Technical Requirements Manual
ML18016A050
Person / Time
Site: Susquehanna 
Issue date: 12/19/2017
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML18016A050 (43)


Text

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2017-25366 USER INFORMATION:

GERLACH*ROSEY M Address: NUCSA2 Phone#:

542-3194 EMPL#: 028401 CA#:

0363 TRANSMITTAL INFORMATION:

TO:

12/19/2017 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

JJC\\..o *

..L.J I Page 1

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

TENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no C will be issued with the updated material.

TRMl -

TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 12/07/2017 ADD MANUAL TABLE OF CONTENTS DATE: 12/18/2017 CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT 3.1.3 ADD:

REV: 6 REMOVE:

REV:5 I/\\

I I,,

of 2

- ~

CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT 3.7.3.8 REMOVE:

REV: 12 ADD:

REV: 13 CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT B3.l.3 REMOVE :

REV: 3 ADD:

REV: 4 CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT LOES ADD:

REV: 92 REMOVE:

REV:91 J.J~'-*

..1....1, Page 2

P.NY DISCREPANCIES WITH THE M.~TERIAL PROVIDED, CONTACT DCS@ X3107 OR X3171 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

of 2

SSES MANUAL Manual Name :

TRMl

    • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:

12/18/2017 Procedure Name Rev 92 Issue Date.

12/18/2017 Change ID TEXT LOES

Title:

LIST OF EFFECTIVE SECTIONS TEXT TOC 25 04/28/2015

Title:

TABLE OF CONTENTS TEXT 1.1 1

01/31/2014

Title:

USE MJD APPLICATI0£-J DEFI~JITIONS

~~-~. ', -..

,/'-,._

".,/

TEXT 2.1 04/28/2015 /'*,,,

,,-:***/

Title:

PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS '*,..,

2

~

"',~

( (""**.., \\\\ **,.//

\\

\\

10 Ol/}1/2014~. ; )

SETPOINTS I~STRUMENT-TRIP SETPOINT

/"'

TEXT 2.2

Title:

PLANT PROGRAMS AND TABLE TEXT 3.0 5 // \\.03/05/'2015

  • ,, /'

Change Number

Title:

TECHNICAL REQUIREMENT.efort oi?EruvrroN (TRo> APPLICABILITY & SURVEILLANCE (TRS)

APPLICABILITY

~

TEXT 3.1.1

/--- - - ~::,

.. 'J. * - --/11/09/2007

~-~-~~

REACTIVITY CON:iROL-.. s\\::sTEr4S ANTICIPATED TRANSIENT I

I

~

INJECTION (ATW~ -"{\\RI )1 ]jNSTRUMENTATION

\\,

'"**-~..._.J'

/

i ;

,'\\ -. --

0 WITHOUT SCRAM ALTERNATE ROD

Title:

TEXT 3.1.2 11/18/2002 r

\\

~

Title:

REACTIVI~Y*CON~ROL SYSTEMS CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT 3.1.3 6

12/18/2017

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 0

11/18/2002

Title:

REACTIVITY CONTROL SYSTEMS*CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &

CHECK VALVE TEXT 3.2.1 17 03/31/2016

Title:

CORE OPERATING LIMITS REPORT (COLR)

Pagel of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

  • ~nual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1 0

11/18/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TE)C:T 3. 3. 4 11 06/29/2017

Title:

INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION TEXT 3.3.5 0

11/18/2002

Title:

INSTRUivIENTATION THIS PAGE INTENTIONALLY LEFT BLANK EXT 3.3. 6 4

04/29/2014

Title:

INSTRUMENTATION TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 2

11/10/2015

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1

10/22/2003

Title:

INSTRUMENTATION INTENTIONALLY LEFT BLANK TEXT 3.3.9 3

04/17/2008

Title:

OPRM INSTRUMENTATION CONFIGURATION TEXT 3.3.10 1

12/14/2004

Title:

INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015

Title:

WATER MONITORING INSTRUMENTATION Page J of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

~Fnual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.4.1 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY TEXT 3.4.2

Title:

REACTOR COOLANT SYSTEM TEXT 3.4.3 1

1 04/16/2009 INTENTIONALLY LEFT BLANK 11/09/2007

Title:

REACTOR COOLP-..NT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAK.~GE MONITORS TEXT 3.4.4 2

04/17/2008

Title:

REACTOR COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT 3.4.5 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR VESSEL MATERIALS 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT 3.5.1 1

02/04/2005

Title:

EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/18/2002

Title:

EMERGENCY CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.l 0

11/18/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3 6 3 0

11/18/2002

., Tit~e: CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page~

of 16 Report Date: 12/19/17

SSES MANUAL I

Manual Name:

TRMl

'anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.6.4 0

11/18/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1 0

11/18/2002

Title:

PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW) SHUTDOWN TEXT 3.7.2 0

11/18/2002

Title:

PLANT SYSTEMS ULTIMATE HEAT SINK {UHS) Al'ID GROUND WATER LEVEL TE:'.\\T 3. 7. 3. 1 4

02/16/2017

Title:

PLANT SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT 3.7.3.2 3

04/16/2009

Title:

PL.AJ.~T SYSTEMS SPRAY AND SPRINKLER SYSTEMS

'EXT 3. 7. 3. 3 4

05/16/2016

Title:

PLANT SYSTEMS CO2 SYSTEMS TEXT 3.7.3.4 2

04/16/2009

Title:

PLANT SYSTEMS HALON SYSTEMS TEXT 3.7.3.5 2

04/16/2009

Title:

PLANT SYSTEMS FIRE HOSE STATIONS TEXT 3.7.3.6 2

04/16/2009

Title:

PLANT SYSTEM$ YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT 3.7.3.7 1

04/26/2006

Title:

PLANT SYSTEMS FIRE RATED ASSEMBLIES TEXT 3.7.3.8 13 12/18/2017

Title:

PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION TEXT 3.7.4 1

04/26/2006

Title:

PLANT SYSTEMS SOLID RADWASTE SYSTEM Page!

of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

~anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/18/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TElC:T 3. 7-. 6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MONITORING MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION

.'.EXT 3.7.8 5

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 2

01/31/2014

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT. 3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.11 0

04/16/2009

Title:

STRUCTURAL INTEGRITY TEXT 3.8.1 2

04/05/2010

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT 3.8.2.2 2

12/14/2004

~

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

AUTOMATIC Page~

of 16 Report Date: 12/19/17

SSES MANUAL

'I Manual Name :

TRMl

  • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.8.3 2

03/05/2015

Title:

ELECTRICAL POWER DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT 3.8.4 0

11/18/2002 Title~ ELECTRICAL POWER 24 VDC ELECTRICAL POWER SUBSYSTEM TEXT 3.8.5 1

11/14/2013

Title:

ELECTRIC..'ZU, POWER DEGRADED VOLTAGE PROTECTION TEXT 3.8.6 l

12/08/2011

Title:

ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.8.7 1

06/15/2009

Title:

BATTERY ~IAINTENANCE AND MONITORING PROGRAM EXT 3.9.1 0

11/18/2002

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/18/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/18/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006

Title:

MISCELLANEOUS SEAL SOURCE CONTAMINATION TEXT 3.10.2 2

08/08/2006

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 2

04/17/2008

Title:

INTENTIONALLY LEFT BLANK Page§.

of 16 Report Date: 12/19/17

SSES MANUAL I

Manual Name:

TRMl

.;i,nual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.1 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION TEXT 3. 11. 1. 2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE TEXT 3. 11. 1. 3 1

04/26/2006

Title:

P31DIOACTIVE EFFLUENTS LIQUID WASTE TREATMENT SYSTEM TEXT 3. 11. 1. 4 10/09/2012

Title:

RADIOACTIVE EFFLUENTS LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT 3.11.1.5 3

03/05/2015

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION

.}XT 3.11.2.1 3

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE RATE TEXT 3.11.2.2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

