PNP 2017-062, Submittal of 2017 Refueling Outage, 1R25, 180-Day Steam Generator Tube Inspection Report
| ML17291A006 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 10/18/2017 |
| From: | Hardy J Entergy Nuclear Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| PNP 2017-062 51-9275005-000 | |
| Download: ML17291A006 (73) | |
Text
e E l-e-=--. ntetgY.
PNP 2017-062 October 18, 2017 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
SUBJECT:
2017 Steam Generator Tube Inspection Report Palisades Nuclear Plant Docket 50-255 Renewed Facility Operating License No. DPR-20
Dear Sir or Madam:
Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043-9530 Tel 269 764 2000 Jeffery A. Hardy Regulatory Assurance Manager Entergy Nuclear Operations, Inc. is providing the enclosed 2017 steam generator tube inspection report in accordance with Palisades Nuclear Plant Technical Specifications Section 5.6.8, Steam Generator Tube Inspection Report. The specification requires that the report be submitted within 180 days after initial entry into mode 4 following completion of the inspection.
Mode 4 was entered on May 15, 2017.
This letter contains no new commitments and no revised commitments.
Sincerely, JAH/jpm
Attachment:
Palisades 2017 Refueling Outage, 1 R25, 180-Day Steam Generator Tube Inspection Report, AREVA Inc., Engineering Information Record, Document No.:
51-9275005-000 cc:
Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC
ATTACHMENT Palisades 2017 Refueling Outage, 1 R25 180-Day Steam Generator Tube Inspection Report AREVA Inc.
Engineering Information Record Document No.: 51-9275005-000 71 pages follow
ATIACHMENT 1 to AREVA-17-Q2174 A.
20004-022 (03/10/2016)
AREVA AREVA Inc.
Engineering Information Record Document No.:
51 9275005 -
000
--~--~~~~~~--
Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Page 1 of71
ATTACHMENT 1 to AREVA-17-02174 A
AREVA 20004-022 (0311 0/2016)
Document No.: 51-9275005-000 Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Safety Related?
IX] YES D NO Does this document establish design or technical requirements? D YES
~
NO Does this document contain assumptions requiring verification? D YES
~
NO Does this document contain Customer Required Format? D YES IX! NO Signature Block Pages/Sections Name and P/LP, RlLR, M, Prepared/Reviewed/
Title/Discipline Signature A-CRF, A Date Approved or Comments Victor Newman VPNEWMAN P
Principal Engineer 911112017 Craig Kelley ClKELLEY R
Supervisory Engineer 9111/2017 James Campbell lPCAMPBELL A
Technical Manager, 9112/2017 C&SE Note: PILP designates Preparer (P), Lead Preparer (LP)
M designates Mentor (M)
RlLR designates Reviewer (R), Lead Reviewer (LR)
All All All A-CRF designates Project Manager Approver of Customer Required Format (A-CRF)
A designates ApproverlRTM - Verification of Reviewer Independence Project Manager Approval of Customer References (Nt A if not applicable)
Name Title (printed or typed)
(printed or typed)
Signature Paul Ulmer Project Manager PM ULMER 911212017 Date Page 2
A.
AREVA Revision No.
000 ATTACHMENT 1 to AREVA-17-02174 20004-022 (03/10/2016)
Document No.: 51-9275005-000 Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Record of Revision Pages/Sections/
Paragraphs Changed Brief Description / Change Authorization N/A Original Issue Page 3
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Table of Contents Page SIGNATURE BLOCK................................................................................................................................ 2 RECORD OF REVISION.......................................................................................................................... 3 LIST OF TABLES..................................................................................................................................... 5 LIST OF FIGURES................................................................................................................................... 6 1.0 PURPOSE..................................................................................................................................... 7 2.0 ASSUMPTION.............................................................................................................................. 7 3.0 INPUTS......................................................................................................................................... 7 4.0 180-DAY REPORT CONTENTS................................................................................................... 7 4.1 a) The scope of inspections performed on each SG....................................................... 10 4.2 b) Active Degradation Mechanisms Found..................................................................... 13 4.3 c) Nondestructive examination techniques utilized for each degradation mechanism...................................................................................................................... 13 4.4 d) Location, orientation (if linear), and measured sizes (if available) of service induced indications.......................................................................................................... 17 4.5 e) Number of tubes plugged during the inspection outage for each degradation mechanism...................................................................................................................... 21 4.6 f) The number and percentage of tubes plugged to date................................................ 23 4.7 g) The results of condition monitoring, including the results of tube pulls and in-situ testing....................................................................................................................... 23 4.8 h) The effective plugging percentage for all plugging in each SG................................... 24 4.9 i) The results of monitoring for tube axial displacement (slippage)................................. 25
5.0 REFERENCES
............................................................................................................................ 26 APPENDIX A :
ACRONYMS AND ABBREVIATIONS..................................................................... A-1 APPENDIX B :
STEAM GENERATOR LAYOUT AND NOMENCLATURE..................................... B-1 APPENDIX C :
SUPPORT WEAR LISTING - SGA......................................................................... C-1 APPENDIX D:
SUPPORT WEAR LISTING - SGB......................................................................... 0-1 Page 4
ATTACHMENT 1 to AREVA-17-02174 fA Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report List of Tables Page Table 4-1: Refueling Outage (RFO) Information Since SG Replacement............................................... 9 Table 4-2: Eddy Current Tube Inspection Scope................................................................................... 10 Table 4-3: 1 R25 Active Degradation Mechanism.................................................................................. 13 Table 4-4: ECT Technique Table........................................................................................................... 14 Table 4-5: 1R25 Axial ODSCC Indications............................................................................................. 18 Table 4-6: 1 R25 Axial PWSCC Indication.............................................................................................. 19 Table 4-7: 1R25 Circumferential ODSCC Indications............................................................................ 19 Table 4-8: Historical Foreign Object Wear Indications (Volumetric) - No Object Present..................... 19 Table 4-9: Diagonal Bar Wear Summary............................................................................................... 19 Table 4-10: Vertical Strap Wear Summary............................................................................................ 20 Table 4-11: Eggcrate Wear Summary................................................................................................... 20 Table 4-12: Tubes Affected by Support Wear........................................................................................ 20 Table 4-13: 1 R25 Tube Plugging........................................................................................................... 21 Table 4-14: 1 R25 SG A Tubes Plugged................................................................................................ 22 Table 4-15: 1R25 SG B Tubes Plugged................................................................................................ 23 Table 4-16: Number and Percent of Tubes Plugged............................................................................. 23 Table 4-17: Tube 62-101 In Situ Pressure Test Summary.................................................................... 24 Table B-1: Palisades SG Tube Support Structure Nomenclature........................................................ B-2 Page 5
t ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report List of Figures Page Figure 4-1: 1R25 Inspection Summary.................................................................................................. 12 Figure 8-1: General Layout of Palisades SG Tube Support Structures............................................... 8-1 Figure 8-2: Palisades SG Tubesheet Map.......................................................................................... 8-2 Page 6
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report 1.0 PURPOSE The purpose of this document is to provide the 1R25 steam generator (SG) tube inspection report in accordance with Palisades Technical Specification 5.6.8, "Steam Generator Tube Inspection Reports" [3]. The report is provided in its entirety in Section 4.0 and the appendices of this document, from which it may be copied and modified as necessary by the Palisades Licensing Department.
2.0 ASSUMPTION This document contains no assumptions.
3.0 INPUTS The information summarized in this report was extracted from References [1], and [4].
4.0 180-0A Y REPORT CONTENTS Palisades Technical Specification (TS) 5.6.8, Steam Generator Tube Inspection Reports [3], requires Entergy Nuclear Operations, Inc. (ENO), to submit a report to the Nuclear Regulatory Commission (NRC) within 180 days after initial entry into mode 4 following a steam generator inspection performed in accordance with TS 5.5.8, Steam Generator (SG) Program. The report is required to address the following items:
- a.
The scope of inspections performed on each SG
- b. Active degradation mechanisms found
- c.
Nondestructive examination techniques utilized for each degradation mechanism
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications
- e.
Number of tubes plugged during the inspection outage for each degradation mechanism
- f.
The number and percentage of tubes plugged to date
- g. The results of condition monitoring, including the results of tube pulls and in-situ testing
- h. The effective plugging percentage for all plugging in each SG
- i.
The results of monitoring for tube axial displacement (slippage)
Entergy and AREV A performed a SG inspection in accordance with TS 5.5.8 during the Palisades Spring 2017 refueling outage (lR25). This inspection was the 17th in-service inspection following SG replacement and the lSI of 3 scheduled inspections in the fifth sequential Inspection period (Table 4-1). Initial entry into mode 4 occurred on May 15,2017; therefore, this report is required to be submitted by November 11,2017.
The following section ("Background") briefly describes the Palisades SG design characteristics and operating history, while the subsequent section ("Specific Responses") provides responses to each of the TS 5.6.8 questions.
Appendix A provides definitions for the acronyms and abbreviations used in this report.
Page 7
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report
Background
Palisades is a Combustion Engineering (CE) PWR equipped with two CE Model 2530 replacement steam generators. These steam generators were installed in the early 1990's as replacements for the original steam generators. Each steam generator contains 8219 Inconel 600 tubes with an outer diameter of 0.75 inches and nominal wall thickness of 0.042 inches. The tubes are arranged in a I-inch triangular-pitch pattern comprised of 138 rows and 165 columns. The tubes in rows 1 through 18 are of u-bend design with a minimum bend radius of 2.5 inches (row 1) and maximum radius of 11 inches (row 18). The tubes in Rows 19 through 138 are of "square-bend" design consisting of two 90 degree bends of constant radius with a straight horizontal section of tubing of varying length between the two bends. The tubes were explosively expanded throughout the full tubesheet depth and are supported by several structures which include horizontal eggcrate supports, diagonal bars, and vertical strap supports. All of the support structures were fabricated with stainless steel. The general layout of the steam generator internals and associated nomenclature are provided in Appendix B.
The Palisades SGs had accrued 21.15 effective full power years (EFPY) of operation through the end of cycle 25 (i.e., IR25) per Ref [6] with a nominal hot leg temperature of 583°P. The IR24 inspection of the two Palisades SGs was the 17th in-service inspection (lSI) following SG installation in 1990, and the first scheduled inspections in the fifth sequential inspection period (Table 1). The values provided in Ref [6] are the most current available from the utility and contain small Cycle EFPD differences (typically less than 1 EPPD) from the values used in the previous Palisades 180-Day report. Table 4.2 has been updated in entirety to match the values in Ref [6].
Page 8
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 1 BO-Day Steam Generator Tube Inspection Report Table 4-1: Refueling Outage (RFO) Information Since SG Replacement First Second Third Fourth Fifth Outage Cycle Cumulative Inspection Inspection Inspection Inspection Inspection Outage Period Period Period Period Period Year EFPD EFPY (EFPMs)
(EFPMs)
(EFPMs)
(EFPMs)
(EFPMs) 1R9 1992 298.5 0.82 9.81 1R10 1993 356.8 1.79 11.72 1R11 1995 430.4 2.97 25.86 1R12 1996 407.8 4.09 39.26 1R13 1998 424.2 5.25 53.2 1R14 1999 449.6 6.48 7.97 1R15 2001 402 7.58 21.18 1R16 2003 444.5 8.80 35.78 1R17 2004 493.1 10.15 51.98 1R18 2006 472 11.44 7.49 1R19 2007 459.2 12.70 22.57 1R20 2009 499.8 14.07 39.00 1R21 2010 507.7 15.46 55.68 1R22 2012 495.3 16.81 11.95 1R23 2014 513.3 18.22 28.81 1R24 2015 539.4 19.70 46.53 1R25 2017 533.1 21.15 4.05 1R16*
2018*
501
- 22.53*
20.51 Notes:
- Projection EFPD = effective full power days EFPM = effective full power months EFPY = effective full power years Page 9
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report 4.1 a) The scope of inspections performed on each SG The lR25 work scope in both SGs (SGA and SGB) included eddy current (BCT) inspections, primary side visual inspections, and secondary side visual inspections. Figure 4-1 details all ECT and plug visual inspections performed.
ECT Inspection A summary of the ECT inspections performed is provided in Table 4-2.
Table 4-2: Eddy Current Tube Inspection Scope Scope Probe Type SGA SGB Full Length (Note 1)
Bobbin 100%
100%
Row 1 through 3 U-bends MRPC 100%
100%
Hot Leg Tubesheets TTS+4"/-13.5" MRPC 100%
100%
Cold Leg Outer Three Periphery Tubes TTS+4"/-2" for detection of possible loose MRPC 12.8%
12.7%
parts or wear signals (Note 2)
Freespan Dings >5.0 Volts between TSH MRPC 100%
100%
andTSC Dents >2.0 Volts at Vertical Straps, Diagonal MRPC 100%
100%
Bars & Eggcrates between TSH and TSC Wear at Eggcrates (Current and Historical)
MRPC 100%
100%
Historical Wear at Diagonal Bars and MRPC 25%
25%
Vertical Straps Supplemental (Note 3)
MRPC 100%
100%
Notes:
- 1.
Except for the bend portion of rows 1 through 3
- 2.
The values shown are percentages of the installed tube population
- 3.
All DDI, DSI, NQI, PLP (Bound MRPC PLPs), PVN and new wear indications Page 10
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Primary Side Visual Inspections The primary side work activities include visual examination of the primary channel head and all installed tube plugs. The purpose of the as-found and as-left visual examination of the primary channel heads (both HIL and elL) is to assess general material condition, to identify and remove foreign objects, if any and to complete the cladding inspection in accordance with the AREV A procedure for bowl inspections to address Nuclear Safety Advisory Letter NSAL-12-1. Additional detail is available in Reference [1] No anomalous conditions were identified during these inspections. All plugs were present in the proper location and no degradation was observed.
Secondary Side Scope The secondary side work activities performed during the lR25 outage included a visual inspection and foreign object search and retrieval (FOSAR) at the top-of-tubesheet (TIS) in the tube-to-shell annulus and divider lane.
All visually-accessible passages between tubes were viewed from the tube bundle periphery on each leg. All findings were documented in the AREVA foreign object tracking system (FOTS).
Additional detail is available in Reference [1]
Page 11
A AREVA ATIACHMENT 1 to AREVA-17-02174 Document No.: 51-9275005-000 Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Figure 4-1: 1 R25 Inspection Summary S/G A
A A
A A
A A
A A
A A
B B
B B
B B
B B
B B
B B
Entergy Palisades Unll1 RF02S ECT Status Report Exams Exam Type Planned Bobbin - Full Length 7327 Bobbin - Hll Straights Rows 1-6 342 Bobbin - C/l Straights Rows 1-3 171 Bobbin - C/l Candycane Rows 4-6 171 RPC HIL TopotTubesheet 7669 RPC CIL Top of Tubesheet 988 RPC Row 1*3 U-Bend 171 RPC 51 HIL ONGIONTITRA 19 RPC SI CII.. ONGIONTITRA 62 RPC SI U-8end ONGIDNTITRA 1006 RPC 51 U-Bend 25% Wear Sample 203 Total Tests All Programs 18119 Bobbin - Full Length 7416 Bobbin - Hll Straights Rows 1-6 352 Bobbin - C/l Straights Rows 1-3 173 Bobbin - Cll Candycane Rows 4-6 179 RPC HII.. Top ofTubesheet 7768 RPC CII.. TOp of Tubesheet 989 RPC Row 1-3 U-Bend 173 RPC HIL Square Bend Bound 99-140 (07H-V52) 3 RPC 51 HII.. ONGIONTITRA 36 RPC SI CII.. ONGlDNTITRA 34 RPC 51 U-Bend ONGIDNTITRA 556 RPC SI U-Bend 25% Wear Sample 205 Total Tests All Programs 17884 5/8117 12:25 PM Exams Total Acquired Retests 7327 0
342 0
171 0
171 0
7669 0
988 0
171 0
19 0
62 0
1006 0
203 0
18119 0
7416 0
352 0
173 0
179 0
7768 0
989 0
173 0
3 0
36 0
34 0
556 0
205 0
17884 0
Sellcla! Interest.eolnt Dlasl!ostls; !i;xams Exams Exams Planned Acquired A
RPC HII.. I-Codes/T5P % TW/New ONT-ONG 406 406 A
RPC ell l-CodeslTSP %TWlNew ONT-ONG 550 550 A
RPC U-Bend I-CodesINew ONT ONG.%TW 69 69 Total Tests All 51 Programs 1025 1025 B
RPC HII..I-COdesIT5P %TWlNew ONT-ONG 345 345 B
RPC CIll-CodesITSP %TW/New ONT-ONG 560 560 B
RPC u-Send I-CodesINew ONT DNG %TW 46 46 Total Tests All SI Programs 951 951 ADDITIONAL INFORMATION Plugs Plugs Planned Inspected A
HIL Plugs Visual Exam 550 550 A
Cll PlUgs Visual Exam 550 550 8
HIL PlUgs Visual Exam 451 451 B
CIL Plugs Visual Exam 451 451 Repair Candidates S/GA
§&!.
Bobbin >= 40%
1 0
+Point I-Codes 14 3
Preventative Tube PluQ 10 Total New Tubes to Plug 25 3
Prior Plu!j!jed Tubes 550 451 Total Committed Plugged Tubes 575 454 A
AREVA Exams II %
Evaillated complete 7327 10000%
342 100.00%
171 100.00%
171 100.00%
7669 100.00%
988 100.00%
171 10000%
19 10000%
52 100.00%
1006 100.00%
203 100.00%
18119 100.00%
7416 100.00%
352 100.00%
173 100.00%
179 10000%
7768 10000%
989 100.00%
173 10000%
3 100.00%
36 100,00%
34 100.00%
556 100.00%
205 100.00%
17884 10000%
Exams Evaluated Complete 406
' Too.oo%
550 100.00%
69 100.00%
1025
.. JOO.OO%
345
- ' 0000%
560 10000%
46 100.00%
951 100.00%
Complete 100.00%
100.00%
100.00%
10000%
Total 28 1001 1029 Page 12
ATIACHMENT 1 to AREVA-17-02174 t\\
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report 4.2 b) Active Degradation Mechanisms Found Degradation identified in lR25 included corrosion-related cracking coincident with structures and in the freespan, and mechanical wear. Degradation identified was predicted and addressed in the Degradation Assessment. Table 4-3summarizes the degradation identified.
Table 4-3: 1 R25 Active Degradation Mechanism SG Location Damage Mechanism Both Diagonal Bar (DB) Support Wear Both Vertical Strap (VS) Support Wear Both Eggcrate (EC) Support Wear Both Foreign Object (FO) on TTS (Note 1)
Wear Both Hot Leg EC Supports Axial ODSCC Both Hot Leg Top-of-Tubesheet (TTS)
Axial ODSCC SGB Hot Leg Freespan (no ding)
Axial ODSCC / IGA (Note 2)
SGA Hot Leg Top-of-Tubesheet (TTS)
Circumferential ODSCC SGA Hot Leg Tubesheet Expansion Axial PWSCC Notes:
- 1. All Foreign Object Wear identified in 1R25 was historical with the object having been removed in a prior inspection. There was no new foreign object wear or wear adjacen to a foreign object identified in 1 R25.
- 2. 8 indications of Axial ODSCC were identified in SGB at 1R25 in tube 62-101. The indications had flaw morphology characteristics of Freespan Axial lntergranular Attack (lGA). Both Axial ODSCC and Axiai lGA are detected and sized using the same ECT probes/techniques. Other indications were evaluated for characteristics of IGA. None was identified.
4.3 c) Nondestructive examination techniques utilized for each degradation mechanism Nondestructive examination utilized during the lR25 inspection and their corresponding intended degradation mechanism are given in Table 4-4..
Page 13
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1R25 2017180-Day Steam Generator Tube Inspection Report Table 4-4: ECT Technique Table Degradation Probe EPRI Demonstrated Applicability Extended Detection?
Sizing?
Mechanism Type ETSS Applicability BOBBIN PROBE Tube to Tube Bobbin 13091.1 Freespan tube-to-tube wear None Yes Yes Wear Rev. 0 128413 Freespan (excluding u-bend),
AxialODSCC Bobbin Rev. 3 eggcrate, sludge pile, & broached None Yes No TSPs with or without dents S2Vpp AxialODSCC Bobbin 24013.1 Freespan including dings S5V None Yes No Rev. 2 Foreign Bobbin 27091.2 Foreign object wear Extended for Yes Yes Object Wear Rev. 1 (part not present); 1-690 tubing 1-600 tubing Support Wear Bobbin 96004.1 AVBs, TSPs, Dents <5V Yes Yes I
Rev. 13 vertical and diagonal straps Pitting Bobbin 96005.2 Freespan in the Sludge Pile Yes Yes Rev. 9 presence of copper AXIALODSCC 128424 Rev. 3 Depth: Yes (detect);
TSP (with or without dents AxialODSCC
+Point'M None Yes BED: Yes 128431
<=2vpp) and sludge pile Rev. 2 BEL: Yes (sizing) 128425 Rev. 3 Depth: Yes (detect)
Freespan (excluding u-bend),
AxialODSCC
+Point' eggcrate, & broached TSPs with or None Yes BED: Yes 128432 without dents S2Vpp Rev.2 BEL: Yes (sizing)
AxialODSCC
+Point' 10411.1 Low Row U-bends Higher Row Yes Yes Rev. 0 U-bends 21409.1 Support structures, freespan, PDA: Info AxialODSCC
+Point' U-bends Yes Rev. 7 sludge pile, & tubesheet crevice Length: Info Freespan dings &
Depth: Info AxialODSCC
+Point' 22401.1 Dented TSPs dented eggcrates, Yes Rev. 4 diagonal bars and Length: Yes vertical straps AXIALPWSCC Depth: Yes Axial PWSCC
+Point'M 20511.1 Expansion Transitions Tubesheet Yes PDA: Info Rev. 8 Length: Yes Page 14
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1R25 2017 180-Day Steam Generator Tube Inspection Report Degradation Probe EPRI Demonstrated Applicability Extended Detection?
Sizing?
Mechanism Type ETSS AJmlicabilitv 96703.1 Tubesheet, Depth: Yes Axial PWSCC
+Point' Rev. 17 Dents/Dings Dented supports Yes Length: Yes Axial PWSCC
+Point' 96511.2 Low Row U-bends Higher Row Yes Yes Rev. 16 U-bends
+Point' 99997.2 Higher Row I
Axial PWSCC High FreQ Rev. 10 Low Row U-bends U-bends Yes Yes I
CIRCUMFERENTIAL ODSCC 21410.1 U-bends, Depth: Info CircODSCC
+Point' Rev. 6 Expansion Transitions frees pan dings, Yes Note 4 dented supports PDA: Yes CircODSCC
+Point' 22842.1 Dented Supports Freespan dings, Yes Length: Yes Rev. 4 u-bends CIRCUMFERENTIAL PWSCC 111524 U-bends, CircPWSCC
+Point'M Rev. 0 Expansion Transitions Dents/Dings, Yes No Tubesheet Depth: Yes CircPWSCC
+Point' 20510.1 Expansion Transitions U-bends No (see PDA: Yes Rev. 7 111524)
LenQth: Yes CircPWSCC
+Point' 96511.2 See II Axial PWSCC" section of this table Rev. 16 Depth: Yes CircPWSCC
+Point' 96701.1 Expansion Transitions Dents/Dings and No (see PDA: Yes Rev. 12 tubesheet 111524)
Length: Yes CircPWSCC
+Point'M 99997.2 See "Axial PWSCC" section of this table High FreQ Rev. 10 WEAR Tube to Tube
+Point' 13901.1 Freespan tube-to-tube wear U-bends Yes Depth: Yes Wear Rev. 1 Dented/non-10908.4 dented Supports, Wear
+Point'M Rev. 1 AVBs Foreign object Yes Depth: Yes wear (part present)
Foreign
+Point' 27901 Foreign object wear Volumetric Object Wear or.115 through Freespan Wear Yes Yes (Note 1)
Pancake 27907 (part not present)
(part not present)
PITTING Pitting I +p. tTM I 21998.1 I oln Rev. 4 Volumetric i~ frees pan __ L Sludge Pile Yes Yes Page 15
A AREVA ATTACHMENT 1 to AREVA-17-02174 Document No.: 51-9275005-000 Degradation Mechanism Palisades 1R25 2017180-Day Steam Generator Tube Inspection Report Probe EPRI-1 Type ET$S J
Extended A~Rlicability_ _
Detection?
