Category:Report
MONTHYEARML17083A9832017-03-22022 March 2017 Orau Independent Confirmatory Survey Summary, Results, and In-Process Inspection for the Interim On-Site Storage Building and Surrounding Area at the Rancho Seco Nuclear Generating Station ML17065A0342017-02-28028 February 2017 Final Status Survey Summary Report ML17065A0602017-02-24024 February 2017 Final Status Survey Summary Report, January 25, 2017, Iosb Embedded Pipe, Survey Unit F8300123 ML17065A0612017-02-0909 February 2017 Final Status Survey Summary Report, January 25, 2017, Iosb Loading Dock, Survey Unit F8300071 ML17065A0712017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Hot Cell Pipe, Survey Unit F8300111 ML17065A0722017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Office Area, Survey Unit F8300133 ML17065A0702017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Truck Bay, Survey Unit F8300053 ML17065A0682017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 2, Survey Unit F8300142 ML17065A0632017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Main Sump, Survey Unit F8300103 ML17065A0662017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 3, Survey Unit F8300143 ML17065A0552017-01-30030 January 2017 Final Status Survey Summary Report, December 27, 2016, Iosb Cell Deck, Survey Unit F8300093 ML17065A0652017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017 Iosb Hot Cell Class 2, Survey Unit F8300062 ML17065A0642017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Hot Cell, Survey Unit F8300061 ML17065A0692017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 1, Survey Unit F8300141 ML17065A0472017-01-30030 January 2017 Final Status Survey Summary Report, October 3, 2016, Iosb Roof, Survey Unit F8300153 ML17065A0582017-01-26026 January 2017 Final Status Survey Summary Report, January 6, 2017, Iosb Cask Wash Down Area, Survey Unit F8300323 ML17065A0462017-01-26026 January 2017 Final Status Survey Summary Report, October 21, 2016, Iosb Exterior Surfaces, Survey Unit F8300313 ML17065A0562017-01-24024 January 2017 Final Status Survey Summary Report, December 28, 2016, Iosb DAW Staging Bay, Survey Unit F8300023 ML17065A0592017-01-10010 January 2017 Final Status Survey Summary Report, January 6, 2017, Iosb DAW Staging Bay Class 2, Survey Unit F8300042 ML17065A0572017-01-10010 January 2017 Final Status Survey Summary Report, January 5, 2017, Iosb DAW Staging Bay Class 1, Survey Unit F8300031 ML17065A0482017-01-0404 January 2017 Final Status Survey Summary Report, November 7, 2016, Iosb Storage Cell B-3, Survey Unit F8300213 ML17065A0372016-12-30030 December 2016 Final Status Survey Report, October 20, 2016, Iosb Storage Cell A-3, Survey Unit F8300183 ML17065A0542016-12-29029 December 2016 Final Status Survey Summary Report, December 13, 2016, Iosb Storage Cell E-3, Survey Unit F8300303 ML17065A0532016-12-22022 December 2016 Final Status Survey Summary Report, December 12, 2016, Iosb Storage Cell D-3, Survey Unit F8300273 ML17065A0522016-12-15015 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell C-3, Survey Unit F8300243 ML17065A0512016-12-14014 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell D-2, Survey Unit F8300263 ML17065A0492016-12-14014 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell E-2, Survey Unit F8300293 ML17065A0352016-11-23023 November 2016 Final Status Survey Report, September 26, 2016, Iosb Storage Cell B-2, Survey Unit F8300203 ML17065A0402016-11-17017 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell B-1, Survey Unit F8300193 ML17065A0412016-11-14014 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell C-1, Survey Unit F8300223 ML17065A0362016-11-10010 November 2016 Final Status Survey Report, October 14, 2016, Iosb DAW Bay, Survey Unit F8300013 ML17065A0382016-11-0808 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell A-1, Survey Unit F8300163 ML16208A1092016-07-14014 July 2016 Sacramento Municipal Utility District (Smud), Rancho Seco Independent Spent Fuel Storage Installation (ISFSI) - Submittal of Biennial Report for May 2014 - April 2016 ML14310A1972014-10-30030 October 2014 Biennial Update to Rancho Seco License Termination Plan ML14219A3272014-07-24024 July 2014 Biennial