-Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 91 Non-Proprietary Figure 5-19 RCB, SSW, Lateral Displacement, Y-Direction 45 65 85 105 125 145 165
-0.250
-0.200
-0.150
-0.100
-0.050 0.000 Elevation (ft)
Displacement (inches)
Secondary Shield Wall, Lateral Drift (Y-Direction), Due to 1gy Y1-Coarse Y1-Fine
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 92 Non-Proprietary Figure 5-20 RCB, SSW, Vertical Displacement, Z-Direction 45 65 85 105 125 145 165 185 205
-0.050
-0.045
-0.040
-0.035
-0.030
-0.025
-0.020
-0.015
-0.010
-0.005 0.000 Elevation (ft)
Displacement (inches)
Secondary Shield Wall, Vertical Displacement, Due to 1gz Coarse - Average Fine -Average
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 93 Non-Proprietary Figure 5-21 RCB, CS, ISRS, El. 104-0 (Comparison of the ANSYS Coarse and Fine Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, X Direction, Damping = 5%
ANSYS Coarse 512395 'X1' ANSYS Fine 519863 'X1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, Y Direction, Damping = 5%
ANSYS Coarse 513157 'Y1' ANSYS Fine 522214 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, Z Direction, Damping = 5%
ANSYS Coarse 512395 'Z1' ANSYS Fine 519863 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 94 Non-Proprietary Figure 5-22 RCB, CS, ISRS, El. 160-0 (Comparison of the ANSYS Coarse and Fine Models) 0 0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, X Direction, Damping = 5%
ANSYS Coarse 512731 'X1' ANSYS Fine 520784 'X1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, Y Direction, Damping = 5%
ANSYS Coarse 512388 'Y1' ANSYS Fine 519843 'Y1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, Z Direction, Damping = 5%
ANSYS Coarse 512731 'Z1' ANSYS Fine 520784 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 95 Non-Proprietary Figure 5-23 RCB, CS, ISRS, El. 255-0 (Comparison of the ANSYS Coarse and Fine Models) 0 1
2 3
4 5
6 7
8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, X Direction, Damping = 5%
ANSYS Coarse 511503 'X1' ANSYS Fine 517308 'X1' 0
1 2
3 4
5 6
7 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, Y Direction, Damping = 5%
ANSYS Coarse 511440 'Y1' ANSYS Fine 517074 'Y1' 0
1 2
3 4
5 6
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, Z Direction, Damping = 5%
ANSYS Coarse 511503 'Z1' ANSYS Fine 517308 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 96 Non-Proprietary Figure 5-24 RCB, PSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and Fine Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, X Direction, Damping = 5%
ANSYS Coarse 510518 'X1' ANSYS Fine 515937 'X1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, Y Direction, Damping = 5%
ANSYS Coarse 510922 'Y1' ANSYS Fine 516380 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, Z Direction, Damping = 5%
ANSYS Coarse 510922 'Z1' ANSYS Fine 516380 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 97 Non-Proprietary Figure 5-25 RCB, PSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and Fine Models) 0 0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, X Direction, Damping = 5%
ANSYS Coarse 508006 'X1' ANSYS Fine 512059 'X1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, Y Direction, Damping = 5%
ANSYS Coarse 508200 'Y1' ANSYS Fine 512338 'Y1' 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, Z Direction, Damping = 5%
ANSYS Coarse 508200 'Z1' ANSYS Fine 512338 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 98 Non-Proprietary Figure 5-26 RCB, PSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and Fine Models) 0 1
2 3
4 5
6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, X Direction, Damping = 5%
ANSYS Coarse 508711 'X1' ANSYS Fine 513419 'X1' 0
1 2
3 4
5 6
7 8
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, Y Direction, Damping = 5%
ANSYS Coarse 508622 'Y1' ANSYS Fine 513193 'Y1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, Z Direction, Damping = 5%
ANSYS Coarse 508711 'Z1' ANSYS Fine 513419 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 99 Non-Proprietary Figure 5-27 RCB, SSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and Fine Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, X Direction, Damping = 5%
ANSYS Coarse 507422 'X1' ANSYS Fine 510651 'X1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, Y Direction, Damping = 5%
ANSYS Coarse 507652 'Y1' ANSYS Fine 511139 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, Z Direction, Damping = 5%
ANSYS Coarse 507422 'Z1' ANSYS Fine 510651 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 100 Non-Proprietary Figure 5-28 RCB, SSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and Fine Models) 0 1
2 3
4 5
6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, X Direction, Damping = 5%
ANSYS Coarse 507773 'X1' ANSYS Fine 511422 'X1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, Y Direction, Damping = 5%
ANSYS Coarse 507351 'Y1' ANSYS Fine 510513 'Y1' 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, Z Direction, Damping = 5%
ANSYS Coarse 507773 'Z1' ANSYS Fine 511422 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 101 Non-Proprietary Figure 5-29 RCB, SSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and Fine Models) 0 1
