ES-401 BWR Examination Outline FORM ES-401-1 Facility Name: Clinton Power Station Date of Exam: 1/30/17 K
1 K
2 K
3 K
4 K
5 K
6 A
1 A
2 A
3 A
4 G
Total Total 1
3 4
3 4
3 3
20 7
2 1
2 1
1 1
1 7
3 Tier Totals 4
6 4
5 4
4 27 10 1
3 2
3 2
2 2
3 2
2 2
3 26 5
2 2
1 1
1 1
1 1
1 1
1 1
12 0
2 3
Tier Totals 5
3 4
3 3
3 4
3 3
3 4
38 8
1 2
3 4
2 2
1 2
Note: 1.
Note: 2.
Note: 3.
Note: 4.
Note: 5.
Note: 6.
Note: 7.
Note: 8.
Note: 9.
G*
ES-401, Page 16 of 33 5
2 For Tier 3, select topics from Section 2 of the K/A catalog, and enter the K/A numbers, descriptions, IRs, and point totals (#) on Form ES-401-3. Limit SRO selections to K/As that are linked to 10 CFR 55.43.
Absent a plant-specific priority, only those K/As having an importance rating (IR) of 2.5 or higher shall be selected.
Use the RO and SRO ratings for the RO and SRO-only portions, respectively.
Select SRO topics for Tiers 1 and 2 from the shaded systems and K/A categories.
The generic (G) K/As in Tiers 1 and 2 shall be selected from Section 2 of the K/A Catalog, but the topics must be relevant to the applicable evolution or system. Refer to Section D.1.b of ES-401 for the applicable K/As.
On the following pages, enter the K/A numbers, a brief description of each topic, the topics importance ratings (IRs) for the applicable license level, and the point totals (#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in other than Category A2 or G* on the SRO-only exam, enter it on the left side of Column A2 for Tier 2, Group 2 (Note #1 does not apply). Use duplicate pages for RO and SRO-only exams.
Generic K/As
- 3. Generic Knowledge and Abilities Categories 1
3 2
3 5
3 Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting a second topic for any system or evolution.
RO K/A Category Points 7
10 Ensure that at least two topics from every applicable K/A category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the Tier Totals in each K/A category shall not be less than two).(One Tier 3 Radiation Control K/A is allowed if the K/A is replaced by a K/A from another Tier 3 Category).
3 The point total for each group and tier in the proposed outline must match that specified in the table.
The final point total for each group and tier may deviate by +/-1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.
Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems that are not included on the outline should be added. Refer to Section D.1.b of ES-401 for guidance regarding the elimination of inappropriate K/A statements.
N/A N/A G*
2 5
Tier Group SRO-Only Points
- 2.
Plant Systems
- 1.
Emergency &
Abnormal Plant Evolutions 1
3 3
2 4
2 A2 4
1
ES-401 2
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 (RO)
Q#
E/APE # / Name / Safety Function K
1 K
2 K
3 A
1 A
2 G
K/A Topic(s)
IR 295001 Partial or Complete Loss of Forced Core Flow Circulation / 1 & 4 0
6 295003 Partial or Complete Loss of AC / 6 0
3 Knowledge of the interrelations between Partial or Complete Loss of AC and the following: A.C. electrical distribution system 3.7 1
5 295004 Partial or Total Loss of DC Pwr / 6 0
1 Knowledge of the interrelations between Partial or Total Loss of DC Pwr and the following: Battery charger 3.1 1
8 295005 Main Turbine Generator Trip / 3 0
5 Knowledge of the reasons for the following responses as they apply to Main Turbine Generator Trip: Extraction steam/moisture separator isolations 2.5 1
13 295006 SCRAM / 1 0
6 Ability to determine and/or interpret the following as they apply to SCRAM: Cause of reactor SCRAM 3.5 1
4 295016 Control Room Abandonment / 7 0
1 Knowledge of the interrelations between Control Room Abandonment and the following: Remote shutdown panel: Plant-Specific 4.4 1
20 295018 Partial or Total Loss of CCW / 8 0
3 Ability to operate and/or monitor the following as they apply to Partial or Total Loss of CCW: Affected systems so as to isolate damaged portions 3.3 1
7 295019 Partial or Total Loss of Inst. Air / 8 0
3 Knowledge of the reasons for the following responses as they apply to Partial or Total Loss of Inst. Air: Service air isolations: Plant-Specific 3.2 1
16 295021 Loss of Shutdown Cooling / 4 04.