NOBLE GASES TEXT 3.11.2.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM TEXT 3. 11. 2. 4 0

11/18/2002

Title:

RADIOACTIVE EFFLUENTS GASEOUS RADWASTE TREATMENT SYSTEM TEXT 3.11.2.5 4

07/03/2013

Title:

RADIOACTIVE EFFLUENTS VENTILATION EXHAUST TREATMENT SYSTEM TEXT 3.11.2.6 8

06/29/2017

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT 3.11.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS TOTAL DOSE Page J_

of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

  • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11. 4.1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMP~.RISON PROG~..M TE:x:T 3. 12. l 0

11/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAL"v! HEAVY LOADS REQUIREMENTS

EXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT 4.1 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS ORGANIZATION TEXT 4.2 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS REPORTABLE EVENT ACTION TEXT 4.3 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS SAFETY LIMIT VIOLATION TEXT 4.4 1

12/18/2008

Title:

ADMINISTRATIVE CONTROLS PROCEDURES & PROGRAMS TEXT 4.5 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS REPORTING REQUIREMENTS TEXT 4.6 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS RADIATION PROTECTION PROGRAM Page~

of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

~anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4.7 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS TRAINING TEXT B3.0 5

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY TEXT B3.l.l 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT B3.l.3 4

12/18/2017

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRD~IENTATION

~EXT B3.l.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.l 0

11/19/2002

Title:

CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)

TEXT B3.3.l 1

01/31/2014

Title:

INSTRUMENTATION BASES RADIATION MONITORING INSTRUMENTATION TEXT B3.3.2 2

03/31/2011

Title:

INSTRUMENTATION BASES SEISMIC MONITORING INSTRUMENTATION TEXT B3.3.3 3

12/18/2008

Title:

INSTRUMENTATION BASES METEOROLOGICAL MONITORING INSTRUMENTATION TEXT B3.3.4 7

06/29/2017

Title:

INSTRUMENTATION BASES TRM POST ACCIDENT MONITORING (PAM) INSTRUMENTATION TEXT B3.3.5 2

11/09/2007

Title:

INTENTIONALLY LEFT BLANK Page 1 of 16 Report Date: 12/19/17

SSES MANUAL

  • J Manual Name:

TRMl

  • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.3.6 5

01/31/2014

Title:

INSTRUMENTATION BASES TRM ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7 2

11/10/2015

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22/2003

Title:

INTENTIONALLY LEFT BLANK TEXT B3.. 3.9 3

04/17/2008

Title:

OPRM INSTRUMENTATION TEXT B3.3.10 3

08/09/2010

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS

'EXT B3.3.11 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.3.12 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2 1

04/16/2009

Title:

INTENTIONALLY LEFT BLANK TEXT B3.4.3 1

11/09/2007

Title:

REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT B3.4.5 0

11/19/2002,

Title:

REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 10 of 16 Report Date: 12/19/17

SSES MANUAL Manual Name ~

TRMl

~nual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3,. 4. 6 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT B3.5.1 0

11/19/2002

Title:

ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 1

11/09/2007

Title:

ECCS Al\\TD RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT B3.5.3 l

11/09/2007

Title:

ECCS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.l 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING

~XT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2

04/17/2008

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.l 0

11/19/2002

Title:

PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)

TEXT B3.7.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UHS) GROUND WATER LEVEL TEXT B3.7.3.l 4

02/16/2017

Title:

PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT B3.7.3.2 2

04/26/2006

~,

Title:

PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS Page 11 of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

  • anual

Title:

TECHNICAL REQUIREMENTS.MANUAL UNIT 1 TEXT B3.7.3.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES CO2 SYSTEMS TEXT B3.7.3.4 3

04/29/2014

Title:

PLANT SYSTEMS BASES HALON SYSTEMS TEXT B3.7.3.5 1

04/26/2006

Title:

PLANT SYSTEMS BASES FIRE HOSE STATIONS TEXT B3.7.3.6 l

04/26/2006

Title:

PLANT SYSTEMS BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT B3.7.3.7 0

11/19/2002

Title:

PLANT SYSTEMS BASES FIRE RATED ASSEMBLIES

'EXT B3. 7. 3. 8 3

09/27/2012

Title:

PLANT SYSTEMS BASES FIRE DETECTION INSTRUMENTATION TEXT B3.7.4 0

11/19/2002

Title:

PLANT SYSTEMS BASES SOLID RADWASTE SYSTEM TEXT B3.7.5.l 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT B3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT B3.7.5.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES LIQUID HOLDUP TANKS TEXT B3.7.6 4

06/04/2013

Title:

PLANT SYSTEMS BASES ESSW PUMPHOUSE VENTILATION TEXT B3.7.7 2

01/31/2008

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION Page 12 of 16 Report Date: 12/19/17

I SSES MANUAL Manual Name:

TRMl

    • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.8 4

01/31/2014

Title:

PLANT SYSTEMS BASES SNUBBERS TEXT B3.7.9 2

12/08/2011

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.7.ll l

04/14/2010

Title:

STRUCTURAL INTEGRITY TEXT B3.8.1 2

03/10/2010

Title:

ELECTRICAL PROTECTIVE POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT DEVICES

.'EXT B3.8.2.l 0

11/19/2002

Title:

ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT B3.8.2.2 1

09/17/2004

Title:

ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

AUTOMATIC TEXT B3.8.3 0

11/19/2002

Title:

ELECTRICAL POWER BASES DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT B3.8.4 0

11/19/2002

Title:

ELECTRICAL POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM TEXT B3.8.5 1

11/14/2013

Title:

ELECTRICAL POWER BASES DEGRADED VOLTAGE PROTECTION TEXT B3.8.6 2

12/08/2011

Title:

ELECTRICAL POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING TEXT B3.8.7 2

06/04/20li

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM Page ]d of 16 Report Date: 12/19/17

SSES MANUAL Manual Nrune:

TRMl

  • anual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1

03/31/2006

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION

'EXT B3 10 3 0

11/19/2002 *

~*

Titl~: ~ISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.10.4 1

04/17/2008

Title:

INTENTIONALLY LEFT BLANK TEXT B3.ll.l.l 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION TEXT B3.11.1. 2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS DOSE TEXT B3. 11. 1. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM TEXT B3.11.1. 4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3. 11. 1. 5 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID.PROCESS MONITORING INSTRUMENTATION Page 14 of 16 Report Date: 12/19/17

SSES MANUAL Manual Name:

TRMl

    • i.nual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3. 11. 2. 1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.ll.2.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

NOBLE GASES TEXT B3.ll.2.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

IODINE, TRITIUM, ~_ND RADIONUCLIDES IN PARTICULATES FORM TEXT B3.ll.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.ll.2.5 5

07/03/2013

Title:

RADIOACTIVE EFFLUENTS BASES VENTILATION EXHAUST TREATMENT SYSTEM

.JXT B3.ll.2.6 2

09/08/2016

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT B3.ll.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES TOTAL DOSE TEXT B3. 11. 4. 1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS BASES MONITORING PROGRAM TEXT B3.11.4.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LAND USE CENSUS TEXT B3. 11. 4. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES INTERLABORATORY COMPARISON PROGRAM TEXT B3.12.l 1

10/04/2007

Title:

LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT B3.12.2 1

12/03/2010

~

Title:

LOADS CONTROL PROGRAM BASES HEAVY LOADS REQUIREMENTS Page 15 of 16 Report Date: 12/19/17

SSES MANUAL Manual Name :

TR.J.\\11

  • ,Tanual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS Page 16 of 16 Report Date: 12/19/17

