Forwards Safety Evaluation Accepting Util Response to IE Bulletin 79-27 Concerns Re Capability of Operators to Achieve Cold Shutdown Condition Following Loss of Power to Buses Supplying Power to Plant Instrumentation & Controls
ML16131A280
Person / Time
Site: Oconee  
Issue date: 12/07/1989
From: Wiens L
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
Shared Package
ML16131A281 List:
References
IEB-79-27, TAC-68202, TAC-68203, TAC-68204, NUDOCS 8912150084
Download: ML16131A280 (2)


Text

December 7, 10 Docket Nos. 50-269, 50-270, and 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

SUBJECT:

OCONEE UNITS 1, 2 AND 3 - AUDIT FOR VERIFICATION OF RESOLUTION OF IE BULLETIN 79-27 CONCERNS (TACS 68202/68203/68204)

During the week of May 8, 1989, the NRC conducted an audit to verify that concerns raised in IE Bulletin 79-27 had been adequately resolved for the Oconee Nuclear Station. This audit was conducted as part of the staff audit of the B&W "Safety and Performance Improvement Program (SPIP)."

The concerns in IE Bulletin 79-27 were associated with the capability of operaters to achieve a cold shutdown condition following a loss of power to buses supplying power to plant instrumentation and controls.

The audit consisted of scenarios in which three sample plant distribution system buses are failed, one at a time, and evaluating the consequence with regard to the operator's capability to achieve cold shutdown of the plant using the approved procedures. For each of the sample cases, there remained sufficient operable instruments and indications in the control room in con junction with adequate operator training and procedures to allow the operator to achieve cold shutdown. Therefore, the NRC staff finds the IE Bulletin 79-27 concerns to be adequately resolved for the Oconee Nuclear Station design and procedures. Enclosed is our Safety Evaluation for this issue.

This completes our action on this issue under TACs 68202/68203/68204.

Sincerely,

/s/

Leonard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/Il Office of Nuclear Reactor Regulation

Enclosure:

As stated D

C. A vwt K, cc w/enclosure:

iX C.

See next page

- 0 DISTRIBUTION Docket File L. Wiens 14-H-25 bI NRC PDR OGC (For inform. Only) 15-B-18 Local PDR E. Jordan MNBB-3302 PDII-3 Reading ACRS (10)

P-315 DFo/

oTI:L S. Varga 14-E-4 S. Newberry 7-E-12 G. Lainas 14-H-3 I.

Ahmed 7-E-12 D. Matthews 14-H-25 C. Harbuck 13-D-18 R. Ingram 14- -25

[Oconee Plant File]

OFC :LA:PDII-3

PM PDII-3 13 NAME :RIngraml
L iens-ch
D hews DATE : /

COPY89

\\ 1/

/89 FICIAL RE:CE COPY Document Name:

TUCKER LTR 11/16

Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:

Mr. A. V. Carr, Esq.

Mr. Paul Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.

Bishop, Cook, Purcell & Reynolds Mr. Alan R. Herdt, Chief 1400 L Street, N.'.

Project Branch #3 Washington, D.C. 20005 U.S. Nuclear Regulatory Corission 101 Marietta Street, NW, Suite 29^0 Mr. Robert B. Borsum Atlanta, Georgia 3C323 Babcock & Wilcox Nuclear Power Division Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike N. C. Department of Justice Rockville, Maryland 20852 P.O. Box 629 Raleigh, North Carolina 27602 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 34623-1693 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 26G0 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 County Supervisor of Oconee County Walhalla, South Carolina 29621