ML17046A436

From kanterella
Jump to navigation Jump to search
9 to Updated Final Safety Analysis Report, Tables 7.10-1 Through 7.10-3
ML17046A436
Person / Time
Site: Salem  
Issue date: 01/30/2017
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17046A230 List: ... further results
References
LR-N17-0034
Download: ML17046A436 (5)


Text

1.
2.
3.
4.
s.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.

18 *

19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.

38

source, Power, Intermediate Ranges, and Start-up rate Control Rod Positions Plant Vent Flow RCS Cold Leg Water Temperature RCS Hot Leg Water Temperature RCS Pressure Core Exit Temperature Coolant Level in Reactor Degrees of Subcooling Containment Sump Water Level Containment Pressure (Wide and Narrow Range)

Containment Isolation Valve Position (excluding check valves)

Containment Area Radiation Containment Hydrogen Concentration Containment Effluent Radioactivity (Noble Gases} from Identified Release Points RHR System Flow RHR Heat Exchanger Outlet Temperature Accumulator Tank Level and Pressure Accumulator Isolation Valve Position Boric Acid Charging Flow Charging Pumps Discharge Flow Safety Injection Pumps Discharge Flow Refueling Water Storage Tank Level Reactor coolant Pump Status (AMPS)

Primary System Safety/Relief Valve Position Pressurizer Level Pressurizer Heater Status {AMPS)

Pressurizer Relief Tank Level Pressurizer Relief Tank Temperature Pressurizer Relief Tank Pressure Steam Generator Level Steam Generator Pressure Main Steam Flow Main Feedwater Flow Auxiliary Feedwater Flow Auxiliary Feedwater Storage Tank Level Containment Spray Flow Additive Rate Heat Removal by the Containment Fan Coil Units (CFCU's) (CFCU Outlet Flow and CFCU Running) 1 of 2 SGS-UFSAR Revision 14 December 29, 1995

39.
40.
41.
42.

TABLE 7.10-1 (Cont)

SAFETY PARAMETER DISPLAY SYSTEM PARAMETERS Containment Atmosphere Temperature Letdown Flow Volume Control Tank Level Component Cooling Water Temperature

43.

Component Cooling Water Flow

44.

High Level Radioactive Liquid Tanks Levels

45.
46.
47.
48.
49.

so.

51.
52.
53.
54.
55.
56.

57 *

a.

Holdup Tanks

b.

Auxiliary Building Sump Tank

c.

Waste Monitor Holdup Tank

d.

Waste Holdup Tanks

e.

Reactor Coolant Drain Tank Radioactive Gas Hold Up Tank Pressure control Room Emergency Ventilation Damper Position Auxiliary Building Emergency Damper Position Fuel Handling Building Emergency Damper Position Status of Standby Power and Other Emergency Power Sources Important to Safety Control Air Pressure Main Steam Radiation Condenser Availability (Condenser Vacuum and Circulator Amperes)

Res Average Loop Temperature Main Steam Isolation Valve Position Reactor Trip Demand Signal from Train "A" Reactor Trip Demand Signal from Train "B" Auxiliary Building Roof Radiation Monitor 2 of 2 SGS-UFSAR Revision 14 December 29, 1995

TABLE 7.10-2 COMPARISON OF SAFETY FUNCTIONS WITH NUREG-0737 SUPPLEMENT 1 SAFETY FUNCTION NUREG-0737 SUPPLEMENT 1 Reactivity Control Reactor Core Cooling and Heat Removal from the Primary System Reactor Coolant SGS-UFSAR SAFETY FUNCTION STATUS TREE Shut Down Margin Core Cooling Heat Sink Thermal Shock Coolant Inventory 1 of 2 PARAMETERS

1. Neutron Flux 2
1. Core Exit Temperature
2. Degrees of Subcooling
3. Reactor Coolant Pump Status
4. Reactor Vessel Level
5. Hot Leg Temperature
6. Cold Leg Temperature
7. Steam Generator Level
8. Steam Generator Pressure
9.

RHR Flow lO.RCS Pressure ll.Containment Pressure 12.Containment Area Radiation

1. Steam Generator Level
2. Steam Generator Pressure
3. Auxiliary Feedwater Flow
4. Cold Leg Temperature
s. Main Feedwater Flow
6. RCS Pressure
7. RCS Cold Leg Water Temperature
8. Pressurizer Level
9. Reactor vessel Level lO.Reactor coolant Pump Status ll.Containment Sump Level 12.Pressurizer Temperature Revision 14 December 29, 1995

SAFETY FUNCTION NUREG-0737 SUPPLEMENT 1 Radioactivity Control Containment Conditions SGS-UFSAR TABLE 7.10-2 (cont.)

SAFETY FUNCTION STATUS TREE Radiation Monitoring Containment Environment 2 of 2 PARAMETERS

1. Containment Particulate Radiation
2. Plant Vent Particulate Radiation
3. Containment Radiation
4. Main Steam Radiation
5. Roof Monitor
1. Containment sump Water Level
2. Containment Pressure
3. Containment Area Radiation
4. Containment Hydrogen Revision 14 December 29, 1995

TABLE 7.10-3 CRITICAL SAFETY FUNCTIONS ASSOCIATED WITH BARRIERS BARRIER

2.

3

  • Fuel Matrix and Fuel Clad Reactor Coolant System Pressure Containment Vessel SGS-UFSAR CRITICAL SAFETY FUNCTIONS
a. Maintenance of SUBCRITICALITY (minimize energy production in the fuel)
b. Maintenance of a CORE COOLING (provide adequate reactor coolant for heat removal from the fuel)
c. Maintenance of a HEAT SINK (provide adequate secondary coolant for heat removal from the fuel)
d. control of Reactor Coolant INVENTORY (maintain enough reactor coolant for effective heat removal and pressure control)
a. Maintenance of a HEAT SINK (provide adequate heat removal from the RCS)
b. Maintenance of Reactor Coolant System INTEGRITY (prevent failure of RCS)
c. control of Reactor Coolant INVENTORY (prevent flooding and loss of pressure control)
d. Maintenance of CONTAINMENT Integrity (prevent failure of containment vessel) 1 of 1 Revision 14 December 29, 1995