ML17059C122

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-220/98-05 & 50-410/98-05 on 980412-0523 & Nov.One Violation Involved Failure to Follow Containment Spray Raw Water Surveillance Test Procedure
ML17059C122
Person / Time
Site: Nine Mile Point  
Issue date: 07/07/1998
From: Doerflein L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mueller J
NIAGARA MOHAWK POWER CORP.
Shared Package
ML17059C123 List:
References
50-220-98-05, 50-220-98-5, 50-410-98-05, 50-410-98-5, NUDOCS 9807140049
Download: ML17059C122 (8)


See also: IR 05000220/1998005

Text

CATEGORY

2

REGULATORY 1NFORMAT1ON D1STRIBUTION SYSTEM (RIDS)

Nj

ACCESSION NBR:9807140049

DGC.DATE: 98/07/07

NOTARIZED: NO

DOCKET

FACIL:50-220 Nine Mile Point Nuclear Station, 'Unit 1, Niagara

Powe

05000220

~

~

~

~

50-410 Nine Mile Point Nuclear Station, Unit 2, Niagara Moha'5000410

UTH.NAME

AUTHOR AFFILIATION

OERFLEIN,L.T.,

Region

1 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

MUELLER,J.H.

Niagara

Mohawk Power Corp.

SUBJECT: Forwards insp repts

50-220/98-05

Sc 50-410/98-05

on

980412-0523

& NOV.One violation involved failure to follow

containment

spray raw water surveillance test procedure.

DISTRIBUTION CODE: IEOIF

COPIES

RECEIVED:LTR 3

ENCL

(

SIZE: 3 6

TITLE: General

(50 Dkt)-Insp Rept/Notice of Violation Response

NOTES:

3 I

RECIPIENT

ID CODE/NAME

PD1-1

PD

INTERNAL: ACRS

8

FI E CENTER

/DRY/ ECB

NUDOCS-ABSTRACT

OGC/HDS3

RNAL: LITCO BRYCE,J H

NRC PDR

COP1ES

LTTR ENCL

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

HOOD,D

AEOD/SPD/RAB

DEDRO

NRR/DRCH/HOHB

NRR/DRPM/PERB

OE DIR

RGN1

FILE'1

NOAC

NUDOCS FULLTEXT

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

.1

1

1

1

1

1

D

, LGAGED FRag

i Mac zt.oppy

NOTE TO ALL "RZDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS

OR REDUCE THE NUMBER OF COPZES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL

DESK

(DCD)

ON EXTENSION 415-2083

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

19

ENCL

19

l

~i

0

July 7, 1998

Mr. John H. Mueller

Chief Nuclear Officer

Niagara Mohawk Power Corporation

Nine Mile Point Nuclear Station

Operations Building, 2nd Floor

P.O. Box 63

Lycoming, NY 13093

SUBJECT'RC INSPECTION REPORT NOS. 50-220/98-05AND 50-410/98-05

AND NOTICE OF VIOLATION

Dear Mr. Mueller:

t

This report transmits the findings of safety inspections conducted by NRC inspectors at the

Nine Mile Point Nuclear Station, Units

1 and 2, from April 12 through May 23, 1998. At

the conclusion of the inspection, the findings were discussed with you, and members of

your staff.

During this period, your staff operated both units safely.

Our review of the root cause

investigation for the dropped double blade guide at Unit 2 found it to have been thorough.

We consider the continuing identification of old design issues by your staff as representing

a responsible questioning attitude with respect to challenging and enhancing the

plants'esign

bases.

However, based on the results of this inspection, the NRC has determined that violations

of NRC requirements occurred.

These violations are cited in the enclosed Notice of

Violation (Notice) and the circumstances

surrounding them are described in detail in the

subject inspection report.

Specifically, the violations involved:

(1) the failure to follow the

containment spray raw water surveillance test procedure;

(2) the failure to conduct a

service test on the Division I battery at Unit 2; (3) the failure to properly implement a

modification related to the installation of a new design for the emergency diesel generator

fuel supply piping; and, (4) the failure to include the wind speed sensor in the channel

calibration of the meteorological monitoring instrumentation.

The NRC has concluded that the information regarding the reason for violations (2) and (3)

above, the corrective actions taken and planned to correct these violations and to prevent

recurrence,

and the date when full compliance was achieved has been adequately docketed

via Licensee Event Report 50-410/98-09and

this inspection report.

Therefore, you are not

required to respond to these violations, unless the description in the enclosed report does

not accurately reflect your corrective actions or your position.

If you choose to provide

additional information, you should follow the instructions specified in the enclosed Notice.

For the remaining violations, you are required to respond to this letter and should follow

the instructions specified in the enclosed Notice when preparing your response.

The NRC

will use your response,

in part, to determine whether further enforcement action is

necessary to ensure compliance with regulatory requirements.

9807k 40049 980707

PDR

ADQCK 05000220

8

PDR

OFFICIAL RECORD

COPY

IE:01

John H. Mueller

2

The responses

directed by'this letter and the enclosed Notice are not subject to the

clearance procedures of the Office of Management and Budget as required by the

Paperwork Reduction Act of 1980, Pub. L. No. 96.511

~

In accordance with 10CFR2.790of the NRC's "Rules of Practice,"

a copy of this letter, its

enclosures,

and your response will be placed in the NRC Public Document Room.

Sincerely,

Original Signed

by:

Lawrence T. Doerflein, Chief

Projects Branch

1

Division of Reactor Projects

Docket Nos.

License Nos.

50-220, 50-41 0

DPR-63, NPF-69

Enclosures:

1. Notice of Violation

2.

NRC Inspection Report Nos. 50-220/98-05 and 50-410/98-05

cc w/enclosures:

G. Wilson, Senior Attorney

M. Wetterhahn, Winston and Strawn

J. Rettberg, New York State Electric and Gas Corporation

P. Eddy, Electric Division, Department of Public Service, State of New York

C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law

J. Vinquist, MATS, Inc.

F. Valentino, President, New York State Energy Research

and Development Authority

'.

Spath, Program Director, New York State Energy Research

and Development Authority

0

i

John H. Mueller

Distribution w/encl:

H. Miller, RA/W. Axelson, DRA (1)

Region

I Docket Room (with concurrences)

Nuclear Safety Information Center (NSIC)

PUBLIC

NRC Resident Inspector

L. Doerflein, DRP

B. Cook, DRP

R. Junod, DRP

Distribution w/encl: (VIAE-MAIL)

B. McCabe, Rl EDO Coordinator

B. Norris - Nine Mile Point

S. Bajwa, NRR

D. Hood, NRR

M. Campion, Rl

Inspection Program Branch (IPAS)

R. Correia, NRR

F. Talbot, NRR

DOCDESK

DOCUMENT NAME'ABRANCH1iNMPSTUFF>NMP9805.INS

To receive a copy of this document, indicate in the box: "C" = Copy without

attachment/enclosure

"E" = Copy with attachment/enclosure

"N" = No copy

OFFICE

Rl/DRP

NAME

BNorris

DATE

07/

/98

RI/DRP

LDoerflein

07/7 /98