Report ML14099A2572014-03-31031 March 2014 Report on Irradiated Fuel Management Funding Status ML12321A0302012-11-0505 November 2012 Radioactive Material Storage and Decommissioning Safety Analysis Report Amendment 1 ML12165A4722012-05-31031 May 2012 and Independent Spent Fuel Storage Installation - Biennial Report for the Period May 1, 2010 Through April 30, 2012 ML0920502152009-07-21021 July 2009 Confirmatory Survey Report for Activities Performed in the Industrial Area of the Rancho Seco Nuclear Generating Station ML0914701032009-05-0707 May 2009 Confirmatory Survey Report for September and October 2008 at the Rancho Seco Nuclear Generation Station by Oak Ridge Institute for Science and Education (Orise) ML0913504682009-05-0606 May 2009 Confirmatory Survey Report for the Rancho Seco Nuclear Generating Station Containment Building by Oak Ridge Institute for Science and Education (Orise) ML0912805482009-04-30030 April 2009 Draft Confirmatory Survey Report for the Rancho Seco Containment Building by Oak Ridge Institute for Science and Education (Orise) ML0904805822008-08-29029 August 2008 Confirmatory Survey Results for Activities Performed in April and May 2008 for the Rancho Seco Nuclear Generating Station ML0814903302008-05-19019 May 2008 Independent Spent Fuel Storage Installation - Biennial Report for the Period May 1, 2006 Through April 30, 2008 ML0905100292008-03-12012 March 2008 Confirmatory Survey Results for Activities Performed in December 2007, Rancho Seco Nuclear Generating Station ML0734505732007-12-0707 December 2007 Confirmatory Survey Report for Portions of the Auxiliary Building Structural Surfaces and Turbine Building Embedded Piping, Dated December 7, 2007 ML0715203992007-05-30030 May 2007 Fy 2007 Final Fee Rule Workpapers ML0622203512006-08-0303 August 2006 Historical Site Assessment, Revision 1 ML0614600982006-04-30030 April 2006 License Termination Plan, Rev 0, Table of Contents ML0614302132006-04-30030 April 2006 Sacramento Municipal Utility District Rancho Seco Nuclear Generating Station License Termination Plan, Rev. 0. Chapter 2 - Site Characterization to Chapter 5 - Final Status Survey Plan 2017-03-22
[Table view] Category:Technical
MONTHYEARML17065A0342017-02-28028 February 2017 Final Status Survey Summary Report ML17065A0602017-02-24024 February 2017 Final Status Survey Summary Report, January 25, 2017, Iosb Embedded Pipe, Survey Unit F8300123 ML17065A0612017-02-0909 February 2017 Final Status Survey Summary Report, January 25, 2017, Iosb Loading Dock, Survey Unit F8300071 ML17065A0712017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Hot Cell Pipe, Survey Unit F8300111 ML17065A0722017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Office Area, Survey Unit F8300133 ML17065A0702017-02-0101 February 2017 Final Status Survey Summary Report, February 1, 2017, Iosb Truck Bay, Survey Unit F8300053 ML17065A0682017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 2, Survey Unit F8300142 ML17065A0632017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Main Sump, Survey Unit F8300103 ML17065A0662017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 3, Survey Unit F8300143 ML17065A0552017-01-30030 January 2017 Final Status Survey Summary Report, December 27, 2016, Iosb Cell Deck, Survey Unit F8300093 ML17065A0652017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017 Iosb Hot Cell Class 2, Survey Unit F8300062 ML17065A0642017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Hot Cell, Survey Unit F8300061 ML17065A0692017-01-30030 January 2017 Final Status Survey Summary Report, January 30, 2017, Iosb Outside Area Class 1, Survey Unit F8300141 ML17065A0472017-01-30030 January 2017 Final Status Survey Summary Report, October 3, 2016, Iosb Roof, Survey Unit F8300153 ML17065A0462017-01-26026 January 2017 Final Status Survey Summary Report, October 21, 2016, Iosb Exterior Surfaces, Survey Unit F8300313 ML17065A0582017-01-26026 January 2017 Final Status Survey Summary Report, January 6, 2017, Iosb Cask Wash Down Area, Survey Unit F8300323 ML17065A0562017-01-24024 January 2017 Final Status Survey Summary Report, December 28, 2016, Iosb DAW Staging Bay, Survey Unit F8300023 ML17065A0592017-01-10010 