ML17321A033

From kanterella
Jump to navigation Jump to search

Additional Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Revision 1, Clarification of Rod Position Requirements (WBN-TS-16-025)
ML17321A033
Person / Time
Site: Watts Bar  
Issue date: 11/16/2017
From: James Shea
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CNL-17-143
Download: ML17321A033 (13)


Text

Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-17-143 November 16, 2017 10 CFR 50.90 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF-90 NRC Docket No. 50-390 Watts Bar Nuclear Plant, Unit 2 Facility Operating License No. NPF-96 NRC Docket No. 50-391

Subject:

Additional Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Revision 1, Clarification of Rod Position Requirements (WBN-TS-16-025)

References:

1. TVA letter to NRC, CNL-16-148, Application to Revise Technical Specifications to Adopt TSTF-547, Revision 1, Clarification of Rod Position Requirements (WBN-TS-16-025), dated November 23, 2016 (ML16335A179)
2. Technical Specification Task Force (TSTF) letter to NRC, TSTF Comments on Draft Model Safety Evaluation of Traveler TSTF-547, Revision 0, Clarification of Rod Position Requirements, and Transmittal of TSTF-547, Revision 1, dated December 31, 2015 (ML15365A610)
3. NRC letter to TSTF, Final Safety Evaluation of Technical Specifications Task Force Traveler TSTF-547, Revision 1, Clarification of Rod Positon Requirements (TAC No. MF3570), dated March 4, 2016 (ML16012A130 and ML15328A350)
4. TVA letter to NRC, CNL-17-123, Supplement to Application to Revise Technical Specifications to Adopt TSTF-547, Revision 1, Clarification of Rod Position Requirements (WBN-TS-16-025), dated September 29, 2017 (ML17272A955)

U. S. Nuclear Regulatory Commission CNL-17-143 Page 2 November 16, 2017 In Reference 1, the Tennessee Valley Authority (TVA) submitted a request for an amendment to the Technical Specifications (TS) for the Watts Bar Nuclear Plant (WBN),

Units 1 and 2. The proposed amendment revises the requirements on control and shutdown rods, and rod and bank position indication in accordance with Technical Specification Task Force (TSTF)-547, Revision 1, "Clarification of Rod Position Requirements" (References 2 and 3). In Reference 4, TVA submitted a supplement to the license amendment request (LAR) to revise WBN Units 1 and 2 TS 3.1.6 and 3.1.7 to add the plant specific number of steps for control rod movement for consistency with WBN Units 1 and 2 SR 3.1.5.2. For completeness, this supplement contained all of the proposed changes to the WBN Units 1 and 2 TS and Bases and superseded those provided in Reference 1.

On November 1, 2017, NRC informed TVA that some of the proposed TS changes in References 1 and 4 were not identified as changes in TSTF-547, Revision 1. For example, Required Action A.1.1 for TS 3.1.5, "Rod Group Alignment Limits," was changed from "Verify SOM is~ 1.6% b.k/k" to "Verify SOM to be within the limits specified in the COLR."

While this change is consistent with the Westinghouse Standard Technical Specifications (NUREG-141, Revision 4), it was not identified as a change in the TSTF. TVA has entered this error into our corrective action program.

TVA has compared the TS changes in Reference 4 to those in TSTF-547, Revision 1 and is supplementing Attachment 1 to Reference 1 to address those TS changes that deviate from the TS changes in TSTF-547, Revision 1. The revised Attachment 1 to this submittal also includes the information in Reference 4 and supersedes the Attachment 1 in Reference 1.

No further changes to the TS, as provided in Reference 4, are required.

This response does not change the no significant hazards considerations determination contained in Reference 1. Attachment 2 contains the new regulatory commitment associated with this submittal. Please address any questions regarding this request to Edward D. Schrull at (423) 751 -3850.

I declare under penalty of perjury that the foregoing is true and correct Executed on this 16th day of November 2017.

