Application for Amends to Licenses DPR-31 & DPR-41,App a, Addressing Operability & Surveillance of Facility Overpressure Mitigating Sys
ML17340A908
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 03/10/1981
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17340A909 List:
References
L-81-110, NUDOCS 8104010099
Download: ML17340A908 (7)


Text

ACCESSION hiBR:R104010099 DOC,DATE: 81/03/10 NOTARIZED: YKS DOCKET FACIL:50-250 Turkey Point Planti Unit 3r. Florida Power and Light C 050 0 SO SO-2B1 Turkey Point Plantr Unit Qr Florida Power and Lignt AUTH ~ INAMF AUTHOR AFFILIATION C

+ 002 UHRIGr R ~ E ~ Flor ida Power 8 Light Co ~

REC IP. VA lE RECIPIENT AFFII IATION SUB.JECT: Apolication for amends to Licenses DPR 31 8 OPR 0 lrApp A) addressing operability 8, surveillance of facility o~erpr essure mitigating sys.

DISTRISUTIDR CODE: ii00lS COPIES RECEIVED:LTR QERCLQ SIZE:

TITLE: General Distribution for after Issuance of Operating License NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL IO COOK/hiAhlE LTTR ENCL ACTION: VARGARS ~ 0q 13 13 INTERNAL '/O IR R HUIS F AC 0B Oo 1 1 2

DIRE DIV OF LIC, hlRC POR 02 1

1 1

1 OKLD 11 1 0 OR ASSESS BR 10 1 0 01 1 1 K',IrTKRhlAL: AC RS 09 1o 16 LPOR 03 1 r 1 I" SIC 05 1 1 TOTAL hiU'DiBER OF COP IES RKvUiREO: LTTR 39 ENCL 37

6,p

,O. SOX 529100 MIAMI,FL 33152 e

FLORIDA POWER 8 LIGHT COMPANY t1arch 10, 1981 Office of Nuclear Reactor Regulation Attention: Mr. Darrell G- Eisenhut, Director U. S.

Division of Licensing Nuclear Regulatory Commission g L-81-110 a- '1 .(i Washington, D. C- 20555' Dear Mr. Eisenhut1 Re1 Turkey Point Units 3 & 4

~CL~ ee Docket Nos- 50-250 and 50-251 Proposed license Amendment Over Pressure Miti atin S stem In accordance with 10 CFR 50.30, Florida Power & Light Company submits herewith three signed originals and forty copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41. This submittal has been prepared in response to a July 19, 1978 letter from Mr. A. Schwencer.

The proposed amendment, which addresses the operability and surveillance of the Turkey Point Units 3 and 4 Overpressure Mitigating System (OMS) is described below and shown on the accompanying Technical Specification pages bearing the date of this letter in the lower right hand corner.

~Pa e 1-6 New definition 1.18 addressing RCS pressure boundary integrity.

Pa e 3.15-1 The OMS limiting conditions for operation in Specification 3.15 are 55 to DPR 31 and Amendment 47 to DPR 41 require that power be revised'mendment removed from certain valves. This would, however, disable valve position indication, reducing operation awareness of conditions and requiring containment entry for the required valve position surveillance. An alternative means of increasing assurance of proper valve position has been added-Pa e 4.16-1 New Specification 4.16 give the OMS surveillance requirements.

(At the staff's request, additional surveillance on the presssurizer power operated relief valves'ackup air supply has been added.)

o</

5 pg+gog PEOPLE... SERVING PFOPLE

Of f ic e of Nuclear Reactor Regulation Attention: Mr. Darrell G. Eisenhut Page 2 A typographical error is corrected in the Bases.

The proposed amendment has been reviewed by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 6 Light Company Nuclear Review Board. Implementation of the OMS at both Turkey Point units was completed during the Spring, 1979 refueling outages.

Very truly yours, Robert E. Uhrig Vice President REU/PLP/ras Attachment cc: Mr. James P. O'Reilly, Region II Harold F. Reis, Esquire

~1 STATE OF FLORIDA )

) ss COUNTY OF DADE )

Robert E. Uhrig being firstiduly sworn, deposes and says:

That he is Vice President of Florida Power &

Light Company, the Licensee herein; That he has executed the foregoing. document; tha" the state-ments made in this said document are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said Licensee.

Subscribed and sworn to before me this NOTARY PUBLIC, State of Florida i and for the County of Dade,

".ct~rY p""::~, s!"1o Of .":erma ~t L~r-e My commission expires: