ML16293A514
| ML16293A514 | |
| Person / Time | |
|---|---|
| Site: | Watts Bar |
| Issue date: | 10/05/2016 |
| From: | Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML16293A318 | List:
|
| References | |
| CNL-16-135 R-P1426 | |
| Download: ML16293A514 (3) | |
Text
REPORT NO:
- WALL THICKNESS PROFILE SHEET
~
- \\:>\\~'9~
PROJECT:
W BN WELD No: __
__;,,..F~WL.!.t=___.-1>~.;i.LA13""--...... a~3-----
UNIT: _______
-"-~------
R.cord Thlckne11 Measurements As lndlc1ted, lncludlng Weld Width, Edge*To*Edge At 0° Poalllon o*
90° 180° 270° DJ C!1
.G33 *"&> ~>.~
rn
.s;q "'4t3.S3o *'-33 5]
544.588.5S~
- ~"
VALVE
-Side CROWN HEIGHT: ___
l2.:....4'::L11:2.,,.Si=...-____
CRQWN WIDTH:-----'-'""'9~() _______
eL.ow =
__ VALVE svs1eM: ____
~~~F~11t~~=-~----~-
- Weld Edge 5
Flow*
DIAMETER: ______
4-:i...:..;* 0:.....-------
WELD LENGTH: ___
........:;.;J;....;;~.;..;.'..;;..;2'-"$""'--------
~i~------------
/ gl)o
~~r:__~---------
., 70°
~ ~_Lf ----------
LEYEL:. ___
___,~------
DATE:
PAGE OF
'IV A 19668 (NP-S-89) l*IOM99*44
TVA PROJECT:
WBN SYSTEM:
AF'WS Office of Nuclear Power UNIT: ___ ~~--- WELD NO: FWF*Jj;l/3- 03 Ft.ow VJl.LVE BY:~
~LEVEL:.:iC-DATE: 0/-10-1 1 PAGE lo OF_~_
WELD NUMBER Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 Item 7 Item 8 Item 9 Item 10 Item 11 Watts Bar Unit 2 TVA Procedure N-GP-31 Attachments 3 & 4 Worksheet Version 1.0 dated 07/01/09 FWF-0213-03 Required examination Volume in sq. in.
(width x height)
Number of scan directions Total Scan volume in sq. in.
Total length of weld Total required exam volume in cubic inches Exam volume acheived (sq. in.) in direction 1 X length of weld achieved Exam volume acheived (sq. in.) in direction 2 X length of weld achieved Exam volume acheived (sq. in.) in direction 3 X length of weld achieved Exam volume acheived (sq. in.) in direction 4 X length of weld achieved Determined the acheived exam volume add 6, 7, 8 & 9 Exam volume percentage item 1 O/item 5 x 100 Scan limitation due to configuration of valve.
1.4 0.06075 0.2.1 0.21 Measured Fields 22.25 sq. in.
~I directions sq. in.
22.251 inches Initials JA Date 01/21/2011 cu. in.
cu. In.
cu. In.
cu. In.
cu. In.
cu. In.
%