. Shea e President, Nuclear Regulatory Affairs and Support Services Attachments:

1. Description and Assessment
2. New Regulatory Commitment cc: See Page 3

U. S. Nuclear Regulatory Commission CNL-17-143 Page 3 November 16, 2017 cc (Attachments):

NRC Regional Administrator - Region II NRC Senior Resident Inspector - Watts Bar Nuclear Plant NRC Project Manager - Watts Bar Nuclear Plant Director, Division of Radiological Health - Tennessee State Department of Environment and Conservation (w/o attachments)

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-1 of 9

1.0 DESCRIPTION

The proposed amendment revises the requirements on control and shutdown rods, and rod and bank position indication in the Watts Bar Nuclear (WBN) Plant, Unit 1 and Unit 2 Technical Specification (TS) 3.1.5, "Rod Group Alignment Limits," TS 3.1.6, "Shutdown Bank Insertion Limits," TS 3.1.7, "Control Bank Insertion Limits," and TS 3.1.8, "Rod Position Indication." The proposed amendment provides time to repair rod movement failures that do not affect rod Operability, to provide time for analog position indication instruments to read accurately after rod movement, to correct conflicts between the TS, to eliminate an unnecessary action, and to increase consistency and to improve the presentation.

2.0 ASSESSMENT

2.1 Applicability of Safety Evaluation The Tennessee Valley Authority (TVA) has reviewed the safety evaluation for Technical Specifications Task Force 547 (TSTF-547), Revision 1 provided to the TSTF in a letter dated March 4, 2016. This review included a review of the Nuclear Regulatory Commission (NRC) staffs evaluation, as well as the information provided in TSTF-547, Revision 1. As described in the subsequent paragraphs, TVA has concluded that the justifications presented in the TSTF-547, Revision 1 proposal and the safety evaluation prepared by the NRC staff are applicable to WBN Unit 1 and Unit 2, and justify this amendment for the incorporation of the changes to the WBN Unit 1 and Unit 2 TS.

2.2 Variations TVA is proposing the following minor variations from the TS changes described in TSTF-547, Revision 1. These variations do not affect the applicability of TSTF-547, Revision 1 or the NRC staff's safety evaluation to the proposed license amendment.

1. The WBN Unit 1 and Unit 2 TS utilize different numbering than the Standard Technical Specifications on which TSTF-547, Revision 1 was based. The following table summarizes the differences between the WBN Unit 1 and Unit 2 TS numbering and the TSTF-547, Revision 1 numbering.

TSTF-547, Rev. 1 WBN Unit 1 WBN Unit 2 TS 3.1.4, "Rod Group Alignment Limits" TS 3.1.5, "Rod Group Alignment Limits" TS 3.1.5, "Rod Group Alignment Limits" TS 3.1.5, "Shutdown Bank Insertion Limits" TS 3.1.6, Shutdown Bank Insertion Limits TS 3.1.6, Shutdown Bank Insertion Limits TS 3.1.6, "Control Bank Insertion Limits" TS 3.1.7, "Control Bank Insertion Limits" TS 3.1.7, "Control Bank Insertion Limits" TS 3.1.7, "Rod Position Indication" TS 3.1.8, "Rod Position Indication" TS 3.1.8, "Rod Position Indication"

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-2 of 9 The use of different numbering does not affect the applicability of TSTF-547, Revision 1 to the WBN Unit 1 and Unit 2 TS.

2. TSTF-547, Revision 1, TS 3.1.7, Rod Position Indication, Required Actions A.1 and C.1 discuss indirect verification of rod position by using movable incore detectors when the rod position indication system is inoperable. As described in Section 7.7.1.9 of the WBN Dual Unit Updated Final Safety Analysis Report, WBN Unit 1 and Unit 2 have a power distribution monitoring system (PDMS) that can be utilized to obtain a three-dimensional power distribution measurement to indirectly provide rod position verification.

WBN Unit 1 has the ability to indirectly verify rod position utilizing either a movable incore system or the PDMS (References 1 and 2). WBN Unit 2 uses the fixed incore system as input to PDMS to indirectly verify rod position (Reference 3). Accordingly, the proposed WBN Unit 1 and Unit 2 TS 3.1.8, Rod Positon Indication and associated TS Bases refer to utilizing the PDMS or moveable incore detectors for WBN Unit 1 and the PDMS for WBN Unit 2 in order to provide indirect verification of rod position for an inoperable rod indicator.

TVA has determined that the variation from TSTF-547 to continue allowing the use of the PDMS to indirectly verify rod position does not affect the applicability of TSTF-547, Revision 1 to the WBN Unit 1 and Unit 2 TS.

3. TSTF-547, Revision 1, Surveillance Requirement (SR) 3.1.4.3 contains a value for Tavg of 500oF, whereas the current WBN value (in SR 3.1.5.3) is 551oF. The temperature of 551oF represents a WBN Unit 1 plant-specific historical artifact of the licensing evolution process as the WBN Unit 1 TS transitioned from NUREG-0452, Revision 4 to NUREG-1431, Revision 0 (the Westinghouse Standard Technical Specifications), which kept the value at 551oF. The SR to demonstrate rod drop time was initially based on performing the test with all reactor coolant pumps operating and the average moderator temperature 551oF to simulate a reactor trip under actual conditions. WBN Unit 2 also specifies the 551oF temperature.