2 3
4 5
6 7
8 9
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, X Direction, Damping = 5%
ANSYS Coarse 508597 'X1' ANSYS Fine 513125 'X1' 0
5 10 15 20 25 30 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, Y Direction, Damping = 5%
ANSYS Coarse 508572 'Y1' ANSYS Fine 513051 'Y1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, Z Direction, Damping = 5%
ANSYS Coarse 508572 'Z1' ANSYS Fine 513051 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 102 Non-Proprietary Figure 5-30 RCB, CS, ISRS, El. 104-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, X Direction, Damping = 5%
SASSI 7023 'X1' ANSYS Coarse 512395 'X1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, Y Direction, Damping = 5%
SASSI 7578 'Y1' ANSYS Coarse 513157 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 104ft, Z Direction, Damping = 5%
SASSI 7023 'Z1' ANSYS Coarse 512395 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 103 Non-Proprietary Figure 5-31 RCB, CS, ISRS, El. 160-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, X Direction, Damping = 5%
SASSI 7308 'X1' ANSYS Coarse 512731 'X1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, Y Direction, Damping = 5%
SASSI 7016 'Y1' ANSYS Coarse 512388 'Y1' 0
0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 160ft, Z Direction, Damping = 5%
SASSI 7308 'Z1' ANSYS Coarse 512731 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 104 Non-Proprietary Figure 5-32 RCB, CS, ISRS, El. 255-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 1
2 3
4 5
6 7
8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, X Direction, Damping = 5%
SASSI 6218 'X1' ANSYS Coarse 511503 'X1' 0
1 2
3 4
5 6
7 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, Y Direction, Damping = 5%
SASSI 6155 'Y1' ANSYS Coarse 511440 'Y1' 0
1 2
3 4
5 6
7 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PCCV, ISRS, EL 255ft, Z Direction, Damping = 5%
SASSI 6218 'Z1' ANSYS Coarse 511503 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 105 Non-Proprietary Figure 5-33 RCB, PSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, X Direction, Damping = 5%
SASSI 5277 'X1' ANSYS Coarse 510518 'X1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, Y Direction, Damping = 5%
SASSI 5460 'Y1' ANSYS Coarse 510922 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 100ft, Z Direction, Damping = 5%
SASSI 5640 'Z1' ANSYS Coarse 510922 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 106 Non-Proprietary Figure 5-34 RCB, PSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, X Direction, Damping = 5%
SASSI 2800 'X1' ANSYS Coarse 508006 'X1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, Y Direction, Damping = 5%
SASSI 2994 'Y1' ANSYS Coarse 508200 'Y1' 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 156ft, Z Direction, Damping = 5%
SASSI 2994 'Z1' ANSYS Coarse 508200 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 107 Non-Proprietary Figure 5-35 RCB, PSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 1
2 3
4 5
6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, X Direction, Damping = 5%
SASSI 3505 'X1' ANSYS Coarse 508711 'X1' 0
1 2
3 4
5 6
7 8
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, Y Direction, Damping = 5%
SASSI 3416 'Y1' ANSYS Coarse 508622 'Y1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, PSW, ISRS, EL 191ft, Z Direction, Damping = 5%
SASSI 3505 'Z1' ANSYS Coarse 508711 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 108 Non-Proprietary Figure 5-36 RCB, SSW, ISRS, El. 100-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, X Direction, Damping = 5%
SASSI 2321 'X1' ANSYS Coarse 507422 'X1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, Y Direction, Damping = 5%
SASSI 2546 'Y1' ANSYS Coarse 507652 'Y1' 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 100ft, Z Direction, Damping = 5%
SASSI 2321 'Z1' ANSYS Coarse 507422 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 109 Non-Proprietary Figure 5-37 RCB, SSW, ISRS, El. 156-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 1
2 3
4 5
6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, X Direction, Damping = 5%
SASSI 2667 'X1' ANSYS Coarse 507773 'X1' 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, Y Direction, Damping = 5%
SASSI 2254 'Y1' ANSYS Coarse 507351 'Y1' 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 156ft, Z Direction, Damping = 5%
SASSI 2667 'Z1' ANSYS Coarse 507773 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 110 Non-Proprietary Figure 5-38 RCB, SSW, ISRS, El. 191-0 (Comparison of the ANSYS Coarse and the SASSI Models) 0 1
2 3
4 5
6 7
8 9
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, X Direction, Damping = 5%
SASSI 3391 'X1' ANSYS Coarse 508597 'X1' 0
5 10 15 20 25 30 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, Y Direction, Damping = 5%
SASSI 3366 'Y1' ANSYS Coarse 508572 'Y1' 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
US APR1400, SSW, ISRS, EL 191ft, Z Direction, Damping = 5%
SASSI 3366 'Z1' ANSYS Coarse 508572 'Z1'
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 111 Non-Proprietary Figure 5-39 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in X-Direction 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0