Demonstrated Applicability Sizing?
NOTES:
- 1.
Multiple ETSSs were available for depth sizing of foreign object wear, each depending on the shape of the wear scar and the coil being used.
Page 16
J ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 1 BO-Day Steam Generator Tube Inspection Report 4.4 d) Location, orientation (if linear), and measured sizes (if available) of service induced indications The location, orientation, and measured size of axial oosee, circumferential oosee, and foreign object wear indications identified during the 1R25 outage are provided in Table 4-5, Table 4-6, Table 4-7, and Table 4-8. Oue to the large number support wear indications, the required data is provided in Appendix e and Appendix o.
Statistical summaries of through wall depth, growth rates of support wear populations (Le., diagonal bar, vertical strap, and eggcrate wear), and the number of tubes affected by support wear are provided in Table 4-9, Table 4-10, Table 4-11, and Table 4-12. In these tables, "New" refers to support wear indications that were newly reported during the 1R25 outage, and "Repeat" refers to support wear indications reported during previous outage inspection(s) and again measured during 1R25.
Axial outside diameter stress corrosion cracking (OOseC) trends were evaluated over the last four inspections.
The maximum detected depth was bounded by predictions of the previous Operational Assessment. The max depth and average depths continued to follow the same trend of the previous two inspections. This is not unexpected and addressed in the multi-cycle probabilistic model used in section 9.2 of
[1]. The population is significantly less than that identified in IR22. A comparison of 1R23, lR24 and 1R25 eddy current results revealed no transients in signal amplitudes which would suggest a degradation of data quality, and innocuous indications which were not removed from service produced similar responses from outage to outage. In addition, measurements of signal noise in regions of interest within the SGs confirm that data quality has not deteriorated with time as discussed in detail in section 9.1 of [1].
Page 17
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube I nspection Report Table 4-5: 1 R25 Axial OOSCC Indications
+Point300 Structural Structural kHz NDEMaximum NDEAxial Ro Amplitude Depth (%TW)
Length Length Depth (%TW)
SG w
Col.
Location (Vpp)
(Note 1)
(in.)
(in.)
(Note 1)
A 37 50 TSH+0.42
.47 54.4 0.18 A
44 115 TSH+0.31
.52 56.1 0.24 0.2 48.6 A
44 115 TSH+O.44
.71 61.2 0.29 0.22 54.6 A
69 98 TSH+0.58
.39 51.3 0.24 A
74 97 TSH+0.67
.92 65.5 0.18 0.11 57.2 A
77 80 TSH+0.42
.69 60.8 0.24 0.18 48.2 A
77 80 TSH+0.56
.65 59.8 0.27 0.18 48.2 A
80 97 TSH+0.41
.64 59.5 0.21 0.16 52.1 A
81 90 TSH+0.53
.52 56.1 0.22 A
81 98 TSH+0.39
.61 58.7 0.23 0.18 51.8 A
83 92 TSH+0.32
.76 62.4 0.23 0.16 55 A
102 101 TSH-0.09
.68 60.5 0.14 B
43 114 TSH+0.49
.63 59.3 0.24 0.22 49.8 B
43 114 TSH+0.76
.39 51.3 0.33 0.29 48.8 B
78 91 TSH+0.82
.65 59.8 0.22 0.2 46.1 04H-14.56
.26 39.8 0.6 0.42 33.6 B
62 101 1.09 (Note 2) 04H-13.58 69.8 1.31 0.65 63.5 04H-l1.53
.39 48.3 1.16 0.42 44.4 04H-1O.36
.22 36.3 0.37 0.2 31.4 04H-7.58
.19 33.3 0.42 0.22 27.1 04H-5.73
.15 28.3 0.34 0.29 20.5 04H-4.16
.22 36.3 0.98 0.55 28 04H-2.62
.28 41.4 1.36 0.33 35 Notes:
- 1.
The NDE maximum depth values were calculated using the Appendix I regression techniques (%TW as function ofNDE Voltage) and then reduced by 11 %TW in accordance with References [1] and [2].
- 2.
The eight indications in SGB 62-101 were all reported as Freespan axial ODSCC; however, the flaw morphology is also characteristic of Freespan Axial IGA. Both Axial ODSCC and Axial IGA are detected and sized using the same ECT probes/techniques. Other indications were evaluated for characteristics of IGA. None was identified.
Page 18
t ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Table 4-6: 1 R25 Axial PWSCC Indication
+Point 300 kHz NDEAxial NDE Structural Structural Maximum SG Row Col.
Location Amplitude Length Depth Length Depth (Vpp)
(in.)
(%TW)
(in.)
(%TW)
A 18 109 TSH-0.40 1.66 0.45 100 0.40 97.3 Table 4-7: 1 R25 Circumferential ODSCC Indications
+Point 300 NDE Percent kHz Degraded Location Area Amplitude (PDA)
Circumferential SG Row Col (Vpp)
(Note 1)
Length (in.)
A 100 105 TSH-0.02 0.50 1.6 0.22 A
106 101 TSH-0.07 0.60 6.1 0.47 A
111 100 TSH-0.02 0.97 9.7 0.36 Notes
- 1.
The percent degraded area (PDA) of the circumferential indications was determined using the EPRI Draw Program based on measurements from EPRI ETSS H-2141O.1.
Table 4-8: Historical Foreign Object Wear Indications (Volumetric) - No Object Present Maximum Circumferential Axial SG Row Col.
Location Sizing ETSS Depth (%TW)
Extent (0)
Extent (in.)
A 130 63 TSH + 1.45 21998.1 20 38 0.25 B
137 92 TSH+ 10.71 21998.1 22 38 0.27 B
137 92 TSH + 11.87 21998.1 22 38 0.27 Table 4-9: Diagonal Bar Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications
(%TW)
(%TW/EFPy)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
2 122 14.9 25.9 38.0 0.3 3.4 4.8 B
2 96 16.8 29.0 32.0
-0.3 2.9 5.5 Both 4
218 15.8 29.0 38.0 0.0 3.4 5.5 SGs Page 19
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Table 4-10: Vertical Strap Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications
(%TW)
(%TW/EFPy)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
5 632 17.4 31.2 46.0 0.1 2.7 6.2 B
8 660 19.9 33.0 39.0 0.2 3.4 5.5 Both 13 1292 18.7 32.0 46.0 0.1 2.7 6.2 SGs Table 4-11: Eggcrate Wear Summary Number of New and Repeat Depths Growth Rate of Repeats Indications
(%TW)
(%TW/EFPV)
SG New Repeat Average Upper 95th Maximum Average Upper 95th Maximum A
38 852 15.2 23.0 36.0 0.2 2.7 4.8 B
14 824 15.9 23.0 37.0 0.1 2.7 4.8 Both 52 1676 15.5 23.0 37.0 0.2 2.7 4.8 SGs Table 4-12: Tubes Affected by Support Wear SG Diagonal Bar Wear Vertical Strap Wear Eggcrate Wear A
124 637 890 B
98 668 838 Page 20
ATTACHMENT 1 to AREVA-17-D2174 fA Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report 4.5 e) Number of tubes plugged during the inspection outage for each degradation mechanism Twenty-eight tubes were plugged during lR25. Counts and degradation mechanisms are given in Table 4-13 below.
Note that Table 4-13 counts the number of tubes plugged per degradation mechanism. Tables 4-14 and 4-15 list every flaw that exceeded plugging criteria. Because some tubes contained more than one pluggable indication, the number of flaws on tables 4-14 and 4-15 is larger than the number of tubes plugged in table 4-13.
Table 4-13: 1 R25 Tube Plugging SGA SGB Total Location Tubes Tubes Tubes Tubes Tubes Tubes Plugged Stabilized Plugged Stabilized Plugged Stabilized OD Axial at Support 0
0 0
0 0
0 OD Axial at TSH Transition / Sludge Pile 10 0
2 0
12 0
OD Axial in Freespan / IGA (Note 1) 0 0
1 0
1 0
OD eire in TSH Expansion Transition 3
3 0
0 3
3 ID Axial in TSH Expansion 1
0 0
0 I
0 Foreign Object Proximity (Note 2) 10 8
0 0
10 8
Foreign Object Wear 0
0 0
0 0
0 Wear at Supports 1
0 0
0 1
0 Total 25 11 3
0 28 11 Notes:
- 1. Tube 62-101 in SGB was plugged for indications that were identified as freespan Axial ODSCC but also had flaw morphology characteristics of Freespan Axial IGA. Other indications were evaluated for characteristics of IGA. None was identified.
- 2. Tubes 137-74,53-152, 52-153,54-153, 33-160,34-159, 35-160,34-161, 36-161,35-162 in SGA were preventatively plugged per request of Entergy to bound a foreign object (FO) (Entergy Letter SG-2017-001, -002 and -003) All these tubes EXCEPT 33-160 and 34-159 were plugged and stabilized due to proximity to unretrieved foreign objects. Tubes33-160 and 34-159 tubes were farther from the objects and plugged only and not stabilized as a preventative measure in case a FO migrated.
Page 21
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Table 4-14: 1R25 SG A Tubes Plugged Count S/G Row Col Hot Leg Cold Leg Reason for Tube Repair 1
A 37 50 Rolled Plug Rolled Plug SAl @ TSH+O.38 2
A 137 74 Rolled Plug + Stabilizer Rolled Plug PTP Foreign Object TSH Rolled Plug SAl @ TSH+0.49 3
A 77 80 Rolled Plug SAl @ TSH+0.36 4
A 81 90 Rolled Plug Rolled Plug SAl @ TSH+0.50 5
A 83 92 Rolled Plug Rolled Plug SAl @ TSH+0.30 6
A 134 95 Rolled Plug Rolled Plug TWD @ VS7+O.69 7
A 74 97 Rolled Plug Rolled Plug SAl @ TSH+0.60 8
A 80 97 Rolled Plug Rolled Plug SAl @ TSH+0.36 9
A 69 98 Rolled Plug Rolled Plug SAl @ TSH+O.58 10 A
81 98 Rolled Plug Rolled Plug SAl @ TSH+O.29 11 A
111 100 Rolled Plug + Stabilizer Rolled Plug SCI @ TSH-0.09 12 A
102 101 Rolled Plug Rolled Plug SAl @ TSH-O.l6 13 A
106 101 Rolled Plug + Stabilizer Rolled Plug SCI @ TSH-0.02 14 A
100 105 Rolled Plug + Stabilizer Rolled Plug SCI @ TSH-O.OO 15 A
18 109 Rolled Plug Rolled Plug SAl @ TSH-O.51 SAl @ TSH+0.29 16 A
44 115 Rolled Plug Rolled Plug SAl @ TSH+0.42 17 A
53 152 Rolled Plug Rolled Plug + Stabilizer PTP Foreign Object TSC 18 A
52 153 Rolled Plug Rolled Plug + Stabilizer PTP Foreign Object TSC 19 A
54 153 Rolled Plug Rolled Plug + Stabilizer PTP Foreign Object TSC 20 A
33 160 Rolled Plug Rolled Plug PTP Foreign Object TSH 21 A
34 159 Rolled Plug Rolled Plug PTP Foreign Object TSH 22 A
35 160 Rolled Plug + Stabilizer Rolled Plug PTP Foreign Object TSH 23 A
34 161 Rolled Plug + Stabilizer Rolled Plug PTP Foreign Object TSH 24 A
36 161 Rolled Plug + Stabilizer Rolled Plug PTP Foreign Object TSH 25 A
35 162 Rolled Plug + Stabilizer Rolled Plug PTP Foreign Object TSH Page 22
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Table 4-15: 1R25 SG B Tubes Plugged Count S/G Row Col HotLe2 ColdLe2 Reason for Tube Repair I
B 43 114 Rolled Plug Rolled Plug SAl @ TSH+O.47 SAl @ TSH+0.76 SAl @ 04H-14.53 SAl @ 04H-13.58 SAl @ 04H-l1.60 SAl @ 04H-IO.31 2
B 62 101 Rolled Plug Rolled Plug SAl @ 04H-7.60 SAl @ 04H-5.73 SAl @ 04H-4.16 SAl @ 04H-3.24 SAl @ 04H-2.62 3
B 78 91 Rolled Plug Rolled Plug SAl @ TSH+0.76 4.6 f) The number and percentage of tubes plugged to date The number of tubes plugged prior to lR25, the number of tubes plugged in lR25 and the current total of tubes plugged, along with the corresponding percentages is given below in Table 4-16.
Table 4-16: Number and Percent of Tubes Plugged SGA SGB Total Total Tubes Installed 8219 8219 16438 Tubes Plugged Pre-Service 308 309 617 Tubes Plugged During Service through IR24 242 142 384 Tubes Plugged in lR25 25 3
28 Total Tubes Plugged to Date 575 454 1029 Effective Tubes Plugged to Date 575 454 1029 Effective Plugging Percentage 7.0 5.5 6.3 4.7 g) The results of condition monitoring, including the results of tube pulls and in-situ testing Through a combination of eddy current inspection, analytical evaluation, in-situ pressure testing, and operational leakage monitoring, it has been determined that the three performance criteria (Le., structural integrity, accident induced leakage integrity, and operational leakage integrity) were satisfied during the operating period prior to the lR25 outage. With two exceptions, all tubes satisfied performance criteria analytically.
Page 23
ATTACHMENT 1 to AREVA-17-02174 t\\
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report
- 1. In SG A, tube 62-101 failed to analytically satisfy performance criteria for structural integrity. That tube was subject to in-situ pressure testing on the most limiting flaw which demonstrated that the tube in fact satisfied the structural and accident-induced leakage performance criteria. Additionally, the flaws in this tube were all identified as Axial Freespan ODSCC but had flaw morphology characteristics of Freespan Axial Intergranular Attack (IGA). Both Axial ODSCC and Axial IGA are detected and sized using the same ECT probes/techniques and therefore the analytical CM results are unaffected. Test pressures, hold times, average pressurization rate and measured leakage (all leakage was zero) are given below in Table 4-17 per reference [5]. Other indications were evaluated for characteristics of IGA. None was identified.
Table 4-17: Tube 62-101 In Situ Pressure Test Summary Tube/Defect!
Pressure Hold Maximum Average Location Hold Time Leak Rate Pressurization Points (psi)
(min)
(gpm)
Rate (psi/sec) 1600 2
0 12 3000 2
0 23 62-101 3550 2
0 18 03H - 04H 4000 2
0 19 4600 2
0 30
- 2. In SGA, tube 18-109 had one indication of axial PWSCC that had a measured depth of up to 100%TW.
The flaw was fully contained within the tubesheet expansion precluding the potential for tube rupture; therefore, the indication 'satisfied structural integrity performance criterion through the operating period preceding IR25 and in-situ pressure testing was not required per EPRI Guidelines for flaws fully contained in the tubesheet.
No tube pulls were planned and none were performed.
The condition monitoring assessment concluded that the structural integrity criteria (TS 5.5.8b.l) and accident induced leakage performance criteria (TS 5.5.8b.2) were satisfied during the operating interval preceding IR25.
Operational leakage monitoring during cycle 25 indicated stable, low level primary to secondary leakage. The indicated leakage was just above detectability with a maximum of 0.547 GPD during the cycle based on Xe-135 activity [4]. Consequently, the plant specific operational leakage performance criterion (150 GPD, TS 5.5.8b.3, LCO 3.4. 13d) was also satisfied throughout the cycle.
4.8 h) The effective plugging percentage for all plugging in each SG Since no sleeving has been performed in the Palisades steam generators, the effective plugging percentage is the same as the actual plugging percentage (see Section 4.6).
Page 24
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report 4.9 i) The results of monitoring for tube axial displacement (slippage)
Potential tube axial displacement in the tubesheet (slippage or "pullout") was monitored. Algorithms were implemented in the ECT data analysis software to detect this condition. None was identified.
Page 25
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report
5.0 REFERENCES
- 1.
AREV A Document 51-9273700-000 "Palisades Steam Generator Condition Monitoring for 1 R25 and Final Operational Assessment for Cycle 26"
- 2.
PNP 2012-021, April 5, 2012
- 3. *Palisades Technical Specification (Administrative Controls), 5.5.8, "Steam Generator (SG) Program" (Includes Amendment No 225 and 261 to Renewed Facility Operating License No. DPR-20)
- 4. AREV A Document 51-9267304-000, "Steam Generator Degradation Assessment for Palisades IR25 Inspection, Spring 2017"
- 5. AREVA Document 51-9271424-000 "Palisades In-Situ Pressure Test Summary Report (May 2017)"
- 6. AREV A Document 38-9276079-000 "Palisades Updated EFPY August 2017" References identified with an (*) are maintained within the Palisades Records System and are not retrievable from AREVA Records Management. These are acceptable references per AREVA Administrative Procedure 0402-01,. See page [2] for Project Manager Approval of customer references.
Page 26
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 1 BO-Day Steam Generator Tube Inspection Report APPENDIX A:
ACRONYMS AND ABBREVIATIONS Acronym Definition O"x"H or O"x"C Hot (H) or Cold (C) Leg Support Plate #X AVB Anti-Vibration Bar BED Burst Equivalent Depth BEL Burst Equivalent Length CMOA Condition Monitoring and Operational Assessment DDI Dent or Ding with Indication DSI Distorted Support Indication ETSS Examination Technique Specification Sheet FDMS AR'2VA Data Management System IGA Intergranular Attack LP Loose Part MRPC Motorized Rotating Pancake Coil (+pt.1M)
MBM Manufacturing Bumish Mark NDD No Degradation Detected NDE Non Destructive Examination NQI Non-Quantifiable Indication NTE No Tube Expansion ODSCC Outside Diameter Stress Corrosion Cracking PDA Percent Degraded Area PLG Tube Is Plugged PLP Possible Loose Part PTE Partial Tube Expansion PTP Preventative Tube Plug PVN Permeability Variation PWR Pressurized Water Reactor PWSCC Primary Water Stress Corrosion Cracking SAl Single Axial Indication SCI Single Circumferential Indication SGA Steam Generator E-50A SGB Steam Generator E-50B SVI Single Volumetric Indication TBP To Be Plugged TSP Tube Support Plate TTS Top ofTubesheet TSC Tubesheet Cold (Leg)
TSH Tubesheet Hot (Leg)
TWO Through Wall Degradation
%TW Percent throughwall
<TS Less Than Technical Specification Plugging Limit VS"X:'
Vertical Strap #X WAR Wear Indication PageA-1
A AREVA ATTACHMENT 1 to AREVA-17-02174 Document No.: 51-9275005-000 Palisades 1 R25 2017 180-Day Steam Generator Tube I nspection Report APPENDIX B:
STEAM GENERATOR LAYOUT AND NOMENCLATURE Figure B-1: General Layout of Palisades SG Tube Support Structures OBH DBC OSH 0SC 07H 07C 06H 0SC 05H 05C 04H 04C 03H 03C O2H
- 02C OlH
".. 0le TSH n" TSC TEH TEe
~
Page 8-1
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R2S 2017 1 BO-Day Steam Generator Tube Inspection Report Figure 8-2: Palisades SG Tubesheet Map 160 ISO 140 130 120 110 60 30 20 10 Table 8-1: Palisades SG Tube Support Structure Nomenclature Name Description Name Description TEH Tube End - Hot Side VS4 Fourth Vertical Strap TSH Top of Tubesheet - Hot Side VSS Fifth Vertical Strap 01 H First Eggcrate - Hot Side VS6 Sixth Vertical Strap 02H Second Eggcrate - Hot Side VS7 Seventh Vertical Strap 03H Third Eggcrate - Hot Side DBC Diagonal Strap - Cold Side 04H Fourth Eggcrate - Hot Side OBC Eighth Eggcrate - Cold Side OSH Fifth Eggcrate - Hot Side 07C Seventh Eggcrate - Cold Side 06H Sixth Eggcrate - Hot Side 06C Sixth Eggcrate - Cold Side 07H Seventh Eggcrate - Hot Side OSC Fifth Eggcrate - Cold Side OBH Eighth Eggcrate - Hot Side 04C Fourth Eggcrate - Cold Side DBH Diagonal Strap - Hot Side 03C Third Eggcrate - Cold Side VS1 First Vertical Strap 02C Second Eggcrate - Cold Side VS2 Second Vertical Strap 01C First Eggcrate - Cold Side VS3 Third Vertical Strap TSC Top of Tubesheet - Cold Side TEC Tube End - Cold Side Page B-2
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report APPENDIX C:
SUPPORT WEAR LISTING - SGA Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1
A 134 95 VS7 0.69 46 38 A
134 95 VS6 0.89 32 2
A 75 44 VS3
-0.8 39 39 A
136 79 07C
-0.27 32 3
A 93 130 VS4 0.95 39 40 A
138 81 DBH 2.05 32 4
A 135 78 VS6 0.64 39 41 A
109 34 VS4 0.64 31 5
A 48 19 VS4
-1.19 38 42 A
137 92 05C 0
31 6
A 93 104 VS4
-0.42 38 43 A
138 75 DBH 1.97 31 7
A 106 59 VS4 1.05 38 44 A
138 81 VS6 0.94 31 8
A 110 131 DBH
-1.84 38 45 A
40 147 VS4
-0.84 30 9
A 115 90 VS4
-0.71 38 46 A
43 126 VS4 1
30 10 A
135 100 VS7
-0.4 37 47 A
44 21 VS4
-0.84 30 11 A
137 92 VS6
-0.82 37 48 A
47 122 VS4 0.99 30 12 A
138 81 VS6
-0.86 37 49 A
48 19 VS4 0.64 30 13 A
46 65 VS4 0.93 36 50 A
48 97 VS4 0.83 30 14 A
48 41 VS4
-1.04 36 51 A
69 22 VS4 0.94 30 15 A
95 30 VS4
-0.78 36 52 A
76 15 DBC
-1.63 30 16 A
117 42 OlC
-1.03 36 53 A
81 84 VS4 0.93 30 17 A
48 43 VS4
-1.02 35 54 A
95 30 VS4 0.95 30 18 A
48 69 VS4 0.93 35 55 A
116 39 02C
-0.93 30 19 A
118 43 01C
-0.97 35 56 A
126 103 VS4
-0.95 30 20 A
42 41 VS4
-1 34 57 A
127 112 03C
-0.86 30 21 A
68 139 VS5 0.86 34 58 A
129 58 02H 0.97 30 22 A
96 25 VS4 0.74 34 59 A
135 94 DBC
-1.89 30 23 A
106 31 VS6
-0.88 34 60 A
135 94 VS7
-0.54 30 24 A
107 32 VS4
-0.62 34 61 A
137 80 VS7 0.78 30 25 A
126 69 VS4 0.87 34 62 A
46 53 VS4
-0.89 29 26 A
77 16 VS4
-0.8 33 63 A
49 20 VS4
-0.82 29 27 A
100 137 03C
-0.49 33 64 A
68 139 VS3
-0.75 29 28 A
112 59 VS6 1.1 33 65 A
84 61 03C 0.82 29 29 A
134 91 DBC 1.91 33 66 A
89 108 06H 0.97 29 30 A
43 46 VS4
-0.69 32 67 A
91 22 VS4 0.44 29 31 A
50 157 VS3
-0.9 32 68 A
93 104 VS6 1.06 29 32 A
88 145 02C 0.04 32 69 A
94 77 VS2 1.09 29 33 A
97 50 VS2
-0.86 32 70 A
97 120 VS2 1.06 29 34 A
97 52 VS4
-0.6 32 71 A
100 67 VS6
-0.72 29 35 A
128 71 VS1 0.86 32 72 A
106 31 VS6 0.89 29 36 A
132 95 VS7 0.85 32 73 A
108 33 VS4
-0.88 29 37 A
134 95 VS2 0
32 74 A
109 98 VS2
-0.85 29 Page C-1
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 75 A
110 123 08H
-0.91 29 115 A
85 20 VS4
-0.85 26 76 A
132 93 VS2 0.58 29 116 A
95 24 VS4
-1.18 26 77 A
137 92 VS6
-0.15 29 117 A
99 140 VS4
-0.72 26 78 A
42 41 VS4 0.88 28 118 A
105 30 VS4
-0.48 26 79 A
44 21 VS4 0.71 28 119 A
106 59 VS4
-0.96 26 80 A
44 49 VS4
-0.79 28 120 A
122 81 VS4 0.93 26 81 A
44 49 VS4
-0.02 28 121 A
135 78 08C
-1.11 26 82 A
51 20 VS3
-0.78 28 122 A
41 60 05H 0.99 25 83 A
97 52 VS6 0.81 28 123 A
65 138 04C
-0.11 25 84 A
113 130 VS4
-0.43 28 124 A
69 152 VS3 1.1 25 85 A
118 41 02C 0
28 125 A
95 124 VS2 1.03 25 86 A
121 118 VS4
-0.71 28 126 A
97 116 05C 0.36 25 87 A
134 69 VS7 0.83 28 127 A
100 119 VS2 0.22 25 88 A
134 95 VS4
-0.83 28 128 A
102 121 VS4
-0.82 25 89 A
135 72 VS1
-0.78 28 129 A
103 122 DBC 1.6 25 90 A
137 76 VS4
-0.65 28 130 A
104 135 03C 0.73 25 91 A
38 51 04C 0.82 27 131 A
107 134 02C
-0.97 25 92 A
41 52 VS4
-0.73 27 132 A
108 35 01C 0.02 25 93 A
48 21 VS4
-0.84 27 133 A
113 130 VS4
-0.77 25 94 A
64 11 VS4
-0.93 27 134 A
114 129 VS4
-0.96 25 95 A
67 14 05H 0.86 27 135 A
115 92 VS1 0.96 25 96 A
69 22 VS4
-1.02 27 136 A
117 40 02C 0.82 25 97 A
69 22 VS5 0.91 27 137 A
137 76 VS4 0
25 98 A
85 146 03C
-1.05 27 138 A
28 31 VS4
-0.96 24 99 A
108 33 VS4 1.01 27 139 A
46 53 VS4 1.03 24 100 A
121 118 03C 0.82 27 140 A
47 126 VS4
-0.02 24 101 A
129 54 02C
-1 27 141 A
49 20 VS4 1.09 24 102 A
134 91 VS7
-0.8 27 142 A
67 24 06H 0.87 24 103 A
136 91 08C 0.71 27 143 A
77 44 VS5 0.9 24 104 A
137 92 08C 0.72 27 144 A
95 134 04C
-0.98 24 105 A
138 85 VS7 0.99 27 145 A
95 136 VS2 0.98 24 106 A
38 35 04H 0.89 26 146 A
97 106 VS4
-0.82 24 107 A
47 122 VS4 0.12 26 147 A
98 65 VS2
-0.58 24 108 A
47 126 VS4
-0.81 26 148 A
106 133 DBC 1.43 24 109 A
54 83 DBH 0.06 26 149 A
116 105 VS4
-0.92 24 110 A
67 114 02C 0.84 26 150 A
116 121 04C 0.82 24 111 A
69 152 VS3
-0.82 26 151 A
119 52 06C 0.78 24 112 A
75 16 VS5
-1.03 26 152 A
130 99 03C
-0.13 24 113 A
77 148 03C 0.75 26 153 A
133 94 VS6
-0.88 24 114 A
79 128 04C 0.8 26 154 A
135 94 VS6 0.94 24 Page C-2
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 155 A
137 74 VS1 0.15 24 195 A
49 74 VS4
-0.82 22 156 A
138 83 DBH 2.09 24 196 A
52 117 02C 0.8 22 157 A
14 3
02C 0.81 23 197 A
53 122 02C
-0.22 22 158 A
19 64 DBC
-1.69 23 198 A
63 82 03H 0.93 22 159 A
38 35 03H 0.94 23 199 A
65 12 06H 0.92 22 160 A
45 124 VS4 0.79 23 200 A
70 53 03C 0.09 22 161 A
46 55 VS4 0.98 23 201 A
70 153 VS3
-0.98 22 162 A
48 7
01C 0.79 23 202 A
76 55 03C 0.85 22 163 A
65 152 VS3 1.19 23 203 A
76 101 02H
-0.73 22 164 A
69 86 06C 0.76 23 204 A
79 144 VS5 1.01 22 165 A
75 44 VS3 1.06 23 205 A
80 77 04H 0.94 22 166 A
81 46 VS5 0.84 23 206 A
81 148 05C
-0.02 22 167 A
84 53 VS2
-0.74 23 207 A
84 141 04C 0.75 22 168 A
88 61 02C 0.87 23 208 A
84 147 VS3 1.19 22 169 A
88 145 04C
-0.93 23 209 A
85 20 VS4 0.81 22 170 A
90 143 02C
-0.95 23 210 A
87 102 05H 0.92 22 171 A
91 116 VS2
-0.66 23 211 A
87 144 03C
-0.84 22 172 A
92 23 VS6 0.88 23 212 A
90 105 05C 0.8 22 173 A
97 50 VS4
-0.71 23 213 A
90 143 02C 0.04 22 174 A
97 52 VS2 0.82 23 214 A
94 31 VS4
-0.89 22 175 A
98 105 04C 0.63 23 215 A
97 50 VS6 0.74 22 176 A
100 27 VS4
-0.8 23 216 A
98 105 05C
-0.96 22 177 A
100 119 VS2
-0.64 23 217 A
100 103 02C 0.76 22 178 A
106 57 07H 1.02 23 218 A
104 87 04C
-0.96 22 179 A
106 135 VS4
-0.52 23 219 A
104 95 VS2
-0.51 22 180 A
111 130 04C
-0.24 23 220 A
106 59 VS6
-0.71 22 181 A
112 59 VS4 0.02 23 221 A
111 128 03C
-0.98 22 182 A
117 40 VS4
-0.69 23 222 A
125 112 03C 0
22 183 A
118 105 04C 0.76 23 223 A
131 94 08H 0.99 22 184 A
118 125 VS7
-0.93 23 224 A
133 92 VS6 0.84 22 185 A
125 48 VS4
-0.68 23 225 A
137 74 VS1 0.92 22 186 A
130 95 VS4
-0.95 23 226 A
137 78 VS4 1.06 22 187 A
134 65 07H
-0.04 23 227 A
19 64 DBH
-1.49 21 188 A
136 91 08C
-1.05 23 228 A
31 128 VS4 1.03 21 189 A
28 19 VS4
-1.05 22 229 A
44 21 VS4
-0.2 21 190 A
32 7
02C
-0.99 22 230 A
44 49 05C
-0.98 21 191 A
37 62 04H 0.95 22 231 A
47 124 VS4 0.15 21 192 A
40 147 VS4
-0.16 22 232 A
47 124 VS4 0.95 21 193 A
42 43 04H 0.84 22 233 A
49 112 VS4
-0.02 21 194 A
46 125 VS4 0.05 22 234 A
54 81 DBH 1.76 21 Page C-3
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 235 A
55 140 06C
-0.11 21 275 A
138 81 VS4 1.06 21 236 A
56 81 DBH 1.81 21 276 A
1 150 02C 0.77 20 237 A
58 127 04C 0.76 21 277 A
37 34 DBC 1.5 20 238 A
62 33 03H 0.99 21 278 A
37 56 04H 0.98 20 239 A
66 31 04H 0.9 21 279 A
37 128 VS4 1
20 240 A
70 55 03C
-0.9 21 280 A
39 126 03C 0.82 20 241 A
71 126 05C 0.82 21 281 A
42 7
02C 0.74 20 242 A
73 44 06C
-1.03 21 282 A
44 123 VS4 0.02 20 243 A
75 50 VS3
-0.81 21 283 A
45 108 03C 0.78 20 244 A
79 82 03H 0.95 21 284 A
50 157 VS3 0.87 20 245 A
79 90 04C
-0.25 21 285 A
51 118 02C
-0.95 20 246 A
84 19 VS4
-0.97 21 286 A
63 122 03C 0.69 20 247 A
87 40 07C 0.8 21 287 A
66 109 02C 0.8 20 248 A
87 146 VS4 0.54 21 288 A
67 136 VS3 0.78 20 249 A
88 21 VS4
-0.81 21 289 A
68 21 VS4 0.96 20 250 A
88 53 07C 0.81 21 290 A
68 81 03H 0.9 20 251 A
88 145 VS4 0.83 21 291 A
68 141 DBH 1.81 20 252 A
93 60 VS2 1.09 21 292 A
72 127 04C 0.78 20 253 A
95 136 VS2
-0.81 21 293 A
74 15 VS4 0.77 20 254 A
97 50 VS4 1.04 21 294 A
75 120 03C 0.87 20 255 A
97 118 VS4 0.63 21 295 A
79 150 VS4 1
20 256 A
97 134 VS4 0.9 21 296 A
80 147 07H 0.74 20 257 A
98 87 06C 0.92 21 297 A
81 84 07C
-0.13 20 258 A
102 29 VS4
-0.86 21 298 A
81 130 VS3 0
20 259 A
102 117 03H 0.89 21 299 A
81 148 02C 0.82 20 260 A
107 134 VS4
-0.94 21 300 A
82 141 VS3
-0.88 20 261 A
108 63 VS2 0.83 21 301 A
83 100 04H 0.92 20 262 A
113 128 04H
-0.85 21 302 A
84 33 VS2
-0.72 20 263 A
121 44 VS4 0.24 21 303 A
84 85 04H 0.94 20 264 A
125 110 03C 0.8 21 304 A
85 92 02C 0.82 20 265 A
125 112 07H
-0.2 21 305 A
90 93 03C 0.69 20 266 A
126 115 02C
-1 21 306 A
92 125 03H 0.58 20 267 A
128 53 02H
-0.89 21 307 A
93 130 VS2
-0.63 20 268 A
130 57 08H 0.88 21 308 A
93 130 VS4
-0.84 20 269 A
131 96 06C 0.91 21 309 A
94 101 04C
-1.06 20 270 A
132 91 DBC
-1.96 21 310 A
95 48 06C 0.85 20 271 A
135 90 08C 0.72 21 311 A
95 132 VS2 0.87 20 272 A
137 78 VS4
-0.58 21 312 A
96 63 04C 0.76 20 273 A
137 80 VS6
-0.95 21 313 A
96 131 04C
-1 20 274 A
137 92 07C
-0.8 21 314 A
97 90 VS6
-0.75 20 Page C-4
ATTACHMENT 1 to AREVA-17-Q2174 fA Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 315 A
97 116 VS4
-0.86 20 355 A
63 124 04C 0.82 19 316 A
97 126 VS4 0
20 356 A
65 90 02C 0.78 19 317 A
98 27 VS2 0.73 20 357 A
66 113 03H 1
19 318 A
98 127 07H 0.77 20 358 A
68 21 VS4
-0.87 19 319 A
99 26 VS4
-0.37 20 359 A
69 22 VS4
-0.09 19 320 A
100 29 VS2 0.93 20 360 A
70 115 DBH 1.76 19 321 A
101 138 VS4 0.6 20 361 A
72 143 DBC 1.42 19 322 A
104 123 04C 0.82 20 362 A
75 68 02C 0.82 19 323 A
105 132 03C 0.85 20 363 A
75 150 02C 0.8 19 324 A
106 33 VS4
-0.64 20 364 A
77 92 02C
-0.95 19 325 A
106 35 03C 0.67 20 365 A
78 17 DBH
-1.55 19 326 A
112 41 VS4
-0.94 20 366 A
83 90 07H 0.93 19 327 A
118 63 VS4
-0.92 20 367 A
84 37 VS2
-0.83 19 328 A
120 119 03C 0.8 20 368 A
85 26 03H 0.88 19 329 A
120 121 05C 0.82 20 369 A
86 145 04C 0.78 19 330 A
126 51 03H 0.95 20 370 A
87 20 VS4 0.56 19 331 A
126 115 04C 0.89 20 371 A
88 57 07C 0.84 19 332 A
128 71 VS1
-0.95 20 372 A
88 61 03C 0.8 19 333 A
130 73 VS7 0.84 20 373 A
90 95 04C 0.78 19 334 A
132 67 VS2
-1.05 20 374 A
90 135 04C 0.77 19 335 A
133 92 VS7 0
20 375 A
91 90 03C 0.78 19 336 A
134 95 VS4 0.93 20 376 A
92 89 04C 0.72 19 337 A
135 86 VS4 1.12 20 377 A
94 67 VS6
-0.89 19 338 A
135 100 02C 0.73 20 378 A
95 140 04C 0.67 19 339 A
2 127 05C 0.81 19 379 A
97 62 06C 0.77 19 340 A
13 2
02H 1.08 19 380 A
98 109 05C 0.71 19 341 A
13 34 03C
-0.95 19 381 A
101 28 VS4 0.65 19 342 A
24 161 02C 0.83 19 382 A
102 89 04C 0.76 19 343 A
24 163 02C 0.85 19 383 A
102 135 03C
-0.22 19 344 A
28 63 VS4
-1.06 19 384 A
103 32 VS4
-0.97 19 345 A
31 126 VS4
-0.63 19 385 A
104 97 04C
-0.91 19 346 A
34 109 04H 0.93 19 386 A
104 109 VS6
-0.52 19 347 A
38 127 03H 0.91 19 387 A
109 114 06C 0.75 19 348 A
44 123 VS4
-0.66 19 388 A
111 62 VS2
-0.79 19 349 A
49 66 VS4 1.06 19 389 A
112 37 02C
-0.97 19 350 A
50 21 DBH 1.63 19 390 A
112 59 VS4
-0.83 19 351 A
60 119 02C 0.86 19 391 A
116 51 07H 0.87 19 352 A
60 121 02C 0.8 19 392 A
116 119 03C 0.71 19 353 A
62 49 05H 1.03 19 393 A
116 123 06C 0.29 19 354 A
63 118 03C 0.85 19 394 A
118 41 VS4
-0.84 19 Page C-5
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 395 A
119 110 04C
-0.96 19 435 A
73 66 04C 0.74 18 396 A
121 118 VS4 0.83 19 436 A
75 50 VS3 1.03 18 397 A
127 72 VS6
-0.18 19 437 A
76 91 02C 0.78 18 398 A
129 56 02H 0.94 19 438 A
78 113 02C 0.77 18 399 A
130 71 VS4
-0.93 19 439 A
80 107 DBH 1.79 18 400 A
132 99 DBC 1.7 19 440 A
81 46 VS3 0.88 18 401 A
134 69 VS7 0.22 19 441 A
83 102 05C
-0.22 18 402 A
134 71 VS1 0.75 19 442 A
83 148 03C
-0.91 18 403 A
134 91 VS6
-0.63 19 443 A
84 19 VS4 0.96 18 404 A
135 76 DBC 1.9 19 444 A
84 39 VS3
-0.92 18 405 A
135 100 DBC 1.81 19 445 A
84 99 VS2
-0.83 18 406 A
135 100 VS6
-0.86 19 446 A
85 104 03C 0.85 18 407 A
136 91 07C
-1.2 19 447 A
85 146 02C 0.71 18 408 A
138 81 08C
-1.14 19 448 A
87 82 05H 0.96 18 409 A
138 81 VS7 0.18 19 449 A
87 92 04C 0.78 18 410 A
9 2
02C 0.07 18 450 A
87 146 VS4
-0.99 18 411 A
12 3
02C 0.72 18 451 A
88 59 05C 0.72 18 412 A
26 3
02C
-0.99 18 452 A
89 70 06C 0.83 18 413 A
31 128 VS4
-0.74 18 453 A
91 70 VS6 0.86 18 414 A
32 59 DBH 0.12 18 454 A
92 23 VS2 0.6 18 415 A
38 17 05H 0
18 455 A
92 101 VS2 0.82 18 416 A
42 117 02C 0.8 18 456 A
92 133 04C 0.82 18 417 A
44 49 04H 0.9 18 457 A
92 133 07H 0.92 18 418 A
48 29 03C 0.78 18 458 A
93 60 VS2
-0.62 18 419 A
48 43 VS4 0.83 18 459 A
94 95 07C
-0.89 18 420 A
49 10 VS4 1.04 18 460 A
95 124 VS2
-0.79 18 421 A
49 66 VS4 0.31 18 461 A
95 126 VS2 1.01 18 422 A
49 70 VS4 1.11 18 462 A
96 59 04C
-0.94 18 423 A
51 16 VS4
-0.74 18 463 A
96 87 05C 0.81 18 424 A
51 126 02C 0.07 18 464 A
96 111 04C 0.73 18 425 A
52 111 02C 0.86 18 465 A
97 50 VS2 0.87 18 426 A
52 149 VS3 1.17 18 466 A
97 96 04C
-0.91 18 427 A
53 92 03C 0.89 18 467 A
98 27 VS6 0.96 18 428 A
54 29 02C 0.71 18 468 A
98 85 06C 0.74 18 429 A
60 29 04H 0.95 18 469 A
99 138 02C
-0.91 18 430 A
63 104 03C 0.69 18 470 A
100 103 05C
-0.9 18 431 A
67 118 03C 0.85 18 471 A
100 107 VS4
-0.8 18 432 A
68 139 VS5
-0.83 18 472 A
100 113 DBH 1.82 18 433 A
69 134 06C
-0.85 18 473 A
100 137 05C
-0.88 18 434 A
70 137 06H 1.01 18 474 A
102 105 05C 0.78 18 Page C-6
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 475 A
102 135 04C 0.67 18 515 A
60 25 04H 0.82 17 476 A
106 31 04C 0.69 18 516 A
63 52 06C 0.82 17 477 A
106 35 03C
-0.09 18 517 A
63 126 04C 0.84 17 478 A
106 121 04C 0.76 18 518 A
65 40 03H 0.99 17 479 A
106 121 05C 0.4 18 519 A
65 126 06C
-1.1 17 480 A
108 35 01C 0.75 18 520 A
66 35 04H 0.9 17 481 A
108 41 VS4 0.94 18 521 A
66 89 04C
-0.94 17 482 A
108 123 VS2
-0.73 18 522 A
66 109 04C 0.78 17 483 A
109 120 03C
-0.2 18 523 A
67 154 01C
-0.57 17 484 A
109 132 04C 0.73 18 524 A
67 154 02C 0.71 17 485 A
110 39 VS2 0.97 18 525 A
69 30 DBC 1.33 17 486 A
111 44 06C
-0.2 18 526 A
71 78 06C
-0.96 17 487 A
111 110 VS4
-0.92 18 527 A
76 111 04C 0.75 17 488 A
112 103 04H 0.88 18 528 A
77 18 05H
-0.82 17 489 A
112 127 05C
-1.09 18 529 A
77 24 06H 0.75 17 490 A
114 123 03C
-1.03 18 530 A
77 62 03C 0.87 17 491 A
121 118 VS4 0
18 531 A
77 124 03C
-0.83 17 492 A
122 111 05C
-0.89 18 532 A
77 148 07H
-1.02 17 493 A
127 80 06C 0.78 18 533 A
80 149 VS4
-0.78 17 494 A
128 111 05C 0.69 18 534 A
81 102 07C
-0.96 17 495 A
134 99 04C
-0.82 18 535 A
82 33 VS3 1.01 17 496 A
135 72 VS1 0.95 18 536 A
82 89 05C 0.78 17 497 A
135 86 DBC
-1.7 18 537 A
82 135 VS3
-0.95 17 498 A
136 69 VS7
-0.88 18 538 A
83 76 02H 0.94 17 499 A
136 91 06C
-1 18 539 A
84 19 VS5 0.99 17 500 A
137 92 04C 0.69 18 540 A
84 73 05C 0.83 17 501 A
138 81 VS7 0.89 18 541 A
86 35 VS6
-0.64 17 502 A
32 145 VS4
-1.09 17 542 A
86 97 03H 0.94 17 503 A
37 38 03C 0.86 17 543 A
86 143 03C
-0.91 17 504 A
38 35 05H 0.9 17 544 A
87 40 07H
-0.93 17 505 A
39 120 04H 0.92 17 545 A
87 116 04C 0.8 17 506 A
43 46 VS4 1.2 17 546 A
89 26 VS6 0.92 17 507 A
44 15 DBH
-1.34 17 547 A
89 78 07H 0.98 17 508 A
45 12 DBH 1.78 17 548 A
90 87 03H 0.89 17 509 A
45 122 03C
-0.91 17 549 A
90 115 VS2
-0.74 17 510 A
48 41 VS4 0.97 17 550 A
91 66 05C 0.79 17 511 A
49 36 03C 0.71 17 551 A
91 114 VS2
-0.81 17 512 A
51 108 03C
-0.94 17 552 A
92 101 VS2
-0.78 17 513 A
54 83 03H 0.92 17 553 A
93 60 VS6
-0.93 17 514 A
54 119 02C 0.76 17 554 A
93 76 VS4 0.83 17 Page C-7
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 1 SO-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 555 A
93 106 VS2
-0.63 17 595 A
121 116 03C 0.78 17 556 A
93 136 03C
-0.95 17 596 A
127 114 VS4
-0.18 17 557 A
95 72 07C 0.78 17 597 A
128 85 DBH 1.74 17 558 A
95 84 05C 0.73 17 598 A
128 113 05C
-0.95 17 559 A
96 41 VS6 1.09 17 599 A
130 107 02C 0.93 17 560 A
96 111 05C 0.73 17 600 A
132 97 VS7
-0.79 17 561 A
96 121 VS6 1.19 17 601 A
133 64 05H
-0.07 17 562 A
97 26 VS4 0.51 17 602 A
133 94 VS2 0.78 17 563 A
97 48 VS4 0.98 17 603 A
135 72 VS7 0.83 17 564 A
97 64 06C
-0.92 17 604 A
136 85 08H
-1.04 17 565 A
97 90 05C 0.76 17 605 A
137 88 VS6
-0.11 17 566 A
97 106 VS4 0.91 17 606 A
137 90 05H
-0.81 17 567 A
98 55 05H 1.09 17 607 A
137 92 02C 0.79 17 568 A
98 59 05C
-0.95 17 608 A
137 92 08C
-0.6 17 569 A
98 75 06C 0.8 17 609 A
1 136 02H
-1 16 570 A
98 113 VS2 0.82 17 610 A
9 32 DBC 1.4 16 571 A
99 26 VS4
-0.71 17 611 A
11 146 03C 0.84 16 572 A
99 140 03C
-0.22 17 612 A
22 159 02H 1.03 16 573 A
100 29 06H 0.89 17 613 A
32 37 03H 0.94 16 574 A
100 29 VS4 0.95 17 614 A
33 46 02H 0.83 16 575 A
100 139 VS4
-0.8 17 615 A
35 114 DBC 1.61 16 576 A
101 28 VS4
-0.84 17 616 A
37 62 05H
-0.76 16 577 A
101 70 05H 0.91 17 617 A
37 106 03C
-0.84 16 578 A
102 113 05C 0.71 17 618 A
39 112 02C 0.78 16 579 A
103 30 VS4 0.54 17 619 A
40 59 05H 1.03 16 580 A
103 82 05H
-0.02 17 620 A
41 34 03H
-0.78 16 581 A
104 31 VS4 0.95 17 621 A
44 123 06H
-0.07 16 582 A
106 67 VS6 0.33 17 622 A
45 30 04H
-0.87 16 583 A
106 101 04H 0.86 17 623 A
46 69 VS4
-0.45 16 584 A
108 115 05H 0.96 17 624 A
47 8
01H
-0.85 16 585 A
110 131 03C 0.82 17 625 A
47 70 04H 1.05 16 586 A
111 126 04C 0.84 17 626 A
47 112 02C 0.8 16 587 A
112 125 04C 0.8 17 627 A
48 125 02C 0.75 16 588 A
113 36 VS4
-0.39 17 628 A
49 92 03C
-0.97 16 589 A
113 118 04C 0.07 17 629 A
50 91 VS4 0.83 16 590 A
115 46 VS4
-0.93 17 630 A
50 123 04C 0.02 16 591 A
116 45 02H 0.88 17 631 A
51 126 03C
-0.87 16 592 A
116 111 05C
-0.13 17 632 A
52 31 03C 0.88 16 593 A
120 115 05C
-1.03 17 633 A
56 115 02C 0.75 16 594 A
121 44 01C
-1.09 17 634 A
56 137 03C 0.11 16 Page C-S
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 635 A
61 150 DBC 1.58 16 675 A
92 23 VS2 0.97 16 636 A
63 140 DBC 1.35 16 676 A
92 133 05C
-0.93 16 637 A
64 13 VS4
-0.91 16 677 A
93 26 VS4
-0.77 16 638 A
65 106 04C 0.76 16 678 A
93 76 VS4 0.23 16 639 A
65 108 03H
-0.81 16 679 A
93 104 VS6
-0.7 16 640 A
66 27 06C 0.93 16 680 A
93 130 VS2 0.96 16 641 A
66 35 03H 0.9 16 681 A
94 27 03H 0.94 16 642 A
66 61 04H 1
16 682 A
95 24 VS4 0.18 16 643 A
66 109 04C 0.02 16 683 A
95 30 VS6
-0.02 16 644 A
67 120 VS5 1.01 16 684 A
95 130 VS2 0.88 16 645 A
68 21 VS5 0.85 16 685 A
96 61 06C 0
16 646 A
69 136 VS5 0.71 16 686 A
96 103 05C 0.78 16 647 A
70 69 05H
-0.02 16 687 A
96 105 VS6
-0.59 16 648 A
70 107 04C
-0.89 16 688 A
97 26 VS4
-0.84 16 649 A
73 14 VS4
-1.03 16 689 A
97 48 VS4
-0.78 16 650 A
75 16 06C
-0.02 16 690 A
97 48 VS6 0.96 16 651 A
76 17 DBC 1.59 16 691 A
97 58 07C 0.86 16 652 A
76 101 03H 0.9 16 692 A
97 62 05C
-0.98 16 653 A
77 102 03H 0.88 16 693 A
98 51 05C 0.8 16 654 A
77 122 06C 0.72 16 694 A
99 36 VS4 0.83 16 655 A
79 72 VS3 0
16 695 A
99 84 VS6
-0.98 16 656 A
81 46 VS3 0.05 16 696 A
99 112 04C 0.78 16 657 A
83 122 VS2 0.82 16 697 A
99 138 VS4 0.81 16 658 A
84 29 VS2 0.71 16 698 A
99 140 03C
-1 16 659 A
84 45 VS6
-0.76 16 699 A
100 89 VS2
-0.74 16 660 A
85 84 05H 0.95 16 700 A
101 30 04H
-0.07 16 661 A
86 55 06C 0.79 16 701 A
101 124 07C 0.76 16 662 A
86 111 05C 0.85 16 702 A
103 30 05H
-0.88 16 663 A
87 22 VS4
-0.96 16 703 A
103 82 06H 1.04 16 664 A
87 58 VS2
-0.77 16 704 A
103 96 05C 0.78 16 665 A
87 60 VS2
-0.76 16 705 A
104 31 VS4
-1.01 16 666 A
87 120 VS2 0.64 16 706 A
105 90 05C 0.76 16 667 A
88 53 VS4 0.95 16 707 A
107 44 05H
-0.16 16 668 A
88 73 02H
-0.04 16 708 A
107 44 VS2 0.69 16 669 A
88 91 04H 0.9 16 709 A
107 124 VS2
-0.22 16 670 A
89 32 03C
-1 16 710 A
108 133 04C
-0.95 16 671 A
89 72 01C 0.78 16 711 A
110 35 01H 0.93 16 672 A
89 84 04H
-0.77 16 712 A
110 131 01H 0.11 16 673 A
90 87 02C 0.82 16 713 A
113 42 VS4
-0.84 16 674 A
90 143 03C
-0.96 16 714 A
115 78 06H
-0.75 16 Page C-9
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 715 A
118 51 06C 0.78 16 755 A
46 141 04C 0.84 15 716 A
119 60 VS4
-0.81 16 756 A
47 50 VS4 1.07 15 717 A
119 122 06H 0.81 16 757 A
48 29 04H 0.88 15 718 A
119 124 VS4
-0.8 16 758 A
49 28 03C 0.78 15 719 A
120 81 07C 0.83 16 759 A
51 70 05H 0.93 15 720 A
120 111 04C 0.04 16 760 A
51 90 04C
-0.22 15 721 A
120 123 01H
-0.11 16 761 A
53 56 03H 0.91 15 722 A
123 114 04C
-0.93 16 762 A
57 142 03C 0.8 15 723 A
124 51 03H 0.93 16 763 A
58 85 03H 0.99 15 724 A
125 112 VS6
-0.8 16 764 A
58 121 02C 0.8 15 725 A
126 69 VS4
-0.89 16 765 A
61 44 04H
-0.04 15 726 A
126 111 VS7 1.05 16 766 A
61 48 06H 0.89 15 727 A
127 108 05C
-1.05 16 767 A
62 11 01C
-0.98 15 728 A
128 55 VS7 1.2 16 768 A
62 15 06C 0.76 15 729 A
128 69 08H 1.03 16 769 A
62 35 03H 0.94 15 730 A
128 71 VS2 0
16 770 A
63 84 DBH
-1.87 15 731 A
128 77 07C 0.83 16 771 A
64 13 04H 0.97 15 732 A
131 94 08H
-0.81 16 772 A
64 59 05C 0.7 15 733 A
131 106 03C
-0.47 16 773 A
65 116 VS3 1.01 15 734 A
133 94 VS4
-0.69 16 774 A
66 25 04H 0.86 15 735 A
133 94 VS6 0.93 16 775 A
66 59 06C 0.82 15 736 A
134 65 05H
-0.02 16 776 A
68 21 VS5 0.12 15 737 A
135 82 08H 0.91 16 777 A
69 40 04H 0.94 15 738 A
137 76 VS6 0.07 16 778 A
69 54 03C
-0.96 15 739 A
137 78 VS7 0.73 16 779 A
69 126 DBC 1.31 15 740 A
137 80 VS7 0.16 16 780 A
70 85 03H 0.96 15 741 A
138 75 07H 0.93 16 781 A
70 143 DBH 1.89 15 742 A
138 75 08C
-0.04 16 782 A
70 145 DBC
-1.85 15 743 A
138 81 VS4
-0.93 16 783 A
71 54 04H 1.02 15 744 A
138 89 VSl 0.81 16 784 A
71 134 VS3
-0.59 15 745 A
26 163 01H 0.97 15 785 A
72 55 03C
-0.92 15 746 A
33 124 03C 0.84 15 786 A
74 19 DBC 1.24 15 747 A
37 24 05C 0.85 15 787 A
74 145 DBC 1.76 15 748 A
37 50 04H 0.92 15 788 A
75 32 DBH 1.69 15 749 A
40 5
01C
-0.99 15 789 A
76 51 VS4 0.95 15 750 A
41 16 05H
-0.5 15 790 A
76 97 04C 0.82 15 751 A
41 160 01H 1.03 15 791 A
77 16 DBC 1.93 15 752 A
42 59 04H 0.87 15 792 A
77 22 06H 0.78 15 753 A
43 106 03C 0.76 15 793 A
77 44 VS3 1.06 15 754 A
45 134 03C 0.73 15 794 A
77 144 04C 0.78 15 Page C-10
ATTACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51 -9275005-000 AREVA Palisades 1R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 795 A
78 25 05C
-0.99 15 835 A
99 28 VS4 1
15 796 A
78 25 DBC
-1.97 15 836 A
99 104 02C
-0.99 15 797 A
79 68 07H 1.07 15 837 A
99 136 VS4
-0.89 15 798 A
79 104 05H 0.97 15 838 A
99 138 03C
-0.42 15 799 A
79 116 03C
-0.98 15 839 A
99 138 VS4 0.18 15 800 A
79 150 02C 0.02 15 840 A
100 139 03C
-0.18 15 801 A
81 18 01H 0.97 15 841 A
101 30 VS4
-0.89 15 802 A
81 18 VS4
-0.74 15 842 A
101 106 04C 0.84 15 803 A
82 61 VS3
-0.7 15 843 A
101 110 VS2 0.75 15 804 A
83 148 VS4
-1.06 15 844 A
102 73 07C
-0.9 15 805 A
85 62 04C 0.83 15 845 A
103 86 VS2 0.66 15 806 A
86 145 03C
-1.02 15 846 A
104 99 06C 0.78 15 807 A
87 20 VS4
-0.27 15 847 A
104 103 05C 0.74 15 808 A
87 100 04H 0.99 15 848 A
105 32 01C
-0.02 15 809 A
87 112 04H 0.94 15 849 A
105 136 VS4 1
15 810 A
88 59 05C 0
15 850 A
106 31 VS4 1.01 15 811 A
89 108 05H 0.97 15 851 A
106 63 VS4 0.34 15 812 A
89 112 05H 0.86 15 852 A
106 117 06C
-1.05 15 813 A
90 93 04C 0.69 15 853 A
107 130 03C
-0.88 15 814 A
90 95 06C 0.76 15 854 A
107 134 VS4 0.74 15 815 A
90 95 07C 0.2 15 855 A
112 89 VS4
-0.82 15 816 A
92 35 06H 0.89 15 856 A
112 125 05C
-0.95 15 817 A
92 59 VS4 0.84 15 857 A
113 42 VS4 1.07 15 818 A
92 69 05C 0.04 15 858 A
113 68 VS2
-0.7 15 819 A
92 135 04C 0.69 15 859 A
113 76 VS6 0.83 15 820 A
93 26 VS4 1
15 860 A
114 129 08H
-0.93 15 821 A
94 69 05H
-0.8 15 861 A
115 90 VS2
-0.94 15 822 A
94 93 06C 0.8 15 862 A
115 124 04C
-1.05 15 823 A
95 118 VS2 0.09 15 863 A
116 39 VS6
-0.59 15 824 A
95 142 02C 0.04 15 864 A
116 45 VS7 0.83 15 825 A
96 25 02H 0.87 15 865 A
117 122 VS4 0.11 15 826 A
96 41 04C 0.74 15 866 A
118 101 VS4 0.95 15 827 A
96 87 05H 1.04 15 867 A
119 42 VS4
-0.88 15 828 A
96 109 04C 0.85 15 868 A
119 122 03C 0.73 15 829 A
96 141 VS4 0.81 15 869 A
120 81 07C
-0.02 15 830 A
97 100 VS2 0.09 15 870 A
121 44 VS7 0.91 15 831 A
97 120 VS2
-0.8 15 871 A
122 53 06H 0.87 15 832 A
97 132 DBH 2.19 15 872 A
122 117 VS2
-0.91 15 833 A
97 132 VS4 0.97 15 873 A
126 77 VSl
-0.83 15 834 A
97 138 02C 0.77 15 874 A
126 77 VSl 0.87 15 Page C-11
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube I nspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 875 A
126 115 VS6
-0.74 15 915 A
51 126 02C 0.82 14 876 A
127 56 VS6 0.87 15 916 A
53 118 02C 0.82 14 877 A
127 106 VS4
-0.55 15 917 A
54 39 03H 0.85 14 878 A
128 101 VS2
-0.67 15 918 A
55 8
01C
-0.27 14 879 A
129 74 VS1
-0.82 15 919 A
55 88 02C
-0.97 14 880 A
129 112 VS2
-0.81 15 920 A
55 120 02C
-0.22 14 881 A
130 55 02H 0.92 15 921 A
55 122 02C
-0.16 14 882 A
130 107 03C
-0.27 15 922 A
57 18 VS3
-0.61 14 883 A
131 94 VS1 0.7 15 923 A
59 30 03C 0.75 14 884 A
132 67 VS2 0.8 15 924 A
59 106 02C 0.87 14 885 A
133 66 VS4
-0.63 15 925 A
61 34 03H 1.05 14 886 A
134 65 08H 0.86 15 926 A
61 112 04C
-0.98 14 887 A
134 65 VS1 0.86 15 927 A
61 138 DBC 1.51 14 888 A
135 78 VS1 0.98 15 928 A
62 19 06H 0.92 14 889 A
135 94 VS6
-0.68 15 929 A
62 59 04H 0.9 14 890 A
135 100 04C
-1.06 15 930 A
63 12 01C
-1 14 891 A
137 92 VS6 0.86 15 931 A
63 124 04C
-0.27 14 892 A
138 81 08H 0.89 15 932 A
64 11 VS5 0.65 14 893 A
138 83 08H
-1.19 15 933 A
64 37 VS5 0.91 14 894 A
1 128 02C 0.7 14 934 A
64 123 04C 0.8 14 895 A
3 164 03H
-0.42 14 935 A
65 16 05H 0.85 14 896 A
15 154 DBC 1.81 14 936 A
66 45 05H 0.99 14 897 A
22 3
02C
-0.98 14 937 A
66 107 03H 0.11 14 898 A
24 33 01H 0.83 14 938 A
67 20 VS5 0.66 14 899 A
25 110 04C 0.73 14 939 A
67 106 03H 0.86 14 900 A
34 63 DBC 1.71 14 940 A
67 120 06H 0
14 901 A
37 116 03C 0.78 14 941 A
67 130 DBH 1.76 14 902 A
37 128 VS4
-0.7 14 942 A
67 138 03C 0.78 14 903 A
39 14 05H
-0.22 14 943 A
67 154 04C 0.75 14 904 A
40 125 02C 0.82 14 944 A
68 17 VS3
-0.59 14 905 A
41 20 05H 0.93 14 945 A
68 53 04H
-0.11 14 906 A
41 126 02C
-0.89 14 946 A
70 15 VS4
-0.84 14 907 A
42 35 05C 0.89 14 947 A
70 81 DBC 1.7 14 908 A
43 46 03H
-0.39 14 948 A
70 153 VS3 0.89 14 909 A
44 109 03C 0.53 14 949 A
71 108 02C
-0.25 14 910 A
46 41 04H 0.88 14 950 A
71 108 05C 0.8 14 911 A
46 55 VS4
-0.94 14 951 A
71 150 06H 0.88 14 912 A
48 125 02C 0.02 14 952 A
72 53 02C 0.72 14 913 A
49 74 DBC 1.72 14 953 A
72 53 04C
-1.05 14 914 A
51 124 04C
-0.94 14 954 A
72 127 VS4
-0.12 14 Page C-12
ATTACHMENT 1 to AREVA-17-o2174 A
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 955 A
72 145 DBH 1.42 14 995 A
94 51 04C 0.76 14 956 A
73 14 VS4 1.01 14 996 A
94 57 05C 0.83 14 957 A
74 33 DBC 1.27 14 997 A
95 110 04H 0.96 14 958 A
74 149 DBC 1.57 14 998 A
96 37 VS6
-0.77 14 959 A
75 92 06H
-0.75 14 999 A
96 61 04H 0.24 14 960 A
76 57 02C 0.74 14 1000 A
97 46 VS6
-0.76 14 961 A
79 18 VS4
-0.79 14 1001 A
97 46 VS6
-0.18 14 962 A
79 72 04H 0.9 14 1002 A
97 48 VS6
-0.87 14 963 A
79 94 03C
-0.98 14 1003 A
97 54 05C
-0.22 14 964 A
79 150 02C 0.82 14 1004 A
97 114 VS4
-0.84 14 965 A
80 57 04H 0.91 14 1005 A
98 35 05H 0.85 14 966 A
80 119 03C 0.76 14 1006 A
98 39 05H 0.95 14 967 A
81 54 05C
-0.98 14 1007 A
98 63 05C
-0.88 14 968 A
81 94 DBH 1.8 14 1008 A
99 30 VS4
-0.88 14 969 A