11 Knowledge of abnormal condition procedures.
4.0 1
19 295023 Refueling Acc / 8 0
4 Knowledge of the interrelations between Refueling Accidents and the following:
RMCS/Rod control and information system 3.2 1
17 295024 High Drywell Pressure / 5 04.
09 Knowledge of low power/shutdown implications in accident (e.g., loss of coolant accident or loss of residual heat removal) mitigation strategies.
3.8 1
18 295025 High Reactor Pressure / 3 01.
28 Knowledge of the purpose and function of major system components and controls.
4.1 1
10 295026 Suppression Pool High Water Temp. / 5 0
1 Ability to operate and/or monitor the following as they apply to Suppression Pool High Water Temp.: Suppression pool cooling 4.1 1
3 295027 High Containment Temperature / 5 0
3 Knowledge of the operational implications of the following concepts as they apply to High Containment Temperature: Containment integrity: Mark-III 3.8 1
2 295028 High Drywell Temperature / 5 0
1 Knowledge of the operational implications of the following concepts as they apply to High Drywell Temperature: Reactor water level measurement 3.5 1
1 295030 Low Suppression Pool Wtr Lvl / 5 0
3 Knowledge of the operational implications of the following concepts as they apply to Low Suppression Pool Wtr Lvl: Heat capacity 3.8 1
11 295031 Reactor Low Water Level / 2 1
0 Ability to operate and/or monitor the following as they apply to Reactor Low Water Level: Control rod drive 3.6 1
15 295037 SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown / 1 0
1 Ability to determine and/or interpret the following as they apply to SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown: Reactor power 4.2 1
12 295038 High Off-site Release Rate / 9 0
6 Ability to operate and/or monitor the following as they apply to High Off-site Release Rate: Plant ventilation 3.5 1
14 600000 Plant Fire On Site / 8 1
2 Ability to determine and/or interpret the following as they apply to Plant Fire On Site:
Location of vital equipment within fire zone 3.1 1
9 700000 Generator Voltage and Electric Grid Disturbances / 6 0
2 Knowledge of the reasons for the following responses as they apply to Generator Voltage and Electric Grid Disturbances: Actions contained in abnormal operating procedure for voltage and grid disturbances 3.6 1
K/A Category Totals:
3 4
3 4
3 3
20 ES-401, Page 17 of 33 Group Point Total:
ES-401 3
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 (RO)
Q#
E/APE # / Name / Safety Function K
1 K
2 K
3 A
1 A
2 G
K/A Topic(s)
IR 295002 Loss of Main Condenser Vac / 3 0
25 295007 High Reactor Pressure / 3 0
2 Ability to determine and/or interpret the following as they apply to High Reactor Pressure: Reactor power 4.1 1
23 295008 High Reactor Water Level / 2 0
4 Knowledge of the reasons for the following responses as they apply to High Reactor Water Level: Reactor feed pump trip: Plant-Specific 3.3 1
295009 Low Reactor Water Level / 2 0
24 295010 High Drywell Pressure / 5 0
1 Ability to operate and/or monitor the following as they apply to High Drywell Pressure: Drywell ventilation/cooling 3.4 1
295011 High Containment Temp / 5 0
26 295012 High Drywell Temperature / 5 04.
01 Knowledge of EOP entry conditions and immediate action steps.
4.6 1
295013 High Suppression Pool Temp. / 5 0
295014 Inadvertent Reactivity Addition / 1 0
295015 Incomplete SCRAM / 1 0
295017 High Off-site Release Rate / 9 0
295020 Inadvertent Cont. Isolation / 5 & 7 0
295022 Loss of CRD Pumps / 1 0
27 295029 High Suppression Pool Wtr Lvl / 5 0
6 Knowledge of the interrelations between High Suppression Pool Wtr Lvl and the following: SRV's and discharge piping 3.4 1
22 295032 High Secondary Containment Area Temperature / 5 0
2 Knowledge of the interrelations between High Secondary Containment Area Temperature and the following: Secondary containment ventilation 3.6 1
295033 High Secondary Containment Area Radiation Levels / 9 0
295034 Secondary Containment Ventilation High Radiation / 9 0
295035 Secondary Containment High Differential Pressure / 5 0
21 295036 Secondary Containment High Sump/Area Water Level / 5 0
2 Knowledge of the operational implications of the following concepts as they apply to Secondary Containment High Sump / Area Water Level: Electrical ground/ circuit malfunction 2.6 1
500000 High CTMT Hydrogen Conc. / 5 0
K/A Category Totals:
1 2
1 1
1 1
7 ES-401, Page 18 of 33 Group Point Total:
ES-401 4
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 1 (RO)
Q#
System # / Name K
1 K
2 K
3 K
4 K
5 K
6 A
1 A
2 A
3 A
4 G
K/A Topic(s)
IR 41, 49 203000 RHR/LPCI: Injection Mode 0
1 01.