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC TABLE OF CONTENTS 04/23/20'15 1,0 USE AND APPLICATION 1.1 Definitions 01/21/2014 2.0 PLANT PROGRAMS 2.1 Plant Programs 04/23/2015 2.2 Instrument Trip Setpoint Table 01/21/2014 3.0 APPLICABILITY 3.0 Technical Requirement for Operation (TRO) Applicability 02/19/2015 3.1 REACTIVITY CONTROL SYSTEMS 3.1.1 Anticipated Transient Without Scram Alternate Rod Injection 10/31/2007 (A TWS-ARI) Instrumentation 3.1.2 Control Rod Drive (CRD) Housing Support 08/31/1998 3:1.3 Control Rod Block Instrumentation 12/'15/2017 3.1.4 Control Rod Scram Accumulators Instrumentation and Check Valve 02/18/1999 3.2 CORE OPERATING LIMITS REPORT 3.2.1 Core Operating Limits Report 03/24/2016 3.3 INSTRUMENTATION 3.3.1 Radiation Monitoring Instrumentation 07/16/1999 3.3.2 Seismic Monitoring Instrumentation 03/10/2011 3.3.3 Meteorological Monitoring instrumentation 10/31/2007 3.3.4 TRM Post-Accident Monitoring Instrumentation 06/20/2017 3.3.5 Section Not Used 3.3.6 TRM Isolation Actuation Instrumentation 04/11/2014 3.3.7 iviain Turbine Overspeed Protection System 11/04i2015 3.3.8 Section Not Used

'I 0/22/2003 3.3.9 OPRM Instrumentation Configuration 03/27/2008 3.3.10 Reactor Recirculation Pump MG Set Stops 12/03/2004 3.3.1'1 MVP Isolation Instrumentation 10/22/2003 3.3.'12 Water Monitoring Instrumentation 02/19/2015 3.4 REACTOR COOLANT SYSTEM 3.4.1 Reactor Coolant System Chemistry 03/31/2006 3.4.2 Section Not Used 04/01/2009 3.4.3 High/Low Pressure Interface Leakage Monitors 10/31/2007 3.4.4 Reactor Recirculation Flow and Rod Line Limit 03/27/2008 3.4.5 Reactor Vessel Materials 03/31/2006 3.4.6 Reactor Recirculation Single Loop Operation (SLO) 04/25/2013 Flow Rate Restriction

,~

SUSQUEHANNA - UNIT 1 TRM/ LOES-1 EFFECTIVE DATE '12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.5 EMERGENCY CORE COOLING AND RCIC 3.5.1 ADS Manual Inhibit O'I /28/2005 3.5.2 ECCS and RCIC System Monitoring Instrumentation 10/31/2007 3.5.3 Long Term Nitrogen Supply to ADS 08/31/1998 3.6 CONTAINMENT 3.6.1 Venting or Purging 08/31/1998 3.6.2 Suppression Chamber-to-Drywell Vacuum Breaker Position 04/16/2014 3.6.3 Suppression Pool Alarm Instrumentation 01/07/2002 3.6.4 Primary Containment Closed System Boundaries 12/31/2002 3.7 PLANT SYSTEMS 3.7.1 Emergency Service Water System (ESW) Shutdown 08/31/1998 3.7.2 Ultimate Heat Sink (UHS) and Ground Water Level 08/31/1998 3.7.3:I Fire Suppression Water Supply System 01/26/2017 3.7.3.2 Spray and Sprinkler Systems 04/07/2009 3.7.3.3 CO2 Systems 05/09/20'16 3.7.3.4 Halon Systems 04/07/2009 -

C 3.7.3.5 Fire Hose Station 04/07/2009 3.7.3.6 Yard Fire Hydrants and Hydrant Hose Houses 04/07/2009 3.7.3.7 Fire Rated Assemblies 03/31/2006 3.7.3.8 Fire Detection Instrumentation 12/15/2017 3.7.4 Solid Radwaste System 03/31/2006 3.7.5 Explosive Gas and Storage Tank Radioactivity Monitoring Program 3.7.5.1 Main Condenser Offgas Hydrogen Monitor 02/19/2015 3.7.5.2 Main Condenser Offgas Exp!osive Gas Mixture 08/31/1998 3.7.5.3 Liquid Holdup Tanks 03/31/2006 3.7.6 ESSW Pumphouse Ventiiation 05/24/20*,2 3.7.7 Main Condenser Offgas Pretreatment Logarithmic Radiation W1onitorf ng instrurnentatior1 09i04i2008 3.7.8 Snubbers 02/19/2015 3.7.9 Control Structure HVAC 08/16/2006 3.7.10 Spent Fuel Storage Pools (SFSPs) 12/03/2004 3.7.11 Structural Integrity 04/01/2009 SUSQUEHANNA - UNIT 1 TRM/ LOES-2 EFFECTIVE DATE 12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 UST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.8 ELECTRICAL POWER 3.8.1 Primary Containment Penetration Conductor Overcurrent 03/25/2010 Protective Devices 3.8.2.1 Motor Operated Valves (MOV) Thermal Overload Protection -

Continuous 10/31/2007 3.8.2.2 Motor Operated Valves (MOV) Thermal Overload Protection -

Automatic 12/03/2004.

3.8.3 Diesel Generator (DG) Maintenance Activities 02/19/2015 3.8.4 24 VDC Electrical Power Subsystem 04/02/2002 3.8.5 Degraded Voltage Protection 11/07/2013 3.8.6 Emergency Switchgear Room Cooling 11/30/2011 3.8.7 Battery Monitoring and Maintenance program 05/28/2009 3.9 REFUELING OPERATIONS 3.9.1 Decay Time 08/31/1998 3.9.2 Communications 08/31/1998 3.9.3 Refueling Platform 08/31/1998 3.10 MISCELLANEOUS 3.10.1 Sealed Source Contamination 03/31/2006 3.10.2 Shutdown Margin Test RPS Instrumentation 08/01/2006 3.10.3 Independent Spent Fuel Storage Installation (ISFSI) 06/10/2010 3.10.4 Section not used 03/27/2008 SUSQUEHANNA - UNIT *J TRM/ LOES-3 EFFECTIVE DATE 12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANU~L)

Section Title Effective Date 3.11 RADIOACTIVE EFFLUENTS 3.11 :1.1 Liquid Effluents Concentration 03/31/2006 3.11.1.2 Liquid Effluents Dose 03/31/2006 3.11.'l.3 Liquid Waste Treatment System 03/31/2006 3.11.1.4 Liquid Radwaaste Effluent Monitoring Instrumentation 10/09/2012 3.11.1.5 Radioactive Liquid Process Monitoring Instrumentation 02/19/2015 3.11.2.1 Radioactive Effluents Dose Rate 03/31/2006 3.11.2.2 Dose - Noble Gases 03/31/2006 3.11.2.3 Dose - Iodine, Tritium, and Radionuclides in Particulate Form 03/31/2006 3.11.2.4 Gaseous Radwaste Treatment System 04/02/2002 3.11.2.5 Ventilation Exhaust Treatment System 06/18/2013 3.11.2.6 Radioactive Gaseous Effluent Monitoring Instrumentation 06/20/2017 3.11.3 Total Dose 03/31/2006 3.11.4:l Monitoring Program 02/19/2015 3.11.4.2 Land Use Census 03/31/2006 3.11.4.3 lnterlaboratory Comparison Program 03/31/2006 3.12 LOADS CONTROL PROGRAM 3.12.1 Crane Travel-Spent Fuel Storage Pool 02/05/1999 3.12.2 Heavy Loads Requirements 03/14/2008 3.12.3 Light Loads Requirements 02/05/1999 4.0 ADMINISTRATIVE CONTROLS 4.1 Organization Controls 08/31/1998 4.2 Reportable Event Action 08/31/1998 4.3 Safety Limit Violation 08/31/1998 4.4 Procedures and Programs 12/11/2008 4.5 Reporting Requirements 08/31/1998 4.5.1 Startup Reports 08/31/1998 4.5.2 Annual Reports 08/31/1998

  • r-,..

