Nuclear Operating Company South Texas Project Electric Generating Station l?O Box 289 Wadsworth. Texas 77483 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South Texas Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 February 9, 2017 NOC-AE-17003441 10 CFR 54 File No. G25 Reyised Response to Request for Additional Information for the Review of the South Texas Project License Renewal Application (CAC Nos. ME4936 and ME4937)
References:
- 1. Letter; G. T. Powell to the NRC Document Control Desk; "License Renewal Application",
NOC-AE-10002607; dated October 25, 2010. (ML103010257)
- 2. *Letter; From the NRC, Lois M. James to STP Nuclear Operating Company, G.T. Powell;.
"Request for Additional Information for the Review of the South Texas Project License Renewal Application (CAC Nos. ME4936 and ME4937)"; dated December 5, 2016.
- 3. Letter; From STP Nuclear Operating Company, Michael P. Murray to Lois M. James, NRC; "Extension Request for License Renewal Application Request for Additional Information (CAC Nos. ME4936 and ME4937)"; NOC-AE-17003431, dated January 3, 2017. (ML17017A209)
- 4. Letter; From STP Nuclear Operating Company, James Connolly to Lois M. James, NRC; "Request for Additional Information for the Review of the South Texas Project License
- Renewal Application (CAC Nos. ME4936 and ME4937)", NOC-AE-16003428,*dated January 12, 2017. (ML17025A087)
By Reference 1, STP Nuclear Operating Company (STPNOC) submitted a License Renewal Application (LRA). In Reference 2, the NRC requested additional information for the review of the South Texas Project License Renewal Application. In Reference 3, STPNOC requested additional time for responding to the request for additional information (RAI) in Reference 2. In Reference 4, STPNOC submitted responses to the RAl's in Reference 2. The purpose of this letter is to correct Reference 3 listed in the cover letter of Reference 4, and replace STPNOC's response in Reference 4, with the revised qualifications methodology in regards to Reference 2, RAI question 2d.
The Enclosure to this letter contains the specific revision to the Reference 2, RAI question 2d.
There are no commitments in this letter.
STI: 34438577
NOC-AE-17003441 Page 2 of 3 If there are any questions regarding this submittal, please contact Arden Aldridge, STP License Renewal Project Lead, at (361) 972-8243 or Rafael Gonzales, STP License Renewal Project regulatory point-of-contact, at (361) 972-4779.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on fe~
q 1. dfJJ 7-te rjg
Enclosure:
ames Connolly Site Vice President Revised STPNOC License Renewal Application Response to Request for Additional Information - Item 2d
cc:
(paper copy)
Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Lisa M. Regner Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 G9A) 11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN116 Wadsworth, TX 77483 Lois James License Renewal Project Manager (Safety)
One White Flint North (MS 011-F1)
U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Tam Tran License Renewal Project Manager (Environmental)
One White Flint North (MS 011 F01)
U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 (electronic copy)
NOC-AE-17003441 Page 3.of.3 Morgan. Lewis & Beckius LLP Steve Frantz Paul Bessette U.S. Nuclear Regulatory Commission Lisa M. Regner Lois James Tam Tran NRG South Texas LP Chris O'Hara -
Jim von Suski!
Skip Zahn CPS Energy Kevin Pollo Cris Eugster L. D. Blaylock City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free
NOC-AE-17003441 Enclosure Revised STPNOC License Renewal Application Response to Request for Additional Information - Item 2d
RAI 82.1.37-8 NRC Request:
_Page-1 of.1
- 2. State the following in relation to the UT technique capable of characterizing the extent of selective leaching in aluminum bronze welds:
- d. The qualifications of the individuals conducting the examinations and evaluating the examination results:
Revised STPNOC Response:
Personnel conducting TOFD examinations and evaluating results are qualified in accordance with STPNOC Procedure OPEP10-ZA-0001 (Non Destructive Examination Written Practice).
This procedure prescribes\\the requirements for experience, training, education, examination, qualification and certification of personnel performing nondestructive examinations in accordance wi~h ANSl/ASNT CP-189 (ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel) [1995]. The examination procedure requires an 80 hour9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br /> TOFD training class, and demonstration of proficiency in the detection and sizing of selective leaching.
- '