30 Ability to predict and/or monitor changes in parameters associated with operating the RHR/LPCI: Injection Mode controls including: Reactor water level; Ability to locate and operate components, including local controls.
4.2; 4.4 2
48 205000 Shutdown Cooling 02.
38 Knowledge of conditions and limitations in the facility license.
3.6 1
206000 HPCI 0
207000 Isolation (Emergency)
Condenser 0
31 209001 LPCS 0
2 Knowledge of electrical power supplies to the following: Valve power 2.5 1
37 209002 HPCS 0
1 Knowledge of the physical connections and/or cause-effect relationships between HPCS and the following: Condensate transfer and storage system:
BWR-5, 6 3.4 1
29 211000 SLC 0
2 Knowledge of the physical connections and/or cause-effect relationships between SLC and the following: Core plate differential pressure indication 2.7 1
32 212000 RPS 0
6 Knowledge of the effect that a loss or malfunction of the RPS will have on following: Scram air header solenoid operated valves 4.0 1
40 215003 IRM 0
5 Ability to predict and/or monitor changes in parameters associated with operating the IRM controls including: SCRAM and rod block trip setpoints 3.9 1
30 215004 Source Range Monitor 0
1 Knowledge of electrical power supplies to the following: SRM channels/detectors 2.6 1
3 Knowledge of the effect that a loss or malfunction of the following will have on the APRM / LPRM: Detectors 3.1 1
53 217000 RCIC 01.
25 Ability to interpret reference materials, such as graphs, curves, tables, etc.
3.9 1
42, 50 218000 ADS 0
2 0
5 Knowledge of the physical connections and/or cause-effect relationships between ADS and the following: Low pressure core spray: Plant-Specific; Ability to (a) predict the impacts of the following on the ADS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Loss of A.C. or D.C. power to ADS valves 4; 3.4 2
39, 51 223002 PCIS/Nuclear Steam Supply Shutoff 1
1 0
7 Knowledge of the effect that a loss or malfunction of the PCIS/Nuclear Steam Supply Shutoff will have on following: Plant ventilation; Knowledge of the effect that a loss or malfunction of the following will have on the PCIS/Nuclear Steam Supply Shutoff: Essential A.C. power 2.8; 3.2 2
28 239002 SRVs 0
1 Knowledge of the operational implications of the following concepts as they apply to SRVs: Relief function of SRV operation 3.4 1
36 259002 Reactor Water Level Control 0
1 Knowledge of the operational implications of the following concepts as they apply to Reactor Water Level Control: GEMAC/Foxboro/Bailey controller operation: Plant-Specific 3.1 1
34 261000 SGTS 0
3 Knowledge of SGTS design feature(s) and/or interlocks which provide for the following: Moisture removal 2.5 1
35, 44 262001 AC Electrical Distribution 0
5 0
4 Knowledge of AC Electrical Distribution design feature(s) and/or interlocks which provide for the following: Paralleling of A.C. sources (synchroscope);
Ability to monitor automatic operations of the AC Electrical Distribution including: Load sequencing 3.4; 3.4 2
43 262002 UPS (AC/DC) 0 1
Ability to (a) predict the impacts of the following on the UPS (AC/DC); and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Under voltage 2.6 1
45 263000 DC Electrical Distribution 0
1 Ability to monitor automatic operations of the DC Electrical Distribution including: Meters, dials, recorders, alarms, and indicating lights 3.2 1
46 264000 EDGs 0
2 Ability to manually operate and/or monitor in the control room: Synchroscope 3.4 1
47 300000 Instrument Air 0
1 Ability to manually operate and/or monitor in the control room: Pressure gauges 2.6 1
33, 52 400000 Component Cooling Water 0
1 0
2 Knowledge of the effect that a loss or malfunction of the Component Cooling Water will have on following: Loads cooled by CCWS; Ability to predict and/or monitor changes in parameters associated with operating the Component Cooling Water controls including: CCW temperature 2.9; 2.8 2
K/A Category Totals:
3 2
3 2
2 2
3 2
2 2
3 26 ES-401, Page 19 of 33 Group Point Total:
ES-401-1 5
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 2 (RO)
Q#
System # / Name K
1 K
2 K
3 K
4 K
5 K
6 A
1 A
2 A
3 A
4 G
K/A Topic(s)
IR 201001 CRD Hydraulic 0
201002 RMCS 0
57 201003 Control Rod and Drive Mechanism 0
1 Knowledge of Control Rod and Drive Mechanism design feature(s) and/or interlocks which provide for the following: Limiting control rod speed in the event of a rod drop 2.9 1
201004 RSCS 0
62 201005 RCIS 0
1 Ability to monitor automatic operations of the RCIS including: Operator control module lights: BWR-6 3.5 1
201006 RWM 0
59 202001 Recirculation 0
3 Knowledge of the effect that a loss or malfunction of the following will have on the Recirculation: A.C. power: Plant-Specific 2.9 1
202002 Recirculation Flow Control 0
61 204000 RWCU 0
7 Ability to (a) predict the impacts of the following on the RWCU; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Loss of plant air systems 2.5 1