Spec:iai Reports

. 06/31/1998 q.,::,,.;;

4.6 Radiation Protection Program 08/31/1998 4.7 Training 08/31/1998 SUSQUEHANNA - UNIT 1 TRM / LOES-4 EFFECTIVE DATE 12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title B 3.0 B3.1 B 3.1.1 B 3.1.2 B 3.1.3 B 3.1.4 B 3.2 B 3.3 APPLICABILITY BASES REACTIVITY CONTROL SYSTEMS BASES Anticipated Transient Without Scram Alternate Rod Injection (A TWS-ARI) Instrumentation Control Rod Drive (CRD) Housing Support Control Rod Block Instrumentation Control Rod Scram Accumulators Instrumentation and Check Valve CORE OPERATING LIMITS BASES Page B 3.2-1 INSTRUMENTATION BASES Page TRM / B 3.3-1 Page TRM / B 3.3-2 Page TRM / B 3.3-2a Page TRM / B 3.3-3 Page TRM / B 3.3-3a Page TRM / B 3.3-4 Page TRM / B 3.3-5 Page TRM / B 3.3-Sa Page TRM / B 3.3-6 Page TRM / B 3.3-7 Page TRM / B. 3.3-8 Page TRM / B 3.3-9 Pages TRM / B 3.3-10 through TRM / B 3.3-12 Page TRM / B 3.3-13 Page TRM / B 3.3-14 Page TRM / 8 3.3-14a Page TRM / 8 3.3-i4b Page TRM / B 3.3-14c Pages TRivi i 8 3.3... 15 and TR~!:/ B 3.3... 16 Page TRM / 8 3.3-17 Pages TRM / B 3.3-17a through TRM / B 3.3-17c Page TRM / B 3.3-17d Effective Date 02/19/2015 04/16/2014 08/31/1998 12/15/2017 02/18/1999 08/31/1998 01/21/2014 03/10/2011 10/31/2007 12/11/2008 10/31/2007 06/30/2010 08/11/2016 06/20/2017 06/30/2010 10/07/2015 06/30/2010 10/31/2007 01/07/2011 01/21/2014 06/25/2002 11/04/2015 11/04/2015 11/04/2015 10/22/2003 03/22/200-6 03/22/2006 03/27/2008 SUSQUEHANNA - UNIT 'I TRM / LOES-5 EFFECTIVE DATE 12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNIC~L REQUIREMENTS MANUAL)

Section Title B 3.4 B 3.5 B 3.6 83.7 Pages TRM / B 3.3-17e and TRM / B 3.3-'17f Pages TRM / B 3.3-18 and TRM / B 3.3-19 Page TRM / B 3.3-20 Page TRM / B 3.3-21 Pages TRM / 8 3.3-22 and TRM / 8 3.3-23 REACTOR COOLANT SYSTEM BASES Page B 3.4-1 Pages TRM / B 3.4-2 and TRM / B 3.4-3 Pages TRM / B 3.4-4 and TRM / B 3.4-4a Page TRM / 8 3.4-5 Page B 3.4-6 Pages TRM / B 3.4-7 and TRM / B 3.4-8 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 Pages TRM / B 3.5-3 through TRM / B 3.5-5 CONTAINMENT BASES Page TRM / B 3.6-'I Page TRM / B 3.6-2 Page 8 3.6-3 Page TRM / B 3.6-4 Page TRM / B 3.6-5 Page TRM / B 3.6-6 Pages TRM / 8.3.6-7 through TRM / 8 3.6-'11 PLANT SYSTEMS BASES Pages B 3.7-i and B 3.7-2 Page TRM / B 3.7-3 Page TRM / B 3.7-3a Page TRM / B 3.7-4 Page TRrv1 I B 3~7-5 Page TRM / B 3.7-6 Pages TRM / B 3.7-7 and TRM / 8 3.7-7a Page TRM / B 3.7-8 Page TRM / B 3.7-9 Page TRM / B 3.7-10 Page TRM / B 3.7-10a Page TRM / B 3.7-11 Page TRM / 8 3.7-11a Pages TRM / B 3.7-12 and TRM / B 3.7-13 Pages TRM / B 3.7-14 and TRM / B 3.7-14a SUSQUEHANNA - UNIT 'I TRM/ LOES-6 Effective Date 03/22/2006 08/03/2010 10/22/2003 05/16/2003 04/07/2009 08/31/1998 04/01/2009 10/31/2007 10/15/1999 08/31/1998 04/25/2013 08/31/1998 10/31/2007 07/26/2001 02/01/1999 08/31/1998 03/27/2008 04/04/2007 12/03/2004 12/31/2002 08i31i1998 11/22/2016

  • j 1/22/2016 Oi/26/2017 08/02i1999 03/31/2006 08/02/1999 05/29/2013 04/11/2014 08/02/1999 03/31/2006 08/02/1999 03/31/2006 08/02/1999 09/25/2012 EFFECTIVE DATE 12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM / B 3.7-14b 11/24/2011 Pages TRM / B 3.7-15 and TRM / B 3.7-'16 02/01/'1999 Pages B 3.7-17 through B 3.7-20 08/31/1998 Page TRM / B 3.7-21 05/29/2013 Pages TRM / B 3.7-21a through TRM / B 3.7-21d 05/24/2012 Pages TRM / B 3.7-21e through TRM / B 3.7-21g 05/29/2013 Page TRM / B 3.7-22 and TRM / B 3.7-23 01/30/2008 Page TRM / 8 3.7-24 10/05/2006 Page TRM / B 3.7-25 01/21/2014 Pages TRM / B 3.7-26 through TRM / B 3.7-28 10/05/2006 Pages TRM / B 3.7-29 and TRM / B 3.7-30 06/07/2007 Page TRM / B 3. 7-30a 10/05/2006 Page TRM / B 3. 7-30b 01/21/2014 Page TRM / B 3.7-31 11/30/2011 Page TRM / B 3.7-32 03/09/2001 PageTRM / B 3.7-33 04/15/2003 Page TRM / B 3.7-34

'12/03/2004 Page TRM / B 3.7-35 07/05/2000 Pages TRM / B 3.7-36 through TRM / B 3.7-39 04/01/2009 Page TRM / B 3. 7-40 04/08/2010 B 3.8 ELECTRICAL POWER BASES Page TRM / B 3.8-1.

04/02/2002 Page TRM / B 3.8-2 01/28/2005 Page TRM / B 3.8-2a _

03/01/2010 Page TRM / B 3.8-3 04/02/2002 Page TRM / B 3.8-3a 04/02/2002 Page TRM / B 3.8-4 09/03/2004 Page TRM / B 3.8-4a 04/02/2002 Page B 3.8-5 08/31/'!998 Pages TRM / B 3.8-6 through TRM / B 3.8-15 04/02/2002 Page TRM / B 3.8-16 11/07/2013 Page TRfv1/83a8-i7 i 1i3fJ/201 ~1 Pages TRM i B 3.8-17a and TRM / B 3.8-17b 11/30/20'11 Pages TRM / 8 3.8-18 through TRM / 8 3.8-20 05/29/2013 Pages TRM / B 3.8-21 and TRM / B 3.8-22 05/28/2009 Page TRM / 8 3.8-23 05/29/2013 Page TRM / B 3.8-24 05/28/2009 8.3.9 REFUELING OPERATIONS BASES Pages B 3.9-1 through B 3.9-7 08/3'1/1998 SUSQUEHANNA - UNIT 1 TRM/ LOES-7 EFFECTIVE DA TE '12/15/2017