TVA has determined that the variation of the temperature specified in SR 3.1.4.3 (TVA proposed SR 3.1.5.3) is consistent with the current licensing basis of the plants and does not affect the applicability of TSTF-547, Revision 1 to the WBN Unit 1 and Unit 2 TS.

4. Incorporation of specific WBN minor format variations:

Indentation of OR between TS 3.1.5, Required Action B.1.1 and B.1.2.

Addition of the word overlap in TS 3.1.7, Required Action A.3, which was inadvertently left out of the TSTF-547 template. Note that the word overlap is correctly contained in and consistent with Limiting Condition for Operation (LCO) 3.1.7, TS 3.1.7 Conditions A. and C., TS 3.1.7 Required Action C.2, and SR 3.1.7.3.

These differences are administrative and do not affect the applicability of TSTF-547, Revision 1 to the WBN Unit 1 and Unit 2 TS.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-3 of 9

5. The proposed changes to the TS pages for Condition A of WBN Unit 1 and Unit 2 TS 3.1.6 and TS 3.1.7 replace the bracketed inserted 16 steps with inserted 10 steps. As noted in TSTF-547, Revision 1, and the NRC Safety Evaluation (Reference 4), the number 16 is bracketed and it is to be replaced with the plant-specific minimum number of steps that the rods must be moved to perform SR 3.1.5.2. As noted in Item 1, TS 3.1.4 in TSTF-547, Revision 1 corresponds to WBN Units 1 and 2 TS 3.1.5. Correspondingly, WBN Units 1 and 2 SR 3.1.5.2 states Verify rod freedom of movement (trippability) by moving each rod not fully inserted in the core 10 steps in either direction. Therefore, the proposed changes to WBN Unit 1 and Unit 2 TS 3.1.6 and 3.1.7 are consistent with WBN Units 1 and 2 SR 3.1.5.2. As noted in the Bases for WBN Units 1 and 2 SR 3.1.5.2, Moving each control rod by 10 steps will not cause radial or axial power tilts, or oscillations, to occur. The number of steps in WBN Units 1 and 2 SR 3.1.5.2 is also consistent with SR 3.1.4.2 in the Westinghouse Standard TS (STS) in NUREG-1431, Revision 4, Standard Technical Specifications Westinghouse Plants.
6. The following TS changes are consistent with the Westinghouse STS, but are not identified as changes in TSTF-547, Revision 1.

WBN 1 and 2 TS Description of Change Justification 3.1.5 Limiting Condition for Operation (LCO)

Changed All shutdown and control rods shall be OPERABLE., with all individual indicated rod positions within 12 steps of their group step counter demand position to All shutdown and control rods shall be OPERABLE AND Individual indicated rod positions shall be within 12 steps of their group step counter demand position This change is consistent with the Westinghouse STS and is editorial in nature to clarify the applicability of the LCO.

3.1.5, Condition A Changed one or more rod(s) untrippable to one or more rod(s) inoperable This change is consistent with the Westinghouse STS and TSTF-9-A, Revision 1.

3.1.5, Required Action B.4 Added SR 3.2.1.2 This change is consistent with the Westinghouse STS and the current WBN TS Bases B3.1.5, Actions B.2.2, B.2.3, B.2.4, B.2.5, and B.2.6.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-4 of 9 WBN 1 and 2 TS Description of Change Justification 3.1.5, Required Actions A.1.1, B.1.1, B.3, and D.1.1 3.1.6, Required Action B.1.1 3.1.7, Required Actions B1.1 and C.1.1 Verify SDM is 1.6% k/k was changed to Verify SDM to be within the limits specified in the Core Operating Limits Report (COLR).

This change is consistent with the Westinghouse STS and TSTF-9-A, Revision 1, Relocate value for shutdown margin to COLR (Reference 5), which was approved by NRC in Reference 6.

The COLR process reduces the burden on the licensees and the NRC from processing changes to cycle-specific parameter limits in TSs for each fuel cycle, provided the limits are developed using an NRC approved methodology.

