Report No. R-P1793, Wall Thickness Profile Sheet. (Sketch)
ML16293A531
Person / Time
Site: Watts Bar 
Issue date: 10/05/2016
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16293A318 List: ... further results
References
CNL-16-135 R-P1793
Download: ML16293A531 (1)


Text

~ \\. C\\3 IHI IHI Southwest Technologies Examination Summary Record So\\lll'lwut l.c:h nologtti, In<..

Utlll : TVA Site: Watts Bar Nuclear Plant Unit 2 Outa e: PSI S stem: Reactor Pressure Vessel NOE Method AUT AUT AUT AUT AUT AET AET Proc/Rev/Ch ICN ISwT-POl-AUT11/1/0/0 ISwT-PDl-AUT11 /1 /0/0 ISwT-PDl-AUT11/1/0/0 ISwT-PDl-AUT11/1/0/0 ISwT-PDl-AUT11/1/0/0 ISwT-PDl-AET3/0/0/1 ISwT-PD l-AET3/0/0/1 Examination Summary:

Line Subassembl : Elbow to Safe End NOE Calibration Exam Sheet Examination Sheet No's.

No.

UT Probe 1 (60-88")

1100004-A 137 & 138 UT Probe 2 (60-88")

1100004-A 137 & 138 UT Probe 3 (O")

1100004-A 137 & 138 UT Probe 1 (60-88")

1100003-A 139 & 140 UT Probe 2 (60-88")

1100003-A 139 & 140 ET Probe 1 ET-03-001 137 & 138 ET Probe 2 ET-03-001 137 & 138 Summa Sheet No. 004300 Identification: RCF-C1-1 NRI Other Remarks x

UT Probe 3 (0°) for profilometry only.

x x x x x x This weld was examined from the inside surface using ANTS and T-111 examination equipment.

No recordable indications were detected during this examination.

The examination coverage was 50%. Scanned 100% of the examination area including the cast SS side (elbow side) using Appendix VIII qualified techniques. However, the procedure utilized is not qualified for SS c-cast material and no examination credit is taken for the c-cast side of the weld.

"""o_ate: i *z..., 1 3 /I (