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 92 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.10 MISCELLANEOUS BASES Page B 3.10-1 08/31/1998 Pages TRM / B 3.10-2 and TRM / B 3.10-3 03/22/2006 Pages TRM / B 3:10-4 and TRM / B 3.10-5 08/23/1999 Page TRM / B 3.10-6 03/27/2008 B 3.11 RADIOACTIVE EFFLUENTS BASES Pages B3.11-1 through B 3.11-9 08/30/1998 Page TRM / B 3.11-10 02/01/1999 Pages TRM/8 3.11-11 and TRM/8 3.11-11a 04/07/2000 Pages TRM/8 3.11-12 and TRM/B 3.11-13 02/01/1999 Page TRM / B 3.11-14 12/03/2004 Page TRM / B 3.11-15 02/01/1999 Pages B 3.11-16 through B 3.11-19 08/30/1998 Page TRM / B 3.11-20 04/02/2002 Page TRM / B 3.11-20a 04/02/2002 Page TRM / B 3.11-21 05/13/2005 Pages TRM / B 3.11-22 and TRM / 8 3.11-23 11/14/2006 Pages TRM / B 3.11-23a and TRM / B 3.11-23b 06/18/2013 Pages TRM / B 3.11-24 and TRM / B 3.11-24a 08/11/2016 Page TRM / B 3.11-25 01/21/2004 Pages B 3.11-26 and B 3.11-27 08/30/1998 Page TRM / B 3.11-28 11/30/2005 Page TRM / B 3.11-29 02/19/2015 Pages TRM / B 3.11-30 and TRM / B 3.11-31 05/29/2013 Page TRM / B 3.11-32 08/30/1998 Page TRM / B 3.11-33 06/30/2010 Pages 8 3.11-34 and B 3.11-35 08/30/1998 Page TRM / B 3.11-36 02/12/1999 8.3.12 LOADS CONTROL PROGRAM BASES Page TRM / B 3.12-1 09/19/2007 Page TRfJi i 8 3. 12-2 1 '1/29/2010 Page TRM / B 3.12~3 02/05/1999 SUSQUEHANNA - UNIT *1 TRM / LOES-8 EFFECTIVE DATE 12/15/2017

Rev. 6 3.1 Reactivity Control Systems Control Rod Block Instrumentation 3.1.3 3.1.3 Control Rod Block Instrumentation The control rod block instrumentation for each function in Table 3.1.3-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.1.3-1 ACTIONS


NOTE ---------------------------------------------------------

Separate condition entry is allowed for each channel CONDITION REQUIRED ACTION COMPLETION TIME A. One or more required A.1 Enter the Condition referenced Immediately channels inoperable.

in Table 3.1.3-1for the channel.

B. As required by Required B.1 Place at least one inoperable 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from discovery Action A.1 and referenced channel in the tripped of loss of trip in Table 3.1.3-1.

condition.

capability AND B.2 Place the inoperable channel 7 days in the tripped condition.

C. As required by Required C. 1 Place the inoperable channel 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Action A. 'I and referenced in the tripped condition.

in Table 3.1.3-1.

D. Required Actions and D.1 Suspend Control Rod Immediately Completion Time of withdrawal.

Conditions B or C not met.

SUSQUEHANNA - UNIT 1 3.1-5 EFFECTIVE DATE 12/15/2017

Rev.6 Control Rod Block Instrumentation 3.1.3 TECHNICAL REQUIREMENT SURVEILLANCE


NOTES -------------------------------------------------------

1. Refer to Table 3.1.3-'I to determine which TRSs apply for each Control Rod Block Function.
2. Neutron detectors may be excluded from CHANNEL CALIBRATION.
3. When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided at least one other OPERABLE channel in the same trip system is monitoring that parameter.

SURVEILLANCE FREQUENCY TRS 3.1.3.1 Perform CHANNEL CHECK 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> TRS 3.1.3.2


NOTE ---------------------------

For Function 1.a, not required to be performed when entering MODE 2 from MODE 1 until 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after entering MODE 2.

Perform CHANNEL FUNCTIONAL TEST 184 days TRS 3.1.3.3 Perform CHANNEL FUNCTIONAL TEST 31 days TRS 3.1.3.4 Perform CHANNEL FUNCT!ONAL TEST 92 days TRS 3.1.3.5 Perform CHANNEL CALIBRATION 184 days


NOTE ---------------------------

Neutron detectors are excluded.

TRS 3.1.3.6 Perform CHANNEL CALIBRATION 24 months TRS 3.1.3.7 Perform LOGIC SYSTEM FUNCTIONAL TEST 24 months SUSQUEHANNA - UNIT 1 TRM / 3.1-6 EFFECTIVE DA TE 12/'15/2017

{~~~f;

Rev.6 FUNCTION Control Rod Block Instrumentation 3.1.3 TABLE 3.1.3-1 (Page 1 of2)

CONTROL ROD BLOCK INSTRUMENTATION APPLICABLE REQUIRED MODES OR OTHER CHANNELS SPECIFIED CONDITIONS CONDITIONS REFERENCED FROM REQUIRED ACTION A.1 SURVEILLANCE ALLOWABLE REQUIREMENTS VALUE

1. APRM
a. Neutron Flux -

High {Setdown)

b. Simulated Thermal Power-High
c. Downscale
d. lnop 2, 5(a) 1,2 3

3 3

3 3

B B

B B

B TRS 3.1.3.2

514% RTP TRS 3.1.3.6 TRS 3.1.3.2 0.55W+

TRS 3.1.3.6 56.2%(b)

TRS 3.1.3.2

?;3% RTP TRS 3.1.3.6 TRS 3.1.3.2 NA TRS 3.1.3.2 NA
2. Source Range Monitors
a. Detector not full in 3

2 B

B TRS 3.1.3.3 TRS 3.1.3.7 TRS 3.1.3.3 TRS 3.1.3.7 NA NA (a)

(b)

(c)

(d)

(j)

b. Upscale 3

B 2

B

c. lnop 3

B 2

B TRS 3.1.3.3 TRS 3.1.3.6 TRS 3.1.3.7 TRS 3.1.3.3 TRS 3.1.3.6 TRS 3.1.3.7 TRS 3.1.3.3 TRS 3.i.3.7 TRS 3.1.3.3 TRS 3.1.3.7

,; 3.3E5 cps
£ 3.3E5 cps NA NA

( continued)

When performing Shutdown Margin Demonstration per Technical Specification 3.10.8.

0.55 (W-/1W) + 56.2% when reset for single loop operation per LCO 3.4.1, "Recirculation Loops Operating". For single loop operation, the value of 11W = 8. 7.

When not automatically bypassed with SRM counts;:: 100 cps or the !RM channels on range 3 or higher.

When not automatically bypassed with IRM channels on range 8 or higher.

With any control rod withdrawn from a core cell containing one or more fuel assemblies.

SUSQUEHANNA - UNIT 1 TRM / 3.1-7 EFFECTIVE DATE 12/15/2017

Control Rod Block Instrumentation Rev. 6 TABLE 3.1.3-1 (Page 2 of2)

CONTROL ROD BLOCK INSTRUMENTATION APPLICABLE REQUIRED CONDITIONS MODES OR OTHER CHANNELS REFERENCED FROM SPECIFIED REQUIRED ACTION SURVEILLANCE FUNCTION CONDITIONS A.1 REQUIREMENTS

d. Downscale i*>

3 B

TRS 3.1.3.3 TRS 3.1.3.6 TRS 3.1.3.7 5(1)0) 2 B

TRS 3.1.3.3 TRS 3.1.3.6 TRS 3.1.3.7

3. Intermediate Range Monitors
a. Detector not full in 2, 50l 6

B TRS 3.1.3.3 TRS 3.1.3.7

b. Neutron Flux -

2,5© 6

B TRS 3.1.3.1 High TRS 3.1.3.3 TRS3.1.3.5 TRS 3.1.3.7

c. lnop 2, 5(i) 6 B

TRS 3.1.3.3 TRS3.1.3.7

d. Downscale i 9>50J 6

B TRS 3.1.3.1 TRS 3.1.3.3 TRS 3.1.3.5 TRS 3.1.3.7

4. Scram Discharge 1, 2, 5(h) 2 C

TRS 3.1.3.4 Volume Water Level -

TRS 3.1.3.6 High

5. Reactor Coolant (e}

(f}

(g}

(h}

(i}

0)

System Recirculation F!ovv

a. Upscale 3

C When not automatically bypassed with IRMs on range 3 or higher.