82 19 VS4 0.66 14 1009 A
99 138 03H 0.88 14 970 A
83 90 05H
-0.07 14 1010 A
100 27 VS4
-0.11 14 971 A
83 148 07C 0.96 14 1011 A
100 27 VS4 1.04 14 972 A
83 148 VS4
-0.69 14 1012 A
100 29 05H 0.89 14 973 A
84 19 VS2 0.59 14 1013 A
100 31 VS2
-0.85 14 974 A
87 116 03C
-0.11 14 1014 A
100 119 VS4
-0.73 14 975 A
87 144 04C 0.73 14 1015 A
101 110 VS2 0.16 14 976 A
88 59 04C 0.69 14 1016 A
101 118 DBH 1.72 14 977 A
89 34 04H
-0.79 14 1017 A
102 67 07H 0.91 14 978 A
89 112 05H 0.15 14 1018 A
102 115 VS2
-0.52 14 979 A
89 136 03H 0.9 14 1019 A
103 30 VS4
-0.18 14 980 A
90 25 VS4 0.94 14 1020 A
104 61 06C 0.82 14 981 A
90 101 02C 0.04 14 1021 A
105 136 VS4
-0.65 14 982 A
90 107 05C 0.85 14 1022 A
106 31 03C 0.76 14 983 A
90 115 VS6
-0.59 14 1023 A
106 31 VS6 0.28 14 984 A
90 135 04H 0.98 14 1024 A
106 47 04C 0
14 985 A
91 144 VS4 0.74 14 1025 A
106 47 04C 0.76 14 986 A
92 29 03H 0.93 14 1026 A
106 59 VS2
-0.93 14 987 A
92 33 04H 0.9 14 1027 A
106 117 VS2
-0.06 14 988 A
92 141 02C
-0.22 14 1028 A
107 34 VS4 0.98 14 989 A
92 141 04C 0.87 14 1029 A
107 44 05H
-0.95 14 990 A
93 60 VS6 0.96 14 1030 A
107 120 DBH 1.8 14 991 A
93 94 04C 0.81 14 1031 A
107 122 03C
-0.18 14 992 A
93 130 03H
-0.67 14 1032 A
107 130 VS2
-0.8 14 993 A
93 138 05C 0.86 14 1033 A
108 95 03C 0.8 14 994 A
94 25 VS4
-0.84 14 1034 A
108 99 DBH 1.83 14 Page C-13
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube I nspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1035 A
109 34 05H
-0.75 14 1075 A
45 42 VS4 0.93 13 1036 A
109 118 04C
-1.02 14 1076 A
45 60 04H 1.01 13 1037 A
110 115 08H 0.9 14 1077 A
46 37 03H 0.92 13 1038 A
112 65 VS4 0.74 14 1078 A
48 69 VS4
-0.91 13 1039 A
113 68 VS4
-0.85 14 1079 A
49 24 VS4
-0.86 13 1040 A
113 68 VS6 1.07 14 1080 A
50 127 03C
-0.9 13 1041 A
115 124 03C 0.83 14 1081 A
51 122 02C
-0.22 13 1042 A
116 121 VS7 1.02 14 1082 A
53 10 01C
-1.02 13 1043 A
117 58 06C 0.8 14 1083 A
54 33 03H 0.88 13 1044 A
118 47 02H 0.9 14 1084 A
59 56 DBH
-0.81 13 1045 A
118 97 VS2
-0.92 14 1085 A
60 33 DBC 1.69 13 1046 A
118 99 VS2 0.89 14 1086 A
60 39 04H 0.87 13 1047 A
119 60 VS4 1
14 1087 A
63 134 03C 0.71 13 1048 A
120 93 06C 0.85 14 1088 A
63 142 04C 0.78 13 1049 A
121 104 VS4 0.76 14 1089 A
64 57 06C 0.83 13 1050 A
123 120 02H 0.93 14 1090 A
66 13 01C
-1.08 13 1051 A
124 49 01H 0.93 14 1091 A
66 13 VS4
-0.79 13 1052 A
124 117 03C 0
14 1092 A
66 107 02C
-0.98 13 1053 A
129 92 VS4
-0.86 14 1093 A
68 41 04H 0.99 13 1054 A
130 73 VS6 1
14 1094 A
69 34 06C 0.92 13 1055 A
130 89 DBC
-1.6 14 1095 A
69 34 DBH 1.67 13 1056 A
132 81 DBC 1.84 14 1096 A
69 60 06H 0.89 13 1057 A
133 88 DBC 1.65 14 1097 A
70 129 DBC 1.85 13 1058 A
134 65 DBH
-2.01 14 1098 A
70 153 DBH
-1.54 13 1059 A
134 71 VS1
-0.02 14 1099 A
n 55 04C
-0.31 13 1060 A
134 103 02C
-0.93 14 1100 A
73 152 VS3 1.03 13 1061 A
137 76 VS2
-0.09 14 1101 A
75 20 04H
-0.77 13 1062 A
138 85 08H
-0.95 14 1102 A
75 28 DBH 1.83 13 1063 A
138 85 VS6 0.96 14 1103 A
75 56 03C 0.8 13 1064 A
2 159 03C
-0.22 13 1104 A
76 53 03C 0.83 13 1065 A
3 128 02C 0.7 13 1105 A
77 18 06H
-0.67 13 1066 A
3 164 02C 0.77 13 1106 A
77 22 03H 0.88 13 1067 A
10 165 DBH 1.68 13 1107 A
77 76 VS5 0.92 13 1068 A
27 8
02C
-0.84 13 1108 A
79 18 DBC 1.34 13 1069 A
28 3
02C
-0.92 13 1109 A
79 144 VS5
-0.73 13 1070 A
29 162 01H
-0.76 13 1110 A
80 27 VS3 1.03 13 1071 A
34 117 03C
-0.95 13 1111 A
80 65 04C 0.78 13 10n A
37 34 04H 0.97 13 1112 A
80 77 02H
-0.87 13 1073 A
41 108 03C 0.8 13 1113 A
81 20 04H 0.93 13 1074 A
41 160 03C
-0.13 13 1114 A
81 94 02C
-0.96 13 Page C-14
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1115 A
81 130 VS3
-0.78 13 1155 A
100 61 03H
-0.8 13 1116 A
82 91 07C 0.81 13 1156 A
100 115 05H
-0.85 13 1117 A
83 146 04C
-0.93 13 1157 A
100 137 VS4
-0.9 13 1118 A
84 41 07H 0.92 13 1158 A
101 56 06C
-0.98 13 1119 A
84 47 06H 0.97 13 1159 A
101 128 04H
-0.75 13 1120 A
84 125 04C
-1.02 13 1160 A
102 75 VS2
-0.65 13 1121 A
84 143 03C 0.66 13 1161 A
102 95 05C
-0.2 13 1122 A
84 147 VS5 0.68 13 1162 A
102 105 03C
-0.94 13 1123 A
86 21 VS4
-0.81 13 1163 A
102 115 VS2
-0.06 13 1124 A
87 92 05C 0.78 13 1164 A
103 54 05H 0.91 13 1125 A
87 124 04C
-0.96 13 1165 A
103 86 VS2 0.22 13 1126 A
88 57 VS6 0.79 13 1166 A
103 134 04C 0.8 13 1127 A
88 125 04C
-0.91 13 1167 A
103 136 DBH
-1.53 13 1128 A
89 42 07H 0.86 13 1168 A
104 121 06C 0.78 13 1129 A
89 108 04H 0.99 13 1169 A
105 32 04H
-0.93 13 1130 A
89 128 03H 0.93 13 1170 A
106 31 01C
-0.99 13 1131 A
90 23 VS4
-0.89 13 1171 A
106 33 04C
-0.94 13 1132 A
90 59 04H 0.97 13 1172 A
106 69 VS2 0.62 13 1133 A
92 59 VS4
-0.86 13 1173 A
106 69 VS6 0.97 13 1134 A
93 136 03C 0.8 13 1174 A
107 32 03C 0.84 13 1135 A
94 57 VS6
-0.82 13 1175 A
107 32 VS4
-0.05 13 1136 A
94 61 04H 1.02 13 1176 A
107 134 03H 0.82 13 1137 A
94 67 VS6 0.84 13 1177 A
109 34 01H 0.98 13 1138 A
94 77 VS2
-0.68 13 1178 A
109 34 04H
-0.72 13 1139 A
95 130 04H 0.98 13 1179 A
109 114 03C 0.82 13 1140 A
95 132 VS4 0.99 13 1180 A
112 39 VS6 0.97 13 1141 A
96 31 VS6
-0.59 13 1181 A
112 129 04C 0.69 13 1142 A
96 39 VS6 0.32 13 1182 A
113 38 02C 0.81 13 1143 A
96 61 06H 1
13 1183 A
113 90 VS4
-0.53 13 1144 A
96 65 05H
-0.83 13 1184 A
115 38 02C
-1.02 13 1145 A
96 105 07H 0.91 13 1185 A
115 38 02C
-0.02 13 1146 A
96 117 VS6
-0.66 13 1186 A
115 50 VS4
-0.71 13 1147 A
96 141 VS4
-1.15 13 1187 A
115 128 05H 0.85 13 1148 A
97 132 04C
-1.04 13 1188 A
116 81 VS6
-0.81 13 1149 A
98 55 DBC
-1.71 13 1189 A
116 95 07C
-0.98 13 1150 A
98 111 VS2 0.55 13 1190 A
117 42 02C 0.81 13 1151 A
99 104 02C 0
13 1191 A
118 41 01H 0.99 13 1152 A
100 29 04H 0.88 13 1192 A
118 53 VS6
-0.78 13 1153 A
100 35 03H
-0.73 13 1193 A
118 63 VS4 0.82 13 1154 A
100 41 06C 0.74 13 1194 A
119 82 VS4 0.32 13 Page C-15
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1195 A
121 120 06H 0.9 13 1235 A
69 108 04H 1.01 12 1196 A
122 45 01C 0.8 13 1236 A
70 19 05H 0.98 12 1197 A
122 113 03C 0.58 13 1237 A
72 149 DBH 1.62 12 1198 A
123 52 06H
-0.91 13 1238 A
73 14 05H
-0.9 12 1199 A
127 56 VSl
-0.78 13 1239 A
73 152 VS3
-0.66 12 1200 A
127 56 VS4 1.04 13 1240 A
75 20 03H 0.9 12 1201 A
127 76 VSl
-0.93 13 1241 A
75 58 VS3 0.95 12 1202 A
128 55 VS6
-0.04 13 1242 A
76 51 04C 0.07 12 1203 A
131 70 DBC 1.69 13 1243 A
76 51 VS3
-0.79 12 1204 A
131 76 06C 0.74 13 1244 A
76 103 03H
-0.07 12 1205 A
132 63 VS6 0.92 13 1245 A
77 24 03H 0.94 12 1206 A
133 60 02H
-0.87 13 1246 A
77 44 VS4 0.12 12 1207 A
133 86 DBC
-1.66 13 1247 A
77 52 02C 0.78 12 1208 A
133 94 DBC
-1.84 13 1248 A
78 19 DBC
-2 12 1209 A
134 89 DBC
-1.82 13 1249 A
78 149 DBC
-1.62 12 1210 A
137 90 DBC 0.81 13 1250 A
79 16 DBH
-1.36 12 1211 A
138 85 DBC
-1.71 13 1251 A
80 143 05C 0.73 12 1212 A
13 2
02H
-0.86 12 1252 A
80 145 02C
-0.37 12 1213 A
18 51 VS4
-1.12 12 1253 A
81 24 DBC
-1.63 12 1214 A
24 161 02C
-0.9 12 1254 A
81 118 VS3
-0.76 12 1215 A
41 6
02C
-0.18 12 1255 A
82 71 VS3 0.89 12 1216 A
41 8
02C
-0.33 12 1256 A
83 130 VS2 0.88 12 1217 A
43 46 VS4 0.09 12 1257 A
83 136 DBH 1.62 12 1218 A
47 12 DBC 1.46 12 1258 A
84 29 05C
-1.05 12 1219 A
47 24 04H
-0.74 12 1259 A
84 51 VS2 0.65 12 1220 A
50 45 VS5
-0.86 12 1260 A
87 36 DBH 1.89 12 1221 A
52 9
01C
-1.05 12 1261 A
87 40 VS2
-0.92 12 1222 A
58 33 DBH 1.74 12 1262 A
87 56 04C 0.78 12 1223 A
61 34 04H 0.92 12 1263 A
87 146 02C 0.73 12 1224 A
61 40 04H 0.88 12 1264 A
88 57 06H 0.89 12 1225 A
63 58 03H 0.93 12 1265 A
88 125 03C
-0.88 12 1226 A
64 29 DBC 1.43 12 1266 A
89 28 VS6 0.75 12 1227 A
64 139 03C 0.86 12 1267 A
90 31 04H 0.93 12 1228 A
65 24 VS5
-0.91 12 1268 A
90 107 04H 0.99 12 1229 A
66 37 06H
-0.02 12 1269 A
92 25 VS4 0.94 12 1230 A
66 55 02H 0.94 12 1270 A
92 59 VS6 1.18 12 1231 A
67 38 06H 0.97 12 1271 A
92 85 VS6 1.04 12 1232 A
67 50 03C 0.76 12 1272 A
92 117 VS4
-0.71 12 1233 A
68 45 06H 1.01 12 1273 A
93 100 VS2
-0.7 12 1234 A
68 107 03H
-0.13 12 1274 A
95 58 04H 0.99 12 Page C-16
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1275 A
95 60 06H 0.95 12 1315 A
118 43 03H 0.93 12 1276 A
95 142 02C 0.8 12 1316 A
118 101 04H
-0.09 12 1277 A
96 41 VS6
-0.14 12 1317 A
120 111 03C
-1.04 12 1278 A
96 59 07C
-0.9 12 1318 A
123 102 VS4 1.05 12 1279 A
97 48 DBC 1.82 12 1319 A
124 119 VS4
-0.87 12 1280 A
97 96 VS2 0.11 12 1320 A
126 51 VS2 0.79 12 1281 A
97 96 VS2 0.71 12 1321 A
126 63 07H 1
12 1282 A
97 112 VS4
-0.89 12 1322 A
127 80 VS7 0.78 12 1283 A
97 120 VS4 0.68 12 1323 A
128 103 VS2 0.97 12 1284 A
97 136 04C
-1.04 12 1324 A
129 86 DBH 1.78 12 1285 A
98 85 VS6
-0.71 12 1325 A
132 59 01C 0.67 12 1286 A
99 30 VS4 0.85 12 1326 A
134 91 VS6 1.02 12 1287 A
99 116 VS4
-0.84 12 1327 A
134 103 DBC
-1.68 12 1288 A
99 138 02C 0.04 12 1328 A
135 82 VS4
-0.78 12 1289 A
100 31 06H
-0.83 12 1329 A
136 69 VS7 0.95 12 1290 A
100 31 06H
-0.04 12 1330 A
136 79 VS7
-0.85 12 1291 A
100 49 05C 0.8 12 1331 A
136 79 VS7 0.95 12 1292 A
101 36 03H 0.88 12 1332 A
136 93 VS6 0.75 12 1293 A
101 48 DBC 1.64 12 1333 A
137 74 DBH 2.03 12 1294 A
102 137 04C
-1.04 12 1334 A
137 88 VS4
-0.53 12 1295 A
103 30 07H
-0.81 12 1335 A
137 88 VS6
-0.63 12 1296 A
103 32 02C
-0.22 12 1336 A
138 81 VS1 1.03 12 1297 A
103 134 04C 0
12 1337 A
138 83 VS1
-0.72 12 1298 A
104 33 04C
-0.95 12 1338 A
1 150 01C
-0.18 11 1299 A
106 69 VS4
-1.14 12 1339 A
4 115 04C 0.86 11 1300 A
107 32 04C
-0.27 12 1340 A
4 137 02C 0.75 11 1301 A
107 40 VS2
-0.86 12 1341 A
22 9
02C
-0.99 11 1302 A
107 44 VS4 0.9 12 1342 A
22 163 02H
-0.78 11 1303 A
107 124 03C
-0.94 12 1343 A
26 161 03H 0.94 11 1304 A
107 128 04C
-1.14 12 1344 A
27 6
02H
-0.74 11 1305 A
108 39 04H 0.89 12 1345 A
31 44 02C 0.82 11 1306 A
108 133 04C 0.71 12 1346 A
31 126 VS4 0.3 11 1307 A
109 34 VS4
-0.84 12 1347 A
32 109 VS4
-0.12 11 1308 A
111 128 03C 0.82 12 1348 A
34 39 02H 1.08 11 1309 A
111 128 VS4 1
12 1349 A
34 119 03H 0.97 11 1310 A
112 65 VS4
-0.78 12 1350 A
39 40 02H 0.94 11 1311 A
113 36 01H 0.95 12 1351 A
42 5
VS4
-0.8 11 1312 A
113 38 01C
-1.04 12 1352 A
49 112 VS4
-0.6 11 1313 A
116 39 01C
-0.18 12 1353 A
51 134 VS3
-0.77 11 1314 A
116 51 05H
-0.13 12 1354 A
58 33 04H
-0.88 11 Page C-17
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1355 A
61 36 03H
-0.86 11 1395 A
89 54 07C 0.82 11 1356 A
62 33 03H
-0.84 11 1396 A
91 144 03C
-0.98 11 1357 A
63 44 06C
-1.01 11 1397 A
92 51 05C 0.02 11 1358 A
64 71 VS5 0.88 11 1398 A
93 52 04C 0.74 11 1359 A
65 14 06H 0.83 11 1399 A
93 104 DBH 1.61 11 1360 A
65 32 04H 0.88 11 1400 A
93 130 04H
-0.83 11 1361 A
65 76 02H
-0.09 11 1401 A
94 25 03H
-0.92 11 1362 A
66 31 05H
-0.81 11 1402 A
94 77 VS6
-0.84 11 1363 A
66 113 02C 0.77 11 1403 A
95 130 VS2 0.02 11 1364 A
66 137 06C
-0.98 11 1404 A
97 28 VS4
-0.41 11 1365 A
67 12 03H 0.88 11 1405 A
97 28 VS4 1
11 1366 A
67 32 06H 0.98 11 1406 A
97 124 VS2 1.01 11 1367 A
67 34 06C 0.91 11 1407 A
98 111 VS2
-0.17 11 1368 A
67 112 VS3 0.89 11 1408 A
98 119 VS6 0.82 11 1369 A
68 17 VS4 0.88 11 1409 A
99 84 VS6 0.96 11 1370 A
68 21 VS3
-0.82 11 1410 A
100 29 VS2
-0.87 11 1371 A
69 40 DBH 1.71 11 1411 A
100 29 VS4 0.02 11 1372 A
69 136 VS3
-0.64 11 1412 A
100 33 VS2
-0.8 11 1373 A
71 110 04H 0.94 11 1413 A
100 119 VS2 0.88 11 1374 A
72 47 04C
-0.2 11 1414 A
100 131 05C 0.71 11 1375 A
72 85 05C 0.16 11 1415 A
100 137 VS4 0.96 11 1376 A
72 151 01H
-0.09 11 1416 A
101 136 02C 0.02 11 1377 A
74 15 01C
-0.96 11 1417 A
102 29 04C
-1.03 11 1378 A
76 15 01C
-0.07 11 1418 A
102 105 02C 0.09 11 1379 A
76 15 03H
-0.11 11 1419 A
103 108 07C
-0.22 11 1380 A
76 15 06C 0.79 11 1420 A
104 71 DBH 1.8 11 1381 A
76 15 DBC 1.8 11 1421 A
104 97 03C 0.74 11 1382 A
76 21 04H 0.95 11 1422 A
106 47 DBC 1.68 11 1383 A
77 20 06H
-0.07 11 1423 A
106 63 VS4
-1.02 11 1384 A
79 22 07C 1.02 11 1424 A
107 124 VS2
-0.95 11 1385 A
80 57 04H 0.16 11 1425 A
107 130 VS2 0.58 11 1386 A
83 84 02C 0.85 11 1426 A
108 35 VS4
-0.9 11 1387 A
84 19 01H
-0.82 11 1427 A
108 63 VS2 0.22 11 1388 A
84 19 01H
-0.07 11 1428 A
111 116 03C 0.78 11 1389 A
84 19 VS3 0.19 11 1429 A
111 116 03H 0.92 11 1390 A
86 145 02C 0.73 11 1430 A
113 128 03H 0.89 11 1391 A
87 56 05H 0.89 11 1431 A
114 129 VS4 1.01 11 1392 A
87 90 04H 1.03 11 1432 A
115 38 VS4 0.82 11 1393 A
87 92 04H
-0.73 11 1433 A
115 124 05C 0.69 11 1394 A
87 120 VS2 0.11 11 1434 A
116 55 05H
-0.62 11 Page C-18
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1435 A
116 95 06C 0.76 11 1475 A
76 21 03H 0.84 10 1436 A
118 43 06H
-0.93 11 1476 A
76 97 04C
-1 10 1437 A
120 45 02H 0.88 11 1477 A
77 18 07C
-0.02 10 1438 A
123 110 VS2 0.96 11 1478 A
77 24 04H
-0.04 10 1439 A
125 114 03H
-0.17 11 1479 A
77 28 06H 0.88 10 1440 A
127 52 03C
-0.16 11 1480 A
77 52 03C
-0.98 10 1441 A
127 56 DBH 2.17 11 1481 A
77 52 06C
-0.94 10 1442 A
129 58 VS2
-0.81 11 1482 A
79 20 05H 0.85 10 1443 A
130 57 02H 1.01 11 1483 A
80 59 04C 0.76 10 1444 A
132 87 DBH 1.82 11 1484 A
81 18 DBC
-1.89 10 1445 A
133 60 02H 0.94 11 1485 A
82 101 DBH
-1.94 10 1446 A
135 78 VS4 1.03 11 1486 A
82 121 05H 0.88 10 1447 A
136 69 DBC
-1.41 11 1487 A
84 25 VS2 0.59 10 1448 A
1 162 01C 0.87 10 1488 A
84 51 DBH 1.67 10 1449 A
4 157 02C 0.73 10 1489 A
84 93 05C
-0.94 10 1450 A
5 130 02C 0.84 10 1490 A
85 28 VS3
-0.74 10 1451 A
27 10 05H 0.9 10 1491 A
86 145 03C 0.75 10 1452 A
33 22 DBH 2.09 10 1492 A
87 20 VS4
-0.98 10 1453 A
37 50 04H
-0.92 10 1493 A
87 22 01H 0.94 10 1454 A
38 11 05H 1.09 10 1494 A
87 22 04H 0.91 10 1455 A
39 10 DBH 1.91 10 1495 A
87 92 04H 0.98 10 1456 A
41 22 05H
-0.96 10 1496 A
87 110 03H 0.86 10 1457 A
48 43 VS4 0.21 10 1497 A
87 142 03C
-1.04 10 1458 A
50 21 DBC 1.58 10 1498 A
88 99 06H
-0.84 10 1459 A
57 32 06H
-0.04 10 1499 A
89 60 04H
-0.73 10 1460 A
63 40 DBC
-1.39 10 1500 A
89 112 05H
-0.7 10 1461 A
64 25 06C 0.87 10 1501 A
90 35 05H 0.85 10 1462 A
64 59 04C 0.81 10 1502 A
90 87 04C 0.44 10 1463 A
64 71 VS5
-0.84 10 1503 A
90 87 06H 0.94 10 1464 A
65 24 VS5 0.62 10 1504 A
91 22 VS6
-0.85 10 1465 A
65 32 DBC 1.33 10 1505 A
92 37 04H 0.92 10 1466 A
66 39 05H 0.92 10 1506 A
92 59 VS4 0.07 10 1467 A
66 109 03H
-0.67 10 1507 A
92 137 04C 0.84 10 1468 A
67 56 VS3 0.87 10 1508 A
94 107 03H
-0.26 10 1469 A
67 106 02H 1.03 10 1509 A
96 27 VS4 1.1 10 1470 A
69 58 02C 0.83 10 1510 A
96 31 VS4 0.86 10 1471 A
70 53 02C
-0.85 10 1511 A
96 33 06H
-0.92 10 1472 A
71 126 05C 0.07 10 1512 A
96 33 VS4
-0.92 10 1473 A
73 14 03H 0.91 10 1513 A
96 55 06C
-0.94 10 1474 A
75 148 06C 0.77 10 1514 A
97 46 VS4 0.92 10 Page C-19
ATTACHMENT 1 to AREVA-17-Q2174 A.
