Revises 890914 Partial Response to Item 1 Re NUREG-0737, Item II.D.1, Performance Testing of Relief & Safety Valves, Per 871020 Request.Porv & PORV motor-operated Block Valves Decsriptions Encl
ML18054B298
Person / Time
Site: Palisades 
Issue date: 12/12/1989
From: Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.D.1, TASK-TM TAC-44604, NUDOCS 8912180095
Download: ML18054B298 (5)


Text

consumers Power POWERINli MICHlliAN'S PRDliRESS General Offices: 1945 West Parnall Road, Jackson,' Ml 49201 * (517) 788-0550 December 12, 1989 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

NUREG 0737 II.D.l, PERFORMANCE TESTING OF RELIEF AND SAFETY VALVES (TAC 44604) - ADDITIONAL INFORMATION NRC letter dated October 20, 1987 requested 10 items of additional information regarding NUREG 0737, Item II.D.l - Performance Testing of Relief and Safety Valves.

Consumers Power Company (CPC) letters dated September 14, 1988, May 25, 1988 and March 30, 1989 responded to all of the Items in the request except Item 1.

The letter dated September 14, 1988 provided a partial response to Item 1.

Attachments 1 & 2 to this letter revise that partial response to Item 1 (block valve and PORV descriptions) provided in our September 14, 1988 letter.

NRC letter dated November 9, 1989 transmitted a Technical Evaluation Report (TER) which evaluates the Palisades compliance with NUREG 0737, Item II.D.l, Performance Testing of Relief and Safety Valves, and requested additional information regarding functional qualification of the new PORV and block valves.

That information will duplicate the information requested by Item 1 of the October 20, 1987 RAI.

Therefore, as discussed with the NRC Palisades Project Manager, CPC considers all items of the October 20, 1987 RAI to be complete.

A description of the functional qualification of the new PORVs and block valves will be provided in our response to the November 9, 1989 Technical Evaluation Report.

Richard W Smedley Staff Licensing Engineer CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Attachments OC1189-0224-NL04

=:*~? :L 21 :3(>(>

1:>'5 PDR ADOCK p

E:*::-1121 :2 0!:5000:255 F'DC A CAf5' ENERGY COMPANY

OC1189-0224-NL04 ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 POWER-OPERATED RELIEF VALVES Revision 1 December 12,.1989 1 Page

Valve:

POWER-OPERATED RELIEF VALVES Manufacturer Model No/Catalogue No Type Design Pressure Design Temperature Size-Inlet Size-Outlet Rating-Inlet-ANSI Pressure Class Rating-Outlet-ANSI Pressure Class Pressure-Operating Pressure-Relief Pressure Drop at Each Rated Capacity Temperature-Operating Temperature-Relief Set Pressure*

Capacity (For Each Operating Condition)

C, K-Factor EXd/End (Straight Through)

Wei~ht With Operator and Centzr of Gravity Throat Cross Section Area (in ) at Full Lift Lift, in Material:

Hard Facing Material Body Bonnet Seat Disc Guide & Ring(s)

Spring Operator:

Manufacturer Type Electric-Voltage Required Inrush & Holding, Amperes Nema Size, Coil Insulation Rating AIR-PSI (Minimum/Maximum & CFM)

Opening Time (seconds)

Closing time (seconds)

Limit Switches -

(Number, Type, Rating).

OC1189-0224-NL04 Target Rock 100 Globe "Y" Type 2500 psi 700°F 4"

4" 1736 Weld End 900 Weld End 2075 psia 2250 psia Critical tJ.p/stm 137 psi water 652.7°F 641. 03 °F 2400 psia 159.511/sec stm 165.711/sec wtr.

Cv=219/K-4.46

18. 00 11 50711/10-3/4" above £
5. 774 1.00 Stellite 6 SS 316 SS 316 SS316 SS hardfaced 17-4 PH 440C/17-7 PH A-286 Target Rock Solenoid 125 VDC, 3.5 amps in rush & holding CL H insulation

<2.0 sec

<2.0 sec 4/reed switches, 3 amps I

I I

I I

r I

I I

OC1189-0224-NL04 ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 PORV MOTOR OPERATED BLOCK VALVES Revision 1 December 12, 1989 1 Page

Valve:

PORV MOTOR OPERATED BLOCK VALVES Manuafacturer Model No/Catalogue No Type Design Pressure Design Temperature Size-Inlet Size-Outlet Rating-Inlet-ANSI Pressure Class (Std or Spec)

Rating-Outlet-ANSI Pressure Class (Std or Spec)

Pressure Drop at Each Rated Capacity Pressure Maximum Temperature Maximum C, K-Factor Ei{d/End (Straight Through)

Weight With Operator and Center of Gravity Material:

Hard Facing Material Body Bonnet-Type*

Seat/Type Disc/Type Trim Packing Operator:

Manufacturer Model Number Nema Size RPM (Motor)

Voltage - Nominal Time/Open (Seconds) for Each Operating Condition Time/Close (Seconds) for Each Operating Condition Motor Size Rating Current, Starting, Operating, Maximum Torque Handwheel Manual Operator (Yes/No)

Limit Seitches (Number, Type, Rating)

Torque Switches (Number, Type, Rating)

OC1189-0224-NL04 Set Edward Valve Fig 12011 Wedge Gate 2500 psi 700°F 4-in <j>Weld end 4-in <j>Weld end 1550 lb. ANSI Special Class 1550 lb. ANSI Special Class 760 16-in*

535 CG 18-in CL SA-351 GR CF8M SS SA-351 GR CF8M SS SA-182 GR F316 SS SA-487 GR CA6NM Garlock 98 11/

Garfoil Ctr Rings Limitorque SMB-00-25 1700 460 VAC 22 sec. max 22 sec. max Yes 4 NAMCO EA 180 I

I I

I I

I I