October I
1990 Docket No. 50-220 Mr. Lawrence Burkhardt III Executive Vice President, Nuclear Operations Niagara Mohawk Power Corporation 301 Plainfield Road
- Syracuse, New York 13212 Distribution:
PDI-1 Reading NRC/Local PDRs SVarga BBoger CVogan REMartin DOudinot OGC EJordan ACRS(10)
Plant File RCapra JLinville HShaw pg;~K,n ~
Dear Mr. Burkhardt:
SUBJECT:
CLOSEOUT OF IE BULLETIN 79-15, "DEEP DRAFT PUMP DEFICIENCY,"
FOR NINE MILE POINT UNIT 1 (TAC NO. 71164)
By letter dated December 12, 1989, Niagara Mohawk Power Corporation, the
- licensee, responded to an October 12, 1989, letter by the staff requesting additional information for the closeout of IE Bulletin 79-15, "Deep Draft Pump Deficiencies."
The staff has reviewed the licensee's response and has concluded that for the four Worthington Core Spray Pumps and the two Worthington Emergency Service Water Pumps installed at Nine Mile Point 1, an adequate basis exists to resolve the safety concerns indentified in Bulletin 79-15.
The basis for this con-clusion is provided in the enclosed safety evaluation.
This completes all action with respect to TAC No. 71164.
Your cooperation in resolving this issue is appreciated.
Sincerely, ORIGINAI. SIGNED PY:
t Robert E. Martin, Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/enclosure:
See next page PDI-1: LA CV ga I~ tq gg P~:88
~ p D9<dinot: rsc EMar tin i /i<</~o
'/"I<
PDI-1:D RACapra I+/l8/$0 DOCUMENT NAME:
NMP1 LTR TO BURKHARDT 71164 9010300299 901018 PDR AGOCK 05000220 i
9 PDC
I
'Nl'
~ ~,'f Fc i
l'I
'l N
- i.'
4 i
p
(
)Irl I
4 I, I
4 I
r(t 4
1 i
I
<<4 )'>!4 Il
/ f4~ r rC v
fl44
. r>>
N
$ 44 Ilytl I 4
4 14N>>~
1
<<4p)
(s,f t,f i.t1U
I il c
kt n
,i ryfc a.i
. fJ 1.N.'I
'N
NIINJ<<1 I
"<<f,'
1
'cc
~
4 t!c 4 <<>>
ll ii,
'<1, 1yfi
'f)'4
"I 4,
~ iiy<< 1 I
4 r iII<<
)(4I'IL I II
';, ~ It N1 ll t illl NWI 4 4 '1'I',)
Ii 4 4"0 <<!>>yf t 1 t~.r 4,
(
4 i
'fi"<
4 II F;!
\\<<
I 4'I" <<A yl
'f3
<<y I
>>,I 4 tl I
Ii ~
il I g I ~14
~
14=,
4
P,A R~Cuc Wp.0 Gp 4u
+%*4+
Docket No. 50-220 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 October 18, 1990 Mr. Lawrence Burkhardt III Executive Yice President, Nuclear Operations Niagara Mohawk Power Corporation 301 Plainfield'Road
- Syracuse, New York 13212
Dear Mr. Burkhardt:
SUBJECT:
CLOSEOUT OF IE BULLETIN 79-15, "DEEP DRAFT PUMP DEFICIENCY,"
FOR NINE MILE POINT UNIT 1 (TAC NO. 71164)
By letter dated December 12, 1989, Niagara Mohawk Power Corporation, the
- licensee, responded to an October 12, 1989, letter by the staff requesting additional information for the closeout of IE Bulletin 79-15, "Deep Draft Pump Deficiencies."
The staff has reviewed the licensee's response and has concluded that for the four Worthington Core Spray Pumps and the two Worthington Emergency Service Water Pumps installed at Nine Mile Point 1, an adequate basis exists to resolve the safety concerns indentified in Bulletin 79-15.
The basis for this con-clusion is provided in the enclosed safety evaluation.
This completes all action with respect to TAC No. 71164.
Your cooperation in resolving this issue is appreciated.
Sincerely,
Enclosure:
Safety Evaluation cc w/enclosure:
See next page Ro ert artin, Senior Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Mr. L. Burkhardt III Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station, Unit No.
1 Mr. Mark J. Wetterhahn, Esquire Bishop, Cook, Purcell E Reynolds 1400 L. Street, N.W.
Washington, D.
C.
20005-3502 Supervisor Town 'of Scriba R.
D. 84
- Oswego, New York 13126 Mr. Joseph F. Firlit General Supt.-Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Resident Inspector U.S. Nuclear Regulatory Commission Post Office Box 126
- Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
- Syracuse, New York 13202 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Ms.
Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor
- Albany, New York 12223 Mr. Kim Dahlberg Unit 1 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 32
- Lycoming, New York 13093 Mr. Peter E. Francisco, Licensing Niagara Mohawk Power Corporation 301 Plainfield Road
- Syracuse, New York 13212 Charlie Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Mr. Paul D. Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza
- Albany, New York 12223