July 17, 1995 Hr. J.

H. Goldberg

.. President - Nuclear vision Florida Power and Light Company

,P. 0.

Box 14000 Juno

Beach, Florida 33408-0420

(~

SUBJECT:

RESOLUTION OF UNRESOLVED SAFETY ISSUE (USI) A-46, SUPPLEMENT NO.

1 TO GENERIC LETTER 87-02 FOR ST.

LUCIE UNIT 1, AND TURKEY POINT UNITS 3 AND 4, (TAC NOS.

H68303, H68304 and H69483)

Dear Hr. Goldberg:

Docket Nos.

50-250, 50-251 and 50-335 cc:

See next page Distribution CDockat @le; PDII-1 RF PUBLIC SVarga OGC ACRS (4)

KLandis, RII RWessman GBagchi To receive a copy of this docunent, indicate in the box C-"Copy u/o attachment/enclosure E=Copy with attachment/enclosure II ~ Ho copy l

In our letter dated February 9,

1995, we provided our evaluation of your scaled-back program to resolve the primary concern of USI A-46, "Seismic qualification of Equipment in Operating Plants."

Several areas of concern were identified which required further evaluation before a final determination can be reached regarding the overall program adequacy.

We stated our intent to conduct site inspections in order to fully evaluate your USI A-46 program implementation, with special emphasis on the concerns noted in our Safety Evaluation dated February 9, 1995.

In a letter dated June 13, 1995, Hr.'W.H. Bohlke proposed a two day technical working meeting in Washington to resolve our remaining concerns, citing a cost savings of approximately

$ 200,000. 'n response t'o Hr. Bohlke's,letter, we discussed the available options with';your staff on June"27;, 1995,'nd have agreed that a one week audit of,.your..program should, be adequate'to resolve the remaining issues.

The audit team, will be'"made: up of jthree,,individuals and the audit will be conducted during the week of. December '4",,~l'995.;,-'The audit will be performed at your'uno Beach o'ffice and'at the Turkey Point site.

We are available for pre-audit meetings" on thi"s issue.,'A site visit by one individual prior to the audit Tis'expected to gather,'~preparatory",information and examine equipment during the upcoming outage which may'not be'vailable during power operation duritig the ~December;audit."

If you have any questions regarding, this m'atter,;, please'contact us at (301) 415-1475 or (301)-415-1483.

I

~'.',," Sincerely',

(Original Signed By)

(Orig':nal Signed By)

Jan Norris, Sr. Project Manager Richard P. Croteau, Project Manager Project Directorate II-1 Project Directorate II-1 Division of Reactor Projects - I/II Division 'of Reactor Projects - I/II Office of Nuclear Reactor Regulation Office'f Nuclear Reactor Regulation OFFICE NAHE DATE LA:PDI I-1 EDunnin ton

'7 t

95 PH: PDI I-1 RCrotea~

1 95 J or i

/

't95 EHEB KManoly 7

14 95 DHatthews ECGB GBa chi 7

14 95

  • see previous concurrence OFFICIAL RFCORD COPY -

DOCUMENT NAME: G:iTURKEYiTP68303. I 9507190228 950717 t

PDR ADOCK 05000250 P

PDR

~'A 1

'H 8

I

~ a>>

I(

Flor>ida Power and Light Company CC:

Jack Shreve, Public Counsel Office of the Public Counsel c/o The Florida Legislature 111 West Madison Avenue, Room 812 Tallahassee, Florida 32399-1400 Senior Resident Inspector St.

Lucie Plant U.S. Nuclear Regulatory Commission 7585 S.

Hwy AlA Jensen

Beach, Florida 34957 Hr. Joe Hyers, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 J.

R.

Newman, Esq.
Morgan, Lewis

& Bockius 1800 M Street, NW Washington, DC 20036 John T. Butler, Esq.

Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Hr. Thomas R.L. Kindred County Administrator St.

Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982 Hr. Charles B. Brinkman, Manager Washington Nuclear Operations ABB Combustion Engineering Nuclear Power 12300 Twinbrook Parkway, Suite 330 Rockville, Maryland 20852 St.

Lucie Plant (1&2)

Turkey Point (3&4)

Hr. Bill Passetti Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.

Tallahassee, Florida 32399-0700 Regional Administrator, RII U.S. Nuclear Regulatory Commission 101 Harietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Mr. H.

N. Paduano, Manager Licensing

& Special Programs Florida Power and Light Company P.O.

Box 14000 Juno

Beach, Florida 33408-0420 D. A. Sager, Vice President St. Lucie Nuclear Plant P.O.

Box 128 Fort Pierce, Florida 34954-0128 C. L. Burton Plant General Manager St.

Lucie Nuclear Plant P.O.

Box 128 Fort Pierce, Florida 34954-0128 Hr. J.

H. Goldberg President Nuclear Division Florida Power and Light Company P.O.

Box 14000 Juno

Beach, Florida 33408-0420 Hr. Thomas F. Plunkett Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company P.O.

Box 029100 Hiami, Florida 33102 (cont.)

~

S Tl

~

~

Florida Power and Light Company CC:

Hr.

Edward J.

Weinkam Licensing Manager Turkey Point Nuclear Plant PRO.

Box 4332 Princeton, Florida 33032-4332 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Joaquin Avino County Manager of Metropolitan Dade County 111 NW 1st Street, 29th Floor Miami, Florida 33128 St.

Lucie Plant (182)

Turkey Point (354)

Senior Resident Inspector Turkey Point Nuclear Generating Station U.S. Nuclear Regulatory Commission P.O.

Box 1448 Homestead, Florida 33090 Plant Manager Turkey Point Nuclear Plant Florida Power and Light Company P.O.

Box 029100 Miami, Florida 33102 Hr. Robert E,

Dawson Plant Licensing Manager St.

Lucie Nuclear Plant P.O.

Box 128 Fort Pierce, Florida 34954-0128