214000 RPIS 0
215001 Traversing In-core Probe 0
215002 RBM 0
216000 Nuclear Boiler Inst.
0 56 219000 RHR/LPCI: Torus/Pool Cooling Mode 0
1 Knowledge of the effect that a loss or malfunction of the RHR/LPCI: Torus/Pool Cooling Mode will have on following: Suppression pool temperature control 3.9 1
223001 Primary CTMT and Aux.
0 226001 RHR/LPCI: CTMT Spray Mode 0
230000 RHR/LPCI: Torus/Pool Spray Mode 0
60 233000 Fuel Pool Cooling/Cleanup 0
6 Ability to predict and/or monitor changes in parameters associated with operating the Fuel Pool Cooling/Cleanup controls including: System flow 2.5 1
234000 Fuel Handling Equipment 0
239001 Main and Reheat Steam 0
239003 MSIV Leakage Control 0
241000 Reactor/Turbine Pressure Regulator 0
63 245000 Main Turbine Gen. / Aux.
0 1 Ability to manually operate and/or monitor in the control room: Turbine lube oil pumps 2.7 1
54 256000 Reactor Condensate 2
5 Knowledge of the physical connections and/or cause-effect relationships between Reactor Condensate and the following: Main steam system: Plant-Specific 3.0 1
259001 Reactor Feedwater 0
268000 Radwaste 0
271000 Offgas 0
64 272000 Radiation Monitoring 04.
04 Ability to recognize abnormal indications for system operating parameters that are entry-level conditions for emergency and abnormal operating procedures.
4.5 1
55 286000 Fire Protection 0
2 Knowledge of electrical power supplies to the following: Pumps 2.9 1
65 288000 Plant Ventilation 0 2 Knowledge of the physical connections and/or cause-effect relationships between Plant Ventilation and the following: Secondary containment 3.4 1
290001 Secondary CTMT 0
58 290003 Control Room HVAC 0
1 Knowledge of the operational implications of the following concepts as they apply to Control Room HVAC : Airborne contamination (e.g., radiological, toxic gas, smoke) control 3.2 1
290002 Reactor Vessel Internals 0
K/A Category Totals:
2 1
1 1
1 1
1 1
1 1
1 12 ES-401, Page 20 of 33 Group Point Total:
ES-401 2
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 (SRO)
Q#
E/APE # / Name / Safety Function K
1 K
2 K
3 A
1 A
2 G
K/A Topic(s)
IR 295001 Partial or Complete Loss of Forced Core Flow Circulation / 1 & 4 0
76 295003 Partial or Complete Loss of AC / 6 0
2 Ability to determine and/or interpret the following as they apply to Partial or Complete Loss of AC: Reactor power, pressure, and level 4.3 1
295004 Partial or Total Loss of DC Pwr / 6 0
295005 Main Turbine Generator Trip / 3 0
80 295006 SCRAM / 1 02.
40 Ability to apply Technical Specifications for a system.
4.7 1
295016 Control Room Abandonment / 7 0
295018 Partial or Total Loss of CCW / 8 0
295019 Partial or Total Loss of Inst. Air / 8 0
295021 Loss of Shutdown Cooling / 4 0
81 295023 Refueling Acc / 8 01.
07 Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation 4.7 1
79 295024 High Drywell Pressure / 5 04.