January 2017 Final Status Survey Summary Report, January 6, 2017, Iosb DAW Staging Bay Class 2, Survey Unit F8300042 ML17065A0572017-01-10010 January 2017 Final Status Survey Summary Report, January 5, 2017, Iosb DAW Staging Bay Class 1, Survey Unit F8300031 ML17065A0482017-01-0404 January 2017 Final Status Survey Summary Report, November 7, 2016, Iosb Storage Cell B-3, Survey Unit F8300213 ML17065A0372016-12-30030 December 2016 Final Status Survey Report, October 20, 2016, Iosb Storage Cell A-3, Survey Unit F8300183 ML17065A0542016-12-29029 December 2016 Final Status Survey Summary Report, December 13, 2016, Iosb Storage Cell E-3, Survey Unit F8300303 ML17065A0532016-12-22022 December 2016 Final Status Survey Summary Report, December 12, 2016, Iosb Storage Cell D-3, Survey Unit F8300273 ML17065A0522016-12-15015 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell C-3, Survey Unit F8300243 ML17065A0492016-12-14014 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell E-2, Survey Unit F8300293 ML17065A0512016-12-14014 December 2016 Final Status Survey Summary Report, December 1, 2016, Iosb Storage Cell D-2, Survey Unit F8300263 ML17065A0352016-11-23023 November 2016 Final Status Survey Report, September 26, 2016, Iosb Storage Cell B-2, Survey Unit F8300203 ML17065A0402016-11-17017 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell B-1, Survey Unit F8300193 ML17065A0412016-11-14014 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell C-1, Survey Unit F8300223 ML17065A0362016-11-10010 November 2016 Final Status Survey Report, October 14, 2016, Iosb DAW Bay, Survey Unit F8300013 ML17065A0382016-11-0808 November 2016 Final Status Survey Report, October 21, 2016, Iosb Storage Cell A-1, Survey Unit F8300163 ML0920502152009-07-21021 July 2009 Confirmatory Survey Report for Activities Performed in the Industrial Area of the Rancho Seco Nuclear Generating Station ML0914701032009-05-0707 May 2009 Confirmatory Survey Report for September and October 2008 at the Rancho Seco Nuclear Generation Station by Oak Ridge Institute for Science and Education (Orise) ML0913504682009-05-0606 May 2009 Confirmatory Survey Report for the Rancho Seco Nuclear Generating Station Containment Building by Oak Ridge Institute for Science and Education (Orise) ML0622203512006-08-0303 August 2006 Historical Site Assessment, Revision 1 ML0520202442005-07-13013 July 2005 Decommissioning Technical Basis Document ML0233803882002-11-26026 November 2002 Defueled Safety Analysis Report, Amendment 5 NRC Generic Letter 1979-451979-09-25025 September 1979 NRC Generic Letter 1979-045: Transmittal of Reports Regarding Foreign Reactor Operation Experiences 2017-02-09
[Table view] |
Text
...
Rancho Seco
_f.irial Status Survey Summary Report October 21, 2016 IOSB Exterior Surfaces Survey Unit F8300313 Approved By:
FINAL STATUS SURVEY F8300313 Survey Unit:
F8300313, Interim Onsite Storage Building (IOSB) Exterior Surfaces Survey Unit
Description:
Operating History: Designed primarily to store packaged radioactive waste containers safely, protected from the elements, and maintain radiological dose as low as reasonably achievable (ALARA), the IOSB's storage cells possibly stored media of many types, including filters, resins, contaminated chemicals, DAW, activated reactor components, contaminated plant components and other contaminated items. This survey unit is the vertical exterior surfaces of the IOSB excluding the roof area.
Site Characterization: Section 5.2.2 of MARSSIM identifies the historical site assessment (HSA) data and professional judgment to be used for the evaluation of potential for residual contamination. Based on this evaluation of the IOSB exterior (vertical only) surfaces and the minimal potential for contamination, this survey unit was designed for final status and the area was designated as a Class 3 area.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table 1. The survey unit and measurement locations are depicted on the maps in Attachment 1. Static measurement locations were randomly determined and approximately 1% of the area scanned. The instrumentation used for the survey along with the MDC values are listed in Table 2-1Attachment2.
