ML17056B105

From kanterella
Jump to navigation Jump to search

Forwards Summary of NRC Staff Understanding of Current Status of Unimplemented Generic Safety Issues at Plant
ML17056B105
Person / Time
Site: Nine Mile Point  Constellation icon.png
Issue date: 11/09/1990
From: Martin R
Office of Nuclear Reactor Regulation
To: Burkhardt L
NIAGARA MOHAWK POWER CORP.
References
TAC-75993, NUDOCS 9011150111
Download: ML17056B105 (8)


Text

I p

L November 9,

.390 Docket Nos. 50-220 and 50-410 Mr. Lawrence Burkhardt III Executive Vice President - Nuclear Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212 Distribution PDI-1 Reading BBoger REMartin EJordan RACapra Plant file NRC 8 Local PDRs SVarga CVogan DOudinot ACRS (10)

JLinville RScholl DMiller

Dear Mr. Burkhardt:

SUBJECT:

UNIMPLEMENTED GENERIC SAFETY ISSUES AT NINE MILE POINT UNIT 1 AND UNIT 2 (TAC NO. 75993)

On April 25, 1990, the staff issued Generic Letter 90-04 which requested infor-mation concerning the implementation status of certain generic safety issues (GSIs) at your facility.

Based on your response to this Generic Letter, dated June 26, 1990, our own records and discussions with your staff, we have updated our database on GSI implementation status.

The results of this effort were presented to the Commission at a meeting on October 25, 1990.

The enclosure to this letter summarizes the staff's understanding of the current status of those GSIs which remain unimplemented at Nine Mile Point Unit 1 and Unit 2.

We appreciate the assistance you provided in responding to Generic Letter 90-04 and we encourage your timely completion of those GSIs listed in the enclosure.

Please contact me if you have any questions or comments about the enclosed information.

Sincer ely,

Enclosure:

As stated cc w/enclosure:

See next page

.5R151NAI. SIGNED 9YI Robert E. Martin, Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation PDI-1: LA CVogan ff/g /90

+-1: PE DOudinot

)/ / 1/90 por-z:os/

a tin:avl RACapraA iI /Pf/90

<r/q/98 DOCUMENT NAME: NMP1/2 GSI LTR 75993 90iii50>XZ 90>~09 POR

  • DOCK 05000220 P

pvu pot

'a H

E

~

~

tl II lb

~ '

~g hEttti n0 D 4 vl i7 (4

0p*y4 Docket Nos. 50-220 and 50-410 t

g(o." I~"g'P, jI'"

t NUCLEAR REGULATORY COMMISS(ON WASHINGTON, D. C. 20555 November 9, 1990 Mr. Lawrence Burkhardt III Executive Vice President - Nuclear Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Burkhardt:

SUBJECT:

UNIMPLEMENTED GENERIC SAFETY ISSUES AT NINE MILE POINT UNIT 1 AND UNIT 2 (TAC NO. 75993)

On April 25, 1990, the staff issued Generic Letter 90-04 which requested infor-mation concerning the implementation status of certain generic safety issues (GSIs) at your facility.

Based on your response to this Generic Letter, dated June 26, 1990, our own records and discussions with your staff, we have updated our database on GSI.implementation status.

The results of this effort were presented to the Commission at a meeting on October 25, 1990.

The enclosure to this letter summarizes the staff's understanding of the current, status of those GSIs which remain unimplemented at Nine Mile Point Unit 1 and Unit 2.

We appreciate the assistance you provided in responding to Generic Letter 90-04 and we encourage your timely completion of those GSIs listed in the enclosure.

Please contact me if you have any questions or comments about the enclosed information.

Sincerely,

Enclosure:

As stated Robert E. Martin, Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation cc w/enclosure:

See next page

ENCLOSURE UNIMPLEMENTED GSIs AT NINE MILE POINT UNITS 1 AND 2 RSI MO.

43 51 67.3.3 TITLE Reliability of Air Systems Improving the Relia-bility of Open-Cycle Service Water Systems Improved Accident Monitoring PROJECTED IMPLEMENTATION

~

DATE Unit 1 - Winter 92/93 (end of cycle 10 RO)

Unit 2 - Winter 90/91 (end of cycle 1 RO)

Unit 1 - Winter 92/93 (end of cycle 10 RO)

Unit 2 - Fall 92 (end of cycle 2

RO)

To Be Determined REMARKS Will be completed during next refueling outage (RO) for Unit 1 and current refueling outage for Unit 2.

Licensee has been requested to reconsider the recommendations of GL 89-13 and submit a revised response for Units 1 5 2.

Neutron flux monitoring issue remains open for Units 1 and 2.

Responses to issues arising from inspection audit at Unit 1 are under review by the staff.

75 Salem ATWS Item 2.2.2, Unit 1 and 2

Vendor Interface for Winter 91/92 Safety-Related Components Program under development.

~

~

Mr. Lawrence Burkhardt, III Nine Mile Point 1/2

'Niagara Mohawk Power Corporation Mr. Mark J. Wetterhahn, Esquire

Bishop, Cook, Purcell 5 Reynolds 1400 L. Street, N.W.

Washington, D. C. 20005-3502 Supervisor Town of Scriba R.

D.

P4

Oswego, New York 13126 Mr. Joseph F. Firlit Vice President - Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
Lycoming, New York 13093 I

Resident Inspector U. S. Nuclear Regulatory Comoission Post Office Box 126

Lycoming, New York 13093 Mr.

Kim Dahlberg Unit 1 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 32

'ycoming, New York 13093 Mr. Richard Abbott Unit 2 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 32

Lycoming, New York 13093 Charlie Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Mr. Paul D. Eddy State of New York Department of

'ublic Service Power Division, System Operations 3 Empire State Plaza

Albany, New York 12223 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Mr. Peter E. Francisco, Licensing Niagara Mohawk Power Corporation 301 Plainfield Road
Syracuse, New York 13212 Regional Administrator, Region I U. S. Nuclear Regulatory Comnission 475 Allendale Road King of Prussia, Pennsylvania 19406 Mr. Richard Goldsmith Syracuse University College of Law E. I. White Halle Campus
Syracuse, New York 12223 Ms.

Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor

Albany, New York 12223 Mr. Richard M. Kessel Chair and Executive Director State Consumer Protection Board 99 Washington Avenue
Albany, New York 12210

r

~

~