ML16293A528
| ML16293A528 | |
| Person / Time | |
|---|---|
| Site: | Watts Bar |
| Issue date: | 10/05/2016 |
| From: | Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16293A318 | List:
|
| References | |
| CNL-16-135 R-P1788 | |
| Download: ML16293A528 (1) | |
Text
J HJ IHI Southwest Technologies Examination Summary Record Soutfiwnt Technolotl*., Inc.
Utili : TVA Site: Watts Bar Nuclear Plant Unit 2 Outa e: PSI S stem: Reactor Pressure Vessel Line Subassembl : Elbow to Safe End NOE NOE Calibration Exam Sheet Method Proc/Rev/Ch ICN Examination Sheet No's.
No.
AUT ISwT-PDl-AUT11/1/0/0 UT Probe 1 (60-88")
1100004-A 97 & 98 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 2 (60-88")
1100004-A 97 & 98 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 3 (O")
1100004-A 97 & 98 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 1 (60-88")
1100003-A 99 & 100 AUT ISwT-PDl-AUT11/1/0/0 UT Probe 2 (60-88")
1100003-A 99 & 100 AET ISWT-PDl-AET3/0/0/1 ET Probe 1 ET-03-001 97 & 98 AET I SWT-PDl-AET3/0/0/1 ET Probe 2 ET-03-001 97 & 98 Examination Summary:
Summa Sheet No. 003800 Identification: RCF-C4-1 NRI Other Remarks X
UT Probe 3 (O' ) for profilometry only.
x x x x x x
This weld was examined from the inside surface using ANTS and T-111 examination equipment.
No recordable indications were detected during this examination.
The examination coverage was 50%. Scanned 100% of the examination area including the cast SS side (elbow side) using Appendix VIII qualified techniques. However, the procedure utilized is not qualified for SS c-cast material and no examination credit is taken for the c-cast side of the weld.