J ff J IHI Southwest Technologies Examination Summary Record s-;~"'T.-.:~1rx._

Outage:

Utility: TVA I

Site: Watts Bar Nuclear Plant Unit 2 PSI Summary Sheet No. 000400 Svstem: Reactor Pressure Vessel Line Subassembly: Bottom Head to Lower Shell I

identification: W02-03 NOE NOE Calibration

  • Exam Sheet Method Proc/Rev/Chg/ICN Examination Sheet No's.

No.

NRI Other AUT ISwT-PDl-AUTS/1 /0/1 Probe 1 1100045 3-8 x

AUT ISwT-PDl-AUTS/1 /0/1 Probe 2 1100046 3-8 x

AUT ISwT-PDl-AUTS/1 /0/1 Probe 3 1100047 3-8 x

AUT ISwT-PDl-AUTS/1 /0/1 Probe 4 1100048 3-8 x

AUT ISw T-PDl-AUTS/1 /0/1 Probe 1 1100025 15 - 20b x

AUT ISw T-PDl-AUT5/1 /0/1 Probe 2 1100026 15 - 20b x

AUT ISw T-PDl-AUT5/1 /0/1 Probe 3 1100027 15-20b x

AUT ISw T-PDl-AUT5/1 /0/1 Probe4 1100028 15-20b x

AUT ISwT-PDl-AUT5/1/0/1 Probe 1 1100001 20c,d x

AUT ISwT-PDl-AUT5/1 /0/1 Probe 2 1100002 20c,d x

AUT ISw T-PDl-AUT5/1 /0/1 Probe 3 1100003 20c, d x

AUT ISwT-PDl-AUT5/1/0/1 Probe 4 1100004 20c, d x

Examination Summary:

This weld was examined from the inside surface using AIRIS-21 and Dynaray examination equipment.

No recordable indications were detected during this examination.

Examination Angles for each probe included: PA60°-80°L, PA40°-50°S, PA30°-6Q 0 L, & PA0°L.

Examination tfs 3 - 8 were divided into sections a - c.

Examination tfs 15 - 20 were divided into sections a - d.

Remarks This examination was limited due to the proximity of the core support lugs. The examination coverage was 88%.

Prepared By: Steven J. T1dd Signature: ~

/\\ ~

ISwT Project Manager

<.\\

R~vtfe~ By:\\,

~

S1gn.illire: ~

Tennessee Valley Authority