With a signal-to-noise ratio<': 2, or within the limits of TS Figure 3.3.1.2-1.

When not automatically bypassed with IRM channels on range 1.

TRS 3.1.3.2 TRS 3.1.3.6 When more than one control rod is withdrawn. Not applicable to control rods removed per Technical Specification 3.'I0.5 or 3.10.6.

Not required when eight or fewer fuel assemblies (adjacent to the SRMs) are in the core.

With any control rod withdrawn from a core cell containing one or more fuel assemblies.

3.*1.3 ALLOWABLE VALUE 21.8 cps<n 21.8 cps<n NA

,; 110/125 divisions of full scale NA 3/125 divisions of full scale
,; 36.5 gallons s 117/125 divisions of full scale SUSQUEHANNA-UNIT 1 TRM / 3:1-8 EFFECTIVE DATE 12/15/2017

~t

Rev. 13 3.7.3 3.7.3.8 Fire Protection Fire Detection Instrumentation Fire Detection Instrumentation 3.7.3.8 TRO 3. 7.3.8 The fire detection instrumentation for each fire detection zone shown in Table 3.7.3.8-1 shall be OPERABLE.

APPLICABILITY:

Whenever equipment protected by the fire detection instrument is required to be OPERABLE.

ACTIONS


NOTE ---------------------------------------------------------

1. Separate condition entry is allowed for each instrument.

CONDITION REQUIRED ACTION COMPLETION TIME A. The number of OPERABLE A.

Establish an hourly fire 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> fire detection instruments watch patrol less than the Minimum Instruments Operable AND requirement of Table 3.7.3.8-*I A.2.1 Inspect the accessible Once per hour

z:one(s) with inoperable instrument( s)

OR I

I I

,',. 2 ')

11\\..*

~ !nspect the affected area surrounding any inaccessible I 0.....--o her hr.ur I

............ f"'...,..,,....... _.

zones B. Communication between B.

Establish an hourly fire 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Control Room and a Local watch for Local Control Control Panel with local Panel Monitoring monitoring capability is not operable.

AND 8.2.1 Monitor status for the Once per hour instruments reporting to the Local Control Panel.

SUSQUEHANNA-UNIT 1 TRM / 3.7-26 EFFECTIVE DA TE 09/25/2012

Rev. 13 TECHNICAL REQUIREMENT SURVEILLANCE SURVEILLANCE Fire Detection Instrumentation 3.7.3.8 FREQUENCY


NOTE---------------------------------------------------------

Wh en a detector is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and required Actions may be delayed for up to 15 minutes to allow for the individual detector trip to clear.

TRS 3.7.3.8.1 Perform CHANNEL FUNCTIONAL TEST on 12 months accessible fire detection instruments.

TRS 3.7.3.8.2 Verify that the supervised circuits supervision 12 months associated with the detector alarms of each of the fire detection instruments listed in Table 3.7.3.8-1 are OPERABLE.

TRS 3.7.3.8.3 Perform CHANNEL FUNCTIONAL TEST on inaccessible fire detection instruments.

TRS 3.7.3.8.4 Perform CHANNEL FUNCTiONAL TEST on heat detectors fixed-temperature, non-restorable line type fire detection instrument.

SUSQUEHANNA - UNIT 1 TRM / 3.7-27 Prior to startup from each COLD SHUTDOWN exceeding 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> unless performed in the previous 12 months I 1s months EFFECTIVE DATE 12/15/2017

Rev. '13 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION 0-21A Common Equipment Room Elevator Lobby 656'-0" 0-22A 0-22A 0-22A 0-23 0-248 0-24B 0-24C 0-24D I

0-24D 0-24E 0-24E 0-24E Chem Lab OF135 High Temp. Alarm Chem Lab DS-021 Chem Lab OF138 High Temp. Alarm Chem Lab DS-022 Chem Lab OF141 High Temp. Alarm Chem Lab DS-023 Chem Lab OF144 High Temp. Alarm Chem Lab DS-024 Above Ceiling/Filter Area Elevator Lobby Egress Corridor to South Stairwell C-134 Storage (HCVS ROS Area)

Corridor Corridor Elevator Lobby UPS Panel Room U-1 U-1 Lower Relay Room 1U704 PGCC Halon Panel Division II 1U705 1U706 1U731 1U732 U-1 Lower Relay Ream Computer Room Computer Room (Above Ceiling)

Computer Room 1U720 PGCC Underfloor 1U722 1U724 1U726 SUSQUEHANNA - UNIT 1 687'-10" 687'-10" 687'-10" 687'-10" 687'-10" 687'-10" 687'-10" 687'-1 O" 687'-8" 676'-0" 686'-6" 686'-6" 698'-0" 698'-0" 698'-0" 697'-0""

697'-0" 697'-0" 697'-0'"

697'-0" 698'-0" 698'-0" 698'-0" 697'-0" 697'-0" 697'-0" 697'-0" TRM / 3.7-28 NA 2

2 2

2 2

2 2

2 NA NA NA NA NA NA 4

11 11 11 iO 11 4

NA 12 NA NA NA NA NA NA NA NA NA NA NA 2

6 6

6 5

6 2

NA 6

NA NA NA NA NA NA NA NA NA NA NA NA 10 3

1 2

6 6

6 6

6 4

6 4

4 4

4 4

NA NA NA NA NA NA NA NA 5

2 3

3 3

3 3

2 3

2 2

2 2

2 EFFECTIVE DATE 03/31/2017

Rev. 13 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION Computer Room 2U721 697'-0" NA NA 4

2 0-24E PGCC Underfloor 2U723 697'-0" NA NA 4

2 2U725 697'-0" NA NA 4

2 2U727 697'-0" NA NA 4

2 0-24F Computer Maintenance Rm and Office 698'-0" NA NA 2

0-24J South Cable Chase 698'-0" NA NA 0-24L Center Cable Chase 698'-0" NA NA 0-24M North Cable Chase 698'-0" NA NA 0-25A U-2 Lower Cable Spreading Room 714'-0" 20 10 6

3 0-25B South Cable Chase 714'-0" 1

1 NA NA 0-25C Center Cable Chase 714'-0" NA NA 0-25D North Cable Chase 714'-0" NA NA 0-25E U-1 Lower Cable Spreading Room 714'-0" 26 13 5

3 0-25E U-1 Lower Cable Spreading Room Elevator 714'-0" NA NA Lobby 0-26A Copy Room 729'-1" NA NA 0-26B South Cable Chase 729'-1" NA NA

~

0-26C Center Cable Chase 729'-1" NA NA 1

I 0-26D North Cable Chase 729'-1" NA NA i 1

0-26E Locker Room 729'-1" NA NA 0-26F I Vsstibuie Eievator Lobby 729'-1" NA NA 0-26F Vestibule (Under Floor) 728'-1" NA NA 0-26G Shift Office 729'-1" NA NA 0-26G Shift Office (Under Floor) 728'-1" NA NA 2

0-26H Control Room (Under Floor Unit 1) 728'-1" NA NA 15 8

0-26H Control Room (Under Floor Unit 2) 728'-1" NA NA 12 6

0-26H Control Room 729'-1" NA NA 10 5

0-26H Control Room (Above Ceiling) 729'-1" NA NA 9

5 0-261 Operational Support Center 729'-1" NA NA 1

SUSQUEHANNA - UNIT 1 TRM / 3.7-29 EFFECTIVE DA TE 09/25/2012

Rev. 13 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION

r
-'li\\!!lfl!W***

0-261 Operational Support Center (Under Floor) 728'-1" NA NA 2

0-26J Vestibule (Under Floor) 728'-1" NA NA D-26J Vestibule 729'-1" NA NA 0-26K Technical Support Center 741'-1" NA NA 10 5