5 10 15 20 25 30 35 40 45 50 Frequency (Hz)
Cumulative Mass Ratio, X-Direction (2500 modes)
Coarse Mesh Fine Mesh
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 112 Non-Proprietary Figure 5-40 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in Y-Direction 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0
5 10 15 20 25 30 35 40 45 50 Frequency (Hz)
Cumulative Mass Ratio, Y-Direction (2500 modes)
Coarse Mesh Fine Mesh
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 113 Non-Proprietary Figure 5-41 AB, Comparison of Cumulative Mass Ratios of the Coarse and the Fine Models, in Z-Direction 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0
5 10 15 20 25 30 35 40 45 50 Frequency (Hz)
Cumulative Mass Ratio, Z-Direction (2500 modes)
Coarse Mesh Fine Mesh
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 114 Non-Proprietary Figure 5-42 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at South-West Corner (Column Lines AB-12) 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
SW Profile - 1g Static Displacements (AB Coarse Model)
Coarse X/X Coarse Y/Y Coarse Z/Z 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
SW Profile - 1g Static Displacements (AB Fine Model)
Fine X/X Fine Y/Y Fine Z/Z
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 115 Non-Proprietary Figure 5-43 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at North-West Corner (Column Lines AJ-12) 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
NW Profile - 1g Static Displacements (AB Coarse Model)
Coarse X/X Coarse Y/Y Coarse Z/Z 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
NW Profile - 1g Static Displacements (AB Fine Model)
Fine X/X Fine Y/Y Fine Z/Z
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 116 Non-Proprietary Figure 5-44 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at South-East Corner (Column Lines AA-26) 45 65 85 105 125 145 165 185 205 0.0 0.1 0.2 0.3 0.4 Elevation (ft)
Displacement (in)
SE Profile - 1g Static Displacements (AB Coarse Model)
Coarse X/X Coarse Y/Y Coarse Z/Z 45 65 85 105 125 145 165 185 205 0.0 0.1 0.2 0.3 0.4 Elevation (ft)
Displacement (in)
SE Profile - 1g Static Displacements (AB Fine Model)
Fine X/X Fine Y/Y Fine Z/Z
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 117 Non-Proprietary Figure 5-45 AB, Coarse and Fine Mesh Static Displacements for Vertical Profile at North-East Corner (Column Lines AK-26) 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
NE Profile - 1g Static Displacements (AB Coarse Model)
Coarse X/X Coarse Y/Y Coarse Z/Z 45 65 85 105 125 145 165 185 205 225 0.0 0.1 0.2 0.3 0.4 0.5 Elevation (ft)
Displacement (in)
NE Profile - 1g Static Displacements (AB Fine Model)
Fine X/X Fine Y/Y Fine Z/Z
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 118 Non-Proprietary Figure 5-46 AB Model Verification, ISRS at North-West Corner - El. 67-0 0
0.2 0.4 0.6 0.8 1
1.2 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 67, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 67, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 67, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 119 Non-Proprietary Figure 5-47 AB Model Verification, ISRS at East Face - El. 67-0 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 67, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 67, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 67, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 120 Non-Proprietary Figure 5-48 AB Model Verification, ISRS at South-West Corner - El. 77-0 0
0.2 0.4 0.6 0.8 1
1.2 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 77, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 77, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 77, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 121 Non-Proprietary Figure 5-49 AB Model Verification, ISRS at East Face - El. 77-0 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 77, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 77, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 77, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 122 Non-Proprietary Figure 5-50 AB Model Verification, ISRS at South-East Corner - El. 98-6 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SE Corner, Elev 98.5, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SE Corner, Elev 98.5, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SE Corner, Elev 98.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 123 Non-Proprietary Figure 5-51 AB Model Verification, ISRS at North-East Corner - El. 98-6 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 98.5, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 2
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 98.5, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 1.8 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 98.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 124 Non-Proprietary Figure 5-52 AB Model Verification, ISRS at North-East Corner - El. 120-0 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 120, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 120, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NE Corner, Elev 120, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 125 Non-Proprietary Figure 5-53 AB Model Verification, ISRS at East Face - El. 120-0 0
