MONTHYEARML18060A3302018-02-28028 February 2018 Package: Request for Additional Information Regarding GE-Hitachi's Decommissioning Funding Plan Update for Morris ISFSI Project stage: Request ML18060A3332018-02-28028 February 2018 Letter to S. P. Murray Request for Additional Information Regarding GE-Hitachis Decommissioning Funding Plan Update for Morris ISFSI Project stage: RAI ML18060A3322018-02-28028 February 2018 Enclosurequest for Additional Request (Request for Additional Information Regarding GE-Hitachis Decommissioning Funding Plan Update for Morris ISFSI) Project stage: RAI ML18117A4722018-04-27027 April 2018 International - HI-STORM FW Amendment 4 Response to Request for Additional Information Project stage: Response to RAI ML18166A0032018-06-0808 June 2018 Submittal of License Application Revision 2 and Request to Restart Review of Application for Approval of the WCS CISF Project stage: Request ML18208A6372018-07-27027 July 2018 Supplement to HI-STORM FW Amendment 4 RAIs Responses Project stage: Request ML18291B0812018-10-17017 October 2018 Summary of Meeting with Holtec International, Inc. to Discuss the Upcoming Submittal of the Application for Renewal If the Storage Certificate of Compliance No. 1008 for the HI-STAR 100 Cask System Project stage: Meeting ML18291B2292018-10-17017 October 2018 Memorandum to M. Layton Summary of Sept. 12, 2018, Meeting with Holtec International, Inc. to Discuss the Upcoming Submittal of the Application for Renewal If the Storage Certificate of Compliance No. 1008 for the HI-STAR 100 Cask System Project stage: Request ML18360A0052018-12-26026 December 2018 Letter to J. Isakson Approval of Interim Storage Partners Request for Withholding Information from Public Disclosure - Waste Control Specialists Consolidated Interim Storage Facility Project stage: Withholding Request Acceptance ML19011A1272019-01-29029 January 2019 Letter to K. Manzione Amendment No. 4 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Second Request for Additional Information (W/Enclosure) Project stage: RAI ML19120A2172019-04-26026 April 2019 Memo to File Environmental Assessment and Finding of No Significant Impact for Energy Northwest Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72,30(b) and 72.30(c) for Humboldt Bay ISFSI Project stage: Other ML19120A2162019-04-26026 April 2019 Package: Environmental Assessment and Finding of No Significant Impact for Energy Northwest Decommissioning Funding Plan Submitted in Accordance with 10 CFR 72,30(b) and 72.30(c) for Humboldt Bay ISFSI Project stage: Request ML19165A1152019-06-14014 June 2019 Memoranda to File Environmental Assessment and Finding of No Significant Impact for the Virginia Electric and Power Company, Dominion Energy Kewaunee, Inc., and Dominion Nuclear Connecticut, Inc.S Decommissioning Funding Plans Submitted Project stage: Other ML19165A1142019-06-14014 June 2019 Package: Environmental Assessment and Finding of No Significant Impact for the Virginia Electric and Power Company, Dominion Energy Kewaunee, Inc., and Dominion Nuclear Connecticut, Inc.'S Decommissioning Funding Plans Submitted Project stage: Request ML21103A4292021-04-12012 April 2021 NRC 699 (4-6-21 GEH on Morris DFP, Signed) Project stage: Other ML21111A3342021-04-21021 April 2021 GEH - Response to Request for Additional Information for Acceptance Review of the Morris Operation SNM-2500 Decommissioning Funding Plan (DFP) Project stage: Response to RAI ML21110A1642021-04-27027 April 2021 Consultation Letter to State of Illinois on GEH-Morris DFP EA Project stage: Other ML21166A2062021-06-0404 June 2021 IEMA Response to GE Hitachi Morris Draft Ea. Review of the Draft Environmental Assessment and Finding of No Significant Impact for the Morris Operation Decommissioning Funding Plans Project stage: Request ML21167A3322021-06-15015 June 2021 Request for Additional Information on Morris Operation Decommissioning Funding Plans Project stage: RAI ML21168A2582021-06-17017 June 2021 GE-Hitachi Nuclear Energy Americas, LLC, Updated Morris Operation Decommissioning Funding Plan Project stage: Request ML21168A2572021-06-17017 June 2021 GE-Hitachi Nuclear Energy Americas, LLC, Updated Morris Operation Decommissioning Funding Plan Project stage: Request ML21190A1302021-06-17017 June 2021 GE Hitachi Nuclear Energy Americas, LLC, Morris Operation, Independent Spent Fuel Storage Installation, Decommissioning Funding Plan, Revision 5 (Redacted Version of ML21168A260) Project stage: Request ML21182A1072021-07-0808 July 2021 Response to Illinois Emergency Management Agency on GEH-Morris DFP EA Project stage: Other ML21214A0732021-07-25025 July 2021 IEMA Second Response to GE Hitachi Morris Draft EA FONSI on DFPs Project stage: Request W3F1-2021-0063, Request for One-Time Exemption from 10 CFR 50, Appendix E Biennial Emergency