TVA will revise the COLR for WBN Units 1 and 2 to relocate the shutdown margin (SDM) limits in the following Technical Specifications to the COLR:

3.1.5, "Rod Group Alignment Limits" 3.1.6, "Shutdown Bank Insertion Limits" 3.1.7, "Control Bank Insertion Limits" SR 3.1.5.3 Revised the frequency from Prior to reactor criticality after initial fuel loading and each removal of the reactor head to Prior to criticality after each removal of the reactor head This change is consistent with the Westinghouse STS. Initial fuel loading has been completed for WBN Units 1 and 2.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-5 of 9 WBN 1 and 2 TS Description of Change Justification 3.1.6 The Applicability Statement was revised from:

MODE 1, MODE 2 with any control bank not fully inserted.

to MODES 1 and 2 This change is consistent with the Westinghouse STS and TSTF-239-A, Revision 0, Correct shutdown bank insertion limits applicability (Reference 7). As noted in TSTF-239, NUREG-1431, LCO 3.1.6, Shutdown Bank Insertion Limits, is applicable in Mode 1 and Mode 2 with any control bank not fully inserted.

Since the reactor must be critical to be in Mode 2 and the control banks must be withdrawn to be critical, the qualification on the Mode 2 Applicability is meaningless and confusing.

Therefore, the Applicability is changed to simply Mode 1 and Mode 2. This does not result in any actual change to the requirements but simplifies the specifications. Appropriate Bases changes were also made.

SR 3.1.6.1 (Unit 1 only)

The surveillance was revised to add insertion between the and limits This is change is consistent with the WBN Unit 2 TS and the Westinghouse STS.

3.1.7, Required Action D.1 Revised Be in MODE 3 to Be in MODE 2 with keff < 1.0.

This change is consistent with the current Applicability Statement for TS 3.1.7 and the Westinghouse STS.

Therefore, TVA is not proposing any significant variations or deviations from the TS changes described in TSTF-547, Revision 1 or the applicable parts of the NRC staffs Safety Evaluation.

The Traveler and safety evaluation discuss the applicable regulatory requirements and guidance, including the 10 CFR 50, Appendix A, General Design Criteria (GDC). WBN Unit 1 and Unit 2 were designed to meet the intent of the Proposed General Design Criteria for Nuclear Power Plant Construction, published for comment in the Federal Register on July 11, 1967 (32 FR 10213). The WBN Unit 1 and Unit 2 construction permit was issued in January 1973. UFSAR Section 3.1, Conformance with NRC General Design Criteria, addresses the NRC General Design Criteria published as Appendix A to 10 CFR 50 in July 1971, including Criterion 4 as amended October 27, 1987. This difference does not alter the conclusion that the proposed change is applicable to WBN Unit 1 and Unit 2.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-6 of 9

3.0 REGULATORY ANALYSIS

3.1 No Significant Hazards Consideration Analysis TVA requests adoption of TSTF-547, Revision 1, "Clarification of Rod Position Requirements," which is an approved change to the Standard Technical Specifications, into the Watts Bar Nuclear Plant, Unit 1 and Unit 2 Technical Specifications (TS). The proposed change revises the requirements on control and shutdown rods, and rod and bank position indication to provide time to repair rod movement failures that do not affect rod Operability, to provide time for analog position indication instruments to read accurately after rod movement, to correct conflicts between the TS, to eliminate an unnecessary action, and to increase consistency and to improve the presentation.

TVA has evaluated whether or not a significant hazards consideration is involved with the proposed amendment(s) by focusing on the three standards set forth in 10 CFR 50.92, "Issuance of amendment," as discussed below:

1.

Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No Control and shutdown rods are assumed to insert into the core to shut down the reactor in evaluated accidents. Rod insertion limits ensure that adequate negative reactivity is available to provide the assumed shutdown margin (SDM). Rod alignment and overlap limits maintain an appropriate power distribution and reactivity insertion profile.

Control and shutdown rods are initiators to several accidents previously evaluated, such as rod ejection. The proposed change does change the limiting conditions for operation for the rods and makes technical changes to the Surveillance Requirements (SRs) governing the rods. However, the proposed change has no significant effect on the probability of any accident previously evaluated.

Revising the TS Actions to provide a limited time to repair rod movement control has no effect on the SDM assumed in the accident analysis as the proposed Action require verification that SDM is maintained. The effects on power distribution will not cause a significant increase in the consequences of any accident previously evaluated as all TS requirements on power distribution continue to be applicable.