0.5 1
1.5 2
2.5 3
3.5 4
4.5 5
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 120, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 120, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 120, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 126 Non-Proprietary Figure 5-54 AB Model Verification, ISRS at South-West Corner - El. 137-6 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 137.5, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 137.5, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 137.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 127 Non-Proprietary Figure 5-55 AB Model Verification, ISRS at North-West Corner - El. 137-6 0
0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 137.5, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 137.5, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 137.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 128 Non-Proprietary Figure 5-56 AB Model Verification, ISRS at South-West Corner - El. 156-0 0
1 2
3 4
5 6
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 156, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 4
4.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 156, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 156, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 129 Non-Proprietary Figure 5-57 AB Model Verification, ISRS at North-West Corner - El. 156-0 0
0.5 1
1.5 2
2.5 3
3.5 4
4.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 156, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 4
4.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 156, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 156, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 130 Non-Proprietary Figure 5-58 AB Model Verification, ISRS at South-West Corner - El. 174-0 0
1 2
3 4
5 6
7 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 174, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
1 2
3 4
5 6
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 174, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at SW Corner, Elev 174, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 131 Non-Proprietary Figure 5-59 AB Model Verification, ISRS at North-West Corner - El. 174-0 0
1 2
3 4
5 6
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 174, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 4
4.5 5
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 174, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 174, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 132 Non-Proprietary Figure 5-60 AB Model Verification, ISRS at North-West Corner - El. 195-0 0
1 2
3 4
5 6
7 8
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 195, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
1 2
3 4
5 6
7 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 195, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at NW Corner, Elev 195, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 133 Non-Proprietary Figure 5-61 AB Model Verification, ISRS at East Face - El. 195-0 0
1 2
3 4
5 6
7 8
9 10 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 195, X-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
1 2
3 4
5 6
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 195, Y-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model 0
0.5 1
1.5 2
2.5 3
3.5 4
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at East Face, Elev 195, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 134 Non-Proprietary Figure 5-62 AB Model Verification, ISRS at Slab AG-AH-21 El. 120-0 0
1 2
3 4
5 6
7 8
9 10 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at Slab AG-AH-21-22, Elev 120, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 135 Non-Proprietary Figure 5-63 AB Model Verification, ISRS at Slab AG-AH-21 El. 137-6 0
1 2
3 4
5 6
7 8
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at Slab AG-AH-15-16, Elev 137.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 136 Non-Proprietary Figure 5-64 AB Model Verification, ISRS at MCR Slab - El. 156-0 0
1 2
3 4
5 6
7 8
0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at MCR Slab, Elev 156, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 137 Non-Proprietary Figure 5-65 AB Model Verification, ISRS at FHA Roof - El. 213-6 0
2 4
6 8
10 12 14 16 18 0.1 1
10 100 Acceleration (g)
Frequency (Hz)
AB Model Verification at FHA Roof, Elev 213.5, Z-Dir ANSYS Fine Mesh ANSYS Coarse Mesh SASSI RCB+AB Model
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 138 Non-Proprietary Figure 6-1 Structural Model of SASSI 3-D FEM of Combined NI
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 139 Non-Proprietary Figure 6-2 SASSI 3-D FEM of the Excavated Soil Volume for Combined NI Structure Foundation
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 140 Non-Proprietary Figure 6-3 SASSI 3-D FEM of the SFG and Lean Concrete Backfill for Combined NI Structures
FEM for SSI Analyses of NI Buildings APR1400-E-S-NR-14002-NP, Rev.2 KEPCO & KHNP 141 Non-Proprietary Figure 6-4 SASSI 3-D FEM of the Combined NI with Backfilled Soil