Text

I ff I IHI Southwest Technologies Examination Summary Record Southwest Technologla. Inc.

Utlll : TVA Site: Watts Bar Nuclear Plant Unit 2 Outa e: PSI S

m: Reactor Pressure Vessel NOE Method AUT AUT AUT AUT AUT AET AET Proc/Rev/Ch ICN ISwT-PDl-AUT11/1/0/0 ISwT-POl-AUT11/1/0/0 ISwT-POl-AUT11/1/0/0 ISwT-PDl-AUT11/1/0/0 ISwT-PDl-AUT11 /1/0/0 ISwT-PDl-AET3/0/0/1 ISwT-PDl-AET3/0/0/1 Examination Summary:

Line Subassembl : Elbow to Safe End NOE calibration Exam Sheet Examination Sheet No's.

No.

lJT Probe 1 (60-88")

11 00004-A 129 & 130 UT Probe 2 (60-88")

1100004-A 129 & 130 UT Probe 3 (O")

1100004-A 129 & 130 UT Probe 1 (60-88")

1100003-A 131 & 132 lJT Probe 2 (60-88"1 11 00003-A 131 & 132 ET Probe 1 ET-03-001 131 & 132 ET Probe 2 ET 001 131 & 132 Summa Sheet No. 004200 Identification: RCF-C2-1 NRI Other Remarks X

UT Probe 3 (0°) for profilometry only.

x x

x x

x x

This weld was examined from the inside surface using ANTS and T-111 examination equipment.

No recordable indications were detected during this examination.

The examination coverage was 50%. Scanned 100% of the examination area including the cast SS side (elbow side) using Appendix VIII qualified techniques. However, the procedure utilized is not qualified for SS c-cast material and

~ no examination credit is taken for the c-cast side of the weld.

/