05000335/LER-1979-030, Forwards LER 79-030/01T-0

From kanterella
(Redirected from ML17207A479)
Jump to navigation Jump to search
Forwards LER 79-030/01T-0
ML17207A479
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 10/05/1979
From: Schmidt A
FLORIDA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17207A480 List:
References
NUDOCS 7910190335
Download: ML17207A479 (2)


LER-1979-030, Forwards LER 79-030/01T-0
Event date:
Report date:
3351979030R00 - NRC Website

text

a~('InG HEI.'

i< 1'~Tl~

. c FLORIDA POWER 4 LIGHTCOMPANY October 5, 1979 PRN-LI-79-365 Mr. James P. O'Reilly, Director, Region II Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Rei lly:

REPORTABLE OCCURRENCE 335-79-30 ST.

LUCIE UNIT 1

DATE OF OCCURRENCE:

SEPTEMBER 21 1979 STEAM GENERATOR LOW-LEVEL SETPOINT The attached Licensee Event Report is being submitted in accordance with Technical Specification 6.9 to provide prompt notification of the subject occurrence.

Very truly yours, D. Schmidt Vice President Power Resources MAS/ld Attachment cc:

Director, Office of Inspection and Enforcement (40)

Director, Office of Management Information and Program Control (3)

Harold F. Reis, Esquire Fi le 933.1 SL 7910190 S>+

OFP'IDEAL COPY PEOPLE... SERVING PEOPLE