D-26K Technical Support Center Elevator Lobby 741'-1" NA NA 0-26K Technical Support Center (Above Ceiling) 741'-1" NA NA 5

3 0-26L Conference Room 741'-1" NA NA 6

3 0-26L Conference Room (Above Ceiling) 741'-1" NA NA 2

0-26M U-1 TSC Soffit 729'-1" NA NA 2

0-26M U-1 TSC Soffit 741 '-1" NA NA 2

D-26N U-1 Control Room Soffit 741 '-1" NA NA 2

0-26P U-2 Control Room Soffit 741'-1" NA NA 2

0-26R U-2TSC Soffit 729'-1" NA NA 2

0-26R U-2 TSC Soffit 741'-1" NA NA 2

0-26S South Cable Chase 741'-1" NA NA 0-26T Center Cable Chase 741'-1" NA NA 0-26V North Cable Chase 741 '-1" NA NA 0-27B U-2 Upper Cable Spreading Room 753'-0" 24 12 5

3 0-27C U-1 Upper Cable Spreading Room 753'-0" 23 12 7

4 0-27C U-1 Upper Cable Spreading Room Elevator 753'-0" Lobby NA NA 0-27D I Electrician's Office I 754'-0" 2

I 0-27E U-1 Upper Relay Room 754'-0" 4

2 2

SUSQUEHANNA - UNIT 'I TRM /3.7-30 EFFECTIVE DA TE 09/25/2012 I I I

I I i

Rev. 13 TABLE 3. 7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION U-1 Upper Relay Room 1U700 753'-0" PGCC Halon Panel Division 1 U701 753'-0" 0-27E 1U702 753'-0" 1U703 753'-0" 1U730 753'-0" 0-27F South Cable Chase 754'-0" 0-27G Center Cable Chase 754'-0" 0-27H North Cable Chase 754'-0" 0-28A-I Equipment Room 771'-0" 0-28A-II Equipment Room 771'-0" 0-28B-I Equipment Room 771'-0" 0-28B-II Equipment Room 771'-0" 0-28B-II Equipment Room Elevator Lobby 771'-0" 0-28C Battery Room 771'-0" 0-28D Battery Room 771'-0" 0-28E Battery Room 771'-0" 0-28F Battery Room 771 '-0" 0-28G Battery Room 77*1'-0" 0-28H Repair Shop 771 '-0" 0-281 Battery Room

. 771'-0" 0-28J Battery Room 771 '-0" 0-28K 8attP,1y Room 771'-0" 0-28l Battery Room 771 '-0" 0-28M Battery Room 771 '-0" 0-28N Battery Room 771 '-0" 0-28P South Cable Chase 771 '-0" 0-28Q Center Cable Chase 771 '-0" 0-28R North Cable Chase 771'-0" 0-28T Battery Room 771'-0" 0-29A Elevator Vestibule 783'-0" 0-29B H&V Equipment Room 783'-0" SUSQUEHANNA - UNIT 1 TRM / 3.7-31 11 11 11 11 11 NA NA NA NA NA NA NA NA NA NA NA NA i\\JA NA NA NA NA NA NA NA 6

6 6

6 6

NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 6

6 6

6 6

NA NA NA 1

3 1

2 2

NA NA NA 10 3

3 3

3 3

NA NA NA 1

2 NA NA NA 5

EFFECTIVE DA TE 09/25/2012

Rev. 13 TABLE 3. 7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION

1:1:1::::::::::11:1:::ii::::::::::1::::::1:::!!I::::::1:::::::::::::::::i :::::\\:::::!I~~T~g\\¥1:~N~g~~~ftt~ijt:tJ::::: t:tttji 1

1

j:liif tl\\!i 1

iiiiil:lt!:1~1*i;~~,:~1~i 1

'.:i::]:~~~l~Ji~1t1Nlili:/ii 1i 0-30A HVAC Equipment Room 806'-0" NA NA 19 10 0-30A Freight Elevator Lobby 806'-0" NA NA 0-30A CREOASS OF125A High Temp. Alarm 806'-0" 7

4 NA NA 0-30A CREOASS DS-091 806'-0" 7

4 NA NA 0-30A CREOASS OF125B High Temp. Alarm 806'-0" 7

4 NA NA 0-30A CREOASS DS-092 806'-0" 7

4 NA NA 0-30A SGTS - OF169A High Temp. Alarm 806'-0" NA NA 0-30A SGTS - DS-093 806'-0" NA NA 0-30A SGTS - OF169B High Temp. Alarm 806'-0" NA NA 0-30A SGTS - DS-094 806'-0" NA NA 0-6G Surge Tank Vault 779'-4" NA NA 2

0-8A Refueling Floor 818'-1" NA NA 60 30 D-8A Refueling Floor Elevators 818'-1" NA NA 2

1-1A Core Spray Pump Room 645'-0" NA NA 7

4 1-1 B Core Spray Pump Room 645'-0" NA NA 5

3 1-1 B Elevator Lobby 645'-D" NA NA 1-1C HPCI Pump Room 645'-0:I 2

7 4

1-10 RCIC Pump Room 645'-0" 2

1 5

3 1-1 E RHR Pump Room 645'-D" NA NA 13 7

1-1 F RHR Pump Room 645'-0" NA NA 15 8

! i-iG I Sump Room 645 1-(Y:

NA I "'

NA 2

1-11 NW Stairway and Elevator Vestibule 676'-0" NA NA 1-2A Access Area 670'-0" NA NA 7

4 1-2B Access Area 670'-0" NA NA 9

5 1-2B Access Area Elevator Lobby 670'-0" NA NA 1-2D Remote Shutdown Panel Room 670'-0" NA NA 2

1-3A Access Area 683'-0" NA NA 9

5 1-3B-N Equipment Removal Area - North 683'-0" NA NA 8

4 1-3B-N Equipment Removal Area Elevator Lobby 683'-0" NA NA SUSQUEHANNA - UNIT *t TRM / 3.7-32 EFFECTIVE DATE 09/25/2012

Rev. 13 TABLE 3.7.3.8~1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION

@rt: ]/{jf(IflN$.ill"RUMijijif:[f4ijp'ji;)pN::::'i)\\J:!\\:@tJ:: tJ:Ut}J)()j f:f(}\\ttF?i@NNijmRQM;§Nil'P:etoo.ifJ~t::i'.rJ@tmttt 1-3B-S Equipment Removal Area - South 663'-0" NA NA 1-3B-W Equipment Removal Area - Wraparound 663'-0" NA NA 2

1-3C-N Equipment Access Area - North 663'-0" NA NA 4

2 1-3C-S Equipment Access Area - South 683'-0" NA NA 4

2 1-3C-W Equipment Access Area - Wraparound 683'-0" NA NA 5

3 IONIZATION PHOTO ELECTRIC TOTAL MIN.

TOTAL MIN.

1-4A-N Containment Access Area - North 719'-0" NA NA 11 6

4 2

1-4A-N Containment Access Area Elevator Lobby 719'-0" NA NA NA NA SMOKE TOTAL MIN.

1-4A-S Containment Access Area - South 719'-0" NA NA 10 5

1-4A-W Containment Access Area - Wraparound 719'-0" NA NA 6

3 1-4B Pipe Penetration Room 719'-1" NA NA

  • 1-4C Switchgear Room 719'-1" NA NA 2

1-4D Switchgear Room 719'-1" NA NA 2

1-4G Main Steam Pipeway 719'-1" 4*

2 NA NA 1-4G Exhaust Fan Room (Note: these detectors 799'-1" 2

also cover el. 749'-1")

NA NA IONIZATION PHOTO ELECTRIC TOTAL MIN.

TOTAL MIN.

1-5A-N I General Access Area - North 749'-1" NA NA 5

3 1

1 1-SA-N General Access Area Elevator Lobby 749'-1" NA NA NA NA 1-5A-S SLC / Chiller A;ea - South 749'-1" NA NA 15 8

7 4

SMOKE TOTAL MIN.

