DISTRIBUTION FOR ANNUAL/SEMI-ANNUM ENVIRO REPORTS/ENVIRO MONITORING RPTS (OL STAGE) t NRC FORM 195 U.S. NUCLEAR REGULATORY MISSION I2 78) f

~II Fi'RC DISTRIBUTION FDR PART 50 DOCKET MATERIAL DOCK T NUMBER FILE NUMBER

. ENVIRONMENTAL TOe NRC FROM:

Niagara Mohawk Pwr Corp

Syracuse, NY R R Schneider DATE OF DOCUMENT 9-16-77 DATE RECEIVED 9-20-77 ETTE R

/ORIGINAL QCOPY DESCRIPTION QNOTORIZED JUNC I.ASSI F I E D PROP INPUT FORM ENCLOSU RE NUMBER OF COPIES RECEIVED Re NRC ltr dtd 8-26-77.......trans the following:

corrections to data submitted in their 1976 semi-annual effluent release report lp PLANT NAME:

9-20-77.

BRANCH CHIEF:

Nine Nile Pt gl

,ehf FOR ACTION/INFORMATION PR JECT MANAGER:

LIC. ASST:

(5)

  • ~

1 EACH TO EPA H S

EPA REGION NOAA F

G W

G FILE INTERNALDISTRl BUTION I C E 2

G I S

BALLARD J.

COLLINS KREGER KASTNER LPDR:

TIC NSIC ACRS M 1 CY SENT AS EXTERNALDISTRIBUTION A EGORY B CO TROL NUMBER

~ g

NIAGARAMOHAWKPOWER CORPORATION K%II'OIIt'IlKITI'tI.fIIPlt 300 ERIE 80ULEVARD, WEST SYRACUSE, N. Y. 13202 September 16, 1977 U.

S. Nuclear Regulatory Commission Office of Management Information and Program Control Operating Data Branch, 12105 MNBB Washington, D.

C.

20555

"~~~~vEg 4i>ep Cg lg Re:

Nine Mile Point Unit 1 Docket No. 50-220

DPR-'63

entlemen:

We have completed our review of the effluent and waste disposal data as reques'ted by Mx.

G. Lear's letter of August 26, 1977.

The 'suggested corrections to this data are shown on the attached tables.

An amendment to our effluent and waste disposal semi-annual reports fox'ine Mile Point Unit 1 will be forwarded under sep'arate cover at a latex'ate.

Vex'y truly youx's, NIAGARA MOHAWK POWER CORPORATION R. Schneidex Vice President-Electric Production

<~ AQb PEF/szd Attachment

Bg L N 08 d3S LL6L Lwn owssaooua LH3HAQOQ 03Al=338

FACILITY NINC MILE POINT TYPE:

BMR LOCATION 8 MI NE OSWEGO NY COOLING MATER SOURCE LAKE ONTARIO DOCKET No 50-270 LICENSED POMER IHMT)t 1850+0 INITIAL CRITICALITYI 09/05/69 Ooo Oeo OPCRATION GROSS THERMAL GENERATION NFT ELECTRICAL

=

THERHAL CAPACITY FACTOR IDURING COMMERCIAL OPERATION) 13086781~0 4112827+ 0 76.8 HMHT HWHE PER CENT SUHHARY OF CFFLUENTS AIRBORNE A)

TOTAL NOBLE GASES 8)

TOTAL 1-131 C)

TOTAL HALOGENS( INCLUDING I-Igl) 0)

TOTAL PARTICULATES E)

TOTAL TRITIUH LIQUID A)

TOTAL MIXED FISSION AND ACTIVATION PRODUCTS 8)

TOTAL TRIT IUH C)

OISOLVED NOBLC GASES O)

VOLUHC OF LIQUID WASTC RELEASEO C).

VGLUtfE OF DILUTION WATER SOLID MASTE *~~

1 ~ 76E+05 2 10E+00 8 64E+00 1

85E+01 2al4E+00 2't6E+00 1~63E+06 2 '9F+11

<1.03 E-01

<5.58 E-03 CUR IES CURIE S CURICS CUR I ES CUR IES CURIES CURIE S CUR IES LI TCRS LITERS

~ ~H Sirrt~r)<y'pal'j:s Diir~e~r- >+4 7gE au& oF r>On/~y / /~4S~

~xQ/Hrnl +'~~~+i&vc' A)

VOLUME 8)

ACT )VI TY C)

NUMBER OF SHIPHE4TS 5'8Et02 2.51 E+03 8.60EtDI CUBIC METERS.',

CUR IES

0 fg I

AIRBORNE EFFLUENTS ICURIES)

NOBLE GAS UNIOENTIFI ED KR-85H KR-87 KR-88 XE-133 XE-135 XE-135H XE-138 HALOGENS 1 60E404 8 '8E+03 2.72E+04 2 77E+04 7 'OF+03

4. 16E+04 2 58E+02 4.78E+04

'PARTICULATES I-131 I-133 1-135 2.)OE+00

4. 84 E+00

).70E<00 TRITIUN CR-51 HN-54 Fh-59 CO-58 CO-60 ZN-65 SR-89 SR-90 ZR-95 NB-95 RU-103 RU-106 CS-)34 CS-137 CE-141 CE-)44 LA-140 8 A/LA-)40 H-3 8 ~ 44E-04

) ~ 77E-03 7 98E-05 2 '4E-04 I 55E-02 7'$ E-05 I ~ 25E"02

() ~ )4E-04 8'?E-05 I 0)E-04 2 '5E-05 I ~ 24E-04 2 3)E-03.

7 78E-03 2 6)L'-04 2

lOF-04 1

85E+01 should not be reported separately 6.15 E-02

J40 0

1

LIQUID EFFLUENTS ICURIES)

~

~

S XE-133 XE-135 1-131 I-133 NA-24 CR-51 HN-54 CO-58 FE-59 CQ-60 AS-76 SR-89 SR-90 ZR/NB-95 Yin-99 TC-99N SB-124 CS-134 CS-137 8A/LA-140 CE-141 H-187 NP-239 UNIDEMTIF IED TR IT IUiI 93E-03 I ~ 62E-02 2 74E-03 95E-02 le2IE-OI 1.51E-OI 4 '6E-02 3 60E-03 6 15E-01 3.34C-02 7 46E-02 7 35E-03 1 ~ 73F.-03 lo70E 03 I ~ 70E-03 I ~ 09E-02 2 91E-01 5 17E-01 3 '2E-02 2 20E-03 1~6 I E-OI 4 10E-03 (1 ~ OOE-04 2+46E+00

%.65 E-03

  • Corrections are due to a typographical error on Niagara Hohawkts part in reporting the third quarter XE-135=liquid effluent activity.

~

f

~.

4

~ ~

Ee