Preparedness Evaluated Exercise Requirements Due to Severe Storm Recovery2021-10-12012 October 2021 Request for One-Time Exemption from 10 CFR 50, Appendix E Biennial Emergency Preparedness Evaluated Exercise Requirements Due to Severe Storm Recovery Project stage: Request ML21319A2202021-11-17017 November 2021 Letter - Proprietary Determination for GEH Morris DFP Submittals Project stage: Other ML21216A2742021-12-21021 December 2021 Final EA on GEH Morris DFPs Project stage: Other ML21216A2732021-12-21021 December 2021 Memo to File for GEH Morris EA and FONSI Project stage: Other ML21216A2722021-12-21021 December 2021, 29 December 2021, 5 January 2022 GEH Morris Decommissioning Funding Plan Approval Project stage: Request ML21216A3202021-12-29029 December 2021 FRN for GEH Morris EA and FONSI DFPs Project stage: Other ML21216A2752022-01-0505 January 2022 GEH Morris DFP Close-out Letter Project stage: Other ML22286A0012022-10-12012 October 2022 NRC Form 699 for Technical Discussions from March 15 to 17 of 2022 Related to the Application of the Castor geo69 Storage System (Docket No. 72-1052) (Redacted) Project stage: Other ML23076A2722023-03-17017 March 2023 HI-STORM 100 Amendment 16 RAI 3-3 Clarification Project stage: Other ML23235A0662023-08-23023 August 2023 Proposed Additional Alternative to the ACI Code, Concrete Temperature Limits, Docket 72-1042, CoC 1042 Amendments 1, 2, and 3 Project stage: Other ML23277A1272023-10-24024 October 2023 Proposed Additional Alternative to the American Concrete Institute Code, Concrete Temperature Limits, for Certificate of Compliance No. 1042, Amendment Nos. 1, 2 & 3 Project stage: Other ML24002B1432024-01-0202 January 2024 Attachment (Redacted) - Email Dated 1/2/24 Dbussmann (Gns) to Ngarcia (Nrc), Staggered RAIs Castor geo69 Storage, Applicants Proprietary Review of Staggered RAIs Castor geo69 Storage Application-Shielding Evaluation (Public) Project stage: RAI ML24067A1852024-02-0808 February 2024 Attachment 1 - Conversation Record HI-STORM Flood/Wind Storage System Amendment 7: Staffs Observation on 1/26/2024 Meeting Project stage: Meeting L-24-004, Independent Spent Fuel Storage Installation - Responses to NRC Requests for Additional Information on the Diablo Canyon Independent Spent Fuel Storage Installation License Renewal Application (Cac/Epid 001028/L-2022-RNW-0007)2024-04-30030 April 2024 Independent Spent Fuel Storage Installation - Responses to NRC Requests for Additional Information on the Diablo Canyon Independent Spent Fuel Storage Installation License Renewal Application (Cac/Epid 001028/L-2022-RNW-0007) Project stage: Response to RAI 2021-04-21
[Table View] |
Text
Enclosure REQUEST FOR ADDITIONAL INFORMATION REGARDING GE-HITACHI NUCLEAR ENERGYS DECOMMISSIONING FUNDING PLAN UPDATE FOR GENERAL ELECTRIC HITACHI MORRIS INDEPENDENT SPENT FUEL STORAGE INSTALLATION DOCKET NO. 72-01 Regulatory Requirement Pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 72.30(c), at the time of license renewal and at intervals not to exceed 3 years, the decommissioning funding plan (DFP) required to be submitted by 10 CFR 72.30(b) must be resubmitted with adjustments as necessary to account for changes in costs and the extent of contamination. The DFP must update the information submitted with the original or prior approved plan. In addition, the DFP must also specifically consider the effect of the following events on decommissioning costs, as required by 10 CFR 72.30(c)(1)-(4): (1) spills of radioactive material producing additional residual radioactivity in onsite subsurface material, (2) facility modifications, (3) changes in authorized possession limits, and (4) actual remediation costs that exceed the previous cost estimate.
=
Background===
By letter dated December 11, 2015, GE-Hitachi Nuclear Energy (GEH) submitted, for U.S.
Nuclear Regulatory Commission (NRC) staff review and approval, a decommissioning funding plan update (DFP Update) for the independent spent fuel storage installation (ISFSI) at its Morris Facility (Agencywide Documents Access and Management System Accession No. ML15345A191). The NRC staff reviewed GEHs DFP update and believes GEHs submittal was not sufficient to meet the intent of the requirement in 72.30(c). The DFP update does not provide sufficient information to allow the NRC to determine that the events listed in 10 CFR 72.30(c)(1)-(4) have been specifically considered.
RAI 1
Provide a revised DFP that includes information on the occurrence, and the effect on decommissioning costs, of each of the events listed in 10 CFR 72.30(c)(1)-(4): (1) spills of radioactive material producing additional residual radioactivity in onsite subsurface material, (2) facility modifications, (3) changes in authorized possession limits, and (4) actual remediation costs that exceed the previous cost estimate.