FSS Exterior Surfaces F8300313
FINAL STATUS SURVEY F8300313 I
Table 1, Survey Unit Design Parameters
- .* * :: *:*:,Eya*lµatiQ'iJ *lf:i"i>utvafoe:$ * *"
.*~:omril~r:its; * ,
':*:~,[
~ !*~
Survey Packaqe: F830 IOSB Exterior Surfaces Survey Unit: 031 Class 3 SU Area (m2) 2750
(::valuator: EG DCGLw: 43,000 Gross Activity DCGL Area Factor NIA Class 3 Design DCGLemc (dpml100cm 2 ): NIA Class 3 DCGLemc: NIA Class 3 LBGR: 21,500 Default = 50% DCGL Sigma: 175 Survey Data Type I error: 0.05 Type 11 error: 0.05 Predominant Nuclide Cs-137 Sample Area (m2) NIA Total Instrument l;fficiencv: 0.129 Total Area Scanned (m2): 27.7 Scan Coverage(%) *.':.J::;::MM, Class 3 Choosing 'NIA' sets material Material Type: NIA background to "O"
- ~
- ;;:::.:.*.**.:t'.:*;.:*~, 'ca.1~*u1ai~~-.V~iue~'.:* *!:*:'\. . . .,.;-:::::*:Y -<.:(>?/;~;;~~":*;:~c<>ilwn~ilts . <*; ;* . * ..
Z1-a: 1.645 Z1-a: 1.645 Sign p: 0.99865 Calculated Relative Shift: 122.8 Relative Shift Used: 3.0 Uses 3.0 if Relative Shift >3 N-Value: 11 N-Value+20%: 14 2 FSS Exterior Surfaces F8300313
FINAL STATUS SURVEY F8300313 Survey Results:
A total of 15 direct measurements were made in F83 00313. The results of the static measurements are shown in Table 2. All of the static measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. Swipe data was not obtained in this survey unit, therefore no swipe data is included in Attachment 4.
Table 2, Static Measurement Results Number I Sample# Beta (cpm) Beta.(dpm) 1 F8300313C00001 305 2,364 2 F8300313C00002 259 2,008 3 F8300313C00003 284 2,202 4 F8300313C00004 220 1,705 5 F8300313C00005 272 2,109 6 F8300313C00006 268 2,078 7 F8300313C00007 268 2,078 8 F8300313C00008 290 2,248 9 F8300313C00009 252 1,953 10 F8300313C00010 268 2,078 11 F8300313COOO 11 267 2,070 12 F8300313COOO 12 270 2,093 13 F8300313C00013 249 1,930 14 F8300313C00014 293 2,271 15 F8300313COOO 15 307 2,380 Table 3 contains the statistical summary of the static measurement data for the Exterior Surfaces Table 3, Beta Summary Statistics Beta Static Exterior Surfaces Mean 2,104 Median 2,078 Standard Deviation 175 Minimum 1,705 Maximum 2,380 Count 15 3 FSS Exterior Surfaces F8300313
FINAL STATUS SURVEY F8300313 Survey Unit Data Assessment:
The survey design required 14 static measurements for the Sign Test. A total of 15 static measurements were collected. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL.
Table 4, Data Assessment Results
... *Cohirnerit~
Number of Samples: 15 Median: 2,078 Mean: 2,104 Static Data Standard Deviation: 175 Maximum:
Adjusted N Value: 14 S+ Value: 15 Critical Value:
- . *...c<>.mrn~ht~ * * ; * '! .. '
Sufficient samples collected: Pass Maximum value <DCGLw: Pass Median value <DCGLw: Pass Mean value <DCGLw: Pass Maximum value <DCGLemc: .
- N/A Sic::in test results: . Pass The survev unit passes all conditions: Pass*
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL, the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 3 survey and the sample results are consistent with that classification. No potential areas of elevated activity were detected.
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 3 survey based on the scoping evaluation. The required number of direct measurements was made and the scan 4 FSS Exterior Surfaces F8300313
FINAL STATUS SURVEY F8300313 coverage met the requirement of Table 5-6 of the LTP. All of the static measurements were less than the DCGL. No investigations were required.
The static measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F83003 l 3 meets the release criteria of 10CFR20.l402.
