~g RE00

~ (4 P

4 0

~

~

)

Cy A.0 a'4 O

D Q

~O

> ++*++

UNlTED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 22, 1995 Mr. B. Ralph Sylvia Executive Vice President, Nuclear Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093

SUBJECT:

NINE MILE POINT NUCLEAR STATION UNIT NO.

1 (NMPl), DENIAL OF AMENDMENT REQUEST FOR CHANGE TO PLANT TECHNICAL SPECIFICATIONS REGARDING PRESSURE/TEMPERATURE LIMITS (TAC NO. M90288)

Dear Mr. Sylvia:

The purpose of this letter is to transmit. our safety evaluation (SE) of the subject matter.

We have concluded that the technical basis provided in your submittal does not support the proposed changes.. Accordingly, your amendment-request cannot be approved.

In a letter dated September 1,

1994, as supplemented December 5 and 20,
1994, you requested approval to revise the pressure/temperature (P/T) limits in the Technical Specifications, Section 3.2.2.

The figures.and tables in this section define the limits for minimum reactor vessel temperature for pressurization, and account for neutron damage at exposures up to 18 effective full power years of operation.

The proposed new P/T limits were determined using a proposed Charpy shift (embrittlement) model that has no reactor vessel material chemistry dependence.

The NRC staff has completed its review of the license amendment proposed in your letter of December 5,

1994.

For the reasons given below, the amendment request is denied.

The proposed standard deviation in the data is nonconservative and not derived from an analysis of the data.

2.

3.

4.

5.

The data used in the analysis do not support the proposed conclusions.

The contention that copper plays a minor role in neutron embrittlement conflicts with other data and studies, including NUREG/CR-6231 and NUREG/CR-2948.

The proposed model does not bound the copper content of the limiting vessel beltline material.

The proposed model is based on a relatively small number of data points.

0 6 Qoq

"~

9509280112 950922 PDR ADQCK 05000220 P

PDR

1

.B. Sylvia Additional details of our review and the basis for the staff's conclusions are provided in the enclosed SE.

A copy of the Notice of Denial of Amendment to be published in the Federal

~Re ister is enclosed for your infornation.

By this letter we are closing TAG No. H90288.

guestions may be directed to the Licensing Project Hanager, Dr. Gordon E. Edison, at 301-415-1448.

Sincerely, Docket No. 50-220 Gordon E. Edison, Senior Project Hanager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosures:

1.

Safety Evaluation 2.

Notice of Denial cc w/encls:

See next page

0 1

B. Ralph Sylvia Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Unit No.

1 CC:

Hark J. Wetterhahn, Esquire Winston

5. Strawn 1400 L Street, NW Washington, DC 20005-3502 Supervisor Town of Scriba Route 8, Box 382
Oswego, NY 13126 Hr. Richard B. Abbott Vice President Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Resident Inspector U.S. Nuclear Regulatory Commission P.O.

Box 126

Lycoming, NY 13093 Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, NY 13202 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Hr. F. William Valentino, President New York State
Energy, Research, and Development Authority 2 Rockefeller Plaza
Albany, NY 12223-1253 Mr. Norman l.

Rademacher Unit 1 Plant Manager Nine Nile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093 Ms. Deni se J. Wolniak Manager Licensing Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63 Lycoming,.NY 13093 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. Paul D. Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza

Albany, NY 12223 Hr. Hartin J. McCormick, Jr.

Vice President Nuclear Safety Assessment and Support Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station P.O.

Box 63

Lycoming, NY 13093

0 I