From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Abel J
COMMONWEALTH EDISON CO.
References
TASK-02-01.B, TASK-02-02.B, TASK-02-02.D, TASK-03-08.B, TASK-06-08, TASK-15-08, TASK-15-13, TASK-15-14, TASK-15-8, TASK-2-1.B, TASK-2-2.B, TASK-2-2.D, TASK-3-8.B, TASK-6-8, TASK-RR NUDOCS 8010090536
Download: ML17193A105 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket No. 50-237 Mr. J. S. Abel Director of Nuclear Licensing Corrmonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Abel:

September 11, 1980 By letter dated November 16, 1979, we sent you the list of topics which would not be reviewed by your plant in the Systematic Evaluation Program (SEP).

These topics were deleted from the SEP review because they were not applicable to your plant or they were being reviewed as part of an ongoing generic issue outside the SEP.

The following topics should be added to the November 16 listing.

Removal of these additional topics from the SEP review results from (1) related generic NRC activities, and (2) non-applicability of topics to certain facilities.

The following is a list of s.uch topics and indicates their disposi~ion:

Topic Categorization 11-2.B Generic II-2. D Generic II I-8. B Complete VI-8 Generic Disposition Compliance with Appendix E is being evaluated under the Emergency Preparedness Program Office (EPPO) effort. Compli-ance with Appendix I is being evaluated as part of the NRC Appendix I review effort.

. Compliance is being evaluated under the EPPO effort.

The review published as NUREG 0479, "Report on BWR Control Rod Ori ve Fa i hires 11 fu l fi 11 s the intent of this topic.

Will be reviewed by NRC as part of TMI Task Action Plan (NUREG" 0660) as specified in May 7, 1980 letter to all operating reactor licensees.

{:_.

Mr. J. September 11, 1980 Those parts of Topic II-1.B "Population Distribution relating to emergency plans wi11 be evaluated by EPPO.. In addition,.the original DBE review list indicated that DBE group VI events "Uncontrolled Rod Assembly Withdrawal at Power" and "Uncontrolled Rod Assembly Withdrawal - Low Power Startup" are a part of Topic XI-13.

However, the topic of reference should be Topic XV-8, "Control Rod Misoperation 11 and accordingly the references for Topic XV-8 should include Standard Review Plans 15.4.1 and 15.4.2. Also, the November 16, 1979 letter states that DBE Group X; "Inadvertent Operation of ECCS or CVCS Malfunction that Causes an Increase in Reactor Coolant Inventory" should be deleted as it applies only to PWRs.

However. Group X will be included in the SEP review since inadvertent operation of ECCS should be evaluated for BWRs.

Enclosure l to this letter includes a revised listing of the DBE Accident and Tran~ient Groups applicable to BWRs.

Of note should be the inclusion of Group XI, "Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position," revision to Group III to include "Radiological Consequences of a Main Steam Line Failure Outside Containment", and the Inclusion of Fuel Handling Accidents in Group VII I.

Enclosure:

As stated cc w/enclosure:

See next page

/

Sincerely, L7'1---~

D~nnis M. Crutchfield, ie Operating Reactors Branch #5 Divfsion of Licensing

Mr. J. S. Abel cc:

Isham, Lincoln & Beale Counselors at Law,

One First National Plaza, 42nd Floor Chicago, Illinois 60603 Mr. B. B. Stephenson Plant Superintendent Dresden Nuclear Power Station Rural Route #1 Morris, Illinois 60450 Natural Resources Defense Council 917 15th Street, N. w.

Washington, D. c.

20005 U. S. Nuclear Regulatory Commission Resident Inspectors Office Dresden Station RR #1 Morris, Illinois 60450 Susan N. Sekuler Assistant Attorney General Environmental Control Division 188 W. Randolph Street Suite 2315 Chicago, Illinois* 60601 Morris Public Library 604 Liberty Street Morris, Illinois 60451 Chairman Board of Supervisors of Grundy County Grundy County Courthouse Morris, Illinois 60450 September 11, 1980 Department of Public.Health ATTN:

Chief, Division of Nuclear Safety 535 West Jefferson Springfield, Illinois 62761 Director, Technical Assessment Division

  • Office of Radiation Programs (AW-459)

U. S. Environmental Protection Agency Crystal Mal 1 #2 Arlington, Virginia 20460

u. S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN:

EIS COORDINATOR 230 South Dearborn Street Chicago, Illinois 60604 Resident Inspector Dresden Nuclear Power Station c/o u. s. NRC Rural Route #l Morris, Illinois 60450

GROUP VI VI I VIII IX x*

XI XII GROUP I

II

....... *-- **-**:-**---~-~---*-*-** *--- -** -

RELATED SEP TOPIC XV-8 XV-8 XV-8 XV-13 XV-19 XV-20 XV-21 XV-15 XV-14 XV-11 RELATED

~ 2 -

BWR DBE LIST (continued)

DESIGN BASIS EVENT SRP SECTION Uncontrolled rod assembly withdrawal 15.4.2 at power Uncontrolled rod assembl'y withdrawal 15.4.l low power start-up Control ~od misoperation

  • 15.4.3 Spectrum of rod drop accidents
  • 15.4.9 Spectrum of rod drop acciaents 15.6.5 Radiological consequences of fuel 15.7.4 damaging accidents (inside ana outside containment)

Drop of cask or heavy equipment 15.7.5 Inadvertent opening of BSR safety/

15.6.1 relief valve Inadvertent operation of ECCS 15.5.l Inadvertent loading and operaticn of 15.4.7 a fuel assembly in an improper position Not applicable to BWR 1 s PWR DBE LIST SEP TOPIC QESIGN BASIS EVENT SRP SECTION XV-1 XV-1

. XV-1 XV-1 XV-9 XV-10 XV-3 xv.:.3 XV-3 XV-3 XV-5 XV-6 Decrease in feedwater temperature Increase in feedwater flow Increase in steam flow Inadvertent opening of steam generator relief/safety valve Start-up of inactive loop System malfunction causing a decrease in boron concentration Loss of external load Turbine trip Loss of condenser vacuum Steam pressure regulatory failure loss of feedwater flow Feedwater system pipe break 15.1.1

15. 1. 2 15.1.3
15. 1. 4 15.4.4 15.4.6 15.2.1
15. 2. 2 15.2.3 15.2.5 15.2.7 15.2.8