TVA WALL THICKNESS PROFILE SHEET REPORT NO:

PROJECT: ___

_.W:..z..wB:.:..N~------

UNIT: ______

R*c:ord Thickness Measurements As Indicated, lnc:ludlng Weld Width, Edge*To*Edge At 0° Position o*

90° 180° 210*

m * * *

  • rn 33'1.3'3.34+.349 rn

.}.4(,..247.2S8.J.sj

[!]

.z41.Z4l.:l48.z4S

[!]

,).44.z.~.Z.44,Z48 CROWN HEIGHT: ___

_.F<_~...:tl=:.S=-

  • ...:..H ______

CRQWN WIDTH: ____

.;..;*.3:::..:...1.=;,0 ______

Pe-~rr-()0

~~

qo~

"----7 I 31J 6

~7 270° ~r TV A 19668 {NP-5-89)

WELD NO: __

..;::;C....;;V..;:.C~F_-_;b~o....;;1~1_--=o:........;_1 ___

SYSTEM: ________

c_v~c~s==-----------

  • Weld Edge 5

A~~1de Flowi.:

DIAMETER: ______

4.:..;';..::(),__ ______

WELD LENGTH: ____

....:1:...4i...:.*..:3..;..7S;;;._ _____

P1PE 1-108 - 999-~

TVA.

PROJECT: __

W:...;..::5;.;..;N:..__ __ SYSTEM:. __

~C-.1::1/~C'"'.5~----

Office of Nuclear Power Unit: ____

---'&,::..._ ___ WELD NO.:

c VCF-J)oll-0 I BY'.

LEVEL:

DATE: tJG"-o4- /I PAGE le TVA 1%69 (ONP-6-88)

REPORT rro.:

~-~l<;q~

,.;;;;;.----1 OF2_ __ ____.

WELD NUMBER Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 Item 7 Item 8 Item 9 Item 10 Item 11 Watts Bar Unit 2 TVA Proceaure N-GP-31 Attachments 3 & 4 Worksheet Version 1.0 dated 07/01/09 CVCF-D011-01 Required examination Volume in sq. in.

(width x height)

Number of scan directions Total Scan volume in sq. in.

Total length of weld Total required exam volume in cubic inches Exam volume acheived (sq. in.) in direction 1 X length of weld achieved Exam volume acheived (sq. in.) in direction 2 X length of weld achieved Exam volume acheived (sq. in.) in direction 3 X length of weld achieved Exam volume acheived (sq. in.) in direction 4 X length of weld achieved Determined the acheived exam volume add 6, 7, 8 & 9 Exam volume percentage item 1 O/item 5 x 100 Examination was limited on scan # 3 due to penetration configuration Measured Fields sq. in.

____ 4~1directions sq. in.

14.J751 inches Initials JA cu. in.

cu. In.

cu. In.

cu. In.

cu. In.

cu. In.

Date 05/05/2011