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1515 A
98 27 VS6
-0.87 10 1555 A
4 157 02C
-0.16 9
1516 A
98 85 DBC 1.28 10 1556 A
42 5
VS4 0
9 1517 A
98 109 05H
-0.87 10 1557 A
46 125 VS4 0.93 9
1518 A
99 28 VS4
-0.46 10 1558 A
61 20 DBC 1.24 9
1519 A
99 136 VS4 0.58 10 1559 A
61 144 DBH 1.88 9
1520 A
100 35 05C 0
10 1560 A
64 57 05H 0.99 9
1521 A
100 119 VS6 1.09 10 1561 A
65 12 01C
-0.22 9
1522 A
101 28 03H 0.95 10 1562 A
65 32 DBC
-1.32 9
1523 A
101 136 03C
-0.91 10 1563 A
68 39 VS3 0.98 9
1524 A
101 138 07C 0.72 10 1564 A
70 107 04H
-0.02 9
1525 A
103 36 05C
-0.96 10 1565 A
70 153 02C
-0.88 9
1526 A
104 85 VS2
-0.7 10 1566 A
71 34 03H
-0.91 9
1527 A
105 122 06C 0.73 10 1567 A
76 15 04H
-0.83 9
1528 A
106 45 05H 0
10 1568 A
76 51 VS3 1.01 9
1529 A
106 131 03C
-0.92 10 1569 A
76 57 05C
-0.94 9
1530 A
106 135 01H 0.15 10 1570 A
79 148 02C 0.8 9
1531 A
108 35 VS4 0.99 10 1571 A
81 94 02C
-0.24 9
1532 A
110 35 VS4 0.93 10 1572 A
82 107 04H 0.87 9
1533 A
112 37 DBH
-1.63 10 1573 A
83 50 05C 0.69 9
1534 A
112 41 VS6
-0.73 10 1574 A
84 93 05C
-0.22 9
1535 A
113 36 01H
-0.09 10 1575 A
87 88 04H 0.26 9
1536 A
114 119 03C 0.73 10 1576 A
88 33 04H 0.88 9
1537 A
115 38 VS4 0.4 10 1577 A
90 59 04H
-0.09 9
1538 A
116 71 VS4 1.08 10 1578 A
92 25 VS4
-0.91 9
1539 A
117 40 02C
-0.2 10 1579 A
92 117 VS4 0.91 9
1540 A
117 90 VS2 0.83 10 1580 A
93 116 DBH 1.76 9
1541 A
117 120 03H 0.83 10 1581 A
94 25 VS4
-0.09 9
1542 A
119 44 02H 0.88 10 1582 A
95 32 04H
-0.02 9
1543 A
121 44 VS4 0.89 10 1583 A
97 52 VS2
-0.88 9
1544 A
122 63 05H 0.13 10 1584 A
97 124 VS2
-0.86 9
1545 A
123 120 VS4
-0.52 10 1585 A
100 31 04H 0.86 9
1546 A
126 51 01H 0.09 10 1586 A
100 51 06H
-0.04 9
1547 A
126 103 VSl 0.94 10 1587 A
102 29 VS4
-0.11 9
1548 A
129 94 VS4 0.04 10 1588 A
102 105 03C 0.09 9
1549 A
130 93 DBH 1.94 10 1589 A
103 32 03C 0.09 9
1550 A
133 60 VS4 0.5 10 1590 A
103 36 VS2 0.99 9
1551 A
136 69 DBC 1.48 10 1591 A
104 33 03C
-1 9
1552 A
137 76 VS2
-0.74 10 1592 A
106 121 04C
-0.04 9
1553 A
138 81 VSl
-0.88 10 1593 A
107 36 03C 0.78 9
1554 A
138 81 VS2
-0.15 10 1594 A
109 34 01C 0.74 9
Page C-20
j ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1595 A
114 47 05H 0.97 9
1635 A
120 81 VS4 0.91 7
1596 A
122 117 VSl 0.89 9
1636 A
127 56 VSl 0.73 7
1597 A
130 99 03C
-0.97 9
1637 A
129 94 VS4 0.56 7
1598 A
132 97 08C 0
9 1638 A
133 94 DBC 1.14 7
1599 A
134 69 VS6 1.14 9
1639 A
67 24 06H 0.21 6
1600 A
134 71 VSl
-0.79 9
1640 A
67 38 06H
-0.07 6
1601 A
135 78 VS4 0.02 9
1641 A
72 29 DBC 1.84 6
1602 A
27 10 05H 0.09 8
1642 A
72 53 04C 0.81 6
1603 A
67 50 03C 0
8 1643 A
77 20 DBC
-1.21 6
1604 A
68 27 VS3
-0.74 8
1644 A
91 26 03H 0.91 6
1605 A
70 29 DBC 1.31 8
1645 A
92 23 VS6 0.56 6
1606 A
75 16 03H 0.94 8
1646 A
101 40 05H 0.11 6
1607 A
76 19 DBC 1.44 8
1647 A
106 31 VS2 0.16 6
1608 A
79 18 VS4 1.13 8
1648 A
107 32 04C
-0.85 6
1609 A
82 19 VS4
-0.96 8
1649 A
122 117 VS2 0.2 6
1610 A
83 114 VS2
-0.88 8
1650 A
123 110 06C
-0.29 6
1611 A
85 40 VS5
-0.77 8
1651 A
68 17 VS4
-1.02 5
1612 A
87 106 06H 0.22 8
1613 A
88 53 05C
-0.97 8
1614 A
89 78 07H
-0.81 8
1615 A
95 26 VS4 1.01 8
1616 A
101 30 VS4 0.73 8
1617 A
103 36 VS2
-0.84 8
1618 A
117 50 VS4
-0.62 8
1619 A
127 76 VS4 1.07 8
1620 A
135 94 VS4 0.95 8
1621 A
36 109 VS4 0
7 1622 A
68 15 05H
-0.09 7
1623 A
76 37 06H
-0.02 7
1624 A
80 17 VS4 0.65 7
1625 A
81 20 04H
-0.04 7
1626 A
83 116 VS2
-0.3 7
1627 A
87 90 04H
-0.04 7
1628 A
88 21 VS4 0.33 7
1629 A
91 90 05H 0.95 7
1630 A
103 32 VS4 0.49 7
1631 A
104 97 03C 0
7 1632 A
106 119 VS4 1.14 7
1633 A
107 124 VS2 0.61 7
1634 A
116 61 VS4 0.93 7
Page C-21
ATIACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report APPENDIX D:
SUPPORT WEAR LISTING - SGB Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1
B 44 31 VS4
-0.61 39 37 B
98 55 VS2
-0.77 33 2
B 49 34 VS4 0.84 39 38 B
109 114 VS6
-0.9 33 3
B 95 138 VS4 1.02 39 39 B
131 58 01C 0.76 33 4
B 109 52 VS2 0.83 39 40 B
131 98 VS6 0.93 33 5
B 109 114 VS4
-0.79 39 41 B
138 89 VS7 0.9 33 6
B 123 116 VS6
-0.58 39 42 B
42 123 VS4 0.97 32 7
B 135 92 VS7
-0.65 39 43 B
80 17 DBH 1.68 32 8
B 38 125 VS4 0.95 38 44 B
80 145 VS4
-0.64 32 9
B 39 116 VS4 0.94 38 45 B
107 82 VS2 0.83 32 10 B
107 42 VS2 0.8 38 46 B
114 37 VS2 0.04 32 11 B
42 57 VS4 0.81 37 47 B
131 98 VS7 0.84 32 12 B
114 39 VS4 0.88 37 48 B
135 90 VS7 0.53 32 13 B
115 38 01C
-0.04 37 49 B
45 122 VS4 1.02 31 14 B
42 51 VS4
-0.69 36 50 B
48 13 VS4 0.36 31 15 B
44 103 VS4 0.96 36 51 B
69 134 VS4
-0.71 31 16 B
46 151 VS4 0.88 36 52 B
71 144 VS3
-0.75 31 17 B
100 125 VS2 0.11 36 53 B
84 147 DBH 1.86 31 18 B
107 82 VS2
-0.99 36 54 B
105 30 VS4 0.83 31 19 B
135 92 08C 0.94 36 55 B
112 127 03C 0.04 31 20 B
41 54 VS4 0.79 35 56 B
124 93 VS2 0.06 31 21 B
42 41 VS4 0.93 35 57 B
136 97 VS7
-0.76 31 22 B
44 37 VS4 0.14 35 58 B
38 147 VS4
-0.62 30 23 B
107 42 VS2
-0.94 35 59 B
45 140 VS4 0.93 30 24 B
109 114 VS2
-0.08 35 60 B
47 126 VS4
-0.67 30 25 B
112 37 04C
-1.01 35 61 B
47 126 VS4 1.06 30 26 B
123 118 VS6
-0.72 35 62 B
72 49 03C 0.83 30 27 B
44 21 VS4 1.01 34 63 B
83 148 VS4
-1 30 28 B
48 9
VS4
-0.62 34 64 B
91 22 VS6 1
30 29 B
48 9
VS4 0.23 34 65 B
114 37 VS4 0.93 30 30 B
71 146 VS5
-0.86 34 66 B
116 125 03C 0.81 30 31 B
100 125 VS2
-0.6 34 67 B
135 92 07C 0.79 30 32 B
107 42 VS4 0.97 34 68 B
137 90 DBH 1.8 30 33 B
108 33 VS4 1.08 34 69 B
38 127 VS4 0.86 29 34 B
44 29 VS4 0.05 33 70 B
42 41 VS4 0.34 29 35 B
45 34 VS4 0.15 33 71 B
44 23 DBH
-1.61 29 36 B
87 146 03C 0.75 33 72 B
44 59 VS4 0
29 Page D-1
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 73 B
46 33 VS4
-0.55 29 113 B
67 138 VS3 0.14 27 74 B
47 20 VS4 1.01 29 114 B
71 36 VS5 0.06 27 75 B
47 56 VS4 1.15 29 115 B
72 125 06C 0.78 27 76 B
67 134 06C
-1.06 29 116 B
76 33 DBH 1.79 27 77 B
72 149 DBH 1.66 29 117 B
76 141 DBH 1.85 27 78 B
88 27 DBH 2.18 29 118 B
79 24 VS4 0.18 27 79 B
103 126 VS6 0.85 29 119 B
81 22 VS3 0.94 27 80 B
109 130 02C 0.68 29 120 B
82 43 VS3 0.02 27 81 B
131 104 VS7 0.82 29 121 B
82 143 VS3
-0.91 27 82 B
132 107 02C
-1.06 29 122 B
82 145 VS4 1.16 27 83 B
138 79 VS1
-0.69 29 123 B
105 78 VS6 1.03 27 84 B
138 85 DBH 1.91 29 124 B
107 132 03C 0.71 27 85 B
19 164 02C 0.74 28 125 B
114 39 VS2
-0.67 27 86 B
35 4
DBC 2.21 28 126 B
120 47 03C 0.76 27 87 B
40 121 VS4 1.08 28 127 B
128 73 VS1 0.26 27 88 B
41 14 VS4 0.1 28 128 B
128 113 02C
-0.84 27 89 B
44 27 VS4
-0.66 28 129 B
130 65 VS7 1.09 27 90 B
44 27 VS4 1.14 28 130 B
131 64 VS7 1.05 27 91 B
45 6
02C
-1.03 28 131 B
135 82 VS7 0.94 27 92 B
69 150 VS3
-0.55 28 132 B
44 45 VS4 1.1 26 93 B
76 21 VS4 1.08 28 133 B
46 39 VS4 0.93 26 94 B
79 24 VS4 0.94 28 134 B
47 14 VS4
-0.04 26 95 B
81 52 VS3 0.79 28 135 B
49 74 DBH
-1.52 26 96 B
98 139 VS4 0.21 28 136 B
49 124 VS4
-0.64 26 97 B
103 64 VS2 0.78 28 137 B
67 138 03C 0.78 26 98 B
106 31 VS4 1
28 138 B
82 43 VS5
-0.88 26 99 B
107 116 VS2 0.8 28 139 B
98 135 VS4 1.02 26 100 B
108 51 VS2
-0.63 28 140 B
100 125 VS4 1.12 26 101 B
110 55 VS2
-0.88 28 141 B
105 78 VS6
-0.68 26 102 B
110 131 03C 0.82 28 142 B
107 42 VS4 0.21 26 103 B
114 37 DBH 1.41 28 143 B
107 96 VS2 0.82 26 104 B
118 89 VS2 0.92 28 144 B
108 37 03C
-0.36 26 105 B
135 94 DBC 1.73 28 145 B
112 47 VS2
-0.77 26 106 B
41 12 VS4 0.8 27 146 B
120 115 03C 0.78 26 107 B
44 21 VS4
-0.75 27 147 B
134 69 VS7 1.05 26 108 B
45 36 VS4 0.12 27 148 B
15 130 05C
-1.15 25 109 B
47 20 VS4
-0.79 27 149 B
22 133 VS4 0.99 25 110 B
47 108 06H 0.96 27 150 B
34 31 VS4 0.33 25 111 B
48 65 VS4
-0.57 27 151 B
37 122 VS4
-0.86 25 112 B
49 8
VS4 0.99 27 152 B
37 124 VS4 0.94 25 Page 0-2
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 153 B
37 160 VS4 0.98 25 193 B
99 132 VS2 0.74 24 154 B
39 120 VS4 0.99 25 194 B
100 27 VS4
-0.91 24 155 B
44 65 VS4 0
25 195 B
100 125 VS6 0.81 24 156 B
44 107 VS4 1.09 25 196 B
105 34 02C 0.07 24 157 B
45 42 VS4
-0.89 25 197 B
105 130 03C 0.78 24 158 B
45 122 VS4
-1.09 25 198 B
107 36 VS2 0.76 24 159 B
47 98 VS4 0.96 25 199 B
108 113 VS4 1.09 24 160 B
47 128 VS4
-0.7 25 200 B
109 40 VS4 0.05 24 161 B
67 128 VS3 1
25 201 B
109 126 04H 0.91 24 162 B
74 17 VS3
-0.69 25 202 B
110 79 VS2 0.09 24 163 B
74 17 VS4
-0.92 25 203 B
111 130 VS4 0.99 24 164 B
77 34 VS3 0.87 25 204 B
116 115 VS4 0.89 24 165 B
96 137 VS4 1.14 25 205 B
119 42 04C
-0.67 24 166 B
102 85 VS6
-0.78 25 206 B
120 105 VS2
-0.75 24 167 B
105 54 VS6
-0.73 25 207 B
127 106 07C
-0.27 24 168 B
107 116 VS2
-0.79 25 208 B
128 101 05C 0.72 24 169 B
107 116 VS2
-0.02 25 209 B
130 91 DBC 1.56 24 170 B
108 33 08H 0.75 25 210 B
134 101 VS7 0.98 24 171 B
108 113 VS4
-0.78 25 211 B
138 79 VS2 0.82 24 172 B
109 104 VS2 0.98 25 212 B
36 45 VS4
-0.69 23 173 B
120 113 VS2
-0.92 25 213 B
37 124 VS4
-0.8 23 174 B
134 99 VS6 0.96 25 214 B
37 128 VS4 0.93 23 175 B
38 49 VS4 0.93 24 215 B
37 148 VS4
-0.6 23 176 B
44 31 VS4 0.3 24 216 B
37 156 VS4 0.83 23 177 B
44 47 VS4
-0.59 24 217 B
38 131 VS4 0.92 23 178 B
44 47 VS4 0.22 24 218 B
38 161 02H 0.9 23 179 B
45 32 VS4
-0.77 24 219 B
39 12 VS4
-0.52 23 180 B
46 23 VS4 0.98 24 220 B
39 134 VS4
-0.84 23 181 B
47 12 VS4 1.09 24 221 B
43 6
02C
-0.13 23 182 B
47 14 VS4 0.75 24 222 B
45 32 VS4 0.26 23 183 B
47 108 VS4 0.94 24 223 B
45 48 VS4 0.12 23 184 B
63 82 VS4 1.2 24 224 B
46 7
01C
-0.31 23 185 B
67 150 VS3 1.15 24 225 B
46 35 VS4
-0.61 23 186 B
68 113 04H 0.94 24 226 B
47 46 VS4
-0.62 23 187 B
69 144 VS5
-0.87 24 227 B
47 46 VS4 0.12 23 188 B
72 25 VS3
-0.56 24 228 B
47 108 VS4
-0.84 23 189 B
72 41 06C 0.75 24 229 B
48 13 VS4
-0.68 23 190 B
82 43 VS5 0.28 24 230 B
49 10 01C 0.84 23 191 B
97 28 03C 0.69 24 231 B
50 157 01H
-0.93 23 192 B
98 41 VS4 0.93 24 232 B
51 156 VS5
-0.79 23 Page D-3
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 233 B
59 48 03C 0.86 23 273 B
11 164 02C
-1.07 22 234 B
60 41 02H
-0.07 23 274 B
11 164 04C 0.66 22 235 B
63 82 VS5 1.12 23 275 B
28 39 VS4 1.09 22 236 B
68 151 VS3
-0.3 23 276 B
35 36 VS4 0.79 22 237 B
76 15 DBH 1.77 23 277 B
37 128 VS4
-0.76 22 238 B
81 22 VS4 1
23 278 B
41 12 05C
-0.02 22 239 B
82 43 VS4 0.9 23 279 B
41 12 VS4 0.02 22 240 B
84 19 07H
-1.01 23 280 B
43 48 05C 0.72 22 241 B
95 142 VS4 1.19 23 281 B
44 65 VS4 0.9 22 242 B
96 95 VS2
-0.73 23 282 B
45 6
02C
-0.25 22 243 B
96 141 VS4 0.8 23 283 B
45 32 VS4 1.14 22 244 B
98 135 VS4
-0.7 23 284 B
48 13 VS4 0.96 22 245 B
105 80 VS2
-0.11 23 285 B
69 34 DBC 1.66 22 246 B
105 134 02C 0.77 23 286 B
69 52 VS3 0
22 247 B
106 63 VS2 0
23 287 B
69 52 VS4
-0.61 22 248 B
106 77 VS2 1.19 23 288 B
70 153 03C
-0.07 22 249 B
107 46 VS6
-0.75 23 289 B
71 36 VS4 0.91 22 250 B
107 78 VS2 0.9 23 290 B
72 17 DBH 1.54 22 251 B
108 47 VS2
-0.51 23 291 B
72 131 DBH 1.58 22 252 B
108 133 02C 0
23 292 B
72 149 VS3 1
22 253 B
109 34 04C
-0.02 23 293 B
76 29 VS4 0.13 22 254 B
109 34 VS4
-0.63 23 294 B
76 35 DBH 1.72 22 255 B
109 62 07C 0.7 23 295 B
77 104 05C 0.78 22 256 B
109 132 04C
-0.13 23 296 B
77 150 VS4 1.2 22 257 B
112 47 VS4 1
23 297 B
82 43 VS3 0.92 22 258 B
112 79 VS2 0.65 23 298 B
82 145 VS3
-0.87 22 259 B
114 37 VS2
-0.69 23 299 B
87 146 VS4
-0.82 22 260 B
117 40 03C
-1.08 23 300 B
95 106 04C
-0.96 22 261 B
119 46 02C 0.74 23 301 B
101 30 03C
-1.03 22 262 B
125 104 07C
-0.25 23 302 B
103 136 VS4 1.03 22 263 B
129 56 01H 0.92 23 303 B
104 31 VS4 0.73 22 264 B
129 102 08C
-0.98 23 304 B
105 58 VS2
-0.84 22 265 B
132 61 02H
-0.88 23 305 B
106 39 03C 0.78 22 266 B
133 104 VS7 1
23 306 B
106 113 VS2
-0.13 22 267 B
135 82 VS7
-0.83 23 307 B
109 112 07H 0.89 22 268 B
136 91 DBC 1.85 23 308 B
109 132 05C 0.83 22 269 B
137 90 VS7
-0.88 23 309 B
113 130 VS4
-0.74 22 270 B
138 77 VS4 0.78 23 310 B
117 40 02C
-1.08 22 271 B
3 42 03C 0.75 22 311 B
125 112 02C 0.75 22 272 B
6 165 02C
-0.99 22 312 B
126 95 VS4
-0.71 22 Page 0-4
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 313 B
128 55 01C
-0.23 22 353 B
83 28 VS6
-0.83 21 314 B
131 96 04C 0.76 22 354 B
88 95 03C 0.76 21 315 B
131 102 06C
-1.11 22 355 B
91 124 04C 0.73 21 316 B
132 97 VS7 0.97 22 356 B
96 139 03C
-0.98 21 317 B
132 101 06C 0.83 22 357 B
98 139 VS4 1
21 318 B
135 68 VS7 0.97 22 358 B
99 50 05H 0.47 21 319 B
137 90 VS7 0.88 22 359 B
99 136 04C 0.79 21 320 B
138 79 VS6
-0.82 22 360 B
100 109 VS2
-0.67 21 321 B
138 81 VS4
-0.8 22 361 B
101 30 04C 0.79 21 322 B
138 87 VS1
-0.76 22 362 B
101 32 VS2 0.72 21 323 B
13 62 05C
-1.09 21 363 B
102 33 03C
-0.94 21 324 B
22 163 02C 0.82 21 364 B
102 137 VS4 1.02 21 325 B
34 31 VS4 0.85 21 365 B
103 94 VS2
-0.85 21 326 B
36 5
03C 0.61 21 366 B
103 126 VS2 0.19 21 327 B
37 10 03C
-0.98 21 367 B
104 95 VS2 0.87 21 328 B
38 145 VS4 1.09 21 368 B
106 31 03C 0.83 21 329 B
39 116 VS4
-0.79 21 369 B
108 59 VS2
-0.87 21 330 B
41 32 VS4 0
21 370 B
108 59 VS2 0.96 21 331 B
42 57 VS4 0.21 21 371 B
108 115 07C 0.78 21 332 B
44 31 DBC 1.3 21 372 B
108 131 02C 0.71 21 333 B
44 63 VS4 1.08 21 373 B
109 52 VS2
-0.87 21 334 B
45 48 VS4 0.84 21 374 B
110 97 08H 1.64 21 335 B
46 39 VS4 0.15 21 375 B
113 40 03C
-0.59 21 336 B
47 96 VS4 0.88 21 376 B
114 37 VS4
-0.65 21 337 B
47 108 VS4 0.05 21 377 B
114 127 03C 0.75 21 338 B
56 129 03C 0.86 21 378 B
116 81 VS7
-0.84 21 339 B
63 128 06C 0.79 21 379 B
116 111 04C
-1.08 21 340 B
65 62 04H
-1.19 21 380 B
117 112 04H 1.08 21 341 B
65 110 03H 0.93 21 381 B
123 116 05C
-1.02 21 342 B
66 21 06H 0.47 21 382 B
123 118 VS7
-0.92 21 343 B
69 132 04H 0.94 21 383 B
124 95 VS4 1
21 344 B
69 134 VS4 1.14 21 384 B
125 116 02H 0.91 21 345 B
69 140 VS5
-0.87 21 385 B
126 91 VS2 0
21 346 B
69 150 VS3 1.12 21 386 B
129 84 06H 0.9 21 347 B
70 141 VS3
-0.77 21 387 B
133 102 07C
-0.98 21 348 B
76 29 VS3 0.07 21 388 B
135 76 08C
-1.01 21 349 B
76 121 04C 0.77 21 389 B
137 92 VS7
-0.63 21 350 B
78 57 03C 0.82 21 390 B
138 91 DBH 1.9 21 351 B
80 95 04H 0.91 21 391 B
29 120 03H 1.05 20 352 B
82 41 VS3 1.11 21 392 B
40 121 VS4
-0.77 20 Page 0-5
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 393 B
41 8
04C 0.82 20 433 B
112 43 VS2
-0.75 20 394 B
41 54 VS4
-0.83 20 434 B
118 123 04C
-1.01 20 395 B
42 27 VS4
-0.66 20 435 B
119 42 VS7
-0.73 20 396 B
42 51 VS4 1.07 20 436 B
121 118 02C 0.71 20 397 B
44 37 VS4 0.98 20 437 B
124 117 04C 0.71 20 398 B
44 127 02C 0.71 20 438 B
124 117 VS7
-0.13 20 399 B
45 34 VS4
-0.78 20 439 B
125 94 VS2
-0.68 20 400 B
45 140 DBH
-1.15 20 440 B
125 114 03C 0.74 20 401 B
48 9
VS4 1.01 20 441 B
126 115 02C 0.77 20 402 B
56 85 03C 0.77 20 442 B
127 54 01H
-0.82 20 403 B
67 104 06C
-0.24 20 443 B
127 92 08C
-0.29 20 404 B
67 136 DBH
-1.77 20 444 B
129 106 08C 0.76 20 405 B
69 52 VS4
-0.04 20 445 B
130 55 01H 0.9 20 406 B
71 20 VS5 0.88 20 446 B
133 100 VS7
-0.09 20 407 B
71 36 VS3 0.9 20 447 B
134 65 02H 0.85 20 408 B
71 144 VS3 0.97 20 448 B
136 97 03C 0.74 20 409 B
75 42 04C 0.72 20 449 B
138 77 02H 0.99 20 410 B
76 29 VS3 0.82 20 450 B
138 79 VS4 0.93 20 411 B
76 51 VS3 0.82 20 451 B
138 79 VS6 0.82 20 412 B
77 104 05H 0.98 20 452 B
138 87 VS4
-0.57 20 413 B
80 145 VS5 0.77 20 453 B
138 89 VS4
-0.62 20 414 B
82 43 VS5
-0.11 20 454 B
2 165 01C 0.73 19 415 B
82 145 VS3 0.91 20 455 B
3 36 03C 0.82 19 416 B
92 83 05H 0.95 20 456 B
9 46 DBH 0.53 19 417 B
95 36 VS4 1.04 20 457 B
16 155 03H
-0.17 19 418 B
95 134 VS2 1.01 20 458 B
18 137 VS4 1.19 19 419 B
98 81 DBH 0.02 20 459 B
32 5
02C 0.73 19 420 B
98 135 VS2 0.15 20 460 B
33 158 02C 0.74 19 421 B
99 132 VS2
-0.79 20 461 B
35 42 05H 0.95 19 422 B
100 29 03C 0.72 20 462 B
36 157 02C
-0.88 19 423 B
102 31 02C
-0.94 20 463 B
37 12 VS4
