ML17056A353

From kanterella
Jump to navigation Jump to search

Requests Addl Listed Info Re Closeout of NRC Bulletin 79-15, Deep Draft Pump Deficiencies, Including Type of Pumps & Detailed Maint History
ML17056A353
Person / Time
Site: Nine Mile Point 
Issue date: 10/12/1989
From: Slosson M
Office of Nuclear Reactor Regulation
To: Burkhardt L
NIAGARA MOHAWK POWER CORP.
References
IEB-79-15, TAC-71164, NUDOCS 8910190289
Download: ML17056A353 (6)


Text

a October 12, 1989 Docket No. 50-220 Hr. Lawrence Burkhardt III Executive Vice President Nuclear Operations Niagara Hohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212 DISTRIBUTION Clrmfvn.D PDI-1 Rdg CVogan RCapra JWiggins DBrinkman DShaw HSlos son BBoger NRC 5 Local PDRs OGC EJordan SVarga BGrimes ACRS (10)

DOudinot

Dear Hr. Burkhardt:

SUBJECT:

RE(VEST FOR ADDITIONAL INFORHATION FOR CLOSEOUT OF IE BULLETIN 79-15 TAC NO. 71164 A review of our records indicates that IE Bulletin 79-15 "Deep Draft Pump Deficiencies,"

dated July 11, 1979, has not been closed out for the four Worthington core spray system pumps and two Worthington emergency service water pumps for your facility.

The following additional information is required for us to complete our review of this issue.

1.

The type and application of the pumps listed above.

2.

Drawings, sectional assemblies and parts list of the subject pumps.

3.

Applicable PEIDs of the subject pumps.

4.

Detailed maintenance history of the subject pumps.

5.

Testing requirements, procedures and results for both hydraulic and vibration parameters in recent years for the subject pumps.

Please provide this information within 60 days of the date of this letter.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents',

therefore, OHB clearance is not required under PL 96-511.

Sincer ely, Original signed by 3910190289'5'1012 PDR ADOCK 05000220 0

PDC Harylee H. Slosson, Project Hanager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

RCapra OFFICIAL RECORD COPY Document Name:

CLOSEOUT IE TAC 71164 w

w e

NAME:CVogan:D+Di68t/bah:MS tosson Q%QWW W

WWWW WWWWWW WW WW DATE:

(D g. fjN: /0 (g g):

W ~

~

W OWW WW

~ OWN

~

W&&

~

~

~

~

WWWW W

A tl I

~

I ld

~'I f

II fl

~k.

F

~

~ t~R REDO V~0*'

O ga gO

++*++

Docket No. 50-220 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 October 12, 1989 Mr. Lawrence Burkhardt III Executive Vice President Nuclear Operations Niagara Mohawk Power Corporation 301 Plainfield Road

Syracuse, New York 13212

Dear Mr. Burkhardt:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR CLOSEOUT OF IE BULLETIN 79-15'TAC NO. 71164)

A review of our records indicates that IE Bulletin 79-15 "Deep Draft Pump Deficiencies,"

dated July 11, 1979, has not been closed out for the four Worthington core spray system pumps and two Worthington emergency service water pumps for your facility.

The following additional information is required for us to complete our review of this issue.

1.

The type and application of the pumps listed above.

2.

Drawings, sectional assemblies and parts list of the subject pumps.

3.

Applicable P&IDs of the subject pumps.

4.

Detailed maintenance history of the subject pumps.

5.

Testing requirements, procedures and results for both hydraulic and vibration parameters in recent years for the subject pumps.

Please provide this information within 60 days of the date of this letter.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under PL 96-511.

Sincerely,

~P/~y~N Marylee M. S'losson, Project Manager Project Directorate I-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

r t'

> ~

Hr. I,. Burkhardt III Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station, Unit No.

1 cc Mr. Troy B. Conner, Jr., Esquire Conner 5 Wetterhahn Suite 1050 1747 Pennsylvania

Avenue, N.

W.

Washington, D. C.

20006 Supervisor Town of Scriba R. D. f4

Oswego, New York 13126 Hr. James L. Willis General Supt.-Nuclear Generation Niagara Mohawk Power Corporation Nine Mile Point Nuclear Station Post Office Box 32
Lycoming, New York 13093 Resident Inspector U. S. Nuclear Regulatory Comnission Post Office Box 126
Lycoming, New York 13093 Mr. Gary D. Wilson, Esquire Niagara Mohawk Power Corporation 300 Erie Boulevard West
Syracuse, New York 13202 Regional Administrator, Region I U. S. Nuclear Regulatory Commission 475 A11enda le Road King of Prussia, Pennsylvania 19406 Ms. Donna Ross New York State Energy Office 2 Empire State Plaza 16th Floor
Albany, New York 12223 Hr. Kim Dahlberg Unit 1 Station Superintendent Nine Mile Point Nuclear Station Post Office Box 32
Lycoming, New York 13093 Hr. Peter E. Francisco, Licensing Niagara Mohawk Power Corporation 301 Plainfield Road
Syracuse, New York 13212 Charlie Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Mr. Paul D. Eddy State of New York Department of Public Service Power Division, System Operations 3 Empire State Plaza
Albany, New York 12223

V

~.

~'~