5 FSS Exterior Surfaces F8300313
Attachment 1 Maps October 21, 2016 Survey Unit F8300313
F8300313C00010 J3 =2,078 dpm/100 cm 2 E17 F8300313C00012 F83003.~ 3C00003 Ei F8300313C00004
,*' i '
J3 =2,093 dpm/100 cm 2 J3 =2,202 dpm/100 cm 2 J3 =1,705 dpm/100 cm 2 I
I
~
F8300313C00009 I
J3 = 1, 953 dpm/100 cm 2 HS300313C00005
_,. p :::i2, 109 dpm/100 cm 2
~ F8300313C00006 J3 =2,078 dpm/100 cm 2 F8300313C00015
) J3 =2,380 dpm/100 cm 2 l'1' F8300313C00002 F8300313C00007 F8300313C00014 '
J3 =2,008 dpm/100 cm 2 J3 =2,078 dpm/100 cm2 J3 =2,271 dpm/100 cm 2
'J:) IT\
'1.1
~
IT\
'1.1 ""
F8300313C00001 F8300313COOO 11 F8300313C00013 J3 =2,364 dpm/100 cm 2
- J3 =2,070 dpm/100 cm2 F8300313C00008 J3 =1,930 dpm/100 cm 2 J3 =2,248 dpm/100cm2 1058 ExTERIOR SURFACES Contract No.: 4500091426 SMUD
~L~oc~oti~on::_:--i:R:::,:an:.::,ch:.:'.._o,::.::Se.:.::co_ _ _--1 Approved by.
Task: Final Status Drawing No.: . IOSB Final Status Surve
Description:
IOSB Exterior Drown B .
- c ra QC'd: . J Reese Approval dote:
Dote: 10062016 Page 1 Att. 1 Maps F8300313 Rev No.: 1
Attachment 2
'Instrumentation October 21, 2016 Survey Unit *F8300313
Table 2-1. Survey Unit Instrumentation
- M:easu,reijient Miniintim DetectabteActlvity". Dete,ctcir C.ali!>ration
.* Type
.. T~r.e '*: . . ., Efficief!cies,. . 'Due l)a.~eb Beta Static Ludlum Model 2350-1 Beta - 500 dpm/100 cm 2 12.9% 317899/331973 Measurement Ludlum Model 2/10/17 44-116 B Detector
- Minimum detectable activities for the count rate instrumentation were calculated in accordance with NUREG-1507, "Minimum Detectable Concentrations with Typical Radiation Survey Instruments for Various Contaminants and Field Conditions" (U.S. NRC, 1997).
b Detectors are required to be calibrated once every 12 months. Calibration due date indicates the date by which the detector must be calibrated again.
cm 2 = square centimeters cpm =counts per minute dpm =disintegrations per minute Page 1 Att. 2 Instrumentation F8300313
Static Measurement MDA Variables Beta Survey Type 331973 Detector Number 175 Background count rate (cpm) 1 Count Time (min) 0.129 Efficiency 100 Area of Detector (cm 2)
Constants 60 sec/min 2.54 cm/in Assumptions Background count time and sample count time are equivalent Calculate Static MDA Static MDA =3 + 4.65(Br
Background
Where: Br Countrate t Count Time (min)
E Efficiency A Area of detector (cm2)
Static MDA 500 dpm/100 cm 2 Page 2 Att. 2 Instrumentation F8300313
Attachment 3 Investigation October 21, 2016 Survey Unit F8300313 (none required)
Attachment 4 Data Assessment October 21, 2016 Survey Unit F8300313
Histogram for Beta Direct Activity (dpm/100cm2) lOSB Exterior Surfaces IActivity Nun- ~r of Valu~s r r. .linimun*
M~xjn*um so 1.705A~
£.379.&'.
7'1 . ~
Ske~-r e:ss -0 . ~1 Kurtosis 0.791 B Meo 2.10' 391 B Mo::1iar 2.07752 5
B Mcrn*:I Distribution O L~s Bm>
0 Mere E.in>
821 1888 1?56 2023 Dato R-> n;;e
£091 2158
- ms 2293 £360 Page 1 Att. 4 Data Assessment F8300313
Q-Q Plot for Beta Direct Activity (dpm/100cm2) IOSB Exterior Surfaces Aclivily N =.15
&*174.5 Slope= 177.5 2300 Intercept= 2104 Correlatior" R =0.971 l!I BeorFit Line 220()
1700 *
-i.5 -1.0 -0.5 0.0 0.5 1.v i.5 Theoretical Quantiles (Standard Normal)
Page 2 Art. 4 Data Assessment F8300313