-0.62 19 424 B
102 35 03C 0.78 20 464 B
37 160 VS4
-0.33 19 425 B
103 136 VS4
-0.68 20 465 B
38 53 VS4 0.1 19 426 B
105 30 02C 0.7 20 466 B
38 107 02C 0.76 19 427 B
106 39 VS2
-0.63 20 467 B
40 123 VS4 0.97 19 428 B
106 57 VS2 1.16 20 468 B
40 125 02C
-1.09 19 429 B
107 42 VS6
-0.95 20 469 B
41 132 VS4 0.87 19 430 B
107 58 DBH 1.81 20 470 B
43 126 04C
-0.89 19 431 B
109 40 VS2
-1.05 20 471 B
44 31 02C 0.62 19 432 B
109 114 VS2 0.04 20 472 B
44 57 VS4
-0.6 19 Page D-6
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 473 B
44 107 VS4
-0.66 19 513 B
98 81 VS4
-0.71 19 474 B
45 42 VS4 1.03 19 514 B
98 93 03C 0.69 19 475 B
46 23 VS4
-0.82 19 515 B
101 54 02C 0.76 19 476 B
47 22 VS4
-0.72 19 516 B
101 104 DBH 1.83 19 477 B
47 70 VS4
-0.67 19 517 B
104 31 02C
-0.27 19 478 B
53 80 03C 0.81 19 518 B
105 38 03C 0.78 19 479 B
55 64 02C 0.85 19 519 B
105 58 VS6 0.82 19 480 B
59 28 DBH 1.72 19 520 B
105 130 VS2 0.04 19 481 B
64 51 VS5 0
19 521 B
106 31 VS4 0.36 19 482 B
67 58 03C 0.85 19 522 B
107 130 03H 0.96 19 483 B
67 150 VS3
-0.67 19 523 B
109 40 VS2 0.82 19 484 B
68 41 04H 0.95 19 524 B
109 112 07C 0.73 19 485 B
69 136 VS5
-0.79 19 525 B
109 112 VS2
-0.97 19 486 B
69 144 VS3
-0.64 19 526 B
111 50 VS2 0.81 19 487 B
69 150 VS5 0.91 19 527 B
113 36 02C 0.81 19 488 B
70 153 VS4 1.19 19 528 B
113 36 VS6
-0.93 19 489 B
71 36 VS3 0.09 19 529 B
113 110 04C 0.79 19 490 B
71 136 06C
-0.95 19 530 B
116 43 VS4 0.89 19 491 B
72 19 VS3 0.13 19 531 B
116 45 VS4 0.95 19 492 B
73 104 06C
-0.99 19 532 B
117 40 04C
-0.18 19 493 B
73 132 06H 0.93 19 533 B
117 90 08C 0.86 19 494 B
74 43 VS4
-0.69 19 534 B
119 42 03C 0
19 495 B
75 104 03H 0.93 19 535 B
119 44 02H 0.84 19 496 B
78 23 DBH
-1.48 19 536 B
119 72 DBC 1.1 19 497 B
78 61 VS3
-0.94 19 537 B
119 88 08C 0.85 19 498 B
84 81 02C 0.83 19 538 B
120 43 01C
-0.92 19 499 B
85 36 VS6
-0.74 19 539 B
123 52 02C 0.76 19 500 B
85 142 03C
-0.85 19 540 B
125 104 07H 0.94 19 501 B
87 20 VS4
-0.88 19 541 B
125 116 VS4
-0.62 19 502 B
87 88 04C
-0.92 19 542 B
126 103 VS4 0.97 19 503 B
91 64 03C
-0.94 19 543 B
127 112 02C 0.73 19 504 B
91 144 VS4
-0.79 19 544 B
130 55 02C 0.76 19 505 B
91 144 VS4 1.03 19 545 B
132 81 05H 0.97 19 506 B
92 69 04C 0.58 19 546 B
134 63 DBH
-1.51 19 507 B
93 30 VS4
-0.84 19 547 B
135 76 VS7
-0.83 19 508 B
95 24 VS4
-0.7 19 548 B
135 98 VS6
-0.72 19 509 B
95 84 07C 0.82 19 549 B
136 97 07C 0.58 19 510 B
96 95 VS2 0.94 19 550 B
137 92 07C 0.07 19 511 B
97 60 VS2 0.88 19 551 B
137 92 08C
-1.01 19 512 B
98 27 04C
-1.03 19 552 B
1 164 02C
-0.87 18 Page 0-7
ATIACHMENT 1 to AREVA-17-Q2174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 1 SO-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 553 B
11 2
02H 0.87 18 593 B
84 77 05C
-1.01 18 554 B
13 4
02H
-0.79 18 594 B
90 55 VS2 1.04 18 555 B
15 154 04H 0.99 18 595 B
91 32 02C
-0.92 18 556 B
21 58 02C 0.82 18 596 B
95 102 05H 0.86 18 557 B
27 64 DBH
-1.8 18 597 B
96 29 VS4 0.9 18 558 B
34 133 03C 0.68 18 598 B
98 49 VS2
-0.44 18 559 B
37 6
03H 0.89 18 599 B
100 125 VS2 0.89 18 560 B
37 160 02H 0.9 18 600 B
100 133 VS4
-0.7 18 561 B
38 49 VS4 0.39 18 601 B
102 51 07C 0.88 18 562 B
39 102 VS4
-0.55 18 602 B
102 99 07C 0.81 18 563 B
42 39 VS4 0.12 18 603 B
103 108 VS6
-0.67 18 564 B
43 132 VS4 0.91 18 604 B
103 122 03H 0.85 18 565 B
44 23 VS4 1.01 18 605 B
104 95 VS2 0.07 18 566 B
44 41 02C
-0.27 18 606 B
105 58 VS4
-0.61 18 567 B
44 45 04C 0.85 18 607 B
105 116 03H 0.9 18 568 B
45 36 VS4 1.04 18 608 B
105 130 VS2
-0.59 18 569 B
45 38 VS4 0.19 18 609 B
106 37 VS2
-0.5 18 570 B
45 126 02C 0.74 18 610 B
106 75 VS2 1.19 18 571 B
47 58 VS4 0.95 18 611 B
107 40 VS2 0.93 18 572 B
47 96 VS4
-0.73 18 612 B
107 120 DBC 1.81 18 573 B
48 13 VS4
-0.09 18 613 B
109 78 04C
-1.04 18 574 B
48 107 04C 0.77 18 614 B
110 97 VS2
-0.54 18 575 B
49 46 VS4
-0.74 18 615 B
111 66 07H 0.92 18 576 B
49 158 01C 0.04 18 616 B
112 43 VS2 1.05 18 577 B
51 64 02C 0.91 18 617 B
113 44 01H 0.98 18 578 B
51 134 03C
-1.03 18 618 B
113 70 07C
-0.04 18 579 B
53 8
01C 0.76 18 619 B
113 70 07C 0.74 18 580 B
61 28 DBC 1.52 18 620 B
118 87 VS2 1.09 18 581 B
63 136 03C 0.78 18 621 B
118 105 VS4
-0.46 18 582 B
66 149 06H 0.87 18 622 B
119 112 04C 0.78 18 583 B
67 62 03C 0.73 18 623 B
120 113 VS2 0.82 18 584 B
68 93 04C
-0.96 18 624 B
121 44 01H 0.85 18 585 B
68 143 06H 1.04 18 625 B
121 114 03C 0.65 18 586 B
71 20 DBC 1.57 18 626 B
124 49 02C
-1.01 18 587 B
71 20 DBH
-1.61 18 627 B
124 95 VS2 0.02 18 588 B
74 23 VS3
-1.03 18 628 B
126 83 VS1
-0.13 18 589 B
74 45 VS5
-0.94 18 629 B
129 64 VS7
-0.64 18 590 B
74 55 04C 0.83 18 630 B
129 110 02C 0.67 18 591 B
80 115 VS4
-0.71 18 631 B
131 82 08H
-0.77 18 592 B
83 28 VS6 0.73 18 632 B
134 69 04H 0.98 18 Page D-S
t ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 633 B
134 95 DBC 1.45 18 673 B
46 143 DBC 1.63 17 634 B
135 72 VS7
-0.88 18 674 B
47 22 VS4 1.13 17 635 B
135 76 08C 0.7 18 675 B
47 56 VS4
-0.69 17 636 B
135 80 07H
-0.88 18 676 B
48 111 04C 0.79 17 637 B
136 69 DBC 1.79 18 677 B
49 132 03C
-0.93 17 638 B
136 95 03C 0.76 18 678 B
50 7
DBH 1.75 17 639 B
136 97 08C
-1.14 18 679 B
52 107 02C 0.81 17 640 B
136 97 VS7 1
18 680 B
53 56 03H 0.88 17 641 B
1 160 04H 0.72 17 681 B
55 114 03C 0.86 17 642 B
2 141 03H
-0.91 17 682 B
55 120 04H
-0.95 17 643 B
13 140 02H 0.84 17 683 B
56 97 04C 0.82 17 644 B
21 8
03C
-0.95 17 684 B
57 26 06H 0.91 17 645 B
31 4
02C
-0.93 17 685 B
57 62 04H 0.88 17 646 B
32 13 03C 0.74 17 686 B
59 48 06H 1.03 17 647 B
33 12 VS4 1.07 17 687 B
59 118 03C
-0.92 17 648 B
34 161 02C 0.73 17 688 B
60 133 03C
-0.97 17 649 B
35 4
01C
-0.98 17 689 B
63 138 03C 0.71 17 650 B
35 64 05H 0.92 17 690 B
67 134 03C 0.76 17 651 B
37 6
02C
-0.18 17 691 B
68 109 02H 0.96 17 652 B
37 54 02H 0.94 17 692 B
69 120 03C 0.74 17 653 B
37 156 VS4
-0.81 17 693 B
69 128 03C 0.75 17 654 B
38 45 02C 0.09 17 694 B
70 153 VS4
-0.72 17 655 B
38 127 02C
-0.92 17 695 B
71 38 05H 0.98 17 656 B
39 8
03C
-1.06 17 696 B
71 144 DBC 1.56 17 657 B
40 5
02C
-1.03 17 697 B
72 55 VS3
-0.87 17 658 B
40 117 03C 0.69 17 698 B
72 63 02C 0.78 17 659 B
40 129 04C
-0.97 17 699 B
73 58 06C
-0.58 17 660 B
41 14 VS4 0.8 17 700 B
74 117 VS3
-0.94 17 661 B
41 122 VS4
-0.86 17 701 B
74 141 VS5
-0.86 17 662 B
41 128 04C
-1.01 17 702 B
75 36 VS3 0.8 17 663 B
44 19 VS4 0.19 17 703 B
75 58 02H
-0.77 17 664 B
44 29 VS4
-0.7 17 704 B
76 21 VS4
-0.82 17 665 B
44 59 VS4 0.93 17 705 B
76 25 06H 1
17 666 B
45 56 03H 0.86 17 706 B
76 59 VS3
-0.71 17 667 B
45 140 06C
-0.89 17 707 B
76 151 04C 0.69 17 668 B
45 140 VS4
-0.87 17 708 B
77 48 VS4 1.2 17 669 B
45 148 06C
-0.82 17 709 B
77 116 04H
-0.85 17 670 B
46 37 VS4 1.18 17 710 B
77 150 VS4
-0.69 17 671 B
46 129 VS4 0.98 17 711 B
78 47 02C 0.83 17 672 B
46 131 VS4
-0.84 17 712 B
80 97 VS3
-0.04 17 Page D-9
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 713 B
80 149 01H
-0.7 17 753 B
113 40 VS4
-0.82 17 714 B
81 60 03C 0.76 17 754 B
115 86 03H 0.86 17 715 B
81 112 02H 0.93 17 755 B
116 103 05C 0.8 17 716 B
82 143 VS4
-0.73 17 756 B
117 68 05H 0.99 17 717 B
85 78 05H 1.02 17 757 B
118 43 VS4 0.98 17 718 B
85 110 04C 0.74 17 758 B
118 43 VS6 0
17 719 B
86 51 03C 0.78 17 759 B
118 117 04C
-0.18 17 720 B
88 107 04C
-0.91 17 760 B
119 44 01C 0.74 17 721 B
89 92 04C 0.4 17 761 B
121 114 VS4
-0.81 17 722 B
90 65 03C 0.74 17 762 B
124 95 VS4
-0.81 17 723 B
91 58 03C 0.82 17 763 B
125 48 VS6 0.91 17 724 B
91 88 04H
-0.73 17 764 B
125 100 08C 0.8 17 725 B
93 112 VS6 0.73 17 765 B
126 61 VS1 0.92 17 726 B
95 36 VS4
-0.79 17 766 B
126 99 08C 0.75 17 727 B
95 70 VS6
-0.8 17 767 B
127 114 01H
-0.83 17 728 B
95 116 VS2
-1 17 768 B
128 53 01H
-0.11 17 729 B
95 140 03C
-1 17 769 B
131 102 05C 0.76 17 730 B
96 137 VS4
-0.13 17 770 B
132 97 VS2
-0.57 17 731 B
97 60 06C 0.69 17 771 B
133 74 03H 0.8 17 732 B
97 72 04H 0.96 17 772 B
134 63 07C 0.76 17 733 B
98 41 VS2 1.02 17 773 B
137 80 08H 0.94 17 734 B
100 29 VS6
-0.76 17 774 B
137 90 VS4 0.25 17 735 B
101 28 VS4
-0.7 17 775 B
137 90 VS6
-0.61 17 736 B
101 98 04C
-1.07 17 776 B
138 89 07C 0.72 17 737 B
103 62 03C 0.78 17 777 B
138 89 VS7
-0.88 17 738 B
103 130 VS2 0
17 778 B
1 150 01C
-0.61 16 739 B
104 95 VS2
-0.63 17 779 B
1 158 02C 0.72 16 740 B
105 30 VS4 0.25 17 780 B
3 6
02C 0.79 16 741 B
105 58 VS4 0.14 17 781 B
7 2
05H 0.9 16 742 B
105 90 VS2 0.96 17 782 B
7 140 04C 0.69 16 743 B
105 90 VS4 1.19 17 783 B
12 3
03C
-0.94 16 744 B
106 35 04H 0.93 17 784 B
13 6
03C 0.78 16 745 B
107 32 VS4
-0.59 17 785 B
15 164 02H 0.91 16 746 B
107 78 VS2
-0.88 17 786 B
30 115 02H 0.88 16 747 B
108 37 02C 0.76 17 787 B
31 14 05H
-0.94 16 748 B
109 130 03C 0.84 17 788 B
33 4
01C
-1.02 16 749 B
110 131 02C
-1.01 17 789 B
34 11 VS4 1.13 16 750 B
110 131 02C 0.77 17 790 B
35 52 05C 0.87 16 751 B
112 53 VS2
-0.85 17 791 B
35 52 DBC 1.42 16 752 B
113 36 VS2 0.93 17 792 B
36 41 03H
-0.79 16 Page 0-10
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube I nspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 793 B
36 51 VS4 0.93 16 833 B
63 70 04H 0.93 16 794 B
36 149 VS4
-0.74 16 834 B
63 110 03H
-0.09 16 795 B
37 48 02H
-0.81 16 835 B
63 136 VS5 1.03 16 796 B
37 54 04C 0.8 16 836 B
66 17 06H 0.9 16 797 B
38 9
03C
-1 16 837 B
66 39 VS5
-0.95 16 798 B
38 13 VS4 0.87 16 838 B
67 76 02H
-0.76 16 799 B
38 125 VS4
-0.82 16 839 B
67 128 06H 0.19 16 800 B
38 131 VS4
-0.84 16 840 B
67 148 DBH 1.68 16 801 B
39 102 VS4 0.88 16 841 B
68 21 VS5
-0.87 16 802 B
39 122 02C
-0.93 16 842 B
68 113 03H 0.86 16 803 B
39 122 VS4 0.81 16 843 B
69 28 06C 0.78 16 804 B
40 31 03H 0.93 16 844 B
69 52 VS5
-0.85 16 805 B
40 31 VS4 0.83 16 845 B
69 72 06C
-0.96 16 806 B
41 134 03C 0.76 16 846 B
69 110 03C 0.77 16 807 B
42 37 VS4
-0.02 16 847 B
69 134 VS3
-0.62 16 808 B
43 42 05C 0.8 16 848 B
70 129 06C
-0.94 16 809 B
43 134 03C
-1.03 16 849 B
70 147 VS3
-0.78 16 810 B
44 45 03C 0.78 16 850 B
71 52 03C 0.81 16 811 B
44 131 03C 0.71 16 851 B
71 102 05C 0.69 16 812 B
44 159 01H
-0.92 16 852 B
72 23 VS3 0.75 16 813 B
45 48 VS4
-0.92 16 853 B
72 61 02C 0.74 16 814 B
45 118 06H 0
16 854 B
74 23 V54
-0.71 16 815 B
45 130 VS4 1.11 16 855 B
74 119 04H 0.89 16 816 B
45 132 VS4 1.06 16 856 B
75 16 06H 0.96 16 817 B
45 148 VS4 1.06 16 857 B
75 24 VS3 0.14 16 818 B
46 103 04C 0.78 16 858 B
75 60 03C 0.8 16 819 B
47 12 VS4
-0.67 16 859 B
76 21 VS3 0.96 16 820 B
47 116 04C
-0.97 16 860 B
76 59 05H 0.95 16 821 B
48 99 03C 0.73 16 861 B
77 86 02C 0.8 16 822 B
48 129 03C
-0.22 16 862 B
78 91 07H 1.47 16 823 B
50 9
01C
-0.95 16 863 B
78 109 03H 0.95 16 824 B
50 63 DBH
-1.46 16 864 B
80 49 VS4
-0.77 16 825 B
50 127 03C
-0.92 16 865 B
81 24 VS3
-0.74 16 826 B
51 72 VS3
-0.85 16 866 B
81 148 04C 0.75 16 827 B
53 132 02C 0.95 16 867 B
81 148 VS4 1.06 16 828 B
54 17 VS3 0.97 16 868 B
82 145 VS4
-0.91 16 829 B
57 16 06H
-0.09 16 869 B
83 106 03H 0.95 16 830 B
57 90 03C 0.64 16 870 B
84 145 03C
-0.93 16 831 B
59 120 04H
-0.68 16 871 B
86 79 04H 1.02 16 832 B
59 122 03C
-0.25 16 872 B
86 89 03C 0.68 16 Page 0-11
ATIACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 873 B
87 82 03H 0.94 16 913 B
113 40 04H
-0.02 16 874 B
87 146 VS4 1.15 16 914 B
113 42 VS4 1.04 16 875 B
89 60 04C
-0.94 16 915 B
114 37 04C 0.85 16 876 B
89 78 07C 0.84 16 916 B
115 38 VS4
-0.63 16 877 B
89 82 07C 0.73 16 917 B
115 84 03H
-0.72 16 878 B
89 84 03H 0.9 16 918 B
115 124 05C
-0.95 16 879 B
91 94 06C
-0.83 16 919 B
116 47 VS4 0.87 16 880 B
92 57 04H 0.9 16 920 B
116 77 VS2 0.63 16 881 B
93 132 04H 0.87 16 921 B
116 81 07C
-0.92 16 882 B
94 93 04C
-0.2 16 922 B
116 117 03C
-0.26 16 883 B
94 115 04C
-0.98 16 923 B
116 125 04C 0.68 16 884 B
95 126 04H 0.89 16 924 B
117 40 02C 0.85 16 885 B
95 136 03C
-0.29 16 925 B
117 48 03C
-1.01 16 886 B
96 95 VS2 0.22 16 926 B
119 42 02H 0.96 16 887 B
96 137 04C
-0.22 16 927 B
119 112 03C 0.84 16 888 B
97 26 VS4
-0.54 16 928 B
122 71 05H 0.94 16 889 B
97 84 07C
-0.98 16 929 B
123 72 VS7 0.68 16 890 B
98 79 03C 0.83 16 930 B
125 48 VS4 0.89 16 891 B
98 139 03C
-0.97 16 931 B
125 116 03H 0.83 16 892 B
100 121 06C 0.8 16 932 B
127 102 07C
-0.29 16 893 B
101 136 03H 0.87 16 933 B
128 73 VS4 1.08 16 894 B
102 41 06H 0.97 16 934 B
129 104 07C
-0.25 16 895 B
103 36 07C 0.94 16 935 B
130 65 VS4 0.67 16 896 B
103 48 VS4
-0.76 16 936 B
131 78 VS6
-0.76 16 897 B
103 126 VS4
-0.56 16 937 B
131 104 DBC 1.74 16 898 B
103 128 04C 0.81 16 938 B
133 102 VS7
-0.78 16 899 B
104 79 VS6
-0.82 16 939 B
134 97 VS6 0.93 16 900 B
105 76 VS2 1.11 16 940 B
136 87 08C
-1.07 16 901 B
105 90 03C 0.38 16 941 B
137 74 06H 0.82 16 902 B
107 52 07C 0.79 16 942 B
137 90 DBC 1.72 16 903 B
107 52 VS6
-0.57 16 943 B
137 90 VS4 0.88 16 904 B
107 82 VS4 0.16 16 944 B
2 143 02C 0.8 15 905 B
108 37 04C
-1.03 16 945 B
8 3
03C
-0.19 15 906 B
108 43 VS4
-0.89 16 946 B
9 140 03C 0.77 15 907 B
108 45 07C 0.83 16 947 B
10 133 02C 0.82 15 908 B
108 131 03C 0.02 16 948 B
22 11 02C 0.79 15 909 B
109 52 VS6 0.96 16 949 B
24 7
DBH 1.66 15 910 B
110 131 03C
-1.06 16 950 B
27 64 05H 0
15 911 B
112 43 VS4
-0.7 16 951 B
30 7
03C 0.7 15 912 B
112 53 VS2 0.93 16 952 B
30 9
02C 0.75 15 Page 0-12
t ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 953 B
30 45 VS4 1.09 15 993 B
56 145 04C
-1 15 954 B
31 4
03C
-0.97 15 994 B
57 80 03C 0.77 15 955 B
31 50 03C 0.78 15 995 B
57 148 04C 0.82 15 956 B
32 5
04H 0.92 15 996 B
58 27 05H 0.89 15 957 B
32 157 DBH 1.88 15 997 B
59 66 02H
-0.79 15 958 B
33 160 02C
-0.96 15 998 B
61 142 03C 0.81 15 959 B
33 162 02C
-1.04 15 999 B
62 17 VS4
-0.63 15 960 B
34 11 DBC
-1.16 15 1000 B
62 17 VS5 0.9 15 961 B
34 103 04H
-0.83 15 1001 B
62 23 VS5 0.94 15 962 B
34 113 01C 0.75 15 1002 B
64 147 DBH 1.83 15 963 B
36 113 03C 0.71 15 1003 B
66 35 06C 0.75 15 964 B
37 6
01H
-0.75 15 1004 B
67 36 06H 0.93 15 965 B
37 6
02C
-0.96 15 1005 B
69 16 VS3
-0.58 15 966 B
38 39 02H 0.87 15 1006 B
69 28 06H
-0.85 15 967 B
38 127 04C 0.07 15 1007 B
69 28 06H
-0.02 15 968 B
38 133 VS4
-0.68 15 1008 B
69 52 VS5 0.9 15 969 B
39 50 VS4
-0.57 15 1009 B
69 106 06H
-0.75 15 970 B
40 33 VS4 0.23 15 1010 B
69 120 03C
-0.02 15 971 B
40 51 01H 0.85 15 1011 B
69 136 VS5 0.97 15 972 B
40 143 05H 0.91 15 1012 B
71 14 02H
-0.8 15 973 B
41 48 03H 0.9 15 1013 B
71 36 VS5
-0.7 15 974 B
41 56 02H 0.95 15 1014 B
71 86 02C
-0.95 15 975 B
41 132 04C
-0.04 15 1015 B
71 146 06H 0.13 15 976 B
42 133 02H
-0.84 15 1016 B
72 59 04C 0.78 15 977 B
43 6
02C
-0.9 15 1017 B
72 85 05C 0.76 15 978 B
44 53 VS4
-0.64 15 1018 B
74 17 VS3 0.97 15 979 B
45 128 03H
-0.81 15 1019 B
74 43 VS3
-0.91 15 980 B
46 25 VS4
-0.52 15 1020 B
75 24 DBC
-1.59 15 981 B
46 69 DBH
-1.59 15 1021 B
75 102 04H 0.97 15 982 B
47 102 VS4
-0.86 15 1022 B
77 150 DBH 1.2 15 983 B
47 132 VS4 1
15 1023 B
78 35 DBH
-1.37 15 984 B
47 140 VS4 1.04 15 1024 B
80 49 VS3
-0.82 15 985 B
49 26 03H 1.01 15 1025 B
80 95 03H 1.09 15 986 B
49 106 VS4 0.02 15 1026 B
81 126 07C 0.79 15 987 B
50 159 01C 0.83 15 1027 B
82 43 VS4
-0.09 15 988 B
51 58 03H 0.92 15 1028 B
83 64 03C 0.82 15 989 B
54 117 02C 0.81 15 1029 B
84 81 VS5
-0.95 15 990 B
55 32 VS3
-0.7 15 1030 B
84 93 02C
-1.02 15 991 B
55 60 04H 0.93 15 1031 B
84 107 02H
-0.77 15 992 B
55 78 01C 0.8 15 1032 B
85 144 03C
-0.98 15 Page 0-13
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1033 B
87 84 02C 0.76 15 1073 B
120 45 02C 0.78 15 1034 B
88 29 06H 1
15 1074 B
120 103 07H 0.89 15 1035 B
89 44 VS6
-0.9 15 1075 B
122 71 VS2
-0.7 15 1036 B
89 100 03H 0.85 15 1076 B
