J HJ IHI Southwest Technologies Examination Summary Record 5outhwHt T..:h.,ologiu. In<.
Utlll : TVA Site: Watts Bar Nuclear Plant Unit 2 Outa e: PSI S stem: Reactor Pressure Vessel Line Subassembl : Elbow to Safe End NOE NOE Calibration Exam Sheet Method Proc/Rev/Ch ICN Examination Sheet No's.
No.
AUT ISwT-PDl-AUT11/1/0/0 UT Probe 1 (60-88")
1100004-A 105 & 106 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 2 (60-88"1 1100004-A 105 & 106 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 3 (O")
1100004-A 105 & 106 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 1 (60-88")
1100003-A 107 & 108 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 2 (60-88")
1100003-A 107 & 108 AET ISwT-PDl-AET3/0/0/1 ET Probe 1 ET-03-001 105 & 106 AET ISwT-PDl-AET3/0/0/1 ET Probe 2 ET-03-001 105 & 106 Examination Summary:
Summa Sheet No. 003900 Identification: RCF-C3-1 NRI Other Remarks X
UT Probe 3 (O") for profilometry only.
x x
x x x
x This weld was examined from the inside surface using ANTS and T-111 examination equipment.
No recordable indications were detected during this examination.
The examination coverage was 50%. Scanned 100% of the examination area including the cast SS side (elbow side) using Appendix VIII qualified techniques. However, the procedure utilized is not qualified for SS c-cast material and no examination credit is taken for the c-cast side of the weld.