1-5A-W Access Corridor - Wraparound 749'-1" NA NA 7

4 1-5B Valve Access Area 761'-10" 2

1 NA NA 1-50 RWCU Pumps & Heat Exchangers 749'-1" NA NA 10 5

1-5E Penetration Room 749'-1" NA NA 2

1-SF Load Center Room 749'-1" NA NA 2

1-SG Load Center Room 749'-1" NA NA 2

1-SH Instrument Repair Shop/Sample Station 749'-1" NA NA 1-6A Access Area 779'-1" NA NA 9

5 1-6A Access Area Elevator Lobby 779'-1" NA NA 1-6B Load Center Room 779'-1" NA NA 4

2 1-6C Electrical Equipment Room 779'-1" NA NA 2

1-6D H&V Equipment Room 779'-1" NA NA 12 6

  • Inaccessible SUSQUEHANNA - UNIT 1 TRM / 3.7-33 EFFECTIVE DATE 01/26/2017 I

Rev. 13 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION 1-6E Recirculation Fans Area 779'-1" NA NA 2

1-61 Fuel Pooling Holding Pump Room 779'-1" NA NA 2

1-7A H&V Fan & Filter Rooms 799'-1" NA NA 15 8

1-7A HVAC Filter 1 F257A High Temp. Alarm 799'-1" 7

4 NA NA 1-7A HVAC Filter 1 F257A DS-181 799'-1" 7

4 NA NA 1-7A HVAC Filter 1 F257B High Temp. Alarm 799'-1" 7

4 NA NA 1-7A HVAC Filter 1 F257B DS-182 799'-1" 7

4 NA NA 1-7A HVAC Filter 1 F217A High Temp. Alarm 799'-1" 5

3 NA NA 1-7A HVAC Filter 1F217A DS-183 799'-1" 5

3 NA NA 1-7A HVAC Filter 1F217B High Temp. Alarm 799'-1" 5

3 NA NA 1-7A HVAC Filter 1 F217B DS-184 799'-1" 5

3 NA NA 0-41A Diesel Generator "A" Bay 11 2

8 710' -9" NIA NiA I NIA NIA 8

4 660'-0" &

23 12 I 2

15 8

677'-0" 0-41 B Diesel Generator "B" Bay 710' -9" NIA NIA N/A N/A 9

5 660'-0" &

22 i1 2

15 8

377'.. Q

0-41C D!ese[ '3enera.tor 11C 11 Bay 710'-9 NIA NIA NIA N/A 8

4 660'-0" &

22 11 2

15 8

677'-0" 0-410 Diesel Generator "D" Bay 710'9" N/A NIA NIA N/A 8

4 0-41E Diesel Generator Rooms 656'-6 &

1 NA NA 21 11 675'-6" &

NA NA 6

3 3

2 708'-0

NA NA 4

2 NA NA SUSQUEHANNA - UNIT *1 TRM / 3.7-34 EFFECTIVE DA TE 09/25/2012

Rev. 13 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION

=:::::ittttrni:r:::,t~ITR!M;§N]::ggg!tI@Nij[J[t:ttt:::::t:

li!ilt!l111
::iiJllil:1:::11:1:11i1:1:11111i::!iiiiil!illl:l;liiji~ll~:1~1~r:11iii:li::::i:11:1::i11111i:iji!i:1::jjiiili:::

0-00 Startup Transformer (OX103) DS-014 0-00 Startup Transformer (OX104) DS-015 0-00 ESS Transformer - DS-016 OX201 OX213 0-00 ESS Transformer-DS-017 OX203 OX211 NA NA NA NA NA NA SUSQUEHANNA - UNIT 1 TRM / 3. 7-34a 10 5

NA NA 12 6

NA NA 6

3 NA NA 6

3 NA NA 6

3 NA NA 6

3 NA NA EFFECTIVE DATE 09/25/2012

Rev.4 Control Rod Block Instrumentation B 3.1.3 B 3.1.3 Control Rod Block Instrumentation BASES TRO The Control Rod Block Instrumentation is a portion of the Reactor Manual Control System (RMCS), which upon receipt of input signals from other systems and subsystems, inhibits movement or selection of control rods (Reference 1 ). The purpose of the Control Rod Block function is to avoid conditions that would require Reactor Protection System (RPS) action if allowed to proceed.

The specific Functions associated with the TRM Contrnl Rod Block Instrumentation are identified in Table 3.1.3-1 and are discussed below.

1.
2.
3.

Average Power Range Monitors (APRM)

Source Range Monitors (SRM)

Intermediate Range Monitors (IRM)

The same grouping of neutron monitoring equipment (APRM, SRM, and !RM) that is used in the RPS is also used in the rod block circuitry. Half of the total monitors (APRM, SRM, and IRM) provide inputs to one of the two RMCS rod block logic circuits and the remaining half provide inputs to the other RMCS rod block circuit.

The APRM rod block settings are varied as a function of Reactor Coolant System (RCS) recirculation flow. The settings are selected so that all the neutron monitoring rod blocks are sufficient to avoid an RPS action.

Mechanical switches in the SRM and !RM detector drive systems provide the position signals used to indicate that a detector is not fully inserted.

The SRM minimum count rate Allowable Value is discussed in the TS Bases for SR 3.3.1.2.4.

4.

Scram Discharge Volume Water Level - High Scram Discharge Volume Water Level - High signals are provided as inputs into both rod block logic circuits. Both rod block logic circuits sense when the high water level scram trip for the Scram Discharge Volume is bypassed.

The rod block from Scram Discharge Volume Water Level - High comes from one of two float type level switches installed in each of two scram discharge instrument volumes. The second float switch in each instrument volume provides a control room annunciation of increasing level below the level at which a rod block occurs.

( continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.1-5 EFFECTIVE DATE '12/15/2017

)_'

Rev. 4 Control Rod Block Instrumentation B 3.1.3 B 3.1.3 Control Rod Block Instrumentation BASES TRO (continued)

ACTIONS TRS

5.

RCS Recirculation Flow The recirculation flow system consists of four separate transmitters on each of two recirculation loops (eight total). The transmitter output signals from one flow channel is routed to one of four APRM channels. Each APRM processes and sums the transmitter's signals. Each APRM then sends its total flow signal to both RBMs. Each RBM then compares the four flows and issues Alarms based on user entered values. Both RBM channels are identical, but are configured to support either RBM channel A or channel B.

With the NUMAC PRNMS system, the Upscale flow function is performed within the APRM and sent on to the reactor manual control system. The flow comparator is performed with the RBM. There is no separate 'inop' function from the APRM 'Upscale/lnop' and RBM 'Upscale/lnop' functions for the recirculation flow.

The ACTIONS are defined to ensure proper corrective measures are taken in response to the inoperable components.

The TRSs are performed at the specified Frequency to ensure that the Control Rod Block Function is maintained OPERABLE.

TRS 3.1.3.1, TRS 3.1.3.2, TRS 3.1.3.3, TRS 3.1.3.4, TRS 3.1.3.5, TRS 3.1.3.6, and TRS 3.1.3. 7 Control Rod Block Instrumentation surveillances are performed consistent with the Bases for the comparable channels in LCO 3.3.1.1 and LCO 3.3.1.2.

(continued)

SUSQUEHANNA - UNIT 1 TRM / B 3.1-6 EFFECTIVE DATE 12/15/2017

Rev. 4 B 3.1.3 Control Rod Block Instrumentation BASES (continued)

REFERENCE

1.

FSAR Section 7.7.1 Control Rod Block Instrumentation B 3.1.3

2.

NEDC-32410P-A, "Nuclear Measurement Analysis and Control Power Range Neutron Monitor (NUMAC PRNM) Retrofit Plus Option Ill Stability Trip Function" SUSQUEHANNA - UNIT 1 TRM/83.1-7 EFFECTIVE DATE 12/15/2017