06 Knowledge of EOP mitigation strategies.
4.7 1
295025 High Reactor Pressure / 3 0
295026 Suppression Pool High Water Temp. / 5 0
295027 High Containment Temperature / 5 0
295028 High Drywell Temperature / 5 0
295030 Low Suppression Pool Wtr Lvl / 5 0
82 295031 Reactor Low Water Level / 2 0
3 Ability to determine and/or interpret the following as they apply to Reactor Low Water Level: Reactor pressure 4.2 1
78 295037 SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown / 1 0
3 Ability to determine and/or interpret the following as they apply to SCRAM Condition Present and Reactor Power Above APRM Downscale or Unknown: SBLC tank level 4.4 1
295038 High Off-site Release Rate / 9 0
77 600000 Plant Fire On Site / 8 0
4 Ability to determine and/or interpret the following as they apply to Plant Fire On Site: The fire's extent of potential operational damage to plant equipment 3.1 1
700000 Generator Voltage and Electric Grid Disturbances / 6 0
K/A Category Totals:
0 0
0 0
4 3
7 ES-401, Page 17 of 33 Group Point Total:
ES-401 3
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 (SRO)
Q#
E/APE # / Name / Safety Function K
1 K
2 K
3 A
1 A
2 G
K/A Topic(s)
IR 83 295002 Loss of Main Condenser Vac / 3 0
1 Ability to determine and/or interpret the following as they apply to Loss of Main Condenser Vac: Condenser vacuum/absolute pressure 3.1 1
295007 High Reactor Pressure / 3 0
295008 High Reactor Water Level / 2 0
295009 Low Reactor Water Level / 2 0
295010 High Drywell Pressure / 5 0
84 295011 High Containment Temp / 5 02.
25 Knowledge of the bases in Technical Specifications for limiting conditions for operations and safety limits.
4.2 1
295012 High Drywell Temperature / 5 0
295013 High Suppression Pool Temp. / 5 0
295014 Inadvertent Reactivity Addition / 1 0
295015 Incomplete SCRAM / 1 0
85 295017 High Off-site Release Rate / 9 01.
23 Ability to perform specific system and integrated plant procedures during all modes of plant operation.
4.4 1
295020 Inadvertent Cont. Isolation / 5 & 7 0
295022 Loss of CRD Pumps / 1 0
295029 High Suppression Pool Wtr Lvl / 5 0
295032 High Secondary Containment Area Temperature / 5 0
295033 High Secondary Containment Area Radiation Levels / 9 0
295034 Secondary Containment Ventilation High Radiation / 9 0
295035 Secondary Containment High Differential Pressure / 5 0
295036 Secondary Containment High Sump/Area Water Level / 5 0
500000 High CTMT Hydrogen Conc. / 5 0
K/A Category Totals:
0 0
0 0
1 2
3 ES-401, Page 18 of 33 Group Point Total:
ES-401 4
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 1 (SRO)
Q#
System # / Name K
1 K
2 K
3 K
4 K
5 K
6 A
1 A
2 A
3 A
4 G
K/A Topic(s)
IR 203000 RHR/LPCI: Injection 0
205000 Shutdown Cooling Mode 0
206000 HPCI 0
207000 Isolation (Emergency)
Condenser 0
87 209001 LPCS 0
5 Ability to (a) predict the impacts of the following on the LPCS; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Core spray line 3.6 1
88 209002 HPCS 02.
12 Knowledge of surveillance procedures.
4.1 1
211000 SLC 0
212000 RPS 0
215003 IRM 0
215004 Source Range Monitor 0
8 Ability to (a) predict the impacts of the following on the APRM / LPRM; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Faulty or erratic operation of detectors/systems 3.4 1
90 217000 RCIC 0
5 Ability to (a) predict the impacts of the following on the RCIC; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: D.C. power loss 3.3 1
218000 ADS 0
223002 PCIS/Nuclear Steam Supply Shutoff 0
89 239002 SRVs 04.
