Submits Addl Info Re NUREG-0737,II.D.1, Performance Testing of Relief & Safety Valves. Ltr Identifies Pressurizer Block Valves & PORV Planned for Installation After Sept 1989 & Partially Responds to Item 1
ML18053A578
Person / Time
Site: Palisades 
Issue date: 09/14/1988
From: Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.D.1, TASK-TM TAC-44604, NUDOCS 8809220115
Download: ML18053A578 (3)


Text

consumers Power POWERIN&

NllCHlliAN'S PRO&RESS General Offices: 1945 West Parnell Road, Jacksi:>n, Ml 49201 * (517) 788-0550 September 14, 1988 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

NUREG 0737 II.D.l, PERFORMANCE TESTING OF RELIEF AND SAFETY VALVES (TAC NO. 44604) - ADDITIONAL INFORMATION NRC letter dated 10/20/87 requested 10 items of additional information regarding NUREG 0737, Item II.D.l - Performance Testing of Relief and Safety Valves.

Consumers Power Company letters dated March 29, 1988 and May 25, 1988 responded to Items 3-10 and notified the staff that we expected to respond to Items 1&2 before September 15, 1988.

This letter identifies the pressurizer block valves and PORVs we plan to install after September, 1989 and, therefore, partially responds to Item 1.

The remaining information requested in Item 1 (i.e. description and discussion of all similarities and any differences between the purchased valves and those tested in the EPRI program and verifi-cation of the operability of the block valves) and the information requested in Item 2 (the expected back pressure and bending moments) has not been documented at this time but will be submitted before April 1, 1989.

Purchase Orders for the new valves, two 4-inch Rockwell gate valves operated by SMB-00-25 limitorque operators and two 4-inch Target Rock Power Operated Relief Valves (PORVs), were placed last month.

Attachments 1 and 2 to this letter contain complete descriptions.

Richard W Smedley Staff Licensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector - Big Rock Point Attachments 8809220115 PDR ADOCK p

OC0988-0122-NL02 88091-4~

05000255 1

PDC L'

l/tJ'f'

'/ /

.Valve:

POWER-OPERATED RELIEF VALVES Manufacturer Model No/Catalogue No Type Design Pressure Design Temperature.

,Hydrostatic Test Pressure Size-Inlet Size-Outlet Rating-Inlet-ANSI Pressure Class (Std or Spec)

Rating-Outlet-ANSI Pressure Class (Std or Spec)

Pressure-Operating Pressure-Relief Pressure Drop at Each Rated Capacity Temperature-Operating Temperature-Relief Set Pressure Capacity (For Each Operating Condition)

C, K-Factor

.E~d/End (Straight Through)

Weight With Operator and Cent2r of Gravity Throat Cross Section Area (in ) at Full Lift Lift, in Material:

Hard Facing Material Body Bonnet Seat Disc Guide & Ring(s)

Spring Operator:

Manufacturer Type Electric-Voltage Required Inrush & Holding, Amperes Nema Size, Coil Insulation Rating AIR-PSl (Minimum/Maximum & CFM)

Opening Time (Seconds)

Closing Time (Seconds)

Limit Switches -

(Number, Type, Rating)

OC0988-0122-NL02 ATTACHMENT 1 To 9/14/88 CPC Letter to NRC Target Rock 100 Globe "Y" Type 2500 psi 700°F 4"

4" 1736 Weld End 900 Weld*End 2075 psia 2450 psia Critical 6p/stm 137 psi water 652.7°F 641.03°F 2400 psia 159.511/sec stm 165.711/sec wtr.

Cv=l61/K-4.46 18.00" 50711/102.3/4" above £ 6.52 in

.875 Stellite 6 SS 316 SS 316 SS316 SS hardfaced 17-4 PH 440C/17-7 PH A-286 Target Rock Solenoid 125 VDC, 3.5 amps in rush & holding CL H insulation 1.68 sec water/0.31 sec stm 1.26 sec water/1.14 sec stm 4/reed switches, 3 amps

ATTACHMENT 2 To 9/14/88 CPC Submittal to NRC PORV MOTOR OPERATED BLOCK VALVES Valve:

Manufacturer Model No/Catalogue No Type Design Pressure Design Temperature Size-Inlet Size-Outlet Rating-Inlet-ANSI Pressure Class (Std or Spec)

Rating-Outlet-ANSI Pressure Class (Std or Spec)

Pressure Drop at Each Rated Capacity Pressure Maximum Temperature Maximum C, K-Factor EXd/End (Straight Through)

Weight With Operator and Center of Gravity Material:

Hard Facing Material Body Bonnet-Type Seat/Type Disc/Type Trim Packing Operator:

Manufacturer Model Number Nema Size RPM (Motor)

Voltage - Minimum/Maximum Time/Open (Seconds Minimum/Maximum) for Each Operating Condition Time/Close (Seconds Minimum/Maximum) for Each Operating Condition Motor Size Rating Current, Starting, Operating, Maximum Torque Set Handwheel Manual Operator (Yes/No)

Limit Switches (Number, Type, Rating)

Torque Switches (Number, Type, Rating)

OC0988-0122-NL02 Rockwell Fig 12011 Wedge Gate 2500 psi 700°F 4-in (/J Weld end 4-in (/J Weld end 1550 lb. ANSI Special Class 1550 lb. ANSI Special Class 760 16-in 535 CG 18-in CL SA-351 GR CF8M SS SA-351 GR CF8M SS SA-182 GR F316 SS SA-487 GR CA6NM Garlock 98 11/

Garfoil Ctr Rings Limitorque SMB-00-25 21 21 3600 RPM 4 NAMCO EA 180