124 51 VS4 0.56 15 1037 B
90 95 04C 0.8 15 1077 B
124 57 VS7
-0.82 15 1038 B
90 97 04C 0.8 15 1078 B
125 94 VS2
-0.15 15 1039 B
91 38 03H
-0.78 15 1079 B
126 109 04H 0.95 15 1040 B
92 49 05H 0.86 15 1080 B
132 61 01H 0.99 15 1041 B
92 97 04C 0.8 15 1081 B
134 97 VS6
-0.81 15 1042 B
94 37 VS2
-0.59 15 1082 B
134 99 VS6
-0.74 15 1043 B
94 101 06H
-0.77 15 1083 B
136 97 08C 0
15 1044 B
95 24 VS4
-0.07 15 1084 B
138 81 08C
-1.14 15 1045 B
95 134 VS2 0.13 15 1085 B
138 85 08H 0.8 15 1046 B
96 71 04H
-0.88 15 1086 B
1 36 03C 0.79 14 1047 B
97 40 VS2
-0.85 15 1087 B
3 6
02C
-0.97 14 1048 B
98 71 VS2 1.04 15 1088 B
5 138 02H
-0.98 14 1049 B
99 32 02C 0.7 15 1089 B
17 36 04H
-0.82 14 1050 B
99 132 VS4 1.09 15 1090 B
18 5
03C
-0.21 14 1051 B
101 30 03C 0.85 15 1091 B
21 4
03C 0.79 14 1052 B
103 36 07H 0.99 15 1092 B
21 64 DBC
-1.81 14 1053 B
103 132 VS2 0
15 1093 B
30 51 02H 0.82 14 1054 B
104 59 VS4 1
15 1094 B
32 45 02H 0.83 14 1055 B
104 59 VS6
-0.84 15 1095 B
32 45 03H 0.9 14 1056 B
105 90 07C 0.9 15 1096 B
32 151 V54 1.1 14 1057 B
106 51 07C 0.75 15 1097 B
33 32 04H 1
14 1058 B
107 44 06C
-0.24 15 1098 B
33 52 03C 0.76 14 1059 B
108 51 VS2 0.99 15 1099 B
34 117 04C 0.72 14 1060 B
109 96 VS2
-0.88 15 1100 B
35 6
05C
-0.2 14 1061 B
109 114 VS2
-0.8 15 1101 B
35 46 03H
-0.83 14 1062 B
110 37 04C
-0.98 15 1102 B
35 46 03H 0.86 14 1063 B
111 130 02H 0.17 15 1103 B
36 119 03C
-0.99 14 1064 B
112 59 VS2 0.89 15 1104 B
38 5
02C
-0.95 14 1065 B
112 71 VS2
-0.73 15 1105 B
38 53 VS4 0.81 14 1066 B
113 36 VS2
-0.62 15 1106 B
38 145 VS4
-0.75 14 1067 B
114 39 02C 0.79 15 1107 B
39 10 03C 0.69 14 1068 B
115 38 02C 0.78 15 1108 B
39 22 DBC 1.52 14 1069 B
116 45 06H 0.93 15 1109 B
39 52 03H
-0.84 14 1070 B
118 73 VS7
-0.81 15 1110 B
39 160 02H 0.86 14 1071 B
118 89 VS4 0.77 15 1111 B
40 39 04H
-0.82 14 1072 B
119 104 VS1
-0.64 15 1112 B
41 6
01C
-0.93 14 Page 0-14
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1113 B
41 28 05H 0.9 14 1153 B
74 23 DBC 1.46 14 1114 B
42 51 VS4
-0.11 14 1154 B
74 119 03H 0.92 14 1115 B
44 27 DBC
-1.4 14 1155 B
74 127 DBH
-1.47 14 1116 B
44 101 04C 0.73 14 1156 B
75 16 02H 0.9 14 1117 B
44 131 VS4 0.9 14 1157 B
76 127 DBH
-1.62 14 1118 B
45 34 VS4 1.08 14 1158 B
77 34 VS3 0.14 14 1119 B
46 7
06C 1.09 14 1159 B
78 79 VS4 1.09 14 1120 B
46 37 VS4
-0.72 14 1160 B
78 87 03C
-0.94 14 1121 B
46 125 02C
-0.97 14 1161 B
79 24 VS3
-0.73 14 1122 B
47 46 VS4 0.98 14 1162 B
79 24 VS3 1.12 14 1123 B
48 7
01H 0.89 14 1163 B
79 52 02C
-0.25 14 1124 B
48 67 VS4 0.28 14 1164 B
79 86 03H 0.88 14 1125 B
48 123 VS4 1.02 14 1165 B
79 128 03C 0.76 14 1126 B
48 139 03H 0.97 14 1166 B
80 95 02H 0.98 14 1127 B
49 34 VS4
-0.94 14 1167 B
80 145 VS5
-0.92 14 1128 B
52 25 02H 0.9 14 1168 B
81 24 VS3 1.09 14 1129 B
53 128 03C 0.71 14 1169 B
81 92 02C
-0.93 14 1130 B
54 71 02H 0.99 14 1170 B
82 21 VS5
-0.81 14 1131 B
54 143 VS3
-0.74 14 1171 B
82 137 DBH 1.71 14 1132 B
55 126 03C 0.04 14 1172 B
83 54 04H 0.96 14 1133 B
56 85 02C
-0.91 14 1173 B
84 125 04H
-0.81 14 1134 B
58 63 04H 0.73 14 1174 B
85 20 VS4 1.13 14 1135 B
61 12 06H
-0.13 14 1175 B
85 36 04H
-0.82 14 1136 B
61 62 03H
-0.7 14 1176 B
86 111 04C
-0.93 14 1137 B
61 68 02H
-0.78 14 1177 B
87 38 VS6
-0.86 14 1138 B
61 102 05C
-0.2 14 1178 B
91 54 02C 0.86 14 1139 B
64 37 06H
-0.07 14 1179 B
91 86 VS6 0.85 14 1140 B
64 51 VS5 0.85 14 1180 B
92 31 VS2
-0.8 14 1141 B
66 51 06H 0.94 14 1181 B
93 62 02C 0.78 14 1142 B
66 153 VS3 0.58 14 1182 B
93 62 03C 0.78 14 1143 B
67 56 03C 0.76 14 1183 B
94 129 04H 0.92 14 1144 B
67 148 VS3 0.99 14 1184 B
94 131 03C
-0.9 14 1145 B
68 85 02C
-0.92 14 1185 B
95 24 VS4 0.82 14 1146 B
69 124 03C
-0.95 14 1186 B
95 104 03C 0.02 14 1147 B
70 51 03C 0.78 14 1187 B
96 57 02H 0.9 14 1148 B
70 75 03H 0
14 1188 B
97 140 VS4
-0.81 14 1149 B
71 86 VS5
-0.87 14 1189 B
98 139 04H 0
14 1150 B
71 132 VS5 0.99 14 1190 B
101 28 VS4 0.02 14 1151 B
72 47 03C
-1.03 14 1191 B
102 127 VS4 0.93 14 1152 B
72 57 03C
-0.94 14 1192 B
102 137 VS4
-0.75 14 Page 0-15
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1193 B
103 100 07C 0.81 14 1233 B
133 104 DBC 1.63 14 1194 B
105 32 VS4 1.19 14 1234 B
135 96 04C 0.78 14 1195 B
105 78 VS2 1.06 14 1235 B
138 79 03H 0.94 14 1196 B
105 96 04C
-1.05 14 1236 B
138 89 VS6 0.79 14 1197 B
105 110 DBH 0.61 14 1237 B
1 160 03C
-0.11 13 1198 B
106 35 02C
-0.16 14 1238 B
13 2
04C
-0.13 13 1199 B
106 35 03C 0.85 14 1239 B
24 53 02C 0.95 13 1200 B
106 35 03H 0.9 14 1240 B
25 40 04H
-0.79 13 1201 B
106 129 04C 0.8 14 1241 B
30 57 03C
-0.94 13 1202 B
107 46 VS6 0.91 14 1242 B
33 54 03C
-1 13 1203 B
107 132 04C 0.78 14 1243 B
33 162 03C 0.76 13 1204 B
108 33 DBH
-1.26 14 1244 B
34 43 03H 0.95 13 1205 B
108 49 05H 0.95 14 1245 B
35 46 03C 0.76 13 1206 B
109 64 08C
-0.87 14 1246 B
36 149 VS4 0.27 13 1207 B
111 56 08H 0.16 14 1247 B
37 50 02H
-0.84 13 1208 B
112 47 VS2 0.91 14 1248 B
38 51 VS4
-0.67 13 1209 B
112 59 VS2 0.24 14 1249 B
38 53 03H
-0.73 13 1210 B
114 129 VS4
-0.75 14 1250 B
38 115 04C 0.72 13 1211 B
115 126 03C 0.83 14 1251 B
38 147 VS4 1.15 13 1212 B
116 55 VS2
-0.85 14 1252 B
40 55 03H
-0.76 13 1213 B
116 81 07C
-0.25 14 1253 B
40 123 03C
-0.99 13 1214 B
116 111 05H
-0.88 14 1254 B
41 6
01C 0.74 13 1215 B
116 117 03C
-1.01 14 1255 B
41 12 VS4
-0.79 13 1216 B
116 125 04C
-0.11 14 1256 B
41 36 03H
-0.47 13 1217 B
117 44 02C 0.74 14 1257 B
41 48 VS4
-0.77 13 1218 B
118 41 02H 0.9 14 1258 B
42 47 03H
-0.82 13 1219 B
118 41 03C
-0.22 14 1259 B
43 8
03C 0.75 13 1220 B
118 73 VS6
-0.88 14 1260 B
44 57 VS4 0.19 13 1221 B
118 97 VS2
-0.81 14 1261 B
44 99 DBH 1.8 13 1222 B
120 61 08C 0.79 14 1262 B
45 64 DBC
-1.69 13 1223 B
124 73 VS2 0.78 14 1263 B
45 66 VS4 0.02 13 1224 B
124 85 VS4
-0.34 14 1264 B
45 66 VS4 0.76 13 1225 B
124 87 VS4 1
14 1265 B
46 33 VS4 0.14 13 1226 B
126 55 02C 0.76 14 1266 B
46 59 03C 0.79 13 1227 B
127 114 02C 0.79 14 1267 B
47 114 06C 0.78 13 1228 B
131 98 DBC 1.64 14 1268 B
47 148 04C 0.78 13 1229 B
131 102 04C 0.77 14 1269 B
48 67 VS4 0.99 13 1230 B
131 108 07H
-1.1 14 1270 B
49 56 03H
-0.91 13 1231 B
132 97 VS4
-0.87 14 1271 B
51 36 03C
-0.95 13 1232 B
132 101 06C
-0.25 14 1272 B
52 65 03C 0.76 13 Page 0-16
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1273 B
53 60 04H 1.03 13 1313 B
92 23 VS4 0.8 13 1274 B
53 118 02C
-0.29 13 1314 B
92 55 03C 0.78 13 1275 B
57 120 04C 0
13 1315 B
92 105 04C
-0.94 13 1276 B
58 47 03C
-1.05 13 1316 B
94 111 VS6
-0.76 13 1277 B
58 117 06C 0.81 13 1317 B
96 25 02H
-0.92 13 1278 B
59 88 03C 0.83 13 1318 B
96 79 VS2 0.72 13 1279 B
59 116 03C 0.81 13 1319 B
96 137 03C 0.78 13 1280 B
60 119 03C 0.64 13 1320 B
97 42 VS2
-0.99 13 1281 B
61 120 02C
-0.86 13 1321 B
98 27 VS4
-0.74 13 1282 B
62 155 01H 0.88 13 1322 B
98 27 VS4 1.04 13 1283 B
65 122 06C 0.76 13 1323 B
98 39 VS4 0.74 13 1284 B
66 29 06C
-0.96 13 1324 B
98 133 02C 0.79 13 1285 B
66 41 VS3
-0.7 13 1325 B
99 52 03C 0.76 13 1286 B
66 107 02H
-0.83 13 1326 B
102 49 VS2 0.93 13 1287 B
66 143 VS5 0.9 13 1327 B
104 33 03H 0.19 13 1288 B
67 108 03H 0.93 13 1328 B
105 40 03C
-1.14 13 1289 B
68 17 04H 0.92 13 1329 B
105 88 07C
-0.95 13 1290 B
68 93 04C
-0.09 13 1330 B
106 63 VS4
-0.79 13 1291 B
69 36 DBC 1.52 13 1331 B
106 101 VS2
-0.61 13 1292 B
69 140 VS3 1.08 13 1332 B
107 34 VS6
-0.69 13 1293 B
70 45 03H 0.93 13 1333 B
107 42 VS6 0.92 13 1294 B
71 136 06C
-0.14 13 1334 B
107 132 02C 0.77 13 1295 B
71 142 DBC 1.5 13 1335 B
107 132 07C 0.71 13 1296 B
73 40 05H 0.96 13 1336 B
110 41 02C 0.02 13 1297 B
73 86 02C
-0.98 13 1337 B
110 51 05H 0.9 13 1298 B
73 106 03H 0.95 13 1338 B
111 84 04H
-0.75 13 1299 B
74 19 DBC
-1.48 13 1339 B
111 128 03H
-0.72 13 1300 B
74 19 VS4
-0.72 13 1340 B
112 45 03H 0.91 13 1301 B
74 37 06H 0.95 13 1341 B
113 38 VS4
-0.7 13 1302 B
75 106 02H
-0.85 13 1342 B
113 122 03C
-0.99 13 1303 B
76 41 03C
-0.16 13 1343 B
115 126 03C
-0.88 13 1304 B
76 41 05C
-0.98 13 1344 B
117 40 02C
-0.25 13 1305 B
78 23 VS5 1.11 13 1345 B
123 116 03C 0.71 13 1306 B
78 105 02H
-0.82 13 1346 B
124 47 01C
-0.2 13 1307 B
82 43 VS5 0.75 13 1347 B
124 97 06C 0.86 13 1308 B
84 87 03H 0.88 13 1348 B
124 117 06C 0.78 13 1309 B
85 140 04C 0.64 13 1349 B
128 99 07C 0.81 13 1310 B
87 62 04C
-0.96 13 1350 B
130 79 VS2
-0.81 13 1311 B
89 104 04C
-1.02 13 1351 B
133 76 07C 0.87 13 1312 B
90 127 04H
-0.89 13 1352 B
135 76 06H 0.93 13 Page 0-17
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51 -9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1353 B
136 77 03H 0.9 13 1393 B
57 142 VS3 0.87 12 1354 B
138 87 VS1 0.93 13 1394 B
57 144 04C 0.72 12 1355 B
1 124 02C 0.69 12 1395 B
58 57 06C 0.59 12 1356 B
1 160 04H
-0.22 12 1396 B
58 59 02H 0
12 1357 B
14 37 DBH 2.03 12 1397 B
59 70 03H
-0.83 12 1358 B
14 159 02H
-0.77 12 1398 B
59 120 03C
-0.97 12 1359 B
23 106 VS4
-0.84 12 1399 B
62 47 03C 0.83 12 1360 B
25 6
02C
-0.89 12 1400 B
62 107 02C
-0.96 12 1361 B
25 36 04H
-0.77 12 1401 B
62 111 03H 0.11 12 1362 B
27 64 VS4
-0.13 12 1402 B
62 155 01H
-0.73 12 1363 B
30 53 02C 0.79 12 1403 B
62 155 01H
-0.09 12 1364 B
34 47 03H
-0.8 12 1404 B
63 126 VS3 1.06 12 1365 B
35 36 03H 1
12 1405 B
64 103 04C 0.83 12 1366 B
35 56 03H
-0.82 12 1406 B
65 16 06H
-0.13 12 1367 B
36 5
03C
-0.04 12 1407 B
66 41 VS4
-0.66 12 1368 B
36 161 02H 0.96 12 1408 B
66 51 04C
-0.25 12 1369 B
37 32 03H 0.76 12 1409 B
66 51 06C 0.8 12 1370 B
37 150 05H 0.92 12 1410 B
66 125 02C 0.73 12 1371 B
38 51 02C 0.81 12 1411 B
67 56 02C 0.87 12 1372 B
38 125 VS4 0.14 12 1412 B
67 56 04H
-0.81 12 1373 B
39 6
02C
-0.2 12 1413 B
67 62 02C
-0.22 12 1374 B
39 10 03C
-0.99 12 1414 B
67 104 03H 0.98 12 1375 B
39 108 DBH
-1.72 12 1415 B
68 45 DBC
-1.45 12 1376 B
43 6
05H
-0.11 12 1416 B
70 107 02H
-0.77 12 1377 B
44 29 VS4 0.74 12 1417 B
71 36 06C 0.82 12 1378 B
44 33 VS4 0.19 12 1418 B
71 36 DBC 1.74 12 1379 B
44 33 VS4 0.92 12 1419 B
71 42 04H
-0.77 12 1380 B
45 38 VS4
-0.6 12 1420 B
71 58 02C
-0.22 12 1381 B
46 21 VS4 1.01 12 1421 B
72 113 02H
-0.78 12 1382 B
46 33 DBC
-1.74 12 1422 B
74 37 04C
-0.96 12 1383 B
46 37 DBC
-1.53 12 1423 B
74 107 04H
-0.83 12 1384 B
47 132 VS4
-0.78 12 1424 B
76 29 VS3
-0.91 12 1385 B
48 125 03C 0.8 12 1425 B
77 50 05H
-0.75 12 1386 B
49 122 04C 0.8 12 1426 B
77 86 02C
-1.06 12 1387 B
51 36 03C 0.74 12 1427 B
78 81 03H 0.99 12 1388 B
51 58 01H 0.92 12 1428 B
78 109 02H
-0.86 12 1389 B
54 17 VS3
-0.73 12 1429 B
81 148 VS4
-0.92 12 1390 B
55 96 01C 0.88 12 1430 B
82 43 VS3
-0.85 12 1391 B
56 59 04H 0.94 12 1431 B
82 91 04C
-0.85 12 1392 B
57 90 03C
-1.02 12 1432 B
83 20 DBH 1.8 12 Page 0-18
ATTACHMENT 1 toAREVA-17-02174 fA Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1433 B
84 79 03H 0.95 12 1473 B
36 49 04H 0.85 11 1434 B
88 87 05C 0.82 12 1474 B
36 51 VS4
-0.66 11 1435 B
89 38 VS2
-0.89 12 1475 B
36 161 04C
-0.22 11 1436 B
89 42 VS6 0.96 12 1476 B
38 49 02H
-0.8 11 1437 B
89 104 04H 0.87 12 1477 B
39 8
03C 0.75 11 1438 B
90 23 VS4
-0.82 12 1478 B
40 115 03C 0.72 11 1439 B
90 115 03H
-0.85 12 1479 B
40 115 04C 0.77 11 1440 B
92 23 03H
-0.76 12 1480 B
45 114 03C 0.84 11 1441 B
92 73 VS2 0.93 12 1481 B
46 131 VS4 0.36 11 1442 B
97 38 05H 0.96 12 1482 B
48 159 01H
-0.88 11 1443 B
98 41 VS2
-0.7 12 1483 B
49 144 02H 0.88 11 1444 B
101 30 03H
-0.88 12 1484 B
53 120 04C 0.67 11 1445 B
101 36 05H 0.95 12 1485 B
55 56 03H 1.01 11 1446 B
103 48 07C 0.11 12 1486 B
57 142 04C 0.77 11 1447 B
105 32 01H 0.97 12 1487 B
61 124 02C 0.77 11 1448 B
105 42 07C 0.76 12 1488 B
62 53 06H 1.07 11 1449 B
105 118 DBH 1.89 12 1489 B
65 32 VS3
-0.72 11 1450 B
106 49 04H
-0.07 12 1490 B
65 118 02C 0.71 11 1451 B
106 51 VS2 1.08 12 1491 B
65 122 02C 0.78 11 1452 B
109 48 VS4
-0.72 12 1492 B
66 31 06C 0.83 11 1453 B
109 130 04C 0.67 12 1493 B
66 41 VS3
-0.19 11 1454 B
112 39 02H 0.9 12 1494 B
66 45 06C 0.72 11 1455 B
112 45 VS2
-0.72 12 1495 B
66 97 01C 0.69 11 1456 B
113 42 03C
-0.2 12 1496 B
66 107 02C
-0.98 11 1457 B
113 84 02H
-0.78 12 1497 B
67 46 DBC 1.76 11 1458 B
116 45 VS2 0.09 12 1498 B
67 78 03H 0.92 11 1459 B
117 40 05C 0.74 12 1499 B
68 113 04H
-0.75 11 1460 B
120 49 03C
-0.9 12 1500 B
69 140 VS4 1.05 11 1461 B
123 72 VS4
-0.67 12 1501 B
70 31 06C 0.78 11 1462 B
123 116 04C 0.73 12 1502 B
70 143 DBC 1.38 11 1463 B
124 85 VS2 0.21 12 1503 B
71 46 04H
-0.79 11 1464 B
124 105 06C 0.76 12 1504 B
71 52 02C
-0.9 11 1465 B
125 78 03H
-0.75 12 1505 B
72 113 04H 0.94 11 1466 B
127 104 06C 0.71 12 1506 B
73 14 VS4
-0.97 11 1467 B
132 91 DBC 1.72 12 1507 B
73 20 VS5 0.85 11 1468 B
132 97 VS1 0.92 12 1508 B
74 21 VS3 0.96 11 1469 B
134 99 VS4
-0.75 12 1509 B
74 37 DBC 1.64 11 1470 B
31 4
03C 0.09 11 1510 B
74 51 03C
-0.92 11 1471 B
32 109 04C 0.71 11 1511 B
74 53 VS3
-0.81 11 1472 B
34 59 03H
-0.83 11 1512 B
76 113 04H 0.11 11 Page 0-19
t ATTACHMENT 1 toAREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth Count SG Row Col Elev Offset Depth 1513 B
78 109 03H 0.22 11 1553 B
46 7
01C 0.71 10 1514 B
79 44 03C 0.78 11 1554 B
46 47 02H
-0.11 10 1515 B
79 54 03C 0.76 11 1555 B
47 8
01H 0.83 10 1516 B
82 19 VS4 1.07 11 1556 B
57 146 DBH 1.65 10 1517 B
82 43 VS4
-0.88 11 1557 B
61 48 VS3
-0.89 10 1518 B
82 129 DBH 1.75 11 1558 B
62 39 04H
-0.09 10 1519 B
85 20 VS4
-0.82 11 1559 B
62 47 DBC
-1.5 10 1520 B
89 104 05C
-0.98 11 1560 B
62 85 DBC
-1.82 10 1521 B
90 87 02C
-0.98 11 1561 B
66 41 DBC
-1.75 10 1522 B
90 87 02C
-0.2 11 1562 B
67 56 02H 0.92 10 1523 B
92 75 05H 0.99 11 1563 B
69 102 03H 0.93 10 1524 B
93 98 04C
-0.93 11 1564 B
70 47 04C
-0.25 10 1525 B
93 104 04H
-0.74 11 1565 B
71 36 DBC
-1.85 10 1526 B
94 93 04C
-0.96 11 1566 B
71 112 04C 0.78 10 1527 B
99 132 VS2
-0.11 11 1567 B
72 25 DBC 1.74 10 1528 B
100 27 VS4 0.95 11 1568 B
72 113 04C 0.83 10 1529 B
104 117 05C 0.84 11 1569 B
73 14 VS4 0.31 10 1530 B
105 36 04H
-0.13 11 1570 B
76 65 VS4
-0.07 10 1531 B
105 78 VS2
-0.22 11 1571 B
81 148 03C 0.83 10 1532 B
109 84 04H
-0.11 11 1572 B
86 91 03C
-0.89 10 1533 B
110 37 03C
-0.98 11 1573 B
92 23 VS4
-0.84 10 1534 B
110 55 VS2 0.92 11 1574 B
101 38 DBC 1.39 10 1535 B
113 42 05H
-0.04 11 1575 B
102 113 DBH 1.78 10 1536 B
116 97 04C
-0.29 11 1576 B
105 88 VS2
-0.9 10 1537 B
118 101 08C 0.86 11 1577 B
111 40 DBC
-1.81 10 1538 B
118 123 02C 0.81 11 1578 B
113 84 04H
-0.81 10 1539 B
119 112 03C
-0.89 11 1579 B
114 127 05C 0.76 10 1540 B
120 47 03C
-1.01 11 1580 B
117 40 01C
-0.99 10 1541 B
124 47 03C 0.72 11 1581 B
119 88 08C
-0.22 10 1542 B
126 81 VS4
-0.63 11 1582 B
126 55 06H 1.06 10 1543 B
126 115 02C 0
11 1583 B
129 102 08C 0.02 10 1544 B
127 52 01H
-0.09 11 1584 B
30 7
03C 0
9 1545 B
127 114 03C 0.82 11 1585 B
41 120 05C 0.93 9
1546 B
16 55 DBH
-1.63 10 1586 B
44 121 03C 0.82 9
1547 B
19 60 03H
-0.85 10 1587 B
58 25 06H 0.93 9
1548 B
37 36 03H
-0.84 10 1588 B
66 47 06C
-0.18 9
1549 B
39 6
02C 0.68 10 1589 B
69 36 04C 0.8 9
1550 B
39 146 DBC 1.56 10 1590 B
69 48 04C 0
9 1551 B
41 40 02C
-0.25 10 1591 B
71 86 02C
-0.18 9
1552 B
45 16 DBH
-1.76 10 1592 B
72 113 02H 0.91 9
Page 0-20
ATTACHMENT 1 to AREVA-17-02174 A
Document No.: 51-9275005-000 AREVA Palisades 1 R25 2017 180-Day Steam Generator Tube Inspection Report Count SG Row Col Elev Offset Depth 1593 B
74 47 06C 0
9 1594 B
89 38 05H
-0.84 9
1595 B
92 31 VS2 0.97 9
1596 B
92 97 04C
-0.02 9
1597 B
102 99 07C 0.07 9
1598 B
103 48 DBC
-1.31 9
1599 B
105 32 VS4
-0.85 9
1600 B
106 101 VS2
-0.19 9
1601 B
124 85 VS2 0.75 9
1602 B
30 5
02H
-0.15 8
1603 B
36 109 04C 0.8 8
1604 B
49 12 DBC 1.54 7
Page 0-21