08 Knowledge of how abnormal operating procedures are used in conjunction with EOPs.
4.5 1
259002 Reactor Water Level Control 0
261000 SGTS 0
262001 AC Electrical Distribution 0
262002 UPS (AC/DC) 0 263000 DC Electrical Distribution 0
264000 EDGs 0
300000 Instrument Air 0
400000 Component Cooling Water 0
K/A Category Totals:
0 0
0 0
0 0
0 3
0 0
2 5
ES-401, Page 19 of 33 Group Point Total:
ES-401 5
Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 2 (SRO)
Q#
System # / Name K
1 K
2 K
3 K
4 K
5 K
6 A
1 A
2 A
3 A
4 G
K/A Topic(s)
IR 201001 CRD Hydraulic 0
201002 RMCS 0
201003 Control Rod and Drive Mechanism 0
201004 RSCS 0
201005 RCIS 0
201006 RWM 0
202001 Recirculation 0
202002 Recirculation Flow Control 0
204000 RWCU 0
214000 RPIS 0
215001 Traversing In-core Probe 0
215002 RBM 0
91 216000 Nuclear Boiler Inst.
0 8
Ability to (a) predict the impacts of the following on the Nuclear Boiler Inst.; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Elevated containment temperature 3.4 1
219000 RHR/LPCI: Torus/Pool Cooling Mode 0
223001 Primary CTMT and Aux.
0 226001 RHR/LPCI: CTMT Spray Mode 0
230000 RHR/LPCI: Torus/Pool Spray Mode 0
233000 Fuel Pool Cooling/Cleanup 0
92 234000 Fuel Handling Equipment 02.
37 Ability to determine operability and/or availability of safety related equipment.
4.6 1
93 239001 Main and Reheat Steam 0
8 Ability to (a) predict the impacts of the following on the Main and Reheat Steam; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Low condenser vacuum 3.6 1
239003 MSIV Leakage Control 0
241000 Reactor/Turbine Pressure Regulator 0
245000 Main Turbine Gen. / Aux.
0 256000 Reactor Condensate 0
259001 Reactor Feedwater 0
268000 Radwaste 0
271000 Offgas 0
272000 Radiation Monitoring 0
286000 Fire Protection 0
288000 Plant Ventilation 0
290001 Secondary CTMT 0
290003 Control Room HVAC 0
290002 Reactor Vessel Internals 0
K/A Category Totals:
0 0
0 0
0 0
0 2
0 0
1 3
ES-401, Page 20 of 33 Group Point Total:
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Form ES-401-3 Facility Name:Clinton Power Station Date of Exam:1/30/17 Q#
IR IR 94 2.1. 40 Knowledge of refueling administrative requirements.
2.8 3.9 1
95 2.1. 20 Ability to interpret and execute procedure steps.
4.6 4.6 1
66 2.1. 05 Ability to use procedures related to shift staffing, such as minimum crew complement, overtime limitations, etc.
2.9 1
3.9 67 2.1. 13 Knowledge of facility requirements for controlling vital/controlled access.
2.5 1
3.2 68 2.1. 31 Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup.
4.6 1
4.3 2.1.
Subtotal 3
2 96 2.2. 22 Knowledge of limiting conditions for operations and safety limits.
4.0 4.7 1
97 2.2. 11 Knowledge of the process for controlling temporary design changes.
2.3 3.3 1
69 2.2. 42 Ability to recognize system parameters that are entry-level conditions for Technical Specifications.
3.9 1
4.6 70 2.2. 01 Ability to perform pre-startup procedures for the facility, including operating those controls associated with plant equipment that could affect reactivity.
4.5 1
4.4 2.2.
2.2.
Subtotal 2
2 98 2.3. 11 Ability to control radiation releases.
3.8 4.3 1
71 2.3. 04 Knowledge of radiation exposure limits under normal or emergency conditions.
3.2 1
3.7 72 2.3. 12 Knowledge of radiological safety principles pertaining to licensed operator duties, such as containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.
3.2 1
3.7 73 2.3. 14 Knowledge of radiation or contamination hazards that may arise during normal, abnormal, or emergency conditions or activities.
3.4 1
3.8 2.3.
2.3.
Subtotal 3
1 99 2.4. 40 Knowledge of SRO responsibilities in emergency plan implementation.
2.7 4.5 1
100 2.4. 44 Knowledge of emergency plan protective action recommendations.
2.4 4.4 1
74 2.4. 49 Ability to perform without reference to procedures those actions that require immediate operation of system components and controls.
4.6 1
4.4 75 2.4. 20 Knowledge of the operational implications of EOP warnings, cautions, and notes.
3.8 1
4.3 2.4.
2.4.
Subtotal 2
2 10 7
K/A #
ES-401, Page 26 of 33 Tier 3 Point Total
- 3.
Radiation Control
- 4.
Emergency Procedures
/ Plan
- 2.
Equipment Control RO SRO-Only Category Topic
- 1.
Conduct of Operations