Revising the TS Actions to provide an alternative to frequent use of the moveable incore detector system to verify the position of rods with inoperable rod position indicator does not change the requirement for the rods to be aligned and within the insertion limits.

Therefore, the assumptions used in any accidents previously evaluated are unchanged and there is no significant increase in the consequences.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-7 of 9 The consequences of an accident that might occur during the 1-hour period provided for the analog rod position indication to stabilize after rod movement are no different than the consequences of the accident under the existing actions with the rod declared inoperable.

The proposed change to resolve the conflicts in the TS ensure that the intended Actions are followed when equipment is inoperable. Actions taken with inoperable equipment are not assumptions in the accidents previously evaluated and have no significant effect on the consequences.

The proposed change to eliminate an unnecessary action has no effect on the consequences of accidents previously evaluated as the analysis of those accidents did not consider the use of the action.

The proposed change to increase consistency within the TS has no effect on the consequences of accidents previously evaluated as the proposed change clarifies the application of the existing requirements and does not change the intent.

Therefore, the proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.

2.

Does the proposed amendment create the possibility of a new or different kind of accident from any previously evaluated?

Response: No The proposed change does not involve a physical alteration of the plant (i.e., no new or different type of equipment will be installed). The change does not alter assumptions made in the safety analyses. The proposed change does alter the limiting conditions for operation for the rods and makes technical changes to the SRs governing the rods. However, the proposed change to actions maintains or improves safety when equipment is inoperable and does not introduce new failure modes.

Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.

3.

Does the proposed amendment involve a significant reduction in a margin of safety?

Response: No The proposed change to allow time for rod position indication to stabilize after rod movement and to allow an alternative method of verifying rod position has no effect on the safety margin as actual rod position is not affected. The proposed change to provide time to repair rods that are Operable but immovable does not result in a significant reduction in the margin of safety because all rods must be verified to be Operable, and all other banks must be within the insertion limits. The remaining proposed changes to make the requirements internally consistent and to eliminate unnecessary actions do not affect the margin of safety as the changes do not affect the ability of the rods to perform their specified safety function.

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-8 of 9 Therefore, the proposed change does not involve a significant reduction in a margin of safety.

Based on the above, TVA concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

3.2 Conclusions In conclusion, based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commissions regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

4.0 ENVIRONMENTAL EVALUATION The proposed change would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed change does not involve (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluents that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure.

Accordingly, the proposed change meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9).

Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed change.

5.0 REFERENCES

1. NRC letter to TVA, Watts Bar Nuclear Plant Unit 1 - Issuance of Amendment Regarding the Application to Implement BEACON Core Power Distribution and Monitoring System (TAC No. ME1698), dated October 27, 2009 (ML092710381)
2. NRC letter to TVA, Watts Bar Nuclear Plant Unit 1 - Issuance of Amendment Regarding Alternate Means for Monitoring Control or Shutdown Rod Positions (TAC No. MC1419) (WBN-TS-03-12), dated September 20, 2005 (ML052300162)
3. Watts Bar Nuclear Plant Unit 2, Technical Specification 3.1.8, Rod Positon Indication, Facility Operating License No. NPF-96, dated October 22, 2015 (ML15251A587)
4. NRC letter to TSTF, Final Safety Evaluation of Technical Specifications Task Force Traveler TSTF-547, Revision 1, Clarification of Rod Positon Requirements (TAC No. MF3570), dated March 4, 2016 (ML16012A130 and ML15328A350)
5. TSTF-9-A, Revision 1, Relocate value for shutdown margin to COLR, dated January 8, 1996 (ML040400130)
6. NRC letter to Nuclear Energy Institute dated September 27, 1996 (Legacy Accession Number 9610030183)

ATTACHMENT 1 - DESCRIPTION AND ASSESSMENT CNL-17-143 A1-9 of 9

7. TSTF-239-A, Rev. 0, Correct shutdown bank insertion limits applicability, dated February 5, 1998 (ML040611057)

ATTACHMENT 2 New Regulatory Commitment CNL-17-143 A2-1 of 1 Commitment Due Date/Event TVA will revise the Core Operating Limits Report (COLR) for WBN Units 1 and 2 to relocate the shutdown margin (SDM) limits in the following Technical Specifications to the COLR:

3.1.5, Rod Group Alignment Limits 3.1.6, Shutdown Bank Insertion Limits 3.1.7, Control Bank Insertion Limits Within 60 days following NRC approval of License Amendment Request WBN-TS-16-025 (TVA letters CNL-16-148 and CNL-17-123)